4.5 V to 5.5 V Vdss 14-SOIC Package
MOQ: 1 |

MC33199D 概要

The NXP MC33199D is an ISO 9141 automotive diagnostic serial interface circuit with one driver and one receiver, designed for a 4.5 V to 5.5 V supply and packaged in a 14-SOIC. The device connects a vehicle microcontroller to the special K and L lines of an ISO diagnostic port. It provides a bidirectional K-line driver, an L-line receiver used during wake-up sequences, short-circuit protection for the K line, and over-temperature protection.

An ISO 9141 interface is a dedicated diagnostic communication interface within the broader automotive network. ISO 9141 uses separate K and L conductors rather than a conventional multidrop CAN bus. The K line carries the main diagnostic communication waveform, while the L line helps establish the wake-up sequence. The MC33199D functions as the physical-layer interface between a microcontroller UART and these vehicle-network lines.

Key specifications include 1 driver and 1 receiver, a 4.5 V to 5.5 V operating supply range, ISO 9141 protocol support, and a 14-SOIC package measuring 3.90 mm wide. The K-line driver is bidirectional and protected against short circuits and excessive temperature. The L-line receiver supports the diagnostic wake-up sequence, allowing the host controller to recognize and respond to bus activity.

The MC33199D simplifies implementation of an ISO 9141 diagnostic port because the MCU can communicate through ordinary serial logic levels while the IC handles the vehicle K and L lines. Its single-driver, single-receiver arrangement is appropriate for one diagnostic channel. Protection of the K-line output reduces the risk of damage from an inadvertent bus short, although the external vehicle wiring, pull-up network, connector, and transient environment still require careful engineering.

Typical applications include automotive diagnostic interfaces, engine-control units, transmission controllers, body-control modules, garage-door and service-tool testers, and other embedded systems that emulate or access ISO 9141 diagnostic ports. The device is most appropriate for legacy diagnostic systems rather than new designs centered on CAN, CAN FD, or LIN.

When designing around the MC33199D, verify the K-line and L-line interface network, supply decoupling, grounding, and protection required by the vehicle platform. The 5 V supply range excludes direct 3.3 V operation. Because the part is identified as obsolete in the available replacement information, engineers should also evaluate the NXP-recommended MC33660B replacement against footprint, protocol, timing, and protection requirements before committing to a redesign.

This product summary consolidates the verified protocol, electrical, package, lifecycle, replacement, pricing-reference, and design information for engineers evaluating the MC33199D. It also distinguishes verified values from specifications that require confirmation from the manufacturer datasheet, avoiding unsupported assumptions about pin assignments or unqualified substitutes.

ドロップイン代替品: MC33199D — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

MC33199

✅ ドロップイン
📦 14-SOIC
Base-orderable MC33199 variant; the verified excerpt does not quantify any electrical or timing differences from MC33199D

📋 参考代替品(カタログ未掲載)

MC33199D 仕様

Product Type Automotive ISO 9141 serial interface circuit
Protocol ISO 9141
Number of Drivers 1
Number of Receivers 1
Driver Type Bidirectional K-line driver
Receiver Function L-line receiver for ISO 9141 wake-up sequence
Supply Voltage Range 4.5 V to 5.5 V
パッケージ 14-SOIC
Package Width 3.90 mm
Package Length 0.154 inch
実装タイプ Surface mount
Packaging Cut tape
Short-Circuit Protection Protected on the K-line driver
Over-Temperature Protection Yes

MC33199D 0.154 inch ピン配置ガイド

MC33199D (0.154 inch パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。

MC33199D の 0.154 inch パッケージピン配置図

詳細なピン配置データはありません: MC33199D.

詳細は データシート をご参照ください。

主な用途

MC33199D の用途: 6 件s: Automotive Diagnostic Interfaces, Engine Control Unit Diagnostics, Vehicle Service Diagnostic Tools, Body Control Module Diagnostics, Transmission Controller Diagnostics, Industrial Legacy Vehicle Test Equipment.

🚗

Automotive Diagnostic Interfaces

The MC33199D fits legacy ISO 9141 diagnostic interfaces that connect a vehicle microcontroller to the K and L lines of a service connector. Its bidirectional K-line driver carries the principal diagnostic waveform, while the L-line receiver supports the wake-up sequence. The verified 4.5 V to 5.5 V supply range requires a regulated 5 V rail, and the 14-SOIC package simplifies integration with existing 5 V automotive controller boards. Because the part is obsolete, new production designs should first compare it with the NXP-recommended MC33660B and verify that the replacement footprint and electrical behavior satisfy the complete interface design.

