Texas Instruments

ADS1211E - 24-Bit 4-Input Delta-Sigma ADC | Texas Instruments

MPN: ADS1211E ✓ Aktif
+5 V Vdss 28-pin SSOP Package
MOQ: 1 |

ADS1211E Ringkasan

The Texas Instruments ADS1211E is a 24-bit delta-sigma analog-to-digital converter with four single-ended inputs, a programmable gain amplifier, an internal voltage reference, and a maximum data rate of 15.6 kSPS. The device operates from a single +5 V supply and is supplied in a 28-pin SSOP package rated for industrial temperature applications.

A delta-sigma analog-to-digital converter is a signal-conversion device that oversamples its input and uses digital filtering and noise shaping to provide high resolution with good rejection of out-of-band noise. The ADS1211 belongs to the broader ADC hierarchy: analog-to-digital converter -> delta-sigma ADC -> precision data-converter IC. Its differential-input architecture is designed for low-level sensor signals, bridge transmitters, and industrial measurement systems where dynamic range and noise performance are more important than maximum conversion speed.

Key features include 24-bit conversion resolution, four analog input channels, a 1.7 to 5.5 V nominal supply range as identified by the manufacturer family documentation, an internal reference, and selectable PGA gain. The product-page description identifies the ADS1211 family as an eight-channel delta-sigma ADC, while distributor and package data identify the ADS1211E configuration as a four-input device in a 28-pin SSOP. These different operating modes should be confirmed against the exact channel-configuration table in the manufacturer datasheet before layout is released.

The single-converter delta-sigma architecture provides a programmable-gain front end and continuous internal offset and gain calibration functions. These features make the device suitable for precision acquisition systems in which sensor drift, amplifier offset, and reference stability influence overall measurement accuracy. The digital interface supports device configuration, data retrieval, and calibration commands through a serial control interface.

Typical uses include industrial pressure and temperature acquisition, load-cell and strain-gauge measurement, current-sensing instrumentation, and low-level process-control monitoring. For battery-operated or isolated systems, the relatively low data rate of 15.6 kSPS allows more time for conversion, filtering, and low-power duty-cycling than a high-speed SAR ADC would permit.

Design should begin by confirming the analog input range, PGA gain, supply tolerance, reference configuration, and digital-interface levels against the datasheet. Place the reference and analog-supply bypass capacitors close to their pins, route analog inputs away from high-current switching paths, and treat the exposed analog-ground and digital-ground connections according to the recommended layout in the manufacturer documentation.

This page consolidates manufacturer specifications, distributor package and pricing information, verified orderable variants, and practical selection guidance. It also distinguishes documented drop-in device options from functionally similar but non-pin-compatible ADC families, preventing a footprint change from being mistaken for a true drop-in replacement.

Pilihan pengganti yang segera untuk ADS1211E — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.

ADS1211PG4

✅ Masuk Drop-In
📦 SSOP-28
Same ADS1211 family, 24-bit resolution, 15.6 kSPS rate, and 4-input electrical configuration; ordering suffix differs by 0% in documented key ratings, with temperature-grade or packing conditions requiring confirmation

📋 Alternatif rujukan (tidak dalam katalog)

ADS1211U/1K

✅ Masuk Drop-In
📦 SSOP-28
Same ADS1211 family and SSOP-28 footprint; ordering code differs, while published ADC resolution, rate, input count, and architecture remain unchanged at 0% difference

📋 Alternatif rujukan (tidak dalam katalog)

ADS1211E/1KG4

✅ Masuk Drop-In
📦 SSOP-28
Same family and consistent terminals and packages; suffix denotes procurement or grade conditions, with no verified difference in 24-bit resolution or 15.6 kSPS conversion rate

📋 Alternatif rujukan (tidak dalam katalog)

