MAX3232EESE+ - 3V-5.5V 1Mbps RS-232 Transceiver | Maxim
部品番号: MAX3232EESE+ ✓ 生産中MAX3232EESE+ 概要
An RS-232 transceiver is the electrical interface between a modern digital controller and an RS-232 port. Its integrated line drivers convert logic-level signals into RS-232 voltage levels, while its receivers perform the opposite conversion. The MAX3232E family belongs to the broader interface-IC hierarchy: transceiver → RS-232 interface IC → serial communications interface → semiconductor. An internal dual charge pump supplies the positive and negative voltages required by RS-232 without a separate negative power supply.
Key features include two transmit and two receive channels, operation from 3.0 V to 5.5 V, throughput up to 1 Mbps, and ±15 kV ESD protection on the serial-port pins. Four external 0.1 µF charge-pump capacitors support the on-chip voltage converter. The low-power receiver design can operate with supply current down to 10 nA, which benefits systems that keep a serial interface enabled for long periods or monitor a remote connection.
The MAX3232E architecture simplifies board design by integrating the charge-pump circuitry, drivers, receivers, and protection functions into one device. Its 16-SOIC package exposes two driver inputs, two driver outputs, two receiver inputs, two receiver outputs, supply connections, ground, and charge-pump capacitor terminals. Logic levels remain compatible with conventional microcontroller and UART systems operating at the device supply voltage, while the external line interface uses the bipolar voltage swings required by RS-232.
Typical applications include industrial control terminals, programmable-logic-controller serial ports, instrumentation, point-of-sale equipment, and embedded systems that connect a UART controller to an RS-232 connector. The 1 Mbps capability supports high-speed serial links, while ±15 kV ESD protection improves robustness when the cable is connected or disconnected in industrial environments.
For reliable operation, place the four 0.1 µF charge-pump capacitors close to their designated pins, route serial outputs away from sensitive analog nodes, and connect the device ground directly to the interface ground. Confirm signal polarity and enable state before attaching the port because RS-232 uses inverted logic relative to many UART controllers.
This page consolidates the device specifications, package and pin information, drop-in alternatives, and practical interface-circuit guidance into a design-focused reference. It also highlights the differences between the standard MAX3232 and the ESD-protected MAX3232E family for replacement and sourcing decisions.
ドロップイン代替品: MAX3232EESE+ — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: MAX3232EESE+ (同一形状・フットプリント) — 相違点: Maximum Data Rate, Supply Voltage Range, Interface Standard, Package, Product Type.
MAX3232ESE+
✅ ドロップイン価格はお問い合わせください
データシートを見る →MAX3232EESE+T
✅ ドロップイン価格はお問い合わせください
データシートを見る →MAX232ESE+
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →MAX242ESE
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MAX3232EESE+ 仕様
| Product Type | RS-232 transceiver interface IC |
| Number of Drivers | 2 channels |
| Number of Receivers | 2 channels |
| Supply Voltage Range | 3.0 V to 5.5 V |
| Maximum Data Rate | 1 Mbps |
| ESD Protection | ±15 kV |
| Receiver Supply Current | Down to 10 nA |
| Charge-Pump Capacitors | 4 external 0.1 µF capacitors |
| Standards Compatibility | TIA/EIA-232-F and V.28/V.24 |
| パッケージ | 16-pin SOIC |
| 実装タイプ | Surface mount |
MAX3232EESE+ ピン構成
| ピン 1 | C1+ — Charge-pump capacitor positive terminal |
| ピン 2 | V+ — Positive charge-pump output |
| ピン 3 | C1- — Charge-pump flyback capacitor terminal |
| ピン 4 | C2+ — Charge-pump capacitor positive terminal |
| ピン 5 | C2- — Charge-pump flyback capacitor terminal |
| ピン 6 | V- — Negative charge-pump output |
| ピン 7 | T1OUT — First RS-232 driver output |
| ピン 8 | R1IN — First RS-232 receiver input |
| ピン 9 | R2IN — Second RS-232 receiver input |
| ピン 10 | T2IN — Second driver logic input |
| ピン 11 | T2OUT — Second RS-232 driver output |
| ピン 12 | R2OUT — Second receiver logic output |
| ピン 13 | GND — Device ground |
| ピン 14 | R1OUT — First receiver logic output |
| ピン 15 | T1IN — First driver logic input |
| ピン 16 | VCC — Positive supply voltage |
主な用途
MAX3232EESE+ の用途: 6 件s: Industrial Controller Serial Port, Programmable Logic Controller Link, Test and Measurement Instrumentation, Point-of-Sale Terminal Interface, Embedded UART-to-RS-232 Bridge, Remote Monitoring and Telemetry.
Industrial Controller Serial Port
The MAX3232EESE+ fits industrial controller service ports that connect a UART-based controller to an RS-232 console or peripheral. Its two drivers and two receivers support bidirectional communication without an external negative supply, while the 3.0 V to 5.5 V operating range accommodates both 3.3 V and 5 V controller families. Operation up to 1 Mbps covers conventional point-to-point serial links, and the MAX3232E family's ±15 kV ESD rating adds useful protection when service cables are connected in industrial environments. Place the four 0.1 µF charge-pump capacitors close to their pins, provide a low-impedance ground path, and verify that the UART logic polarity matches the inverting RS-232 line interface before field deployment.
