AD7712AN - 24-Bit Sigma-Delta ADC | Analog Devices | Precision Sensing
MPN: AD7712AN ✓ AktifAD7712AN Ringkasan
A sigma-delta ADC is a category of data-converter IC that oversamples its input and uses digital filtering and noise shaping to produce high-resolution conversion results. The AD7712 integrates this conversion architecture with programmable gain, analog input conditioning, a differential low-level channel, a high-level channel, calibration functions, and a serial digital interface. In the broader semiconductor hierarchy, it belongs to the ADC and DAC category within integrated circuits and to the class of signal-conditioning data converters.
The AD7712 provides 24-bit resolution with no missing codes and a stated nonlinearity of 0.0015%. Both analog input channels support programmable gains from 1 to 128. The low-level channel accepts differential input, while the high-level channel accepts signals spanning up to 4 VREF. An integrated programmable low-pass digital filter helps reject high-frequency noise, while charge-balancing ADC operation supports accurate conversion of slowly varying or multiplexed analog signals.
System calibration is an important operating consideration because two voltages applied sequentially to the analog input define the input span. The input-span specification determines the minimum and maximum voltages from zero to full scale that the converter can accept while retaining accurate gain calibration. Designers should therefore choose the reference voltage, gain, analog range, and calibration sequence as one coordinated measurement system rather than configuring each parameter independently.
Typical applications include bridge-based pressure and force measurement, industrial temperature instrumentation, process-control sensor interfaces, multichannel measurement systems, and low-frequency data acquisition. The two-channel architecture permits a system to combine a sensitive differential measurement with a wider-range high-level input, while programmable gain accommodates transducers with different output sensitivities. Serial data transfer also makes the converter suitable for instrumentation designs where pin count and board space are constrained.
For a robust implementation, place the analog input, reference, and filter components close to the converter, maintain the required bypass capacitance, and keep switching regulators and digital timing signals away from sensitive analog traces. Allow the serial interface to remain inactive until the converter and analog front end have stabilized. The device is specified as CMOS technology and is listed by Analog Devices as a production part.
This page organizes the AD7712AN specifications, application guidance, package information, and verified cross-reference options for engineers evaluating the converter. It also distinguishes exact drop-in package candidates from redesign-level substitutes so that PCB compatibility, measurement accuracy, and system calibration requirements can be assessed before sourcing.
Pilihan pengganti yang segera untuk AD7712AN — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.
Varietas dalam siri ini
Model serupa yang kompatibel dengan pengganti yang segera AD7712AN (sama faktor bentuk dan kaki) — berbeza dalam Calibration Method.
AD7712ANZ
✅ Masuk Drop-In📋 Alternatif rujukan (tidak dalam katalog)
AD7712AQ
✅ Masuk Drop-InHubungi untuk harga
Lihat Datasheet →AD7712AN Penilaian maksimum & Ciri-ciri Elektrik
| Pemecahkatan | 24 bits |
| ADC Architecture | Sigma-delta |
| Analog Input Channels | 2 channels |
| Low-Level Input Configuration | Differential |
| High-Level Input Reference | 4 VREF |
| Programmable Gain Range | 1 to 128 |
| Nonlinearity | 0.0015% |
| Converter Technology | CMOS charge-balancing ADC |
| Digital Filter | Programmable low-pass filter |
| Calibration Method | System calibration using two sequential input voltages |
| Kemasan | 24-pin PDIP |
| Jenis Pemasangan | Through-hole |
| Kiraan Pin | 24 pins |
| Data Interface | Serial digital interface |
| Production Status | Production |
Panduan Konfigurasi Pin AD7712AN 24-pin pdip
Konfigurasi pin untuk AD7712AN (24-pin pdip pakai). Komponen analog ini mempunyai pin masukan, keluaran, dan kuasa. Rujuk dokumen pengeluar untuk konfigurasi pengecualian, pemulihan, dan pin aktifkan. Ideal untuk pengawasan isyarat dan litar pengukur.
Tiada data garisan pin yang diperoleh untuk AD7712AN.
Rujuk kepada lembaran data untuk konfigurasi pin penuh.
Aplikasi Biasa
AD7712AN patut untuk 6 aplikasis: Bridge-Based Pressure Measurement, Industrial Temperature Instrumentation, Process-Control Sensor Interface, Multichannel Low-Frequency Data Acquisition, Precision Force and Weight Measurement, Laboratory Measurement Equipment.
Bridge-Based Pressure Measurement
The AD7712AN fits bridge-based pressure and load-cell measurement because its differential low-level input supports small sensor signals while programmable gain from 1 to 128 accommodates different bridge sensitivities. The 24-bit converter and 0.0015% nonlinearity are appropriate for slow industrial measurements that require resolution and calibration rather than high conversion speed. In the signal chain, the bridge output is applied to the differential input, the analog front end and programmable low-pass filter reject high-frequency noise, and the result is transferred through the serial interface. System calibration should use two accurately known voltages spanning the operating input range.
