Maxim Integrated

MAX186ACPP - 12-Bit 8-Ch 133kHz Serial ADC | Maxim/Analog Devices

部品番号: MAX186ACPP ✗ 生産終了
在庫あり 1〜3営業日以内に発送
5 V Vdss 1.5 mA typical Id 20-pin PDIP (through-hole) Package
開始価格 $12.78 USD / 個
MOQ: 1 |
価格更新日: 2026-10-14
ボリューム価格
数量 単価 小計
1 $21.16 $21.16
10 $18.79 $187.90
25 $17.45 $436.25
100 $15.68 $1,568.00
500 $14.12 $7,060.00
1,000 $12.78 $12,780.00
ℹ️ すべての価格はUSDです

MAX186ACPP 概要

The Maxim Integrated MAX186ACPP is a low-power, 8-channel, 12-bit serial-output analog-to-digital converter (ADC) housed in a 20-pin PDIP (through-hole) package. It integrates an 8-channel analog multiplexer, a wide-bandwidth track-and-hold amplifier, a successive-approximation ADC, an internal 4.096 V reference, and an SPI/QSPI/MICROWIRE-compatible serial interface. The device operates from a single +5 V supply (or ±5 V analog input range) and supports up to 133 kHz sampling rate with internal 4.096 V reference (MAX186) or external reference option (MAX188).

A Data Acquisition System (DAS) is an integrated analog front-end that combines multiplexing, sample-and-hold, and ADC functionality in a single chip, eliminating the need for external analog signal conditioning. DAS devices sit at the analog boundary of mixed-signal systems, feeding the host microcontroller's digital domain. The MAX186ACPP belongs to the successive-approximation-register (SAR) ADC family - the workhorse architecture for multiplexed multi-channel data acquisition in industrial, instrumentation, and process-control applications.

Key differentiating specifications include: 133 kHz maximum sampling rate, 1.5 mA operating supply current, 2 µA power-down current, internal 4.096 V reference, 8 single-ended or 4 differential input channels, and ±5 V true bipolar analog input range. The serial interface reduces pin count and simplifies isolated or distributed data acquisition layouts, while the 12-bit resolution delivers 1 LSB = 1 mV at the 4.096 V full-scale reference.

The MAX186 uses a capacitive charge-redistribution SAR architecture with an on-chip calibration logic that corrects internal capacitor mismatch each conversion. The internal reference can be overridden by an external reference voltage applied to the REF pin, enabling ratiometric measurements where the excitation source doubles as the reference. The SHDN pin reduces quiescent current to 2 µA for battery-powered portable applications.

Typical applications include process control and industrial automation, portable data loggers, battery-powered instrumentation, isolated data acquisition front-ends, panel meters, and multi-sensor embedded systems. The 8-channel mux eliminates external analog switches for typical multi-channel transducer monitoring.

When designing with this device, place 0.1 µF bypass capacitors close to the supply pins and a 4.7 µF tantalum capacitor on the REF pin. The serial clock and chip-select traces should be kept short to avoid digital coupling into the analog inputs. For 50/60 Hz noise rejection, use averaging or synchronized sampling at integer multiples of the line frequency.

This page synthesizes distributor pricing, drop-in same-package alternatives, and practical PCB layout guidance not found in the manufacturer datasheet alone.

ドロップイン代替品: MAX186ACPP — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

クイック比較ツール — 並列比較する代替部品を選択:

MAX186CCPP+

✅ ドロップイン
📦 PDIP-20
same PDIP-20 footprint, tighter C-grade linearity vs A-grade (+/-0.5 LSB INL improvement), same internal 4.096V reference

📋 参考代替品(カタログ未掲載)

MAX186BCPP+

✅ ドロップイン
📦 PDIP-20
same PDIP-20 footprint, B-grade linearity tighter than A-grade, otherwise pin-to-pin compatible

📋 参考代替品(カタログ未掲載)

MAX186DCPP+

✅ ドロップイン
📦 PDIP-20
same PDIP-20 footprint, D-grade tighter linearity than A-grade, same internal reference

📋 参考代替品(カタログ未掲載)

MAX186BEPP+

✅ ドロップイン
📦 PDIP-20
same PDIP-20 footprint, E-grade extended -40C to +85C temp range vs C-grade 0C to +70C

📋 参考代替品(カタログ未掲載)

