INA327EA/2K5 - Low-Drift Rail-to-Rail INA | Texas Instruments
MPN: INA327EA/2K5 ✓ AktifINA327EA/2K5 Ringkasan
An instrumentation amplifier is a specialized amplifier IC that amplifies the voltage difference between two inputs while rejecting common-mode signals. The INA327 belongs to the instrumentation amplifier hierarchy, where it combines a precision amplifier core with input buffers, resistor-network gain configuration, and rail-to-rail interfaces. Its common-mode rejection of 100 dB helps preserve accuracy when a sensor signal shares the same electrical environment with larger interference voltages.
Key characteristics include 0.08% gain error, a maximum input offset voltage of 20 µV, input bias current of 200 pA, and input voltage noise of 33 nV/√Hz at 1 kHz. The specified temperature drift of 100 nV/°C supports stable measurements across changing ambient conditions. A typical supply current of 2.4 mA also makes the device practical for low-power sensor instrumentation and portable test equipment.
Internally, the INA327 uses a precision CMOS architecture designed for low DC error and low drift. The /2K5 ordering code identifies the 2.5 gain configuration, while the amplifier still supports external resistor-based gain programming as described for the INA327 family. Rail-to-rail inputs are particularly useful when sensing signals near the supply rails, and the shutdown pin allows a system to reduce power consumption when measurements are not required.
Typical applications include bridge and strain-gauge signal conditioning, biomedical instrumentation, industrial pressure measurement, current sensing, and low-level sensor interfaces. In each case, the device's 100 dB common-mode rejection, 20 µV offset specification, and low 33 nV/√Hz input noise help retain accuracy in electrically noisy environments. The small VSSOP-10 package also supports high-density analog boards.
A key design consideration is common-mode range and input bias behavior. Confirm that both input voltages remain within the usable input range for the chosen supply voltage, and keep the gain resistor close to the appropriate INA327 pins to minimize added noise and parasitic resistance. Check output headroom before operating sensors near the supply limits.
This page combines manufacturer specifications, verified ordering information, package details, practical application guidance, and a strict drop-in comparison for engineers evaluating the INA327EA/2K5 in precision analog designs.
Pilihan pengganti yang segera untuk INA327EA/2K5 — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.
INA327EA/2K5G4
✅ Masuk Drop-In📋 Alternatif rujukan (tidak dalam katalog)
INA327EA/2K5 Penilaian maksimum & Ciri-ciri Elektrik
| Device Type | Precision CMOS instrumentation amplifier |
| Number of Amplifiers | 1 circuit |
| Gain Setting | 2.5 |
| Supply Voltage Range | 2.7 V to 5.5 V |
| Gain Error | 0.08% |
| Common-Mode Rejection | 100 dB |
| Maximum Input Offset Voltage | 20 µV |
| Input Bias Current | 200 pA |
| Input Voltage Noise Density | 33 nV/√Hz at 1 kHz |
| Input Offset Voltage Drift | 100 nV/°C |
| Arus Pemberi Arus | 2.4 mA |
| Gain-Bandwidth Product | 1 MHz |
| Input Type | Rail-to-rail |
| Jenis Output | Rail-to-rail |
| Gambaran Suhu Operasi | -40°C to +85°C |
| Kemasan | 10-pin VSSOP (DGS) |
| Jenis Pemasangan | Surface mount |
| Shutdown Function | Yes |
| Overvoltage Protection | Yes |
| Status RoHS | Compliant |
Panduan Konfigurasi Pin INA327EA/2K5 10-pin vssop (dgs)
Konfigurasi pin untuk INA327EA/2K5 (10-pin vssop (dgs) pakai). Komponen analog ini mempunyai pin masukan, keluaran, dan kuasa. Rujuk dokumen pengeluar untuk konfigurasi pengecualian, pemulihan, dan pin aktifkan. Ideal untuk pengawasan isyarat dan litar pengukur.
Tiada data garisan pin yang diperoleh untuk INA327EA/2K5.
Rujuk kepada lembaran data untuk konfigurasi pin penuh.
Aplikasi Biasa
INA327EA/2K5 patut untuk 6 aplikasis: Strain-Gauge Bridge Conditioning, Industrial Pressure Sensor Interface, Medical and Biopotential Signal Conditioning, Precision Shunt Current Sensing, Battery-Powered Sensor Node, Low-Noise Analog Test and Measurement.
Strain-Gauge Bridge Conditioning
The INA327EA/2K5 is well suited to conditioning low-level differential bridge outputs because its 2.5 gain setting, 0.08% gain error, and 100 dB common-mode rejection preserve weak sensor signals in the presence of common-mode voltage. The 20 µV maximum input offset and 100 nV/°C drift specification support stable measurements across industrial temperature changes. Place it near the bridge and use short, matched input traces to minimize added noise and thermocouple error. The rail-to-rail input capability provides flexibility with 3.3 V or 5 V excitation systems, while the shutdown input can reduce activity between measurements.
Disebarkan
Industrial Pressure Sensor Interface
The INA327EA/2K5 fits pressure transmitters that generate a small differential voltage from a resistive sensing element. Its 2.5 gain configuration increases sensor sensitivity without requiring a separate fixed-gain amplifier, while the 100 dB common-mode rejection helps reject interference common to both sensor inputs. With 200 pA input bias current, the device places limited demand on high-impedance sensor networks. Its 2.7 V to 5.5 V operating range supports compact industrial electronics, and the shutdown function can be coordinated with duty-cycled acquisition when continuous sensing is unnecessary.
