NQ442L2C - 225A NQ Panelboard Interior, 42-Pole | Schneider Electric
部品番号: NQ442L2C ✓ 生産中| 数量 | 単価 | 小計 |
|---|---|---|
| 1 | $542 | $542.00 |
| 5 | $488 | $2,440.00 |
| 10 | $435 | $4,350.00 |
| 25 | $388 | $9,700.00 |
| 50 | $352 | $17,600.00 |
NQ442L2C 概要
A panelboard interior is the central assembly of a power distribution panelboard that mounts the bus structure, branch breakers, and neutral/ground hardware inside an enclosure. In the taxonomy of electrical distribution hardware, panelboards sit beneath switchboards and loadcenters, distributing power from a feeder or transformer to final branch circuits. NQ panelboards are the workhorse of North American light-commercial and industrial power distribution, with cULus listing for both US and Canadian installations.
Key features of the NQ442L2C include 42 branch-circuit pole spaces, 225 A main lugs, copper bus bars for lower voltage drop and superior thermal performance versus aluminum, and convertible main-lug/main-breaker construction. The interior mounts in standard Square D NQ enclosures and accepts the QO/QOB branch breaker family, the widest breaker offering of any North American panelboard line.
Typical applications include 240 VAC three-phase feeder distribution in office buildings, retail spaces, light-industrial plants, healthcare clinics, data-center row power distribution, and as a sub-panel in larger electrical rooms. The NQ442L2C is interchangeable with other NQ 42-circuit interiors when installing, replacing, or expanding existing Square D installations.
When designing with NQ442L2C, derate the bus per NEC Article 408 when more than 42 circuits of breakers at 100% are present - total breaker handle count can exceed 42. Provide adequate enclosure ventilation for continuous 225 A operation.
ドロップイン代替品: NQ442L2C — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
クイック比較ツール — 並列比較する代替部品を選択:
NQ454L2C
✅ ドロップイン📋 参考代替品(カタログ未掲載)
NQ442L4C
✅ ドロップイン📋 参考代替品(カタログ未掲載)
NQ430L2C
✅ ドロップイン📋 参考代替品(カタログ未掲載)
NQ442L2C-N
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
NQ442L2C-CUL
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
NQ442L2C 最大定格&電気的特性
| Product Type | Panelboard Interior |
| ブランド | Schneider Electric / Square D |
| Series | NQ |
| Main Ampere Rating | 225 A |
| Number of Pole Spaces | 42 |
| Bus Material | Copper (Cu) |
| Main Type | Main Lugs (convertible to Main Breaker) |
| Phases | 3 Phase |
| Wires | 4 Wire |
| Voltage Rating (AC) | 240 VAC |
| Voltage Rating (DC) | 48 VDC |
| Compatible Breakers | QO, QOB bolt-on |
| Neutral Rating | 200% rated for non-linear loads |
| Standards | cULus (US and Canada) |
| Mounting | Surface or Flush enclosure |
| 在庫状況 | Normally stocked in distribution facility |
NQ442L2C standard ピン配置ガイド
NQ442L2C (standard パッケージ) のピン配置。 このパワーデバイスは、ゲート、ドレイン、ソース端子を備えています。非極性パッケージの場合、正確なピン1の向きとフットプリントの詳細については、メーカーのデータシートを参照してください。主な用途には、電源設計、モータ駆動、負荷スイッチングがあります。
詳細なピン配置データはありません: NQ442L2C.
詳細は データシート をご参照ください。
主な用途
NQ442L2C の用途: 6 件s: Light-Commercial Office Building Distribution, Retail Store Power Distribution, Healthcare Clinic Sub-Panel, Data Center Row Power Distribution, Light-Industrial Motor Control Center Feeder, K-12 School Classroom Building Distribution.
Light-Commercial Office Building Distribution
The NQ442L2C delivers 240 VAC three-phase power to lighting, receptacle, and HVAC loads across office floors in light-commercial buildings. Its 225 A copper bus at 42 pole spaces is the standard capacity for 5,000-15,000 sq ft office suites where each circuit feeds a 20 A receptacle run or a 1.5 kW class LED lighting string. Copper bus versus aluminum drops the bus temperature rise by roughly 30%, allowing the interior to live in a flush-mounted closet without active cooling even at 80% continuous load.
おすすめ
Retail Store Power Distribution
Retail outlets use the NQ442L2C to feed merchandising aisles, walk-in coolers, signage transformers, and HVAC rooftop units from a single 225 A service. The 240 VAC 3-phase bus lets the store run higher-efficiency 3-phase compressors on refrigeration while 120 VAC single-phase from the same panel feeds general lighting and point-of-sale receptacles. The Square D QOB bolt-on branch breakers used here survive constant plugging and unplugging common in tenant buildouts.
おすすめ
Healthcare Clinic Sub-Panel
Clinics and small medical offices depend on the NQ442L2C for reliable 240 VAC sub-distribution to exam rooms, imaging suites, and emergency lighting inverters. The 200% rated neutral handles harmonic content from modern diagnostic imaging loads (MRI gradient amps, X-ray rectifiers) without nuisance neutral overheating. cULus listing under both US and Canadian standards supports cross-border healthcare construction without re-specifying the panelboard.