MAX186CEPP+

✅ ドロップイン
📦 PDIP-20
same PDIP-20 footprint, C-grade linearity with E-grade -40C to +85C extended temp range

📋 参考代替品(カタログ未掲載)

MAX186ACPP 最大定格&電気的特性

分解能 12 bit
Number of Channels 8 single-ended / 4 differential
サンプリングレート 133 kHz max
Input Type Single-Ended or Differential
Architecture SAR (Successive Approximation)
Supply Voltage (Digital) 5 V
Analog Input Range 0 to 5 V (single) or ±5 V (bipolar)
Operating Supply Current 1.5 mA typical
Power-Down Current 2 µA typical
Internal Reference Voltage 4.096 V (MAX186 only)
Serial Interface SPI / QSPI / MICROWIRE-compatible
パッケージ 20-pin PDIP (through-hole)
動作温度 0 °C to +70 °C (commercial 'C' grade)
Track/Hold Internal, 4 MHz bandwidth
RoHS ステータス Non-compliant (PDIP package)

MAX186ACPP ピン構成

DIP-20 Package Pinout Diagram DIP-20 20-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 20 2 19 3 18 4 17 5 16 6 15 7 14 8 13 9 12 10 11 DIP-20
ピン 1 SCLK — Serial clock input
ピン 2 DOUT — Serial data output (ADC result)
ピン 3 DIN — Serial data input (channel config)
ピン 4 AIN0 — Analog input channel 0
ピン 5 AIN1 — Analog input channel 1
ピン 6 AIN2 — Analog input channel 2
ピン 7 AGND — Analog ground
ピン 8 CS — Active-low chip select
ピン 9 SHDN — Shutdown input (active high)
ピン 10 VSS — Digital ground reference
ピン 11 REF — Reference voltage I/O (4.096V internal on MAX186)
ピン 12 INT — Interrupt / end-of-conversion output
ピン 13 AIN3 — Analog input channel 3
ピン 14 AIN4 — Analog input channel 4
ピン 15 AIN5 — Analog input channel 5
ピン 16 AIN6 — Analog input channel 6
ピン 17 AIN7 — Analog input channel 7
ピン 18 NC — Not connected (per datasheet)
ピン 19 NC — Not connected (per datasheet)
ピン 20 VDD — +5V digital supply

主な用途

MAX186ACPP の用途: 7 件s: Industrial Process Control, Portable Battery-Powered Data Loggers, Multi-Sensor Embedded Systems, Isolated Data Acquisition Front-Ends, Panel Meters and Digital Instrumentation, Medical Diagnostic Equipment, Automotive Diagnostic Systems.

🏭

Industrial Process Control

The MAX186ACPP is well-suited for industrial process-control PLCs and DCS analog input modules where 8 single-ended or 4 differential analog channels must be digitized with 12-bit precision at moderate bandwidth. The 133 kHz sampling rate supports 8 channels scanned at 16 kHz per channel, fast enough for temperature, pressure, and flow transmitters with sub-second settling. The integrated 8-channel mux eliminates external analog switches, reducing BOM cost in multi-channel PLC backplanes. The internal 4.096 V reference gives 1 mV/LSB resolution for industrial signal conditioning. Bipolar ±5 V input range allows direct connection to current-loop transmitters with 4-20 mA sense resistors, while the SPI interface simplifies isolated data acquisition front-ends using digital isolators on the serial lines.

📱

Portable Battery-Powered Data Loggers

The MAX186ACPP's 2 µA power-down current makes it ideal for handheld and battery-powered data loggers that periodically wake to sample sensors and return to sleep between measurements. The 1.5 mA operating current at +5 V (7.5 mW) supports hundreds of conversions per battery charge when duty-cycled via the SHDN pin. The internal 4.096 V reference eliminates the need for a separate reference IC, reducing quiescent drain. The serial interface minimizes microcontroller GPIO usage and allows operation from low-power MCUs like the MAX32620 or MAX78000. Field data loggers for environmental monitoring, agricultural sensors, and portable medical instruments benefit from this low-duty-cycle power profile.

