LTC2955ITS8-2#TRPBF vs LTC2955ITS8-2 Pengandingan

Pengandingan Sisi Kiri Sisi Kanan Terperinci LTC2955ITS8-2#TRPBF disebabkan oleh Analog Devices dan LTC2955ITS8-2 disebabkan oleh Analog Devices. Bandingkan spesifikasi utama, parameter elektrik, pakej, status kehidupan, harga, dan keupayaan untuk menentukan komponen terbaik untuk keperluan disenjaya anda.

Analog Devices
LTC2955ITS8-2#TRPBF LTC2955ITS8-2#TRPBF - Pushbutton On/Off Controller | Analog Devices

LTC2955ITS8-2#TRPBF - Pushbutton On/Off Controller | Analog Devices

LTC2955ITS8-2#TRPBF ✓ Aktif

Pengandingan Spesifikasi

Parametr LTC2955ITS8-2#TRPBF LTC2955ITS8-2
Merek Analog Devices Analog Devices
Kategori Supervisors & Reset Supervisors & Reset
Status Lingkungan Hidup Aktif Aktif
Fungsi Pushbutton On/Off Controller with Automatic Turn-On Pushbutton On/Off Controller with Automatic Turn-On
Polarity Variant -2 (Automatic Turn-On, Enable on KILL de-assertion) —
Input Voltage Range (VIN) 1.5 V to 36 V —
Supply Current (Quiescent) 1.2 µA typical —
Pushbutton Input (PB) Debounced, polarity-independent —
Supply Monitor Input (SUP) Yes, with internal threshold and adjustable input —
INT Output Open-drain, active-low interrupt to host —
Enable Output (EN) Active-high, open-drain capable of driving external P-FET —
KILL Input Active-high logic input to forcibly disable system —
Turn-On Debounce / Reset Timer User-configurable via external capacitor —
Gambaran Suhu Operasi -40 °C to +85 °C (Industrial) -40 °C to +85 °C
Kemasan TSOT-23-8 (TS8) TSOT-23-8 (TS8)
Jenis Pemasangan Surface Mount Surface Mount
Aras MSL 1 (Unlimited) 1 (unlimited)
Status RoHS Compliant Compliant (#PBF suffix)
Lead-Free Finish Yes (PBF suffix) —
Packaging Tape & Reel (TRPBF suffix) —
Manufacturer — Analog Devices
Input Voltage Range (VCC) — 1.6 V to 36 V
Typical Quiescent Current — 1.2 µA
Enable Output Polarity — Active-High (-2 suffix variant)
Pushbutton Debounce Time — Programmable via external capacitor
Turn-Off Time — Programmable via external capacitor
INT (Interrupt) Output — Open-drain, signals button press or low supply
KILL (Power Kill) Input — Active-low, allows host to force shutdown
Lead-Free — Yes
Duty Cycle — Continuous
Bilangan Pin — 8
Recommended for New Designs — Yes (per ADI product page)

Laporan Datasheet & Sumber