MAX1396MTB+T vs MAX1393ETB+T Pengandingan
Pengandingan Sisi Kiri Sisi Kanan Terperinci MAX1396MTB+T disebabkan oleh Analog Devices dan MAX1393ETB+T disebabkan oleh Analog Devices. Bandingkan spesifikasi utama, parameter elektrik, pakej, status kehidupan, harga, dan keupayaan untuk menentukan komponen terbaik untuk keperluan disenjaya anda.
Pengandingan Spesifikasi
| Parametr | MAX1396MTB+T | MAX1393ETB+T |
|---|---|---|
| Merek | Analog Devices | Analog Devices |
| Kategori | ADC/DAC | ADC/DAC |
| Status Lingkungan Hidup | Aktif | Aktif |
| Pemecahkatan | 12 bit | 12 bit |
| Sample Rate | 312.5 ksps | — |
| Number of Channels | 1 differential / 2 single-ended | 1 (true-differential) / 2 (single-ended) |
| Architecture | SAR (Successive Approximation) | SAR (Successive Approximation Register) |
| Input Type | True-Differential / Single-Ended (configurable) | True-Differential / Single-Ended (configurable) |
| Tegangan Pemberi Arus | 1.5 V to 3.6 V | — |
| Supply Current (active) | 690 uA (typ at 312.5 ksps) | — |
| Supply Current (shutdown) | <1 uA (automatic power-down) | [DATA_NEEDED: typical shutdown supply current] |
| Internal Oscillator | 3.84 MHz | — |
| Antaramuka | SPI / QSPI / MICROWIRE-compatible serial | — |
| Reference | Internal 2.5 V or external | — |
| SINAD | [DATA_NEEDED: SINAD in dB] | — |
| INL (max) | [DATA_NEEDED: INL in LSB] | — |
| Suhu Operasi | -55C to +125C (M-grade) | [DATA_NEEDED: operating temperature range] |
| Kemasan | TDFN-10 / HVSON-10 (3x3 mm) | 10-TDFN (3 mm x 3 mm) exposed pad |
| Jenis Pemasangan | Surface Mount | Surface Mount |
| Aras MSL | 1 | — |
| Status RoHS | Compliant | — |
| kadar sampling | — | 312.5 ksps |
| Supply Voltage (VDD) | — | 1.5 V to 3.6 V |
| Supply Current (operating) | — | [DATA_NEEDED: typical operating supply current] |
| Serial Interface | — | SPI / QSPI / MICROWIRE compatible, 3-wire |
| Internal Reference | — | 2.5 V (external reference supported) |
| Automatic Shutdown | — | Yes (auto power-down between conversions) |
| Wake-Up Time | — | [DATA_NEEDED: wake-up time from shutdown] |