Disebarkan
Medical and Biopotential Signal Conditioning
The INA327EA/2K5 can condition low-amplitude differential signals in medical measurement front ends when its specified noise and offset performance meet the system requirements. The 33 nV/√Hz input noise at 1 kHz, 200 pA bias current, and 20 µV maximum offset are useful for high-impedance sensor interfaces, while 100 dB common-mode rejection helps preserve the small differential signal. Its rail-to-rail input and output stages support low-voltage acquisition electronics. Designers must still enforce patient-safety isolation outside the IC, validate applicable medical standards, and assess electrode, protection-network, leakage, and system-noise contributions.
Disebarkan
Precision Shunt Current Sensing
The INA327EA/2K5 is appropriate for low-value current-shunt monitoring when a 2.5 amplification factor is sufficient and the measured current remains within the amplifier’s input and output ranges. Its 20 µV offset specification translates into a defined measurement error across the shunt, and the 100 dB common-mode rejection reduces errors when the shunt voltage sits on a larger supply rail. The 2.4 mA typical supply current is suitable for compact power systems. Keep the shunt within the input common-mode range, use Kelvin routing where possible, and verify output headroom at the maximum intended load.
Disebarkan
Battery-Powered Sensor Node
The INA327EA/2K5 supports compact battery-powered sensor nodes because it operates from 2.7 V to 5.5 V and has a typical supply current of 2.4 mA. The shutdown function allows a controller to disable the amplifier between acquisition intervals, which can reduce system energy use when the sensing duty cycle is low. Its precision DC performance helps retain measurement integrity in portable instruments, while the 10-pin VSSOP saves board area. Designers should assess shutdown timing, startup settling, leakage into the sensor path, and regulator efficiency when calculating the complete node power budget.
Disebarkan
Low-Noise Analog Test and Measurement
The INA327EA/2K5 is useful in bench instrumentation and low-level measurement fixtures where a small differential signal must be amplified close to the source. Its 33 nV/√Hz input noise, 100 dB common-mode rejection, and 2.5 gain setting improve the signal presented to a downstream ADC or measurement instrument. The rail-to-rail interface allows operation from a 3.3 V or 5 V analog rail, while shutdown supports power-managed test fixtures. For best results, define the required noise bandwidth, use low-noise gain resistors, keep sensitive traces away from switching nodes, and verify that source impedance does not degrade bias-current error.
Disebarkan
Ringkasan Produk Disebarkan
Data referensi kejuruteraan untuk INA327EA/2K5 — perbandingan, panduan rancangan, dan maklumat kesediaan
Panduan Pilihan
Perbandingan dengan Gantian
| Parametr | Produk Ini | INA327EA/2K5G4 |
|---|---|---|
| Package | 10-VSSOP (DGS) | 10-VSSOP (DGS) |
| Brand | Texas Instruments | Texas Instruments |
| Device Type | Precision CMOS instrumentation amplifier | Precision CMOS instrumentation amplifier |
| Gain Setting | 2.5 | 2.5 |
| Shutdown Function | Yes | Yes |
Penyeberangsung Jelas
- Matches the verified same-family legacy suffix at the same nominal gain (vsINA327EA/2K5G4)
- Combines precision gain error with low input offset (vsINA327EA/2K5G4)
- Supports power-managed measurement systems (vsINA327EA/2K5G4)
- Provides low-noise input characteristics for precision sensing (vsINA327EA/2K5G4)
Catatan Desain
Place the INA327EA/2K5 close to the sensor or bridge, and route the two differential inputs as a matched pair with continuous ground references. Keep the gain-setting resistor close to the pins identified in the manufacturer datasheet because long resistor traces add thermal EMF, pickup, and parasitic capacitance. Avoid switching nodes and high-current return paths beneath the sensitive input area. A solid ground plane and short output route to the ADC will preserve the benefit of the specified 100 dB common-mode rejection.
Do not assume that rail-to-rail input operation permits unrestricted input and output voltages. Check the INA327 datasheet common-mode and output-range graphs against the actual supply voltage, sensor excitation, temperature, and load. The 2.5 gain setting also increases output voltage proportionally, so an input near the upper rail can drive the output into saturation even when the input itself is valid. Include worst-case sensor tolerance and supply variation in the signal-chain simulation before layout release.
For low-level sensor measurements, evaluate total input-referred noise rather than using the 33 nV/√Hz device figure alone. Include sensor noise, resistor noise, source-impedance effects, ADC input noise, and the bandwidth selected by the downstream filter. Keep the gain resistor within the placement area recommended by Texas Instruments and use a clean analog supply path. If the source impedance is high, verify that bias-current-induced offset and capacitance at the input do not dominate the measurement.
The typical supply current is 2.4 mA, but total analog-system consumption also includes the sensor, ADC, regulator quiescent current, and shutdown behavior. Use the shutdown pin only after checking its timing, logic levels, and leakage in the manufacturer datasheet. For duty-cycled systems, allow the output and internal settling time to be included in the measurement cycle. Ensure the source supply can start cleanly at the 2.7 V minimum operating voltage.
Maklumat Kesediaan