MAX485CUA+T Ringkasan

The Analog Devices MAX485CUA+T is a low-power, slew-rate-limited RS-485/RS-422 transceiver with one driver and one receiver, a maximum data rate of 2.5 Mbps, and an 8-pin uMAX/uSOP package. It is designed for bidirectional serial-data links in industrial control, instrumentation, building automation, and point-to-multipoint communications equipment. The uMAX package supports compact PCB layouts where a larger SOIC footprint would be undesirable.

An RS-485/RS-422 transceiver is an interface IC that converts between digital logic levels and balanced differential signals. RS-422 generally describes point-to-point, point-to-multipoint, or multidrop signaling, while RS-485 supports longer networks and more driver nodes under appropriate wiring and termination conditions. This transceiver combines both standards in one device and provides a common interface between a host controller and a physical communication network.

The MAX485CUA+T uses low-power transceiver technology and slew-rate limiting to reduce unwanted radio-frequency emissions caused by fast edge transitions. Its driver and receiver make the device useful in two-way links: the controller can transmit command or data frames through the driver and receive response frames through the receiver. The integrated direction-control architecture allows the device to support half-duplex bus communication when connected in the standard RS-485 configuration.

The 2.5 Mbps maximum signaling rate supports moderate-speed industrial and control traffic while retaining controlled transition behavior. Because transceiver performance also depends on the complete channel, designers must still evaluate cable length, characteristic impedance, termination, protection devices, grounding, and node spacing. The logic-side interface operates from a low-voltage supply, allowing it to pair with modern microcontrollers, field-programmable logic, industrial controllers, and embedded systems.

Typical applications include motor controllers, PLC-to-remote-I/O links, instrumentation, building-control equipment, security systems, and industrial sensors. The MAX485CUA+T is particularly useful when a compact package, low-power operation, and balanced differential signaling are required together. It is also appropriate for custom RS-422 links that need one driver and one receiver in a small 8-pin footprint.

The primary design consideration is the bus network rather than the IC alone. Place termination resistors at the physical ends of the bus, avoid unnecessary stubs, provide a continuous ground reference, and use suitable transient-voltage protection for exposed industrial wiring. Keep the transceiver and protection network close together to minimize unterminated trace length and improve noise immunity.

This page combines verified manufacturer and distributor information with practical interface guidance, unavailable-parameter disclosures, and package-consistent sourcing guidance. It is designed to help engineers verify fit, determine missing datasheet data, and plan an RS-485 or RS-422 implementation without treating incomplete distributor metadata as a substitute for the manufacturer datasheet.

Pilihan pengganti yang segera untuk MAX485CUA+T — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.

Tiada pilihan pengganti yang segera untuk produk ini.

Minta Alternatif

MAX485CUA+T Spesifikasi

Transceiver Configuration 1 driver and 1 receiver
Supported Standards RS-422 and RS-485
Maximum Data Rate 2.5 Mbps
Kemasan 8-pin uMAX/uSOP
Jenis Pemasangan Surface mount
Power Classification Low-power transceiver
Driver Transition Control Slew-rate limited
Number of Drivers 1
Number of Receivers 1

Panduan Konfigurasi Pin MAX485CUA+T 8-pin umax/usop

Konfigurasi pin untuk MAX485CUA+T (8-pin umax/usop pakai). Penomeran pin, fungsi, dan garis bentuk koneksi ditakrifkan dalam dokumen pengeluar. Rujuk dokumen untuk kebentuk dan pedoman pengasman.

Garis bentuk pengecah pakai 8-pin umax/usop untuk MAX485CUA+T

Tiada data garisan pin yang diperoleh untuk MAX485CUA+T.

Rujuk kepada lembaran data untuk konfigurasi pin penuh.

Aplikasi Biasa

MAX485CUA+T patut untuk 6 aplikasis: Industrial PLC Remote I/O, Motor Controller Communication, Building Automation Networks, Instrumentation and Sensor Networks, Security and Access Control, Custom RS-422 Point-to-Point Links.

🏭

Industrial PLC Remote I/O

The MAX485CUA+T fits a compact industrial remote-I/O link because it combines one differential driver and one receiver in an 8-pin uMAX/uSOP package. It can connect a controller UART to a field module over balanced wiring while supporting signaling up to 2.5 Mbps. The slew-rate-limited driver helps reduce edge-related emissions on industrial cabling, but the designer must still provide bus termination, grounding, and surge protection. PCB area is especially valuable in densely populated PLC or I/O-module boards, making the small uMAX footprint more useful than a larger package.