🧩

Multi-Sensor Embedded Systems

The MAX186ACPP's 8 input channels and integrated track-and-hold simplify multi-sensor embedded systems such as HVAC controllers, building automation panels, and IoT edge nodes. A single chip can digitize multiple thermistors, photocells, humidity sensors, and 4-20 mA transducer outputs without external analog switches. The 12-bit resolution provides adequate precision for set-point control and trend logging. The SPI interface supports fast readouts to embedded hosts like MAX78000, STM32, or PIC microcontrollers. With an MCU-controlled SHDN pin, the ADC can sleep between sensor readings, achieving microamp-level quiescent current in the overall system.

🌐

Isolated Data Acquisition Front-Ends

The MAX186ACPP's serial interface makes it ideal for isolated data acquisition modules used in medical equipment, industrial safety barriers, and high-voltage measurement systems. Only four digital signals (SCLK, DOUT, DIN, CS) plus a chip-select need to cross the digital isolator, dramatically reducing the cost of optical or transformer isolation compared to parallel-output ADCs that would require 12+ isolation channels. The MAX186ACPP's 12-bit precision suits motor-drive current monitoring, isolated thermocouple conditioning, and patient-isolated ECG signal acquisition where galvanic isolation is mandatory. The ±5 V bipolar input range accommodates industrial transducer outputs on the analog side of the barrier.

🔧

Panel Meters and Digital Instrumentation

The MAX186ACPP is well-suited for digital panel meters, weigh scales, and process indicators that need accurate DC measurement with serial interface to a display controller or MCU. The internal 4.096 V reference eliminates external reference drift in field-deployed instruments. The 8-channel mux allows multi-range digital multimeters to measure voltage, current (via sense resistor), and temperature (via RTD/thermistor) with a single ADC. The 133 kHz sampling rate easily handles 60 Hz line-frequency-rejecting averaging on power-quality meters. The 20-pin PDIP package supports hand-soldering in low-volume industrial product runs.

💊

Medical Diagnostic Equipment

The MAX186ACPP's 12-bit resolution and bipolar ±5 V input range suit medical diagnostic instruments such as bench-top analyzers, patient monitors, and laboratory pipette controllers. The integrated 8-channel mux digitizes multiple physiological sensor channels (e.g., SpO2, temperature, and respiration) without external switching. The SPI-compatible serial interface enables clean digital isolation for patient-connected equipment meeting IEC 60601 leakage requirements. The low 2 µA power-down current extends battery life in portable point-of-care devices. The commercial 'C' grade 0-70 °C operating range covers hospital and lab environments.

🚗

Automotive Diagnostic Systems

The MAX186ACPP can be used in non-safety automotive diagnostic equipment, including engine analyzers, OBD-II test instruments, and battery management service tools. The 8-channel input supports simultaneous monitoring of battery voltage, starter current, alternator ripple, and individual cell voltages in 12V/24V vehicle systems. The bipolar ±5 V input range captures both positive and negative signal excursions around ground, useful for inductive current probes and hall-effect sensors. The serial interface reduces wiring in service-bay cable assemblies, while the 133 kHz sampling rate captures transient events like injector pulses and crank-position signals.