🚗

Engine Control Unit Diagnostics

The MC33199D can provide the ISO 9141 physical interface within an engine-control unit or legacy powertrain controller. The microcontroller drives and receives diagnostic signals through the K line, while the L receiver detects the established wake-up condition before communication begins. Its 4.5 V to 5.5 V operating range suits regulated 5 V control electronics, and the K-line driver includes short-circuit and over-temperature protection. In a safety- or lifecycle-sensitive production program, engineers should confirm automotive qualification, temperature limits, diagnostic timing, and the suitability of the NXP-recommended MC33660B before new design entry.

🔧

Vehicle Service Diagnostic Tools

The MC33199D is applicable to service equipment that emulates or communicates with an ISO 9141 vehicle diagnostic port. It isolates the host controller from the K and L conductors through a dedicated interface IC and provides a bidirectional K-line driver with short-circuit and thermal protection. The 5 V supply requirement means the tester must provide a regulated 4.5 V to 5.5 V source for this circuit section. For newly designed tools, the MC33660B should be evaluated as the NXP-recommended replacement, with package, pin mapping, electrical thresholds, and wake-up behavior verified against the target vehicle protocols.

🚗

Body Control Module Diagnostics

The MC33199D can support an ISO 9141 diagnostic connection in a body-control module or other distributed automotive controller. The device provides one bidirectional K-line driver and one L-line receiver, allowing the module microcontroller to participate in the vehicle wake-up and diagnostic exchange sequence. Protection against K-line short circuits and excessive driver temperature improves robustness, although vehicle-level transient requirements still govern external circuitry. The 14-SOIC package fits established controller layouts, but an obsolete designation makes supply assurance important. For new platforms, compare the MC33660B and verify that its package and pin requirements permit a straightforward redesign.

🚗

Transmission Controller Diagnostics

The MC33199D is suitable for legacy transmission electronics that expose an ISO 9141 diagnostic port to service equipment. The interface separates the controller's serial signaling from the physical K and L vehicle lines, while the bidirectional K-line driver supports both transmitting and receiving diagnostic messages. The L receiver participates in the wake-up sequence, helping the controller transition from a low-power state when appropriate bus activity is detected. The regulated 5 V supply requirement and 14-SOIC footprint favor retrofitting existing designs. For new transmission-control platforms, engineers should assess MC33660B and verify every pin and timing requirement rather than assuming a literal drop-in conversion.

🏭

Industrial Legacy Vehicle Test Equipment

The MC33199D can be used in test and diagnostic equipment designed for legacy vehicles that still employ ISO 9141. The interface gives a controller access to the K and L diagnostic conductors, with the K driver handling bidirectional signaling and the L receiver supporting wake-up detection. Its 4.5 V to 5.5 V supply range is compatible with conventional 5 V test-system logic, and the 14-SOIC package is convenient for existing boards. Because the verified source identifies the MC33199D as obsolete, equipment manufacturers should qualify the NXP-recommended MC33660B for new products and maintain MC33199D only where PCB continuity and genuine component traceability justify it.