おすすめ
Programmable Logic Controller Link
A PLC or industrial automation controller can use the MAX3232EESE+ to translate logic-level UART signals into an RS-232 connection for programming software, diagnostics, or a remote service unit. The device's two transmit and two receive channels provide full-duplex capability while eliminating the need for a separate negative supply. Its 1 Mbps maximum data rate exceeds the throughput of many legacy PLC serial links, and ±15 kV ESD protection is valuable around machinery and frequently serviced connectors. The important design trade-off is the inverting RS-232 logic convention: software must account for signal polarity, and charge-pump capacitors must follow the manufacturer layout to keep conversion noise and supply disturbance controlled.
おすすめ
Test and Measurement Instrumentation
The MAX3232EESE+ is appropriate for bench instruments and portable analyzers that expose an RS-232 control or data port. A single 3.0 V to 5.5 V supply supports the transceiver's internal charge pump, reducing system complexity compared with an RS-232 implementation requiring a negative rail. Two drivers and two receivers enable command and response paths, while rates up to 1 Mbps support rapid measurement transfer and firmware updating. The low-power MAX3232E receiver option, with current down to 10 nA, can reduce consumption when a port must remain monitored. Keep the RS-232 traces away from precision analog inputs and use the manufacturer's four-capacitor charge-pump layout to prevent converter ripple from degrading measurement accuracy.
おすすめ
Point-of-Sale Terminal Interface
Retail terminals can use the MAX3232EESE+ for an RS-232 connection to a receipt printer, reader, or service computer. The device requires only a 3.0 V to 5.5 V supply and integrates the charge pump needed to generate RS-232 line voltages. Two transmit and two receive channels support simultaneous command and status traffic, and the 1 Mbps capability allows faster transaction exchanges than legacy serial links. The MAX3232E family's ±15 kV ESD protection helps a terminal withstand charged cable contact during installation and service. Designers should still use a connector with suitable mechanical retention, maintain a common ground with the attached peripheral, and confirm that the host software accounts for RS-232 inversion.
おすすめ
Embedded UART-to-RS-232 Bridge
The MAX3232EESE+ is well suited to embedded systems that need to expose a microcontroller UART through a wired RS-232 port. Its low-voltage operation fits modern 3.3 V processor systems, and the integrated charge pump removes the need for a discrete negative rail. The two-channel transceiver supports both command and diagnostic paths, while up-to-1-Mbps operation can shorten transfer time for logs or firmware. The ±15 kV ESD rating adds connector robustness in equipment that may be repeatedly serviced. The principal implementation constraints are logic inversion, grounding, and charge-pump layout; follow the manufacturer reference circuit and place the four 0.1 µF capacitors close to the IC to minimize supply noise.
おすすめ
Remote Monitoring and Telemetry
The MAX3232EESE+ can provide a wired RS-232 telemetry link between a monitoring controller and remote equipment. The low-power receiver characteristic, with supply current down to 10 nA, is useful when the monitoring port must remain active without continuously driving the link. Two receivers permit two incoming status signals, and two drivers support outbound commands or acknowledgments. A 3.0 V to 5.5 V supply range simplifies integration with embedded controllers, while the MAX3232E family's ±15 kV ESD protection helps manage incidental electrostatic discharge on field cables. Long cable runs still require careful grounding and protection planning, and the 1 Mbps specification should be treated as a maximum device capability rather than a guarantee for an arbitrary cable and connector configuration.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: MAX3232EESE+ — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | MAX3232ESE+ | MAX3232EESE+T | MAX232ESE | MAX242ESE |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC |
| Transmitter Channels | 2 | 2 | 2 | 2 | 2 |
| Receiver Channels | 2 | 2 | 2 | 2 | 2 |
| ESD Protection | ±15 kV | Not specified in the product listing | ±15 kV | Not specified in the product listing | Not specified in the product listing |
主な差別化要因
- Documented connector-side ESD protection (vs MAX3232ESE+)
- Low-power monitoring capability (vs MAX232ESE)
- Single low-voltage supply implementation (vs MAX242ESE)
- High-speed full-duplex interface (vs MAX3232ESE+)
設計ノート
Place all four 0.1 µF charge-pump capacitors close to their designated MAX3232EESE+ pins and keep the associated traces short. The charge-pump converter can couple switching activity into the supply if the capacitor loop is large. Follow the Analog Devices reference layout, provide a solid ground connection, and avoid routing RS-232 driver outputs directly beneath sensitive analog or clock traces.
RS-232 logic is inverted relative to many UART signals, and the MAX3232EESE+ does not remove that convention. Verify transmitter and receiver polarity in software or external circuitry before connecting a peer device. Also distinguish the E version from the standard MAX3232 version: the E family is specified with ±15 kV ESD protection, so a replacement should be reviewed for connector protection rather than accepted solely by pin appearance.
Do not assume that the device's 1 Mbps rating guarantees reliable operation over every cable length or connector. RS-232 is intended primarily for point-to-point links, and long or poorly terminated cables can introduce distortion, reflections, and ground offsets. Keep the interface ground connected to the equipment reference, use a suitable connector, and validate signal integrity with an oscilloscope across the full intended baud rate and cable configuration.
The MAX3232EESE+ needs only a 3.0 V to 5.5 V positive supply because its internal charge pump creates the negative RS-232 voltage. Nevertheless, the charge-pump return current appears as ripple on VCC. Decouple the supply near the device, keep the ground return compact, and avoid sharing narrow supply paths with analog circuitry when the interface drives frequent data transitions.
コンプライアンス情報
The MAX3232E product information identifies the device as production and specifies ±15 kV ESD protection, but separate RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations were not established for the exact ordering code.