MC14536BCP - 2MHz Programmable Timer | onsemi
部品番号: MC14536BCP ✓ 生産中MC14536BCP 概要
A programmable timer is a timing and counting semiconductor used to divide a clock, generate a delayed or fixed-duration pulse, and organize periodic events in digital systems. In the broader hierarchy, the MC14536BCP belongs to the clock and timing IC category, where it combines counter, oscillator-interface, and monostable functions. Selectable counter stages let a system obtain several timing periods from one input frequency without requiring a separate divider for each interval.
The principal functional attributes are its 24-stage binary ripple-counter organization, 16 binary-selectable stages, support for either the internal RC timing path or an external clock input, and a monostable output path. The listed 2 MHz frequency identifies the device’s stated operating-speed class. Together, these features allow the MC14536BCP to cover repetitive timing, pulse generation, elapsed-time measurement, and clock-frequency division functions in one circuit.
The counter architecture provides a direct relationship between input-clock frequency and selected output period. When a stage is selected, the associated ripple-counter output changes at a predictable fraction of the incoming clock. The monostable section adds a separate pulse-duration function, allowing the same timer IC to serve both periodic counting and event-triggering requirements. External timing components can be used with the RC oscillator path, while an external clock gives the circuit a reference with independently controlled accuracy and stability.
Typical applications include industrial pulse and delay generation, test and measurement sequencing, laboratory timer circuits, control-system event counters, low-speed clock dividers, and embedded logic that needs a selectable output period. In these systems, the binary stage-selection inputs determine the timing ratio, while the clock source determines the absolute operating frequency and accuracy. The integrated monostable function is particularly useful when a load must receive a defined pulse after a triggering event.
Designers should verify the power-supply limits, oscillator-component tolerances, timing limits, output characteristics, and absolute maximum ratings in the manufacturer datasheet before finalizing a circuit. External clock and reset timing must also be checked against the system requirement, because the programmable divider changes frequency but does not improve the accuracy of its time reference. PCB layout should keep timing-node connections short and provide adequate decoupling near the device.
This product summary combines the manufacturer architecture description with package, function, sourcing, replacement, and design guidance. It focuses on the practical role of the selectable counter stages, the choice between RC and external-clock timing, and the constraints that must be checked when reusing an existing 16-pin timer design.
ドロップイン代替品: MC14536BCP — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: MC14536BCP (同一形状・フットプリント) — 相違点: Product Type.
この製品に利用可能なドロップイン代替品はありません。
代替品をリクエストMC14536BCP 仕様
| Product Type | Programmable timer IC |
| Maximum Stated Clock Frequency | 2 MHz |
| Counter Architecture | 24-stage binary ripple counter |
| Selectable Counter Stages | 16 stages |
| Stage Selection Method | Binary code |
| Oscillator Options | On-chip RC oscillator or external clock |
| Monostable Function | On-chip monostable with pulse-type output |
| パッケージ | 16-pin PDIP |
| ピン数 | 16 pins |
| 実装タイプ | Through-hole |
MC14536BCP 16-pin pdip ピン配置ガイド
MC14536BCP (16-pin pdip パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: MC14536BCP.
詳細は データシート をご参照ください。
主な用途
MC14536BCP の用途: 6 件s: Programmable Clock Divider, Industrial Pulse Generator, Test and Measurement Sequencing, Laboratory Timer Circuit, Elapsed-Time Counter, Embedded Control Event Timer.
Programmable Clock Divider
The MC14536BCP fits clock-divider designs that require several timing ratios from one reference. Its 24-stage binary ripple-counter architecture includes 16 stages selectable through a binary control code, allowing the selected output to run at a defined fraction of the input clock. The external-clock option lets the system preserve the precision and stability of a shared oscillator rather than relying on discrete RC tolerances. In a design using the 2 MHz device class, the selected divider stage determines the resulting output frequency, while the source clock remains the primary accuracy reference. This arrangement reduces the number of separate counters needed when several periodic signals must share one master timebase.
おすすめ
Industrial Pulse Generator
The MC14536BCP is appropriate for industrial pulse-generation circuits that need selectable timing intervals and a controlled trigger output. Binary stage selection determines the counting interval, while the integrated monostable section can create a pulse-type output after a triggering event. This arrangement is useful when a controller must activate a load, update a display, or advance a process step for a defined time. Designers should account for clock-edge behavior, reset timing, and output pulse characteristics in the manufacturer datasheet. Because the device supports an external clock, the pulse timing reference can remain independent of the logic system’s internal oscillator.
