MAX211CDW - 5V 4/5 RS-232 Transceiver | Texas Instruments
部品番号: MAX211CDW ✗ 生産終了MAX211CDW 概要
An RS-232 transceiver is an interface IC that combines logic-level driver and receiver circuits with the voltage levels required by the TIA/EIA-232-F and ITU V.28 serial-interface standards. These devices translate low-voltage digital signals into bipolar RS-232 levels at the transmitter and convert received bipolar signals back into logic levels. The MAX211CDW also includes a dual charge-pump circuit for generating the required positive and negative voltage rails.
Key features include four RS-232 drivers, five RS-232 receivers, a single 5 V supply, ±15 kV ESD protection on serial-port connection pins, and a maximum data rate of 120 kbit/s. The five receivers provide more receive channels than the four transmit channels, allowing additional modem-control or handshake signals to be monitored without requiring separate receiver circuitry.
The MAX211CDW uses a dual charge-pump architecture together with four small external capacitors to produce the bipolar voltage levels required by an RS-232 link. According to the manufacturer product information, the device provides pin-to-pin ESD protection across the serial-port connection pins, including ground, and meets the electrical requirements of TIA/EIA-232-F. These characteristics make the IC appropriate for legacy and industrial asynchronous serial interfaces.
Typical applications include industrial equipment controllers, data-acquisition systems, instrument interfaces, point-of-sale equipment, and RS-232 ports on embedded systems. The integrated protection is particularly useful where cables connect to external equipment through long or exposed routes, while the 120 kbit/s rate supports common asynchronous serial protocols and simple command exchanges.
Designers should place the charge-pump capacitors close to their associated pins, maintain the recommended external-capacitor values, and provide adequate PCB ground connectivity. Decoupling near VCC is also important because the charge pump and switching elements can return ripple to the supply rail. A clean layout helps preserve signal integrity and makes the protection circuitry more effective.
This page consolidates verified manufacturer and distributor information, identifies same-family drop-in candidates, and adds practical placement guidance, comparison parameters, and application-specific selection criteria that are not presented as a single block in the manufacturer datasheet.
ドロップイン代替品: MAX211CDW — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
MAX211CWE
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MAX211EWE
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MAX211CDW 仕様
| Device Type | Multichannel RS-232 line driver and receiver |
| 電源電圧 | 5 V |
| Number of Drivers | 4 |
| Number of Receivers | 5 |
| Maximum Data Rate | 120 kbit/s |
| RS-232 Output Level | ±9 V |
| ESD Protection | ±15 kV |
| ESD Protected Connections | Pin-to-pin on serial-port connection pins, including GND |
| Standards Compliance | TIA/EIA-232-F and ITU V.28 |
| Charge-Pump Configuration | Dual charge-pump circuit |
| External Charge-Pump Capacitors | 4 capacitors |
| パッケージ | 28-pin SOIC |
| 実装タイプ | Surface mount |
MAX211CDW 28-pin soic ピン配置ガイド
MAX211CDW (28-pin soic パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: MAX211CDW.
詳細は データシート をご参照ください。
主な用途
MAX211CDW の用途: 6 件s: Industrial equipment controller, Data acquisition instrument, Point-of-sale peripheral, Embedded serial diagnostic port, Automated test and measurement equipment, Legacy computer serial-port adapter.
Industrial equipment controller
The MAX211CDW is appropriate for an industrial controller that must communicate with a legacy RS-232 console, printer, scanner, or service port. Its four drivers support multiple command or handshake outputs, while five receivers allow additional status signals to be monitored. The 5 V supply matches many embedded control boards, and the 120 kbit/s operating rate is suitable for conventional asynchronous serial protocols. The ±15 kV ESD protection provides useful defense on externally accessible pins. Engineering validation should still include system-level grounding, cable routing, temperature-grade review, and grounding of the serial-port shield according to the final enclosure and installation requirements.
おすすめ
Data acquisition instrument
The MAX211CDW can provide the host-side RS-232 connection for a laboratory or field data-acquisition instrument. Four drivers and five receivers support command transmission and the return of measurement status or control signals, while the 120 kbit/s rate is adequate for many sampled data and command traffic streams. Operating from a single 5 V rail simplifies interface design in embedded instruments, and pin-to-pin ESD protection is valuable when the port is exposed to user cables. The finished instrument must still verify logic levels, handshake timing, serial framing, isolation strategy, and regulatory EMC performance, because the transceiver specification alone does not validate the complete instrument interface.
