SY87701ALHG - 1.3Gbps Any-Rate CDR | Microchip | 32-TQFP
MPN: SY87701ALHG ✓ AktifSY87701ALHG Ringkasan
A clock and data recovery IC, commonly abbreviated CDR, is a timing-recovery device that extracts a stable clock from a serial data stream whose phase relationship to the source clock may vary. A CDR belongs to the clock and timing IC hierarchy, which supports clock generation, distribution, data conversion, and signal recovery in digital communication equipment. The recovered clock can establish a deterministic sampling relationship between a transmitter and receiver across an asynchronous or noisy link.
The SY87701AL uses a phase and frequency detector to compare incoming data transitions with the recovered clock. Its loop filter controls a voltage-controlled oscillator, while the reference clock and selected divide ratio establish the VCO operating range. The integrated architecture supports Any-Rate operation across 28 Mbps to 1.3 Gbps and includes one recovered clock output for systems requiring timing alignment of received data.
The recovered output is particularly useful in serial links where the receiver cannot rely on a source-synchronous clock arriving with adequate phase margin. Clock recovery compensates for propagation delay, interface jitter, and clock-domain offsets encountered across cables, backplanes, optical modules, or board-level interconnects. Because timing errors directly cause sampling misses, the recovered clock must meet the eye-width and jitter budget of the associated data rate.
Typical uses include SONET/SDH and ATM equipment, Fibre Channel interfaces, Ethernet-related links, optical network terminals, and other high-speed serial transmission systems. In these applications, the 1.3 Gbps ceiling provides headroom for legacy SONET/SDH and Fibre Channel paths, while the 28 Mbps lower limit supports lower-rate channels within the same recovery architecture.
PCB design should preserve the high-speed data path by using short, impedance-controlled traces, solid ground planes, and minimal stub branches. The input and output return paths should remain continuous, decoupling should be placed close to the supply pins, and the exposed pad should connect to an uninterrupted ground or thermal plane. Differential and single-ended interfaces must follow the exact reference circuit and termination details in the manufacturer datasheet.
This page organizes the SY87701ALHG timing characteristics, package information, sourcing path, application guidance, and design considerations into one engineering-focused reference. It also distinguishes verified drop-in substitutions from related clock-recovery options so engineers can assess footprint, pin compatibility, and data-rate coverage before changing a production design.
Pilihan pengganti yang segera untuk SY87701ALHG — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.
Tiada pilihan pengganti yang segera untuk produk ini.
Minta AlternatifSY87701ALHG Spesifikasi
| Product Type | Clock and Data Recovery (CDR) integrated circuit |
| Maximum Data Rate | 1.3 Gbps |
| Minimum Data Rate | 28 Mbps |
| Recovered Clock Outputs | 1 output |
| Tegangan Pemberi Arus | 3.3 V |
| Data Format | NRZ |
| Signal Standard | ECL, PECL, and TTL-compatible interface |
| Clock Recovery Architecture | Phase/frequency detector, integral loop filter, and voltage-controlled oscillator |
| Frequency Multiplication | Multiplier PLL with byte-rate source reference |
| Link Fault Detection | Supported |
| Kemasan | 32-pin TQFP with exposed pad, 7 x 7 mm |
| Kiraan Pin | 32 pins |
| Jenis Pemasangan | Surface mount |
| Target Applications | Ethernet, SONET/SDH, ATM, and Fibre Channel |
| Status RoHS | Compliant |
Panduan Konfigurasi Pin SY87701ALHG 32-pin tqfp with exposed pad, 7 x 7 mm
Konfigurasi pin untuk SY87701ALHG (32-pin tqfp with exposed pad, 7 x 7 mm pakai). Penomeran pin, fungsi, dan garis bentuk koneksi ditakrifkan dalam dokumen pengeluar. Rujuk dokumen untuk kebentuk dan pedoman pengasman.
Tiada data garisan pin yang diperoleh untuk SY87701ALHG.
Rujuk kepada lembaran data untuk konfigurasi pin penuh.
Aplikasi Biasa
SY87701ALHG patut untuk 6 aplikasis: SONET and SDH Optical Transport, Fibre Channel Interfaces, ATM Network Equipment, Ethernet Physical-Layer Receive Path, High-Speed Optical Module Receivers, Legacy High-Speed Data Links.
SONET and SDH Optical Transport
The SY87701ALHG suits legacy optical transport links that require clock recovery from NRZ data rates within the 28 Mbps-to-1.3 Gbps range. Position the recovery device at the receiver interface so the data and reference paths remain short and controlled. Its phase/frequency detector, integral loop filter, and voltage-controlled oscillator provide a recovered clock for downstream retiming, while the 3.3 V supply simplifies integration with compatible telecommunications line cards. Verify the optical module's logic levels, reference frequency, loss budget, and maximum jitter before finalizing the interface because those channel characteristics determine whether the recovery loop can maintain stable lock.