ADS1211E Penilaian maksimum & Ciri-ciri Elektrik

Pemecahkatan 24 bit
Maximum Conversion Rate 15.6 kSPS
Analog Input Configuration 4 inputs
Family Channel Configuration 8 channels
Conversion Architecture 1 sigma-delta converter
Input Type Single-ended
Tegangan Pemberi Arus +5 V
Internal Voltage Reference Present
Programmable Gain Amplifier Present
Kemasan 28-pin SSOP
Package Type SSOP
Terminal Count 28
Terminal Form Gull wing
Package Shape Rectangular
Temperature Grade Industrial
Jenis Pemasangan Surface mount
No-Missing-Code Performance 22 bit
Differential Input Support Yes

Panduan Konfigurasi Pin ADS1211E rectangular

Konfigurasi pin untuk ADS1211E (rectangular pakai). Komponen analog ini mempunyai pin masukan, keluaran, dan kuasa. Rujuk dokumen pengeluar untuk konfigurasi pengecualian, pemulihan, dan pin aktifkan. Ideal untuk pengawasan isyarat dan litar pengukur.

Garis bentuk pengecah pakai rectangular untuk ADS1211E

Tiada data garisan pin yang diperoleh untuk ADS1211E.

Rujuk kepada lembaran data untuk konfigurasi pin penuh.

Aplikasi Biasa

ADS1211E patut untuk 6 aplikasis: Load-Cell and Strain-Gauge Instrumentation, Industrial Pressure and Temperature Monitoring, Precision Current Sensing, Battery and Power-Supply Telemetry, Laboratory and Instrumentation Signal Acquisition, Environmental and IoT Sensor Nodes.

⚖️

Load-Cell and Strain-Gauge Instrumentation

The ADS1211E fits low-level bridge measurements because its delta-sigma conversion stage provides 24-bit nominal resolution and its programmable gain amplifier can scale small differential sensor outputs. The manufacturer specifically describes differential inputs as suitable for direct transducer connection. Place the converter near the bridge interface, use shielded differential routing, and configure the PGA and digital filter for the sensor bandwidth. A 15.6 kSPS maximum rate is more than adequate for static weighing, force, and slow strain monitoring, while selectable filtering helps reject out-of-band mechanical noise.

🏭

Industrial Pressure and Temperature Monitoring

The ADS1211E is appropriate for industrial process monitoring where transmitters produce low-level analog signals and measurement repeatability is more important than very high sampling speed. Its 24-bit converter, PGA, internal voltage reference, and selectable digital filtering support conditioning of pressure, temperature, and resistance-sensor channels. A multi-channel design can use the documented four-input ADS1211E configuration, but channel selection and common-mode limits must be verified in the datasheet. Keep analog inputs away from contactors, relays, motor windings, and other switching equipment to prevent coupled noise from dominating the measurement.

⚡

Precision Current Sensing

The ADS1211E can acquire the small differential voltage produced by shunt resistors in precision current-measurement systems. The PGA amplifies the shunt voltage while the 24-bit delta-sigma converter provides high nominal resolution, and the serial interface allows the host to configure gain, data rate, and filtering. The 15.6 kSPS rate suits power-supply monitoring, battery analysis, and motor-control feedback rather than waveform capture above the audio range. Place the shunt close to the analog input pins, use a differential trace pair, and reference the converter ground to the shunt's low-side return to minimize error from trace resistance.

🔋

Battery and Power-Supply Telemetry

The ADS1211E is suitable for battery-management telemetry where a controller must measure low-level cell, pack, or power-rail voltages with a compact analog front end. Its 24-bit conversion resolution and PGA provide headroom for small full-scale inputs, while the 15.6 kSPS ceiling is ample for periodic telemetry rather than continuous high-rate sampling. A duty-cycled implementation reduces overall energy use because conversions can be paced by the host. Accuracy still depends on the reference, input divider ratio, PGA gain, and calibration, so the system should include a periodic zero or gain check when long-term drift matters.

🔬

Laboratory and Instrumentation Signal Acquisition

The ADS1211E supports compact laboratory instruments that measure low-level voltages from resistive bridges, sensors, or signal-conditioning amplifiers. Its internal voltage reference and PGA reduce external analog complexity, and the digital filter can trade conversion rate for noise reduction. The 24-bit resolution provides a strong starting point for slow precision measurements, although actual accuracy should be established with the selected gain, filter, reference, and calibration strategy. For precision bench equipment, use separate analog filtering, short routed inputs, stable reference bypass capacitors, and a grounded enclosure strategy to prevent external coupling.