⚡

Motor Controller Communication

The MAX485CUA+T is appropriate for command and status communication between a motor controller and a supervisory controller. Its 1-driver, 1-receiver arrangement supports half-duplex RS-485 operation, while the 2.5 Mbps capability provides ample bandwidth for short control frames. The compact 8-pin uMAX/uSOP package reduces the footprint beside power-stage electronics, although heat and electrical isolation remain separate concerns. Designers should use shielded or properly routed twisted-pair wiring and add protection at the motor harness boundary because motor systems can expose the interface to large switching transients.

🧩

Building Automation Networks

The MAX485CUA+T can support balanced RS-485 communication between a building controller and remote environmental or access modules. The low-power transceiver and small surface-mount package suit distributed control panels where space and standby consumption matter, while the 2.5 Mbps rate exceeds the throughput normally required for sensor polling and HVAC commands. In a building network, the implementation must observe the maximum node count and cable limitations of the selected RS-485 topology. Termination belongs only at the two bus ends, and the ground reference must remain continuous along the cable.

📟

Instrumentation and Sensor Networks

The MAX485CUA+T fits multi-drop instrumentation buses that connect a data-acquisition controller to remote sensors or measurement modules. Its one-driver, one-receiver arrangement and RS-485 capability allow deterministic polling over balanced wiring, and the low-power construction is useful in distributed field equipment. The 8-pin uMAX package preserves board area in compact analyzers and data loggers. For reliable measurement-system behavior, maintain a common ground reference, avoid long unterminated stubs, and use the receiver threshold and common-mode limits in the manufacturer datasheet when setting cable and protection choices.

📷

Security and Access Control

The MAX485CUA+T can provide the physical layer for access-control readers, door controllers, and camera-control panels linked over a short RS-485 bus. The 2.5 Mbps limit provides more bandwidth than required for identification and status packets, and the compact uMAX/uSOP package fits compact controller boards. The device is normally paired with a host microcontroller through serial logic and a direction-control arrangement. Because access-control equipment may have long cable runs, designers should add surge protection, maintain one ground reference, and test the installed wiring for reflections and common-mode excursions.

🌐

Custom RS-422 Point-to-Point Links

The MAX485CUA+T can also implement a compact point-to-point RS-422 link between two circuit boards or between a controller and a remote instrument. Its single driver and single receiver match the basic one-to-one signaling arrangement, while the 2.5 Mbps capability supports substantially faster transfers than typical low-speed control traffic. Differential signaling improves noise immunity over unbalanced wiring. The designer should nevertheless verify the manufacturer's receiver threshold and common-mode limits against the actual cable and ground conditions, and avoid applying multi-drop termination rules unless the chosen topology genuinely includes multiple nodes.

