TCAN332GDCNT - 3.3V 5Mbps CAN FD Transceiver | Texas Instruments
部品番号: TCAN332GDCNT ✓ 生産中TCAN332GDCNT 概要
A CAN transceiver is the physical-layer interface between a host controller and a CAN bus. It converts logic-level transmit and receive signals into differential bus levels, while the receiving path converts differential bus voltage back into a logic signal for the controller. Within the network hierarchy, the TCAN332GDCNT belongs to the CAN transceiver, CAN interface, interface IC, and integrated-circuit product categories.
The TCAN332GDCNT operates from a 3 V to 3.6 V supply and supports CAN and CAN FD communication. Its 5 Mbit/s maximum signaling rate suits controllers using CAN FD for higher payload throughput while retaining compatibility with conventional CAN networks. Shutdown and standby operating modes help reduce power consumption in battery-powered and duty-cycled systems. The transceiver also provides bus-fault protection for bus voltages from -14 V to 14 V.
TI describes the TCAN33x family as compatible with the ISO 11898 high-speed CAN physical-layer standard. Its single-channel, half-transceiver configuration connects one CAN node to a bus, allowing distributed controllers, sensors, actuators, and diagnostic equipment to exchange data reliably over a noisy industrial or vehicle network. The compact SOT-23-8 footprint reduces board area compared with larger SOIC options.
Typical uses include industrial automation controllers, electric-vehicle subsystem gateways, battery-powered sensor nodes, elevator controls, motor drives, and automotive body modules. In each case, the TCAN332GDCNT can condition the controller-to-bus and bus-to-controller signals while protecting the node against common bus transients within the specified -14 V to 14 V range.
Designers should place the transceiver close to the bus connector and provide a controlled CAN bus termination at each end of the network. Keep the CANH and CANL routing symmetrical, avoid long stubs, and follow the PCB layout and protection guidance in the TI TCAN332G datasheet. Verify the device-mode pins and external interface components against the selected controller voltage levels before releasing the PCB.
ドロップイン代替品: TCAN332GDCNT — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: TCAN332GDCNT (同一形状・フットプリント) — 相違点: Operating Temperature Range, Package, Product Type, Transceiver Configuration.
TCAN332DCNT
✅ ドロップイン📋 参考代替品(カタログ未掲載)
TCAN337DCNT
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
TCAN334DCNT
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →TCAN331DCNT
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
TCAN330DCNT
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
TCAN332GDCNT 仕様
| Product Type | High-speed CAN transceiver with CAN FD |
| Supply Voltage Range | 3 V to 3.6 V |
| Nominal Supply Voltage | 3.3 V |
| Maximum Signaling Rate | 5 Mbit/s |
| Bus Fault Voltage | -14 V to 14 V |
| Number of Channels | 1 channel |
| Transceiver Configuration | Half |
| Supported Protocols | CAN, CAN FD |
| Compatibility Standard | ISO 11898 high-speed CAN physical layer |
| 動作温度範囲 | -40 °C to 125 °C |
| パッケージ | 8-pin SOT-23 (DCN) |
| 実装タイプ | Surface mount |
| Low-Power Modes | Shutdown and standby |
TCAN332GDCNT 8-pin sot-23 (dcn) ピン配置ガイド
TCAN332GDCNT (8-pin sot-23 (dcn) パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: TCAN332GDCNT.
詳細は データシート をご参照ください。
主な用途
TCAN332GDCNT の用途: 6 件s: Industrial Automation and Factory Control, Electric Vehicle Subsystem Gateway, Battery-Powered Sensor and IoT Node, Motor Drive and Power Inverter Control, Automotive Body and Comfort Module, Elevator, HVAC, and Building Equipment.
Industrial Automation and Factory Control
The TCAN332GDCNT fits distributed factory-control nodes that connect sensors, motor controllers, and safety equipment to a CAN-based backbone. Its 3.3 V supply range and 5 Mbit/s signaling rate support modern CAN FD controllers, while the -14 V to 14 V bus-fault range adds protection against common industrial transients. Place the transceiver near the field connector, route CANH and CANL as a matched pair, and follow the TI TCAN332G layout guidance to preserve signal integrity.
おすすめ
Electric Vehicle Subsystem Gateway
The TCAN332GDCNT can connect battery-management, inverter, thermal-management, and body-control modules to a vehicle CAN network. Its 5 Mbit/s maximum signaling rate supports CAN FD data transfer, and the -40 °C to 125 °C operating range covers many vehicle compartments. Confirm automotive qualification for the exact orderable part, use only CAN FD-capable controllers, and protect the bus interface according to the TI application recommendations.