What is the MC33199D and what does it do?
The MC33199D is an ISO 9141 serial interface circuit used to connect a microcontroller with the K and L lines of an automotive diagnostic port. According to the manufacturer datasheet, it contains one bidirectional K-line driver and one L-line receiver, operates from a 4.5 V to 5.5 V supply, and is available in a 14-SOIC package. The L-line receiver supports the wake-up sequence.
What are the key specifications of MC33199D that engineers should know?
The MC33199D provides one driver and one receiver for ISO 9141 automotive diagnostic communication. Verified specifications identify a 4.5 V to 5.5 V supply range and a 14-SOIC surface-mount package measuring 3.90 mm wide. Its bidirectional K-line output includes short-circuit and over-temperature protection, while its L-line receiver handles the diagnostic wake-up sequence.
What is the supply voltage of the MC33199D?
The MC33199D operates from 4.5 V to 5.5 V. According to the MC33199D specification listing, this supply range applies to the 14-SOIC device with one driver and one receiver. A design that provides only 3.3 V cannot operate the interface directly without an appropriate external supply arrangement or a different supported transceiver.
What package does the MC33199D use?
The MC33199D uses a 14-SOIC surface-mount package measuring 0.154 inch, or 3.90 mm, wide. DigiKey also identifies the device as a 14-SOIC ISO 9141 driver. Because this package contains 14 leads, any replacement must match the footprint and pin assignment rather than merely provide similar protocol functionality.
Where can I download the MC33199D datasheet PDF?
The MC33199D datasheet PDF is available from the manufacturer-document archive at https://www.datasheets.com/motorola/mc33199d/datasheet.pdf. It describes the device as an ISO 9141 serial interface between a microcontroller and the diagnostic-port K and L lines. The PDF should be used for final pin, electrical-limit, timing, and protection details before layout or schematic release.
Where can I find the MC33199D pinout?
The MC33199D pinout is published in the manufacturer datasheet linked from the product documentation. The available search results confirm a 14-SOIC package but do not provide a verified pin-by-pin connection table, so this page does not reproduce potentially incorrect pin assignments. Download the datasheet and map every supply, ground, MCU, K-line, and L-line connection before PCB layout.
Is MC33199D in stock, and what is its price?
The MC33199D is listed for purchase by DigiKey, but the supplied verified data does not contain a current numeric price or an explicit stock quantity. Its lifecycle is identified as obsolete in the available NXP replacement discussion. Prices and availability therefore remain unverified as of 2026-10-29; contact XAIPART for a quotation and confirmed allocation rather than relying on the placeholder zero values shown for unavailable price tiers.
Where can I buy the obsolete MC33199D online?
DigiKey lists the MC33199D for purchase at its NXP product page, while several document archives retain the original manufacturer datasheet. The verified results do not establish a stable inventory position or a current unit price as of 2026-10-29. Because an NXP community response identifies the device as obsolete, buyers should request traceability details, date codes, condition, and written availability confirmation before placing an order.
What is the lead time for MC33199D?
A numeric lead time for MC33199D is not present in the verified web data. The part is identified as obsolete, so any available stock may be limited to existing distribution inventory rather than new production. As of 2026-10-29, request a manufacturer-authorized quotation that states the lead time, package quantity, date code, and whether the devices are new or reclaimed before committing the quantity to a build.
What can replace the MC33199D?
NXP community guidance identifies the MC33660B as the correct replacement for the MC33199D. This establishes functional replacement intent, but it does not by itself prove a drop-in substitution in the 14-SOIC footprint. Before exchanging devices, compare package dimensions, pin mapping, supply range, ISO 9141 electrical levels, K-line protection, L-line wake-up behavior, timing, and automotive qualification.
Is MC33199D the same as MC33660B?
No. The MC33199D is an ISO 9141 interface in a 14-SOIC package, while NXP community guidance identifies MC33660B as its replacement rather than an identical part. The available cross-reference evidence does not confirm identical pinout or package compatibility. Treat MC33660B as a redesign candidate until its datasheet has been checked against every connection and electrical requirement of the original circuit.
MC33199D vs MC33660B: which is better for an ISO 9141 diagnostic port?
MC33660B is the preferred choice for a new ISO 9141 design because NXP community guidance identifies it as the replacement for the obsolete MC33199D. MC33199D remains useful when preserving an existing 14-SOIC PCB is mandatory and verified original stock is available. The decision should account for package changes, pin mapping, electrical limits, protection, timing, and lifecycle rather than assuming drop-in equivalence.
When should I choose MC33199D over MC33660B?
Choose the MC33199D only when an existing 14-SOIC board cannot be revised and genuine, traceable original stock is available. For new automotive diagnostic hardware, choose the NXP-recommended MC33660B after confirming that its electrical behavior and package meet the system requirements. The MC33199D offers no verified lifecycle advantage and is explicitly described as obsolete in the available replacement information.
Is MC33199D suitable for automotive diagnostic equipment?
The MC33199D is suitable for legacy ISO 9141 diagnostic-port implementations that use a 5 V supply and a 14-SOIC interface. It supports a bidirectional K line, an L-line wake-up receiver, and driver short-circuit and thermal protection. However, the available data does not verify its exact automotive qualification status, so a production vehicle program must confirm AEC-Q100 status and all environmental requirements.
Does MC33199D provide K-line short-circuit protection?
Yes. The verified device description states that the MC33199D has a bidirectional K-line driver protected against short circuits and over-temperature conditions. This protection is valuable in automotive diagnostic wiring, where an external fault or unintended low-resistance connection can stress the interface. It does not remove the need for suitable external protection and correct PCB layout around the bus connection.
What standards and technologies are associated with MC33199D?
The MC33199D is associated with the ISO 9141 diagnosis-system interface specification and is implemented as a 4.5 V to 5.5 V automotive serial interface IC. The verified data confirms ISO 9141 protocol support, one bidirectional K-line driver, one L-line receiver, and K-line short-circuit and thermal protection. Other compliance claims, including RoHS, REACH, and AEC-Q100 status, are not established by the supplied excerpts.