What is the MAX485CUA+T?
The MAX485CUA+T is a low-power, slew-rate-limited RS-485/RS-422 transceiver containing one driver and one receiver in an 8-pin uMAX/uSOP package. According to the Analog Devices MAX485 product information, the MAX485 family is intended for low-power serial communications and supports data rates up to 2.5 Mbps. It is suitable for compact industrial, control, instrumentation, and building-automation interfaces.
What are the key specifications of MAX485CUA+T that engineers should know?
The MAX485CUA+T provides one RS-485/RS-422 driver, one receiver, a maximum data rate of 2.5 Mbps, slew-rate-limited operation, and an 8-pin uMAX/uSOP package. According to the Analog Devices MAX485 product page, the family is designed for low-power RS-485 and RS-422 communication. Verified supplier results also identify the CUA suffix with the compact uMAX package; exact supply voltage, thresholds, and temperature limits require the manufacturer datasheet.
Where can I download the MAX485CUA+T datasheet PDF?
The official MAX485CUA+T datasheet and product resources are available through Analog Devices at https://www.analog.com/en/products/max485.html. The verified search results also provide a Maxim Integrated PDF mirror through AllDataSheet. For design decisions involving supply voltage, receiver thresholds, common-mode range, or absolute maximum ratings, use the Analog Devices document as the controlling source and confirm that the selected order code matches the CUA package.
Where can I find the MAX485CUA+T pinout?
The MAX485CUA+T pinout should be taken from the MAX485 manufacturer datasheet because the verified excerpts do not provide the numbered signal assignments. The device is identified as an 8-pin uMAX/uSOP transceiver. Because the exact uMAX pin numbering is not present in the supplied verified text, this generated record uses a null pinout rather than assigning unverified pin names or numbers. Open the Analog Devices MAX485 documentation before wiring the package.
What is the maximum data rate of MAX485CUA+T?
The MAX485CUA+T supports a maximum signaling rate of 2.5 Mbps. According to the verified FindIC comparison excerpt for MAX485CUA+, the MAX485 family uses slew-rate-limited drivers and can transmit up to 2.5 Mbps. Actual application throughput can be lower because the UART protocol, packet format, response time, bus length, cable characteristics, and termination determine usable link performance.
Where to buy MAX485CUA+T online?
The MAX485CUA+T can be ordered from major distributors, including DigiKey, Mouser, Octopart-listed distributors, LCSC, and specialist sourcing services. DigiKey identifies the exact order code as an 8-uMAX/uSOP RS-422/RS-485 transceiver, while Mouser provides a direct product page. LCSC reports a starting price of $7.0007 and an in-stock listing. Pricing and availability should be reconfirmed at checkout as of 2026-10-29.
What is the price of MAX485CUA+T?
The verified LCSC listing states that MAX485CUA+T is available from $7.0007. That is the only explicit unit-price figure in the supplied search data, so the tier table repeats $7.0007 because no verified quantity-break schedule was provided. The listed commercial reference is therefore as of 2026-10-29, not a guarantee of the price at every order quantity, tax jurisdiction, or freight destination.
Is MAX485CUA+T in stock and what is its lead time?
The verified LCSC result explicitly labels MAX485CUA+T as in stock, and DigiKey states that the part can be purchased and shipped today. No numeric factory lead time was supplied in the verified excerpts, so the quotation lead time cannot be stated without guessing. For production planning, confirm current stock, scheduled delivery dates, and lot traceability directly with the distributor; the inventory observation is current to the retrieved source set for 2026-10-29.
What can replace MAX485CUA+T?
A verified drop-in replacement cannot be named from the supplied excerpts because the cross-reference results do not identify a candidate with a confirmed 8-pin uMAX footprint and matching pin assignments. The MAX485 family options shown as functional equivalents include other package variants, but those are not automatically pin-to-pin replacements. Any substitute must match the CUA package, power ratings, logic thresholds, driver strength, receiver thresholds, and enable or receiver-control behavior before it is treated as drop-in.
Is MAX485CUA+T the same as MAX485CUA-T?
MAX485CUA+T and MAX485CUA-T are not automatically interchangeable order codes, even though verified comparison results place them in the same MAX485 family context. The supplied evidence does not explain whether the suffix difference represents packaging, qualification, or another ordering attribute. Treat the exact suffix as a manufacturer order-code decision and verify the package, qualification, marking, and datasheet status before substituting one for the other.
What is the best cross-brand equivalent for MAX485CUA+T?
The best cross-brand equivalent cannot be confirmed from the supplied verified excerpts because the Hotenda and MaxLinear results describe cross-reference categories but do not expose a candidate MPN, package, and complete electrical comparison. The site-listed SP485ECN-L is a related RS-485 interface device, but the provided evidence does not verify that it uses the same 8-pin uMAX package or is pin-to-pin compatible. It should therefore not be represented as a drop-in replacement without further verification.
MAX485CUA+T versus SP485ECN-L: which is better for a compact RS-485 link?
MAX485CUA+T is the better-supported choice for retaining the verified 8-pin uMAX/uSOP footprint because it is explicitly identified in distributor results as an 8-uMAX/uSOP device. SP485ECN-L is listed in the XAIPART site catalog and is an RS-485 interface option, but the supplied data does not establish its package or pin compatibility. Therefore, choose SP485ECN-L only after its manufacturer documentation confirms an identical footprint and required electrical characteristics.
When should I choose MAX485CUA+T over a larger MAX485 package option?
Choose MAX485CUA+T when PCB area is constrained and the design specifically requires the 8-pin uMAX/uSOP footprint. It preserves the MAX485 family's one-driver, one-receiver RS-485/RS-422 function while reducing package size relative to larger SOIC options. If thermal dissipation, probing access, assembly yield, or exact sourcing requirements favor a larger package, a verified larger-footprint alternative may be easier to inspect and handle even though it is not a literal drop-in replacement.
Is MAX485CUA+T suitable for industrial RS-485 equipment?
The MAX485CUA+T is suitable in principle for industrial RS-485 links because it combines a low-power RS-485/RS-422 transceiver, slew-rate-limited signaling, and a compact surface-mount package. Suitability still depends on the manufacturer ratings for supply voltage, common-mode range, temperature, ESD, and surge exposure. Industrial deployments with long cables or unshielded wiring should also include appropriately rated transient protection and verified surge isolation.
How should termination and protection be designed with MAX485CUA+T?
Terminate the RS-485 bus at the two physical ends, using the resistance specified by the transceiver and system design, and avoid adding termination to every node. Place surge-protection devices close to the connector and transceiver so that transient current is diverted before reaching the IC. Keep the driver, receiver, protection network, and balanced route compact, provide a continuous ground reference, and verify the complete network with the MAX485 manufacturer's application guidance.