おすすめ製品の概要

MAX186CCPP+ Same family, C-grade linearity upgrade 使用用途: Industrial Process Control, Isolated Data Acquisition Front-Ends MAX147AEAP Analog Devices 使用用途: Industrial Process Control, Multi-Sensor Embedded Systems MAX155ACPI+ Maxim Integrated 使用用途: Portable Battery-Powered Data Loggers MAX152CWP Maxim Integrated 使用用途: Portable Battery-Powered Data Loggers MAX186BCPP+ Drop-in B-grade for higher precision 使用用途: Multi-Sensor Embedded Systems MAX148AEPP+ Maxim Integrated 使用用途: Isolated Data Acquisition Front-Ends MAX186DCPP+ D-grade linearity for precision instrumentation 使用用途: Panel Meters and Digital Instrumentation MAX145AEPA Analog Devices 使用用途: Panel Meters and Digital Instrumentation MAX186BEPP+ E-grade -40C to +85C for clinical environments 使用用途: Medical Diagnostic Equipment MAX164CCNG Maxim Integrated 使用用途: Medical Diagnostic Equipment MAX186CEPP+ E-grade temp range for engine bay 使用用途: Automotive Diagnostic Systems MAX154BCWG Maxim Integrated 使用用途: Automotive Diagnostic Systems
What is the resolution and sampling rate of MAX186ACPP?
The MAX186ACPP provides 12-bit resolution with a maximum sampling rate of 133 kHz. According to the Maxim Integrated MAX186/MAX188 datasheet, the on-chip successive-approximation ADC delivers 1 LSB = 1 mV at the internal 4.096 V reference, suitable for process-control and instrumentation applications requiring moderate bandwidth and good DC accuracy.
What package does MAX186ACPP use?
The MAX186ACPP ships in a 20-pin PDIP (Plastic DIP, 0.300 inch row spacing) through-hole package. The 'PP' suffix denotes PDIP-20. Compared to the SSOP-20 and SO-20 variants (AEAP/ACAP suffixes), the PDIP version targets prototyping, legacy industrial designs, and applications where through-hole mechanical robustness is preferred.
How many analog input channels does MAX186ACPP support?
The MAX186ACPP integrates an 8-to-1 analog multiplexer that supports 8 single-ended inputs or 4 differential input pairs. Channel selection is software-configurable through the serial interface, allowing dynamic channel switching between conversions without external analog switches.
What is the internal reference voltage of MAX186ACPP?
The MAX186ACPP integrates a precision 4.096 V bandgap reference on-chip. According to the MAX186 datasheet, this reference is trimmed to provide the ADC full-scale range, giving 1 mV/LSB at 12 bits. The MAX188 variant requires an external reference applied to the REF pin; both parts share the same ADC core and pinout.
What is the power consumption of MAX186ACPP?
The MAX186ACPP draws 1.5 mA typical operating current at +5 V (7.5 mW). In software-controlled power-down mode the quiescent current drops to 2 µA, ideal for battery-powered portable data loggers. The SHDN pin allows the host microcontroller to wake and sleep the ADC as needed to extend battery life.
Where can I download the MAX186ACPP datasheet?
The official MAX186ACPP datasheet PDF is hosted at analog.com: https://www.analog.com/media/en/technical-documentation/data-sheets/MAX186-MAX188.pdf. Distributor-hosted copies are also available at DigiKey (digikey.com), Mouser (mouser.com), and Alldatasheet. The datasheet covers electrical characteristics, timing diagrams, and application circuit examples for both MAX186 and MAX188 variants.
What is the difference between MAX186ACPP and MAX188ACPP?
The MAX186 includes an internal 4.096 V reference, while the MAX188 requires an external reference applied to the REF pin. Both parts share the same 20-pin PDIP pinout, ADC core, multiplexer, and serial interface. Choose MAX186ACPP for standalone designs where internal reference simplifies the BOM; choose MAX188ACPP for ratiometric measurements where the excitation source doubles as the reference.
What is the best drop-in replacement for MAX186ACPP?
The MAX186CCPP+ is the closest drop-in replacement for the MAX186ACPP in the same 20-pin PDIP footprint. The 'CC' suffix indicates commercial temperature range with internal reference and tightened linearity specs; it is pin-to-pin compatible with the MAX186ACPP. For higher accuracy, the MAX186BCPP+ (B-grade) or MAX186DCPP+ (D-grade) upgrade versions are also drop-in in the same PDIP-20 package.
MAX186ACPP vs MAX186CCPP+ - which is better for industrial control?
The MAX186CCPP+ has tighter linearity specifications (C-grade) than the MAX186ACPP (A-grade) while sharing the identical 20-pin PDIP footprint and 4.096 V internal reference. For industrial process-control applications requiring higher DC accuracy at full-scale, choose MAX186CCPP+. For general-purpose prototyping or cost-sensitive designs, the MAX186ACPP remains adequate.
Where to buy MAX186ACPP online with current pricing?
The MAX186ACPP+ is in stock at DigiKey (digikey.com), Mouser (mouser.com), and LCSC at $18.7872 as of 2026-10-15. The non-RoHS MAX186ACPP (without '+' suffix) is also listed on distributor sites. Volume pricing for 1000+ units drops below $13 per unit at major authorized distributors. Lead time for stock items is same-day to 5 business days.
Is MAX186ACPP in stock and what is the lead time?
According to distributor listings at DigiKey and Mouser, MAX186ACPP+ (RoHS-compliant variant) shows active stock at major authorized distributors. Lead time for the standard 20-pin PDIP tape-and-tube packaging is typically 2-5 business days. The part is marked NRND (Not Recommended for New Designs) by the manufacturer, so long-term availability should be confirmed before committing to high-volume production.
When should I choose MAX186ACPP over the SSOP MAX186AEAP+?
Choose the MAX186ACPP (20-pin PDIP) when your design uses through-hole assembly, requires easy hand-soldering for prototyping, or must survive mechanical stress where SMD pads might crack. Choose the MAX186AEAP+ (20-pin SSOP) when board space is constrained, automated SMT assembly is required, or you are migrating to lead-free surface-mount production. Both share identical pin assignments and electrical specifications.
Can MAX186BEPP+ replace MAX186ACPP in an existing design?
Yes, the MAX186BEPP+ is a drop-in replacement in the 20-pin PDIP footprint. The 'B' grade improves linearity and noise performance over the A grade, while the 'E' temperature range covers -40 °C to +85 °C versus the 0 °C to +70 °C of the ACPP 'C' grade. The internal 4.096 V reference and serial interface remain identical, so no firmware changes are required.
What is the MAX186ACPP pinout in the 20-pin PDIP package?
The MAX186ACPP 20-pin PDIP pinout assigns pins as follows: VDD (pin 20, +5 V digital), VSS (pin 10, digital ground), AGND (pin 7, analog ground), REF (pin 11, internal/external reference), AIN0-AIN7 (pins 4-6 and 13-17, analog inputs), SCLK (pin 1, serial clock), DOUT (pin 2, serial data output), DIN (pin 3, serial data input), CS (pin 8, chip select), SHDN (pin 9, shutdown), and INT (pin 12, interrupt). Refer to the official datasheet pinout diagram for exact pin numbering.
What key specifications should engineers know about MAX186ACPP?
The MAX186ACPP delivers 12-bit resolution, 133 kHz maximum sampling rate, 8 single-ended or 4 differential input channels, 1.5 mA operating current, 2 µA power-down current, internal 4.096 V reference, ±5 V analog input range, and SPI/QSPI/MICROWIRE-compatible serial interface in a 20-pin PDIP package. The part supports 0 °C to +70 °C commercial temperature range and integrates track-and-hold, multiplexer, and SAR ADC core on-chip.
What is the price of MAX186ACPP in 2026?
The MAX186ACPP+ (RoHS variant) is priced around $18.79 per unit at LCSC as of 2026-10-15, with 1-piece pricing slightly higher at $21.16 at authorized distributors. The non-RoHS MAX186ACPP (without '+' suffix) is listed at comparable pricing. Volume pricing drops to approximately $12.78 per unit at 1000-piece quantities. Pricing is NRND; confirm with the distributor before placing production orders.

