Pengandingan Sisi Kiri Sisi Kanan Terperinci V375A36T400BL disebabkan oleh Vicor dan V375A36C400BL disebabkan oleh Vicor. Bandingkan spesifikasi utama, parameter elektrik, pakej, status kehidupan, harga, dan keupayaan untuk menentukan komponen terbaik untuk keperluan disenjaya anda.
Pengandingan Spesifikasi
| Parametr | V375A36T400BL | V375A36C400BL |
|---|---|---|
| Merek | Vicor | Vicor |
| Kategori | DC-DC Converters | DC-DC Converters |
| Status Lingkungan Hidup | Aktif | Aktif |
| Manufacturer | Vicor Corporation | Vicor Corporation |
| Series | Maxi (375V Input Family) | Maxi |
| Module Type | Isolated DC-DC Converter Module | — |
| Tetstruktur | High-frequency switching (high-speed MOSFETs) | ZCS (Zero-Current-Switching) fixed frequency |
| Bilangan Output | 1 | 1 |
| Output Voltage (Nominal) | 36 V | — |
| Arus Output (Max) | 11.1 A | — |
| Output Power (Max) | 400 W | — |
| Input Voltage (Min) | 250 V DC | — |
| Input Voltage (Max) | 425 V DC | — |
| Input Voltage (Nominal) | 375 V DC | — |
| Input Surge Withstand | 500 V for 100 ms | 500 V for 100 ms |
| Output Voltage Range (Trim/Programmable) | up to 110% of nominal | — |
| Line/Load Regulation | ±0.25% no-load to full-load (per DigiChip summary) | — |
| Isolation | Isulated output | — |
| Jenis Pemasangan | Through Hole | Through Hole |
| Package / Form Factor | Vicor Maxi brick (through-hole) | — |
| Efficiency (Typical) | Up to ~90-95% (varies with operating point) | — |
| Suhu Operasi | [DATA_NEEDED: full operating temperature range] | — |
| Status RoHS | [DATA_NEEDED: RoHS compliance status] | [DATA_NEEDED: RoHS status] |
| Lead-Free | [DATA_NEEDED: lead-free status] | — |
| Type | — | Isolated Module DC-DC Converter |
| Gambaran Tegangan Masukan | — | 250 V to 425 V DC |
| Nominal Input Voltage | — | 375 V |
| Tegangan Output | — | 36 V |
| Output Current | — | 11.11 A |
| Output Power | — | 400 W |
| Output Voltage Range (Programmable) | — | 3.6 V to 39.6 V (10% to 110%) |
| Kecocokan | — | Up to 89% |
| Line Regulation | — | [DATA_NEEDED: line regulation %] |
| Load Regulation | — | ±0.25% (no load to full load) |
| Isolation Voltage | — | [DATA_NEEDED: isolation voltage V] |
| Maximum Operating Temperature | — | 100 °C (full load) |
| Kemasan / Case | — | Full Brick (Vicor Maxi through-hole module) |
| Protection Features | — | Over-current, over-voltage, over-temperature |
| Lead Free | — | [DATA_NEEDED: lead free status] |
| Aras MSL | — | Not applicable (through-hole module) |