Data referensi kejuruteraan untuk MAX485CUA+T — perbandingan, panduan rancangan, dan maklumat kesediaan

Panduan Pilihan

Choose MAX485CUA+T when a compact board needs a single-driver, single-receiver RS-485 or RS-422 interface and the verified 8-pin uMAX/uSOP footprint is required. Its low-power architecture and 2.5 Mbps capability suit control, instrumentation, building-automation, and point-to-point links. Do not substitute a larger MAX485 package solely because the protocol is the same; confirm the physical footprint and every numbered pin. SP485ECN-L may be considered after its package and electrical data are verified, but the supplied evidence does not establish it as a drop-in replacement. MC3486DR is preferable when multiple RS-485 channels justify a larger multi-channel package, while MAX232DR is relevant only for a different unbalanced RS-232 design. Before release, obtain the official MAX485 datasheet, confirm supply and common-mode limits, define termination and protection, and test the completed wiring under the intended node count and cable length.

Perbandingan dengan Gantian

Parametr Produk Ini
Package 8-pin uMAX/uSOP
Brand Analog Devices
Transceiver Configuration 1 driver and 1 receiver
Supported Standards RS-422 and RS-485
Maximum Data Rate 2.5 Mbps
Driver Type Slew-rate limited
Power Classification Low-power transceiver
Mounting Type Surface mount

Penyeberangsung Jelas

  • Compact verified 8-pin uMAX/uSOP implementation (vsSP485ECN-L)
  • Balanced differential transceiver in a single IC (vsMAX232DR)
  • Moderate-speed slew-rate-limited communications (vsMC3486DR)

Catatan Desain

Do not treat every MAX485-family order code as a literal drop-in replacement. The verified material confirms that MAX485CUA+T uses an 8-pin uMAX/uSOP package, while some related listings refer to different package options. Before substitution, compare the package drawing, numbered pin assignments, enable or receiver-control behavior, supply range, logic thresholds, driver loading, and receiver common-mode range. A matched bus protocol alone does not establish electrical or mechanical compatibility.

Route the balanced bus as a differential pair, keep the driver and receiver interface close to the IC, and place any connector-side protection components immediately after the board entry point. Maintain a continuous ground reference beneath or alongside the pair where the application permits. Avoid long unprotected copper stubs, because those sections behave like unterminated transmission lines and can increase ringing, overshoot, and susceptibility to external noise.

The available verified information does not provide the MAX485CUA+T supply-voltage or logic-threshold values, so a new power rail must not be designed from assumptions. Confirm those limits in the manufacturer datasheet and calculate the transceiver's logic and driver demand for the actual UART, termination, protection, and fault-state configuration. Check the power source for startup current, bus contention, and short-circuit behavior before assigning decoupling or regulator capacity.

Install termination only at the two physical ends of the RS-485 bus, not at every node, and verify the resistance against the transceiver's specified load and the cable impedance. Keep stub lengths short and ensure that direction control never enables two drivers onto the bus simultaneously. For long or exposed cables, add surge protection and confirm its voltage, capacitance, and current ratings do not distort the intended 2.5 Mbps signaling behavior.

Maklumat Kesediaan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Bosong logam timbal
Unknown
Bosong halogen
Unknown
Mineral konflik
Unknown

The supplied verified excerpts do not state the applicable RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. These values must be confirmed from the current Analog Devices product documentation before environmental or automotive qualification.

Data disahkan pada: 2026-10-29 — data yang disahkan dan disusun semula oleh pasukan kejuruteraan komponen XAIPART

Pencarian Berhubungan

MAX485CUA+T MAX485CUA+T datasheet PDF Analog Devices MAX485CUA+T MAX485CUA+T 8 pin uMAX MAX485CUA+T RS-485 transceiver MAX485CUA+T 2.5 Mbps MAX485CUA+T RS-485 industrial control MAX485CUA+T vs SP485ECN-L MAX485CUA+T drop-in replacement MAX485CUA+T buy price MAX485CUA+T pinout MAX485CUA+T in stock

Komponen dan Tanda berkaitan

Analog Devices Maxim Integrated MAX485CUA+T MAX485 RS-485 RS-422 RS-232 low-power transceiver differential transceiver line driver line receiver half-duplex communication slew-rate-limited driver 2.5 Mbps 8-pin uMAX/uSOP uMAX package family surface-mount package SMD industrial control building automation instrumentation motor controller L9678P SP485ECN-L MC3486DR
RFRC Saring Pantas
Isikan butiran lengkap — pasukan jualan kami akan bertindak balas dalam masa 24 jam
Nombor Bahagian Pengeluar Pakej QTY Harga Target Lengkap
✓
Pesan diskon sudah disubmit!

Kami akan bertindak balas kepada emel anda dalam tempoh 24 jam

1
RFQ Diserahkan
2
kutipan Diterima
3
Order Dipesan
4
Pembayaran
5
Dihantar
6
Diantar
Lihat Perincian RFQ