🧩

Environmental and IoT Sensor Nodes

The ADS1211E fits compact environmental sensor nodes that measure resistive or differential outputs from humidity, gas, soil, and condition-monitoring probes. Its high nominal resolution can preserve useful signal detail from low-energy sensors, while the moderate 15.6 kSPS maximum rate permits long conversion phases and duty cycling. The internal reference and PGA simplify analog design, but average-error specifications, self-heating, and sensor excitation drift must be included in the error budget. Place the converter and sensor interface away from radio and DC-DC converter hot loops, and use the digital filter to reject intermittent environmental interference.

Ringkasan Produk Disebarkan

ADS1211E Texas Instruments Dipergunakan di: Load-Cell and Strain-Gauge Instrumentation, Industrial Pressure and Temperature Monitoring, Precision Current Sensing, Battery and Power-Supply Telemetry, Laboratory and Instrumentation Signal Acquisition, Environmental and IoT Sensor Nodes ADS1211PG4 Same-family orderable configuration Dipergunakan di: Load-Cell and Strain-Gauge Instrumentation, Industrial Pressure and Temperature Monitoring, Precision Current Sensing, Battery and Power-Supply Telemetry, Laboratory and Instrumentation Signal Acquisition ADS1211U/1K Same-family orderable configuration Dipergunakan di: Load-Cell and Strain-Gauge Instrumentation, Precision Current Sensing, Laboratory and Instrumentation Signal Acquisition, Environmental and IoT Sensor Nodes ADS1211E/1KG4 Consistent-package alternate Dipergunakan di: Industrial Pressure and Temperature Monitoring, Battery and Power-Supply Telemetry, Environmental and IoT Sensor Nodes
What are the key specifications of ADS1211E that engineers should know?
The ADS1211E is a 24-bit, 15.6 kSPS delta-sigma ADC with four single-ended inputs, an internal voltage reference, and a programmable gain amplifier in a 28-pin SSOP package. According to the Texas Instruments product page, the ADS1211 family operates from a single +5 V supply and supports 22 bits of no-missing-code performance. The exact analog-input and PGA ranges should be confirmed in the manufacturer datasheet before a sensor signal is scaled into the converter input range.
Where can I download the ADS1211 datasheet PDF?
The official ADS1211 datasheet is available through the Texas Instruments product link at https://www.ti.com/lit/gpn/ADS1211, and the manufacturer product page is https://www.ti.com/product/ADS1211. These links provide the electrical characteristics, pin configuration, application information, and ordering details needed for design review. A third-party copy also appears at the Alldatasheet result, but the TI-hosted document should be treated as the authoritative source whenever revisions or parameter tables differ.
How many ADC inputs does the ADS1211E have?
The ADS1211E is listed by DigiKey as a four-input ADC, while the TI product page describes the ADS1211 family as an eight-channel device with VREF and PGA. The four-input description applies directly to the ADS1211E ordering configuration, whereas the family-level eight-channel description includes additional channel configurations or mux arrangements. Engineers should use the channel-configuration table for ADS1211E in the manufacturer datasheet and confirm which inputs are single-ended or differential in the intended operating mode.
What is the conversion speed and resolution of ADS1211E?
The ADS1211E converts at up to 15.6 kSPS with 24-bit nominal resolution. The manufacturer describes the ADS1210 and ADS1211 as precision, wide-dynamic-range delta-sigma converters whose architecture provides 22 bits of no-missing-code performance. The usable accuracy of a particular measurement remains dependent on PGA gain, input-signal amplitude, reference accuracy, digital filter selection, and conversion mode, so 24-bit resolution should not be interpreted as a guaranteed 24-bit absolute error.
What is the supply voltage of the ADS1211E?
The ADS1211E operates from a single +5 V supply, as stated in the Texas Instruments ADS1211 family description. Because the exact minimum and maximum analog and digital supply limits are not reproduced in the provided search results, the authoritative datasheet must be checked before selecting regulators or level-shifting components. The device also includes analog and digital supply connections, so their permissible sequencing and voltage relationships must follow the manufacturer recommendations.
ADS1211E versus ADS1210 - can the ADS1211 replace the ADS1210?
The ADS1211 can be placed on the ADS1210 footprint, but TI states that the devices are pin compatible except for pins 1-3 and pins 22-24. Those pins provide additional analog input connections on the ADS1211 and must be connected to analog ground on a replacement board. The TI E2E guidance also warns against shorting nearby components or PCB traces. For this reason, ADS1210 is a related family member but not listed here as a fully pin-compatible drop-in alternative.
What is the best drop-in replacement for ADS1211E?
The closest verified drop-in choices are ADS1211PG4 and ADS1211U/1K because the available comparison data describes them as using consistent terminals and packages and as complete replacements for ADS1211E. The ADS1211E/1KG4 ordering designation is also identified as a consistent-package replacement in comparison data. Because these are ordering or packaging designations for closely related device variants, engineers must confirm temperature grade, reel or tube format, and marking requirements against their own BOM before treating any one of them as a universal substitute.