おすすめ
Battery-Powered Sensor and IoT Node
The TCAN332GDCNT is suitable for distributed sensor nodes where a low-voltage microcontroller communicates over a short CAN bus. Operation from 3 V to 3.6 V allows direct use in 3.3 V systems, while shutdown and standby modes can reduce consumption when the node is not actively exchanging data. Enable CAN FD only when the connected controller and network configuration support it, and control the STB behavior carefully during sleep and wake transitions.
おすすめ
Motor Drive and Power Inverter Control
The TCAN332GDCNT provides the physical-layer link between a motor-drive controller and a CAN network carrying commands, status, and diagnostic data. The 5 Mbit/s rate allows CAN FD controllers to exchange larger payloads, reducing protocol overhead in multi-axis systems. Place the transceiver near the bus header, provide proper bus termination at the network ends, and use the differential CAN routing pattern recommended by TI to limit radiated emissions.
おすすめ
Automotive Body and Comfort Module
The TCAN332GDCNT supports CAN connections for body-control modules, door controllers, climate systems, and lighting subsystems. Its 8-pin SOT-23-8 package saves PCB area in compact modules, and its 5 Mbit/s capability allows CAN FD traffic where the vehicle network supports it. The -40 °C to 125 °C operating range is useful for compartment-mounted electronics, but automotive qualification and production-test requirements must be confirmed for the exact ordering code.
おすすめ
Elevator, HVAC, and Building Equipment
The TCAN332GDCNT is appropriate for CAN-connected controllers in elevators, HVAC equipment, room controllers, and building automation. Its 3.3 V operation pairs with modern embedded processors, while CAN FD can increase update bandwidth for diagnostics and sensor data. The device also provides shutdown and standby functions for duty-cycled equipment. Verify bus timing at the longest cable length and follow the manufacturer recommendations for termination and PCB spacing.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: TCAN332GDCNT — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | TCAN332DCNT | TCAN337DCNT | TCAN334DCNT | TCAN331DCNT | TCAN330DCNT |
|---|---|---|---|---|---|---|
| Package | SOT-23-8 (DCN) | SOT-23-8 (DCN) | SOT-23-8 (DCN) | SOT-23-8 (DCN) | SOT-23-8 (DCN) | SOT-23-8 (DCN) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Supported Protocols | CAN, CAN FD | CAN, CAN FD | CAN, CAN FD | CAN, CAN FD | CAN, CAN FD | CAN, CAN FD |
| Physical-Layer Compatibility | ISO 11898 high-speed CAN | ISO 11898 high-speed CAN | ISO 11898 high-speed CAN | ISO 11898 high-speed CAN | ISO 11898 high-speed CAN | ISO 11898 high-speed CAN |
主な差別化要因
- Five-megabit-per-second CAN FD performance in a compact package (vs TCAN330DCNT)
- CAN FD support with a 3.3 V supply (vs TCAN332DCNT)
- Compact SOT-23-8 implementation for space-constrained nodes (vs TCAN332DCNT)
設計ノート
Route CANH and CANL as a closely coupled differential pair, keep their routing symmetrical, and avoid long stubs or branching test pads. Position the TCAN332GDCNT close to the connector so common-mode transient energy reaches the transceiver protection elements before entering sensitive logic circuitry. Keep the CAN trace away from switching-power nodes and follow the recommended spacing and return-path arrangement in the TI TCAN332G datasheet.
Do not enable CAN FD communication unless the connected controller and complete bus configuration support the additional timing requirements. Verify the STB, standby, and shutdown behavior before connecting the transceiver to a duty-cycled controller; incorrect mode-control sequencing can leave the bus driver in an unexpected state. Also confirm that the transceiver logic thresholds match the controller's 3.3 V interface rather than assuming compatibility from supply voltage alone.
Use a 120 Ω termination only at the two physical ends of a standard high-speed CAN bus, with one termination on each line. Avoid placing both terminations at a single transceiver when several nodes share the bus. Keep the termination close to the connector, use a common-ground return path with the bus, and maintain the specified bus length and node-spacing limits for the 5 Mbit/s signaling rate.
Place the required supply and bypass capacitors close to the transceiver power pins, with the exact capacitance and placement taken from the TI application circuit. Keep the 3.3 V supply within the 3 V to 3.6 V operating range and account for transient energy absorbed by the bus protection network. Validate the supply during CAN bus fault injection so that protection current does not pull the rail outside the operating specification.
コンプライアンス情報
RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status require confirmation from the current TI product documentation or supplier certificates.