MPX4105A vs MPX4200A Pengandingan
Pengandingan Sisi Kiri Sisi Kanan Terperinci MPX4105A disebabkan oleh NXP Semiconductors dan MPX4200A disebabkan oleh NXP Semiconductors. Bandingkan spesifikasi utama, parameter elektrik, pakej, status kehidupan, harga, dan keupayaan untuk menentukan komponen terbaik untuk keperluan disenjaya anda.
NXP Semiconductors
MPX4105A - 15-105kPa Absolute Pressure Sensor | NXP | MAP Sensor
MPX4105A ✓ AktifPengandingan Spesifikasi
| Parametr | MPX4105A | MPX4200A |
|---|---|---|
| Merek | NXP Semiconductors | NXP Semiconductors |
| Kategori | Pressure Sensors | Pressure Sensors |
| Status Lingkungan Hidup | Aktif | Aktif |
| Pressure Type | Absolute | Absolute (Manifold Absolute Pressure) |
| Operating Pressure Range | 15 kPa to 105 kPa (2.18 PSI to 15.23 PSI) | 20 kPa to 200 kPa (2.9 PSI to 29.01 PSI) |
| Maximum Overpressure | [DATA_NEEDED: maximum overpressure rating] | — |
| Gambaran Tegangan Output | 0.3 V to 4.9 V | 0.3 V to 4.9 V |
| Supply Voltage (VCC) | 4.85 V to 5.35 V (5 V typical) | 5.1 V nominal (4.85 V to 5.35 V operating) |
| Jenis Output | Analog voltage, ratiometric | Analog voltage (ratiometric) |
| Accuracy | 1.5% (0C to 85C, typical) | — |
| Suhu Operasi | -40C to +125C | -40 °C to +125 °C |
| Kemasan | 6-SIP Module (through-hole) | — |
| Port Size | Female, 3.4544 mm (0.136 in) barbed | — |
| Technology | Piezoresistive silicon, on-chip signal conditioned | — |
| Jenis Pemasangan | Through Hole | Through Hole |
| Signal Conditioning | On-chip, temperature compensated, laser trimmed | On-chip, temperature compensated, calibrated |
| Status RoHS | Compliant | Compliant |
| Applications | Manifold Absolute Pressure (MAP), engine control, barometric, HVAC | — |
| Full-Scale Output (200 kPa) | — | 4.65 V typical at VCC = 5.1 V |
| Arus Pemberi Arus | — | 10 mA typical |
| Pressure Error (0 °C to 85 °C) | — | 1.5 % maximum (full-scale) |
| Storage Temperature | — | -40 °C to +125 °C |
| Kemasan / Case | — | 6-SIP Module (through-hole) |
| Port Type | — | Integrated axial pressure port |