エンジニアリング参考データ: MC33199D — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the MC33199D only when maintaining an existing 14-SOIC ISO 9141 circuit is more important than securing a current lifecycle, and when original MC33199D devices can be obtained with acceptable traceability. Its integrated bidirectional K-line driver, L-line wake-up receiver, and protected output make it suitable for legacy diagnostic systems operating from a regulated 4.5 V to 5.5 V supply. For new automotive products, evaluate MC33660B because NXP community guidance identifies it as the correct replacement, while the MC33199 is a base-orderable same-family option when its exact ordering configuration and pinout are confirmed. Do not select either part solely by protocol label: verify footprint, pin mapping, electrical thresholds, timing, temperature range, protection, automotive qualification, and lifecycle against the original schematic.

代替品との比較

パラメータ この製品 MC33199
Product Type ISO 9141 serial interface circuit ISO 9141 serial interface circuit
Brand NXP NXP
Package 14-SOIC 14-SOIC
Protocol ISO 9141 ISO 9141
Number of Drivers 1 1
Number of Receivers 1 1
Supply Voltage Range 4.5 V to 5.5 V 4.5 V to 5.5 V
Driver Function Bidirectional K-line driver Bidirectional K-line driver
Receiver Function L-line receiver for wake-up sequence L-line receiver for wake-up sequence
Short-Circuit Protection Yes, on K-line driver Yes, on K-line driver

主な差別化要因

  • Integrated ISO 9141 physical interface (vs MC33199)
  • Protected automotive K-line output (vs MC33199)
  • Defined 5 V operating range (vs MC33199)

設計ノート

Do not treat MC33660B as a confirmed pin-for-pin substitute solely because NXP community guidance identifies it as the replacement for MC33199D. Download the applicable device datasheets and compare package dimensions, pin mapping, supply limits, K-line and L-line thresholds, driver topology, wake-up timing, and protection behavior. The supplied evidence confirms replacement intent but does not establish identical footprint compatibility.

The MC33199D requires a 4.5 V to 5.5 V supply, so a 3.3 V MCU cannot power it directly without an appropriate interface or level-shifting arrangement. Place the device's supply decoupling close to its VDD and ground pins, maintain a low-impedance return path, and verify supply tolerance during vehicle cranking and transient conditions. Voltage limits not stated in the verified excerpts must be confirmed from the manufacturer datasheet.

Route the K and L connections away from sensitive MCU signals and keep the external interface network close to the IC and connector. Use a ground plane without excessive splitting beneath the device, minimize loop area in the bus path, and apply the manufacturer's recommended pull-up or termination values. Because the exact reference circuit and pinout were not included in the verified data, consult the datasheet before finalizing component values or trace geometry.

The verified K-line driver includes short-circuit and over-temperature protection, but protection does not eliminate thermal design and layout responsibility. Check the worst-case driver dissipation under sustained fault conditions, maintain copper area around the 14-SOIC leads and exposed thermal pathways if specified, and confirm the device temperature rating from the datasheet. The available data does not provide thermal resistance or maximum junction temperature, so those values must not be assumed.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

The supplied verified excerpts establish an ISO 9141 automotive diagnostic interface and protected K-line operation but do not provide verified RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations. These fields remain unknown rather than being inferred from the application's automotive use.

関連検索

MC33199D datasheet NXP MC33199D MC33199D ISO 9141 interface MC33199D 14-SOIC pinout MC33199D 4.5V 5.5V supply MC33199D automotive diagnostic interface MC33199D vs MC33660B MC33199D drop-in replacement MC33199D buy price MC33199D obsolete replacement ISO 9141 K line L line interface IC where to buy MC33199D online

関連部品&用語

NXP Freescale Semiconductor Motorola MC33199D MC33199 MC33660B ISO 9141 automotive diagnostic interface serial interface IC interface transceiver IC bidirectional K-line driver L-line receiver wake-up sequence 4.5 V to 5.5 V power supply 14-SOIC package SOIC family surface-mount device short-circuit protection over-temperature protection vehicle diagnostic port K line L line automotive electronics RoHS REACH AEC-Q100
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示