Disebarkan
Industrial Temperature Instrumentation
The AD7712AN is suitable for industrial temperature instrumentation when a thermocouple, RTD, or resistance-based sensor produces a low-level differential signal. Its programmable gain can be selected to match the sensor and excitation arrangement, while the differential channel helps reject common-mode voltage present in long industrial wiring. The 24-bit resolution preserves fine changes in the measured temperature, and the programmable low-pass filter attenuates noise outside the useful thermal-signal bandwidth. For accurate results, the reference and sensor circuitry require careful layout, and the two-point system calibration should cover the full input span used in operation.
Disebarkan
Process-Control Sensor Interface
The AD7712AN provides a compact interface for process-control sensors that emit slow analog voltages requiring high resolution. A high-level input referenced to 4 VREF can accommodate broader sensor ranges, while the differential low-level channel remains available for a more sensitive auxiliary measurement. Programmable gain from 1 to 128 allows the same converter to normalize inputs with different sensitivities, and the programmable low-pass filter supports filtering according to the process bandwidth. The serial digital output can feed a controller while the two-channel architecture reduces the number of separate converters required when multiple slow variables must be monitored.
Disebarkan
Multichannel Low-Frequency Data Acquisition
The AD7712AN is useful in low-frequency data-acquisition systems where two analog variables must be digitized with consistent resolution. One channel can handle a sensitive differential sensor while the second handles a higher-level process signal referenced to 4 VREF. The 24-bit conversion resolution provides detailed numerical results for slowly changing quantities such as pressure, level, temperature, or flow, and the programmable low-pass filter can reject unwanted out-of-band noise. Because conversion and filtering are designed for measurement rather than high-speed waveform capture, system timing should respect the selected filter and conversion-rate settings while the serial interface transfers each result to the controller.
Disebarkan
Precision Force and Weight Measurement
The AD7712AN is well suited to force, weight, and displacement systems using strain-gauge bridges because the differential low-level input supports bridge imbalance signals and the programmable gain accommodates differing mechanical sensitivities. Its 24-bit resolution and 0.0015% nonlinearity support accurate static-force measurement, while the low-pass filter helps suppress structural and electrical noise. The converter can be placed near the bridge and analog front end to minimize sensitive-signal routing, but its 24-pin PDIP footprint requires adequate board space. A stable excitation, low-noise reference, careful grounding, and two known calibration inputs remain central to repeatable measurement performance.
Disebarkan
Laboratory Measurement Equipment
The AD7712AN can serve as the measurement converter in laboratory instruments that monitor low-frequency sensor outputs with high resolution. The two input channels allow a sensitive differential channel and a wider-range high-level channel to coexist in one 24-pin PDIP device, while programmable gain simplifies front-end scaling across different probes and fixtures. The serial interface suits a microcontroller or controller that manages calibration, range selection, and data acquisition. For highest measurement integrity, separate analog and digital return paths, use a quiet reference source, and keep the serial clock and conversion-control traces away from the differential input and reference pins.
Disebarkan
Ringkasan Produk Disebarkan
Data referensi kejuruteraan untuk AD7712AN — perbandingan, panduan rancangan, dan maklumat kesediaan
Panduan Pilihan
Perbandingan dengan Gantian
| Parametr | Produk Ini | AD7712ANZ | AD7712AQ |
|---|---|---|---|
| Package | PDIP-24 | PDIP-24 | PDIP-24 |
| Brand | Analog Devices | Analog Devices | Analog Devices |
Penyeberangsung Jelas
- Two-channel signal conditioning in one converter (vsAD7712ANZ)
- Programmable gain for low-level transducers (vsAD7712AQ)
- Differential and high-level measurement in one device (vsAD7712ANZ)
Catatan Desain
Route the differential input as a compact, symmetric pair and connect its return directly to the converter's analog ground path. Keep the reference and analog input nodes away from serial-interface clocks, relay transitions, and switching-converter inductors. Because the AD7712 is intended for low-level measurement, small ground-potential differences in the analog section can affect the result even when the converter resolution is high.
Configure the input span and system-calibration voltages to cover the full range used by the application. The Analog Devices AD7712 datasheet, Revision F, explains that two sequential voltages define the input span, so calibration performed over a smaller span may not compensate gain and offset across the operating range. Recheck calibration whenever the gain, reference, sensor excitation, or input range changes.
Use the programmable low-pass filter according to the required measurement bandwidth and settling time rather than selecting the highest possible conversion rate indiscriminately. A slower filter can improve rejection of out-of-band noise, while a faster setting shortens response time. Confirm that both the analog input network and digital system can settle before the conversion result is used.
Place bypass and reference components close to their associated pins, follow the pin-description table in the manufacturer datasheet, and provide an unobstructed return path for analog current. The 24-pin PDIP footprint is convenient for prototyping and through-hole assembly but occupies more PCB area than an equivalent surface-mount converter; evaluate footprint migration separately rather than assuming the pinout remains unchanged.
Maklumat Kesediaan
The AD7712 family is identified as a production CMOS product. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not identified, so those attributes remain unknown.