Analog Devices

AD7884AP - 16-Bit 166 kSPS Parallel ADC | Analog Devices

MPN: AD7884AP ✓ Active
PLCC-44, 16.6 mm × 16.6 mm Package
MOQ: 1 |

AD7884AP Overview

Analog Devices AD7884AP is a 16-bit monolithic analog-to-digital converter with an internal sample-and-hold circuit, a 5.3 µs conversion time, and a maximum throughput rate of 166 kSPS. The device is offered in a PLCC-44 package and uses a two-pass flash conversion architecture for parallel-output data acquisition.

An analog-to-digital converter, or ADC, converts an analog input voltage into a digital code for processing by a microprocessor, microcontroller, DSP, or data-acquisition system. The AD7884 belongs to the ADC > data converter > semiconductor hierarchy. Its parallel reading structure presents a newly converted 16-bit result through a dedicated bus, avoiding the serial-interface overhead associated with many high-resolution converters.

The principal performance characteristics include 16-bit resolution, 166 kSPS maximum throughput, and 5.3 µs conversion time. Two input ranges are available: ±5 V and ±3 V. Conversion is initiated by the CONVST signal, while chip-select and read signals control access to the conversion results. An internal sample-and-hold stage supports complete acquisition of the input voltage during each conversion cycle.

The two-pass flash architecture is the key technical feature behind the converter’s throughput. Unlike a single-pass flash ADC, the two-pass implementation performs successive conversion stages to resolve the full 16-bit result. This architecture suits applications requiring accurate acquisition at higher sampling rates than conventional successive-approximation converters, particularly when parallel-output timing is acceptable.

Typical uses include industrial process measurement, instrumentation, waveform acquisition, laboratory data acquisition, and multichannel control systems. The PLCC-44 package provides a conventional leaded surface-mount footprint and is suited to boards where a compact QFN or BGA package would complicate assembly or inspection. Parallel data routing must remain short and properly terminated to preserve conversion-result integrity.

Designers should verify signal range, acquisition time, settling behavior, digital-interface timing, and reference requirements against the manufacturer application information before finalizing the PCB. Keep the analog input and reference paths away from high-current switching nodes, provide stable reference and bypass connections, and ensure the host processor meets the specified conversion and read timing.

This page combines the AD7884AP technical characteristics with package guidance, selection criteria, application fit, and verified manufacturer documentation. It also distinguishes confirmed pin-compatible replacements from broader functional similarities so engineers can evaluate interchangeability without assuming that a similar converter is a safe drop-in replacement.

Drop-in alternatives for AD7884AP — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

AD7885AAP

✅ Drop-In
📦 PLCC-44
The Analog Devices datasheet states that AD7885AAP has the same specifications as AD7884AP; published resolution, conversion time, and throughput are identical at 16 bit, 5.3 µs, and 166 kSPS.

📋 Reference alternative (not in catalog)

AD7884AP Maximum Ratings & Electrical Characteristics

Resolution 16 bit
Architecture Two-pass flash architecture
Converter Type Monolithic analog-to-digital converter
Sample-and-Hold Internal
Conversion Time 5.3 µs
Maximum Throughput Rate 166 kSPS
Input Range Option 1 ±5 V
Input Range Option 2 ±3 V
Output Structure 16-bit parallel reading structure
Conversion Start Signal CONVST
Read Control Signals CS and RD
Package PLCC-44, 16.6 mm × 16.6 mm
Mounting Style Surface mount
Production Status Production
Document Revision Rev. E

AD7884AP plcc-44, 16.6 mm × 16.6 mm Pin Configuration Guide

Pin configuration for AD7884AP (plcc-44, 16.6 mm × 16.6 mm package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.

plcc-44, 16.6 mm × 16.6 mm package pinout diagram for AD7884AP

No detailed pinout data available for AD7884AP.

Refer to the datasheet for full pin configuration.

Typical Applications

AD7884AP is suitable for 6 applications: Industrial Process Measurement, Laboratory Data Acquisition, Precision Waveform Capture, Multichannel Monitoring System, Portable Measurement Instrument, Control System Feedback.

🏭

Industrial Process Measurement

The AD7884AP fits process-measurement channels that require 16-bit numerical resolution and a sampling capability of up to 166 kSPS. Its internal sample-and-hold circuit acquires the conditioned analog input, while the ±5 V or ±3 V input-range options accommodate bipolar sensor signals after suitable scaling. The two-pass flash architecture completes conversion in 5.3 µs, allowing the controller to sample multiple variables more rapidly than a low-speed successive-approximation design. Install the converter close to the analog front end, route the parallel bus to the processor, and isolate the measurement chain from motor and switching-node energy. The AD7884BP and AD7885AAP are related ADC options to evaluate when temperature grade or ordering-code requirements differ.