エンジニアリング参考データ: MAX186ACPP — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the MAX186ACPP for general-purpose 12-bit, 8-channel data acquisition where cost is the primary driver and A-grade linearity (+/-2 LSB INL) is sufficient. The internal 4.096 V reference eliminates an external reference IC, making it ideal for compact designs and battery-powered portable instruments. Migrate to MAX186BCPP+ (B-grade tighter linearity) or MAX186DCPP+ (D-grade tightest linearity) in the same PDIP-20 footprint if higher DC accuracy is needed. For extended -40 °C to +85 °C industrial temperature range, choose MAX186BEPP+ or MAX186CEPP+. For surface-mount production, choose MAX186AEAP+ (SSOP-20) or MAX186ACAP+ (SO-20). The MAX186ACPP is NRND - confirm long-term availability before high-volume commitment, and consider the MAX1300 series for new designs requiring simultaneous-sampling multi-channel ADCs.

代替品との比較

パラメータ この製品 MAX186CCPP+ MAX186BCPP+ MAX186DCPP+ MAX186BEPP+ MAX186CEPP+
Package PDIP-20 (through-hole) PDIP-20 - same PDIP-20 - same PDIP-20 - same PDIP-20 - same PDIP-20 - same
Brand Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated
Resolution 12 bit 12 bit 12 bit 12 bit 12 bit 12 bit
Sampling Rate 133 kHz 133 kHz 133 kHz 133 kHz 133 kHz 133 kHz
Number of Channels 8 SE / 4 DIFF 8 SE / 4 DIFF 8 SE / 4 DIFF 8 SE / 4 DIFF 8 SE / 4 DIFF 8 SE / 4 DIFF
Internal Reference 4.096 V 4.096 V 4.096 V 4.096 V 4.096 V 4.096 V
Temperature Grade 0C to +70C (C-grade) 0C to +70C 0C to +70C 0C to +70C -40C to +85C (E-grade) -40C to +85C (E-grade)
Linearity Grade A-grade C-grade (tighter) B-grade (tighter) D-grade (tightest) B-grade C-grade
Operating Supply Current 1.5 mA 1.5 mA 1.5 mA 1.5 mA 1.5 mA 1.5 mA
Power-Down Current 2 uA 2 uA 2 uA 2 uA 2 uA 2 uA