おすすめ
Test and Measurement Sequencing
The MC14536BCP can organize repeatable timing intervals in test and measurement equipment. Sixteen selectable counter stages provide multiple division choices from one clock source, while the monostable path supports trigger pulses that coordinate measurement or capture events. An external clock can establish a traceable time reference when accuracy and repeatability are more important than autonomous RC timing. In an instrument, the counter-selection logic may be driven by test-control circuitry, and the pulse output can initiate a measurement sequence, sample window, or relay command. PCB design should isolate the timing path from noisy analog and switching sections while maintaining the decoupling and grounding practices specified by the manufacturer.
おすすめ
Laboratory Timer Circuit
The MC14536BCP provides a compact solution for laboratory timers that require selectable count intervals and a triggerable output pulse. The on-chip RC oscillator permits a self-contained timing circuit when the required tolerance is acceptable, while an external clock offers improved frequency control. Binary selection lets a user or control system choose among 16 available counter stages, reducing the need for multiple physical timer circuits. The monostable output can energize an indicator or initiate another instrument when the selected interval expires. For dependable operation, calculate the expected timing value from the selected stage and clock frequency, then verify oscillator component tolerances and output pulse limits against the application requirements.
おすすめ
Elapsed-Time Counter
The MC14536BCP is suitable for elapsed-time counting when a system must accumulate clock pulses and present an event at a selected interval. Its binary ripple-counter structure allows the design to choose among 16 programmable stages, creating a practical relationship between the input frequency and the desired update interval. A monostable output can provide a defined pulse when the selected count is reached. External-clock operation is advantageous when the timer must share the accuracy of a system reference rather than use local RC components. Designers should ensure that reset and control inputs meet the required pulse-width and logic-level conditions and should verify whether the intended output is a continuous divided signal or a single pulse.
おすすめ
Embedded Control Event Timer
The MC14536BCP can provide a dedicated timing channel in an embedded control assembly where the main processor requires a simple hardware interval event. The selected ripple-counter stage divides an incoming clock, and the monostable path generates a pulse after the chosen delay, allowing the controller to handle a recurring or one-shot action without reproducing the timing function in software. This is particularly useful in legacy or mixed analog-digital equipment where an added counter IC is simpler than modifying the central controller. Supply limits, logic thresholds, clock-edge requirements, and output timing tolerances must be reviewed in the manufacturer datasheet, and the timing net should be routed away from high-current switching nodes.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: MC14536BCP — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 |
|---|---|
| Brand | onsemi |
| Package | 16-pin PDIP |
| Product Type | Programmable timer IC |
| Maximum Stated Clock Frequency | 2 MHz |
| Counter Stages | 24 stages |
| Selectable Stages | 16 stages |
| Stage Selection | Binary code |
| Timing Sources | On-chip RC oscillator or external clock |
| Monostable Output | Pulse-type output |
| Mounting Type | Through-hole |
主な差別化要因
- Combines a programmable counter with a monostable timing path (vs Basic binary ripple-counter ICs)
- Supports two timing-source strategies (vs Fixed external-clock-only counters)
- Provides programmable timing ratios without multiple divider packages (vs Discrete fixed-divider implementations)
設計ノート
Confirm the device’s supported supply-voltage range, input thresholds, and output-drive limits in the onsemi datasheet before connecting it to surrounding logic. Place the required bypass capacitor close to the supply and ground pins, and route it using a short, low-loop path. If the timer shares a board with relays, motors, or high-current switching stages, prevent supply transients from coupling directly into the timing reference.
Keep the external-clock and RC oscillator nodes compact and isolate them from switching-node copper. The clock source must satisfy the manufacturer’s edge-rate and pulse-width requirements, while reset and stage-selection lines must not experience excessive ringing. When using a shared reference clock, terminate and route it according to the clock source’s requirements to avoid double counting, missed edges, or unstable divider outputs.
Do not assume that changing a selected counter stage changes oscillator accuracy; the stage determines the division ratio, while the RC components or external clock determine the timing reference. Verify the selected-stage table and output polarity before implementing system logic. Also confirm reset behavior because an incorrect reset pulse or asynchronous-control assumption can cause the counter and monostable sections to operate differently from the intended sequence.
The 16-pin PDIP package is suited to through-hole assembly, but signal integrity still depends on sensible placement. Keep timing inputs away from high-voltage or switching traces, provide a solid ground return, and avoid long parallel routes between adjacent clock and control signals. Inspect the assembled board for solder bridges and pin-1 orientation because incorrect socket or board orientation can connect the oscillator or control inputs to unintended levels.
コンプライアンス情報
The manufacturer datasheet identifies the MC14536B family, but the available product information does not explicitly state the target suffix’s RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 qualification is not indicated for this general-purpose timer.