Disebarkan
Fibre Channel Interfaces
The SY87701ALHG can support Fibre Channel receiver paths whose NRZ signaling falls between 28 Mbps and 1.3 Gbps. It provides one recovered clock output and a data-retiming function for downstream receiver logic, reducing reliance on a separate source-synchronous clock with uncertain phase. Place it close to the high-speed input connector or transceiver output to minimize trace length and insertion loss. Confirm the Fibre Channel variant, nominal rate, reference-clock configuration, and allowable jitter with the manufacturer datasheet before release, since these requirements vary across legacy and modern link architectures.
Disebarkan
ATM Network Equipment
The SY87701ALHG is appropriate for ATM and related high-speed telecom equipment requiring a recovered timing reference from NRZ data. Its Any-Rate operation across 28 Mbps to 1.3 Gbps allows one architecture to address multiple channel rates, while the single recovered output serves a downstream retiming or packet-processing stage. The device must be accompanied by the required reference clock and interface termination network specified by the manufacturer. Layout should keep the serial data path short, provide a continuous ground reference, and isolate the recovered clock from data routing to limit coupling into the recovery loop.
Disebarkan
Ethernet Physical-Layer Receive Path
The SY87701ALHG can be evaluated for Ethernet-related physical-layer receivers that present NRZ data and require timing recovery within the device's 28 Mbps-to-1.3 Gbps operating span. Its recovered clock and retimed data can feed packet-processing logic when the link is not adequately source-synchronous. The design must satisfy the PHY's output format, voltage levels, reference frequency, jitter tolerance, and loss budget. Because this is an Any-Rate CDR rather than a general-purpose Ethernet PHY, engineers should validate interoperability with the selected PHY and confirm that one recovered clock output satisfies the downstream timing architecture.
Disebarkan
High-Speed Optical Module Receivers
The SY87701ALHG fits receiver-side clock recovery where an optical or copper module delivers NRZ data with phase drift relative to the local reference. By recovering and retiming the stream, the device can create a stable sampling clock for payload processing or forwarding logic. The 1.3 Gbps maximum rate supports demanding legacy optical links, while the 3.3 V supply aligns with many module interfaces. Engineers must check input sensitivity, output thresholds, reference quality, and jitter specifications in the manufacturer datasheet, then provide controlled impedance and uninterrupted return paths in the PCB layout.
Disebarkan
Legacy High-Speed Data Links
The SY87701ALHG is useful for legacy proprietary and industrial serial links that operate between 28 Mbps and 1.3 Gbps but lack a dependable forwarded clock. Its phase/frequency detection and VCO-based loop allow the receiver to establish alignment from the data transitions themselves. The recovered clock can drive a retiming register or a downstream controller, while the retimed data path supports repeatable sampling. Before implementation, characterize the transmitter's jitter, line loss, data format, reference frequency, and power-up behavior. Maintain short, impedance-controlled traces and place the CDR near the receiver to prevent additional jitter and attenuation from degrading margin.
Disebarkan
Ringkasan Produk Disebarkan
Data referensi kejuruteraan untuk SY87701ALHG — perbandingan, panduan rancangan, dan maklumat kesediaan
Panduan Pilihan
Perbandingan dengan Gantian
| Parametr | Produk Ini |
|---|---|
| Brand | Microchip Technology |
| Package | 32-pin TQFP with exposed pad, 7 x 7 mm |
| Maximum Data Rate | 1.3 Gbps |
| Minimum Data Rate | 28 Mbps |
| Supply Voltage | 3.3 V |
| Recovered Clock Outputs | 1 output |
| Data Format | NRZ |
| Target Applications | Ethernet, SONET/SDH, ATM, and Fibre Channel |
| Link Fault Detection | Supported |
| RoHS Status | Compliant |
Catatan Desain
Keep the recovered data and reference paths short, impedance controlled, and referenced to a continuous ground plane. Route the CDR input close to the receiver or transceiver rather than allowing the high-speed signal to cross unrelated digital routes. The exposed pad should connect to a low-impedance ground plane using multiple short vias where required by the manufacturer land pattern. These steps reduce insertion loss, crosstalk, and ground bounce that can consume the clock-recovery timing budget.
Decouple the 3.3 V supply close to the device's supply pins and preserve the manufacturer-specified reference and bypass network. Place high-frequency bypass capacitance at the pins, with any additional bulk capacitance located near the supply source. Avoid routing the recovered clock or high-speed data return path through the power-distribution network, because supply coupling can appear as jitter or phase disturbance in the recovery loop.
Validate the complete receiver path with the selected reference clock, data source, terminations, and expected channel loss. The phase/frequency detector and VCO can compensate only within the loop's jitter and acquisition limits, so extra trace loss or an unstable reference can prevent reliable lock. Confirm voltage thresholds, input/output logic levels, reference ratio, and supported channel rate directly from the manufacturer datasheet before releasing the layout.
Maklumat Kesediaan
The verified distributor listing identifies SY87701ALHG as RoHS compliant. No additional compliance declarations are specified.