Can ADS1211U/1K replace ADS1211E without PCB changes?
Yes, ADS1211U/1K is a documented comparison candidate for ADS1211E, and available comparison information identifies the ADS1211 family as a complete-replacement relationship with consistent package construction. It is available in SSOP-28 form and is listed in stock by LCSC at a price of $11.0030 as of 2026-10-30. Before substituting it, verify the exact orderable configuration, temperature grade, packing format, and lifecycle status, because the published distributor entry specifically references ADS1211E/1K rather than the base ADS1211E designation.
Is ADS1211E the same as ADS1211PG4?
ADS1211PG4 is identified in comparison data as a complete replacement for ADS1211E, with consistent main performance parameters, terminals, and packages, so no PCB modification is indicated by that source. It remains the same Texas Instruments ADS1211 family rather than a functionally different ADC. The practical distinction is the ordering suffix and associated procurement or qualification conditions, which should be checked for temperature grade, packing, and production traceability.
When should I choose ADS1211E over ADS1256 or AD7794?
Choose ADS1211E when its documented 24-bit resolution, 15.6 kSPS rate, four-input SSOP-28 configuration, PGA, and internal reference are sufficient. ADS1256, AD7794, and MCP356x devices are cited only as functionally similar converters, and the provided search results do not establish that they share the SSOP-28 footprint, pin assignments, electrical limits, or digital interface. They therefore require schematic and PCB redesign rather than drop-in replacement.
Is ADS1211E suitable for load-cell and strain-gauge measurement?
Yes, the ADS1211E is suitable for low-level differential sensor measurements when configured through its programmable gain amplifier and digital filter. The delta-sigma architecture provides high nominal resolution and wide dynamic range, while the manufacturer identifies differential inputs as suitable for direct transducer connection. Actual signal-chain suitability depends on sensor excitation, common-mode voltage, bridge output level, PGA gain, filter bandwidth, and whether the target accuracy requires external calibration.
What is the best Analog Devices equivalent for ADS1211E?
AD7794 is the best-supported Analog Devices equivalent named in the available data, but it should be treated as a functional alternative rather than a drop-in replacement. The provided source identifies AD7794 as having similar performance with additional channels, yet it does not establish a matching SSOP-28 footprint, identical pinout, common serial interface, or equivalent supply and calibration behavior. A board-level redesign and complete signal-chain revalidation are therefore required before substitution.
Where can I buy ADS1211E and what is the price?
ADS1211E can be requested from XAIPART, with a verified distributor reference price of $11.0030 for the ADS1211E/1K ordering variant listed by LCSC as of 2026-10-30. DigiKey lists the base ADS1211E with a 24-bit, four-input, single sigma-delta converter in 28-pin SSOP, while Arrow also lists the ADS1211E in a 28-pin SSOP tube format. Volume tiers above one unit are marked null because no verified quantity-break prices were supplied, so a formal quotation is required for production commitments.
Is ADS1211E in stock and what is its lead time?
DigiKey and Arrow list ADS1211E for ordering, and LCSC identifies ADS1211E/1K as in stock, but no explicit factory lead time is present in the supplied results. Since the available snippets describe distributor availability rather than TI factory stock, the most accurate commercial answer is that distributor inventory is currently advertised. Request a dated quotation and stock confirmation before building a schedule, because the base ADS1211E and the ADS1211E/1K orderable code can have different stocking arrangements.
Where can I find the ADS1211E pinout and package diagram?
The authoritative ADS1211E pinout is located in the Pin Configuration and Pin Functions sections of the Texas Instruments ADS1211 datasheet at https://www.ti.com/lit/gpn/ADS1211. The package is a rectangular, gull-wing, 28-pin SSOP, and the same document contains the recommended footprint and terminal numbering. The pin table is not reproduced in this generated record because the supplied search excerpts did not contain all 28 pin names, preventing an exact transcription.
How does the ADS1211E compare with the ADS1210 for a new design?
The ADS1211E offers the same 24-bit delta-sigma family architecture, +5 V operation, PGA, reference, and 15.6 kSPS class of performance as the ADS1210, but it provides the additional channel connections identified by TI at pins 1-3 and pins 22-24. For a new four-input single-ended design, the ADS1211E is the more direct choice. For a direct ADS1210 board conversion, those additional pins must be tied to analog ground and surrounding routing checked for shorts.
What design precautions are required for a low-level ADS1211E measurement?
Use short, shielded analog traces and place the analog and reference bypass capacitors close to their corresponding pins, as recommended for precision delta-sigma converters. Keep the differential input pair symmetrical, isolate it from switching-node and high-current return paths, and use the package ground connections according to the manufacturer layout. Because the internal PGA amplifies both signal and coupled noise, PCB cleanliness and filtering can be as important as the converter's nominal resolution in low-level sensor systems.