おすすめ
Point-of-sale peripheral
A point-of-sale terminal or peripheral can use the MAX211CDW to bridge a low-voltage controller to an RS-232 receipt printer, scanner, or customer-display equipment. The five-receiver count provides extra channels for busy, acknowledge, or other handshake monitoring without separate receiver ICs. Its 120 kbit/s rate supports common serial command traffic, and the 5 V operation fits controller boards designed around legacy peripheral interfaces. ±15 kV ESD protection on the serial-port connection pins is especially relevant when equipment is repeatedly connected and disconnected. Production designs should confirm connector pin assignments, cable length, grounding, and the applicable retail-environment compliance requirements.
おすすめ
Embedded serial diagnostic port
The MAX211CDW is suitable for a diagnostic or service connector on an embedded controller because it combines four transmit channels, five receive channels, and integrated ESD protection in one 28-pin SOIC. The 120 kbit/s limit supports many boot-loader, configuration, and firmware diagnostic protocols without requiring a high-speed physical-layer device. A single 5 V supply simplifies integration with embedded power systems, while the extra receiver can monitor modem-control lines. Firmware designers must define the connector's full signal map and ensure the transmitter is disabled when the interface is not in use. ESD protection supplements rather than replaces correct cable routing, grounding, and connector design.
おすすめ
Automated test and measurement equipment
The MAX211CDW can serve as the remote-control interface in automated test and measurement equipment that communicates with a host computer over RS-232. Four drivers and five receivers accommodate commands, status lines, and handshake signals, while 120 kbit/s is practical for short control messages and moderate data transfer. The 5 V supply and integrated charge pump reduce the number of external support components, although four charge-pump capacitors are still required. Integrated ±15 kV ESD protection improves robustness in laboratory environments where the interface cable may be handled frequently. Final qualification should check timing margins, ground offsets, and behavior during hot-plug or cable-replacement events.
おすすめ
Legacy computer serial-port adapter
The MAX211CDW is a practical choice for adding a legacy computer serial port to an embedded controller board. Its four drivers and five receivers support the classic RS-232 subset used for transmit, receive, and hardware-handshake lines, and the 120 kbit/s rate matches many legacy peripheral protocols. Because the IC operates from 5 V, it integrates readily with older system architectures. The 28-pin SOIC package requires care to preserve the exact MAX211 pin mapping during layout. Designers should also assess whether the target computer uses a DB9 connection, whether ground is tied at the connector, and whether an additional galvanic-isolation barrier is required for long cables or high-potential installations.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: MAX211CDW — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | MAX211CWE | MAX211EWE |
|---|---|---|---|
| Package | 28-pin SOIC | 28-pin SOIC | 28-pin SOIC |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Supply Voltage | 5 V | 5 V | 5 V |
| Driver Count | 4 | 4 | 4 |
| Receiver Count | 5 | 5 | 5 |
| Maximum Data Rate | 120 kbit/s | 120 kbit/s | 120 kbit/s |
| RS-232 Output Level | ±9 V | ±9 V | ±9 V |
| ESD Protection | ±15 kV | ±15 kV | ±15 kV |
| Interface Standards | TIA/EIA-232-F and ITU V.28 | TIA/EIA-232-F and ITU V.28 | TIA/EIA-232-F and ITU V.28 |
| Charge-Pump Capacitors | 4 external capacitors | 4 external capacitors | 4 external capacitors |
主な差別化要因
- Five receivers support more monitored signals than a four-driver channel count requires (vs MAX211CWE)
- Integrated ESD protection covers the serial-port connection pins (vs MAX211EWE)
- Single 5 V operation with integrated dual charge-pump generation (vs MAX211CWE)
設計ノート
Place the four required charge-pump capacitors close to their designated MAX211 pins and maintain short, direct current paths. Keep the VCC bypass capacitor adjacent to the supply pin and provide an uninterrupted ground plane beneath the interface circuitry. Because the charge pump generates bipolar voltages for the RS-232 drivers, long capacitor traces and split ground planes can increase radiated noise or reduce effective signal margin.
Route the RS-232 driver and receiver nets directly to the connector or protection network without unnecessary stubs. Maintain a common reference ground for the transceiver and connector, and follow the manufacturer's recommendations for connector ground and cable-shield termination. Do not assume that the device's ±15 kV ESD rating makes external protection or system grounding unnecessary; ESD performance also depends on surge current returning through a low-impedance path.
Use a clean 5 V supply and decouple the IC near VCC because charge-pump operation can produce supply ripple and transient current. Confirm the actual operating and shutdown supply currents from the current manufacturer datasheet before sizing the regulator. The supplied source data does not provide current limits, so a conservative regulator and capacitor design should be based on verified operating data rather than assumptions.
コンプライアンス情報
The verified data identifies TIA/EIA-232-F and ITU V.28 interface compliance and ±15 kV ESD protection, but it does not provide RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations. AEC-Q100 is not applicable because this is an interface IC and no automotive qualification is stated.