おすすめ
Data Center Row Power Distribution
In distributed data center designs, the NQ442L2C serves as the row-level power distribution node that steps 480 VAC three-phase down to 240 VAC three-phase for IT rack busways. The 200% neutral is essential here: switch-mode power supplies draw third-harmonic currents that can load neutrals to 150% of phase currents. Copper bus keeps voltage drop under 3% even at full 225 A load, preserving CPU power-supply hold-up margin during transient peaks.
おすすめ
Light-Industrial Motor Control Center Feeder
The NQ442L2C feeds downstream motor control centers and VFD lineups in light-industrial facilities such as packaging plants and warehouses. 240 VAC 3-phase architecture pairs naturally with 240 V three-phase motors up to 15 hp (using inverse-time branch breakers) and reduces losses in feeder runs compared with 120 V single-phase. The convertible main-lug-to-main-breaker design lets the same interior act as service entrance or sub-feed depending on project topology.
おすすめ
K-12 School Classroom Building Distribution
Elementary, middle, and high school classroom buildings use the NQ442L2C to distribute power across wings that house classrooms, computer labs, and cafeteria kitchens. 42 pole spaces support the typical 25-35 branch circuits per classroom wing at 225 A service. cULus listing ensures code compliance in jurisdictions across both US and Canada, and tamper-resistant QO breakers available for the NQ family meet NEC 406.12 for child-occupied facilities.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: NQ442L2C — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | NQ454L2C | NQ442L4C | NQ430L2C |
|---|---|---|---|---|
| Brand | Schneider Electric (Square D) | Schneider Electric (Square D) | Schneider Electric (Square D) | Schneider Electric (Square D) |
| Package | NQ Panelboard Interior (42-pole) | NQ Panelboard Interior (54-pole) | NQ Panelboard Interior (42-pole, 400 A) | NQ Panelboard Interior (30-pole) |
| Main Ampere Rating | 225 A | 225 A | 400 A | 225 A |
| Pole Spaces | 42 | 54 | 42 | 30 |
| Bus Material | Copper | Copper | Copper | Copper |
| Phases / Wires | 3 phase / 4 wire | 3 phase / 4 wire | 3 phase / 4 wire | 1 phase / 3 wire |
| Voltage Rating | 240 VAC / 48 VDC | 240 VAC / 48 VDC | 240 VAC / 48 VDC | 240 VAC / 48 VDC |
| Compatible Breakers | QO / QOB bolt-on | QO / QOB bolt-on | QO / QOB bolt-on | QO / QOB bolt-on |
| Neutral Rating | 200% rated | 200% rated | 200% rated | 200% rated |
主な差別化要因
- 42 pole spaces at 225 A provides balanced capacity for typical commercial loads (vs NQ430L2C)
- Copper bus standard for lower voltage drop and cooler operation (vs Aluminum-bus NQ variants)
- Convertible lug-to-breaker main without replacing the interior (vs Fixed main-lug-only alternatives)
- 200% neutral rating handles harmonic currents from modern IT and LED loads (vs 100% neutral alternatives)
設計ノート
Estimated: at full 225 A continuous load with 240 VAC 3-phase, the NQ442L2C copper-bus interior dissipates approximately 60 W under balanced unity-power-factor loads, with internal bus temperature rises around 30 C above ambient at 100% rated current. Verify enclosure ventilation and that the selected NQ enclosure is rated for the calculated heat load. Square D enclosures come in NEMA 1, 3R, and 12 variants - pair the interior with an enclosure that matches the installation environment.
Copper bus runs ~30% cooler than equivalent aluminum bus at the same current, but at continuous loads above 80% of 225 A (i.e. 180 A), derate per NEC Article 408. Consider upsizing to the NQ442L4C (400 A) for continuous-load applications like data-center row power where loads stay above 180 A for hours. Field-installed main breaker kits (QOM2 series) allow future conversion without replacing the interior.
The NQ442L2C is 'Convertible from main lug to main breaker' - this means the interior ships as main-lugs-only and a QOM2 main breaker kit must be field-installed for service-entrance applications. Forgetting this kit causes a service-entrance installation to fail inspection. Also note that tandem breakers only fit in slot positions designed for tandem mounting - consult the catalog 1640CT0801 panelboard layout diagram before populating circuits.
Plan branch-breaker layout with a dedicated 30-50 A 2-pole for HVAC, a 20-50 A 2-pole for water heater, and only 1-pole 20 A on the lighting/receptacle side. Group high-inrush loads (motors, HVAC compressors) near the main lugs to minimize conductor runs and reduce voltage drop. The interior mounting depth is approximately 6.5 inches; ensure the selected enclosure has adequate wire-bending space per NEC 312.6.
コンプライアンス情報
cULus listed per Schneider Electric product page (standards US and Canada per Square D NQ catalog 1640CT0801). RoHS/REACH status not explicitly stated in the verified web data; RoHS compliance can be confirmed on the Schneider Electric material-declaration portal for this part number.