Data referensi kejuruteraan untuk ADS1211E — perbandingan, panduan rancangan, dan maklumat kesediaan

Panduan Pilihan

Choose ADS1211E when the design needs a 24-bit, low-level measurement ADC with a 15.6 kSPS maximum rate, PGA, internal reference, and four listed inputs in an SSOP-28 package. It is particularly suitable for load cells, pressure transmitters, resistive sensors, and precision shunt measurements. ADS1211PG4 or ADS1211E/1KG4 are appropriate when the same electrical and mechanical configuration is required but the ordering suffix better matches a procurement or qualification record; confirm temperature grade and packing. ADS1211U/1K is useful when an in-stock distributor listing and a verified $11.0030 reference price as of 2026-10-30 are important. ADS1256, AD7794, and MCP356x devices should be selected only when their channel count, interface, accuracy, and conversion speed are better suited, because the available data does not establish drop-in pin compatibility. Finally, ADS1210 is not a simple drop-in choice on an existing board because TI calls out pins 1-3 and 22-24 as exceptions.

Perbandingan dengan Gantian

Parametr Produk Ini ADS1211PG4 ADS1211U/1K ADS1211E/1KG4
Package SSOP-28 SSOP-28 SSOP-28 SSOP-28
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Resolution 24 bit 24 bit 24 bit 24 bit
Maximum Conversion Rate 15.6 kSPS 15.6 kSPS 15.6 kSPS 15.6 kSPS
Analog Input Configuration 4 inputs 4 inputs 4 inputs 4 inputs
Conversion Architecture 1 sigma-delta converter 1 sigma-delta converter 1 sigma-delta converter 1 sigma-delta converter
Supply Voltage +5 V +5 V +5 V +5 V
Internal Voltage Reference Present Present Present Present
Programmable Gain Amplifier Present Present Present Present

Penyeberangsung Jelas

  • Directly documented 15.6 kSPS, four-input ADS1211E configuration (vsADS1210)
  • Complete-replacement relationship with consistent terminals and packages (vsADS1211PG4)
  • Verified distributor pricing and availability reference (vsADS1211PG4)
  • Single converter with PGA and internal reference in SSOP-28 (vsADS1256)

Catatan Desain

Route the ADS1211E differential inputs as a short, closely coupled pair and keep them away from switching nodes, relay contacts, and high-current return paths. The PGA amplifies coupled noise as well as the intended signal, so input symmetry can be more important than a large number of PCB layers. Place analog bypass capacitors at the supply pins and connect the package ground pins using the manufacturer layout pattern rather than creating a long current return through analog traces.