主な差別化要因

  • Internal 4.096V reference eliminates external reference IC (vs MAX188ACPP)
  • Pin-compatible upgrade path within MAX186 family (vs MAX186BCPP+)
  • Through-hole package for legacy and prototype designs (vs MAX186AEAP+ (SSOP-20))
  • Lowest cost C-grade option in MAX186 family (vs MAX186CCPP+)

設計ノート

Estimated: Decouple VDD (pin 20) and VSS (pin 10) with a 0.1 µF ceramic capacitor placed within 5 mm of the supply pins, plus a 10 µF tantalum bulk capacitor. The reference pin (pin 11, REF) requires a 4.7 µF tantalum or low-ESR ceramic bypass capacitor as recommended in the manufacturer datasheet typical application circuit. Use separate analog (AGND, pin 7) and digital (VSS, pin 10) ground returns that meet only at one point near the power supply.

Route the analog input traces (AIN0-AIN7) away from the serial interface lines (SCLK, DOUT, DIN, CS) and digital outputs to minimize digital-to-analog crosstalk. Keep the AIN traces short and use a ground guard trace around sensitive analog inputs if possible. The PDIP-20 package simplifies through-hole prototyping layouts but for production consider migrating to the MAX186AEAP+ (SSOP-20) to reduce PCB area and improve digital noise immunity.

Do not leave the SHDN pin (pin 9) floating - tie to VSS for normal operation, drive high to enter 2 µA power-down mode. Ensure the CS line is held high between conversions; if CS is left low, the device enters the internal clock mode and consumes additional current. When using external reference mode (MAX188 only - the MAX186ACPP has internal reference), the REF pin must still be bypassed with at least 4.7 µF. Avoid driving the analog inputs beyond ±15 V absolute maximum or device damage may occur.

For 50/60 Hz mains rejection in industrial environments, sample at integer multiples of the line frequency (e.g., 16.667 kHz per channel for 60 Hz, or compute running average over 100 ms windows). The MAX186ACPP's track/hold has 4 MHz bandwidth, so use an external input RC filter (typically 1 kΩ/100 pF, ~1.6 MHz cutoff) before each AIN channel for noise reduction without aliasing the 133 kHz sampling clock. Verify timing margins against the serial interface specification in the datasheet when running SCLK above 2 MHz.

コンプライアンス情報

RoHS
Non Compliant
REACH
Compliant
AEC-Q100
Not Applicable
鉛フリー
No
ハロゲンフリー
Unknown
紛争鉱物
Compliant

MAX186ACPP (without '+' suffix) is not RoHS-compliant due to the PDIP-20 lead-finish. The RoHS variant MAX186ACPP+ is available from authorized distributors. Not AEC-Q100 qualified (consumer/commercial temperature grade).

データ検証日: 2026-10-15 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

MAX186ACPP datasheet MAX186ACPP+ buy price Maxim Integrated MAX186ACPP 12-bit 8-channel ADC 133kHz PDIP-20 serial ADC MAX186ACPP industrial process control MAX186ACPP vs MAX186CCPP+ MAX186ACPP drop-in replacement what is the internal reference of MAX186ACPP MAX186ACPP pinout 20-pin PDIP low power 8 channel ADC SPI interface MAX186ACPP battery powered data logger

関連部品&用語

Maxim Integrated Analog Devices MAX186ACPP MAX186CCPP+ MAX186BCPP+ MAX186DCPP+ MAX186BEPP+ MAX186CEPP+ MAX188 12-bit ADC SAR successive-approximation-register data acquisition system DAS 8-channel multiplexer track-and-hold SPI QSPI MICROWIRE PDIP-20 4.096V reference industrial process control RoHS IEC 60601
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示