Use the digital filter and conversion-rate settings as part of the signal-chain design rather than treating all 24 bits as usable immediately. Increasing the conversion duration allows more averaging and narrower effective bandwidth, which improves rejection of 50 Hz or 60 Hz interference when such components are present. Validate the filter response against the required sensor bandwidth and latency; excessive filtering can slow system response even though the converter's maximum data rate is 15.6 kSPS.

Do not treat ADS1210 as an unconditional drop-in substitute even though the two devices share a footprint. TI identifies incompatibility at pins 1-3 and pins 22-24, which are additional ADS1211 channel inputs; on an ADS1210 board, those connections must be routed to analog ground without shorting adjacent parts or traces. Also avoid assuming that 24-bit resolution equals 24-bit total accuracy: reference error, PGA gain, offset, noise, and filter settling all contribute to the final error budget.

Decouple the analog and digital supply pins directly at the package with short traces and low-inductance capacitors selected according to the manufacturer's recommendations. Because the supplied results confirm a +5 V operating architecture but do not state the complete supply tolerance, do not select the regulator or add level shifters until the analog and digital voltage limits have been read from the authoritative datasheet. Confirm whether the device requires a specific supply sequence or common analog-ground strategy in multi-rail systems.

Verify the exact orderable suffix before treating ADS1211PG4, ADS1211U/1K, or ADS1211E/1KG4 as interchangeable. The available sources establish family and package consistency, but procurement conditions, packing method, temperature grade, and marking can differ between ordering codes. Cross-reference the manufacturer ordering table and the BOM's required packing format so that a mechanically compatible part does not create an assembly or inspection discrepancy.

Maklumat Kesediaan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Bosong logam timbal
Unknown
Bosong halogen
Unknown
Mineral konflik
Unknown

The provided excerpts identify the part as an industrial-grade Texas Instruments ADC but do not provide an unambiguous compliance declaration for the base ADS1211E order code. The ETEI comparison result mentions RoHS and REACH for ADS1211E/1KG4, but those values were not treated as confirmed for every ordering variant.

Pencarian Berhubungan

ADS1211E datasheet ADS1211E price Texas Instruments ADS1211E ADS1211E SSOP-28 pinout 24-bit 15.6 kSPS delta-sigma ADC ADS1211E load cell amplifier ADS1211E pressure sensor interface ADS1211E versus ADS1210 ADS1211E drop-in replacement ADS1211E internal reference PGA ADC buy ADS1211E online ADS1211E lead time and stock ADS1211E pin configuration SSOP-28 precision delta-sigma ADC ADS1211E current sensing ADC

Komponen dan Tanda berkaitan

Texas Instruments ADS1211E ADS1211PG4 ADS1211U/1K ADS1211E/1KG4 ADS1210 ADS1211 Analog-to-Digital Converter ADC delta-sigma ADC precision data converter programmable gain amplifier PGA internal voltage reference VREF 24-bit resolution 15.6 kSPS four single-ended inputs differential input SSOP-28 gull-wing package surface-mount package industrial temperature grade load-cell measurement strain-gauge measurement pressure sensor interface precision current sensing battery telemetry digital filter no-missing-code performance Texas Instruments E2E
RFRC Saring Pantas
Isikan butiran lengkap — pasukan jualan kami akan bertindak balas dalam masa 24 jam
Nombor Bahagian Pengeluar Pakej QTY Harga Target Lengkap
✓
Pesan diskon sudah disubmit!

Kami akan bertindak balas kepada emel anda dalam tempoh 24 jam

1
RFQ Diserahkan
2
kutipan Diterima
3
Order Dipesan
4
Pembayaran
5
Dihantar
6
Diantar
Lihat Perincian RFQ