🔧

Laboratory Data Acquisition

The AD7884AP is appropriate for laboratory instruments that collect moderately high-rate waveforms while preserving 16-bit measurement resolution. A sampling rate of 166 kSPS and conversion time of 5.3 µs provide enough timing margin for synchronized acquisition of control, sensor, or diagnostic signals. The dedicated parallel result bus can transfer each 16-bit conversion directly into a processor or capture logic, avoiding serial-clock overhead. The PLCC-44 package also remains practical for laboratory boards that use conventional leaded surface-mount assembly rather than fine-pitch BGA or QFN routing. For reliable measurements, use a quiet reference, short analog traces, controlled grounding, and acquisition software synchronized to CONVST and the CS/RD read cycle.

📈

Precision Waveform Capture

The AD7884AP supports precision waveform capture when the signal bandwidth is compatible with its 166 kSPS maximum throughput. Sixteen-bit resolution preserves fine amplitude detail, while the internal sample-and-hold function and 5.3 µs conversion time provide predictable acquisition timing. The parallel reading structure suits instrumentation that already includes a microprocessor interface and requires rapid access to completed samples. Place anti-alias filtering before the converter, keep the input path compact, and design the digital bus so processor timing does not overlap incorrectly with the CONVST and read-control sequence. The AD7710AR and AD7708BR can be considered for channels where lower conversion speed is acceptable and integrated signal conditioning is more important than parallel throughput.

🖥️

Multichannel Monitoring System

The AD7884AP can form the fast conversion element of a multichannel monitoring system when several analog variables require synchronized acquisition. Its 166 kSPS throughput permits a higher sampling rate than slower multi-channel converter families, while the 16-bit parallel output provides a direct numerical result to a host processor. Engineers should design an analog multiplexer or simultaneous sampling front end around the permitted input range and acquisition time, and keep each switched channel settled before CONVST is asserted. The AD7885AAP offers a closely related same-specification option, while AD7876CR and AD7876BR can be evaluated for adjacent channels where throughput requirements are less demanding and overall channel architecture favors their conversion characteristics.

📱

Portable Measurement Instrument

The AD7884AP fits portable measurement equipment that must balance numeric resolution, conversion speed, and inspectable component packaging. Its 16-bit resolution provides detailed readings, while 166 kSPS throughput supports responsive acquisition without moving to a much slower converter architecture. The PLCC-44 package uses leads that can facilitate visual inspection and rework compared with fine-pitch land patterns, although it occupies more board area than a compact leadless package. Battery-powered implementations should account for the converter's power dissipation and system shutdown strategy using the manufacturer electrical data. The AD7884BP and AD7885AAP are useful alternatives to screen when temperature grade, availability, or ordering-code requirements affect the final choice.

⚙️

Control System Feedback

The AD7884AP can provide a fast feedback path in control systems that need more conversion resolution and speed than a general-purpose slow ADC. The 5.3 µs conversion time and 166 kSPS maximum throughput make the device suitable for monitoring pressure, position, current, or other conditioned feedback variables. A typical implementation places the converter between an analog front end and a processor or DSP, using CONVST to initiate conversion and CS/RD to transfer the parallel result. Design the analog path for acquisition settling and use a stable reference to preserve code accuracy. The AD7885AAP provides a directly documented same-specification candidate, while the AD7876CR and AD7876BR should be compared when their channel architecture better matches the surrounding system.

What is the AD7884AP?
The AD7884AP is a 16-bit monolithic parallel-output ADC from Analog Devices with an internal sample-and-hold circuit and a maximum sampling rate of 166 kSPS. According to the Analog Devices AD7884/AD7885 datasheet, it uses a two-pass flash architecture, completes conversion in 5.3 µs, and provides input-range options of ±5 V and ±3 V. The AD7884AP is packaged in PLCC-44 and is intended for applications that can accommodate a dedicated parallel data bus and conventional leaded surface-mount assembly.
What is the conversion time of AD7884AP?
The AD7884AP has a conversion time of 5.3 µs and a maximum throughput rate of 166 kSPS. According to the Analog Devices AD7884/AD7885 datasheet, conversion is initiated by the CONVST signal, after which the result can be accessed using the CS and RD control signals. This timing suits instrumentation and process-control systems that must acquire high-resolution samples without using a serial ADC interface.
What is the resolution and input range of AD7884AP?
The AD7884AP provides 16-bit resolution with two analog input-range options: ±5 V and ±3 V. According to the Analog Devices AD7884/AD7885 datasheet, the converter includes an internal sample-and-hold circuit and a two-pass flash architecture. Select the range according to the signal amplitude, front-end attenuation, and full-scale calibration requirements of the measurement channel.
Where can I download the AD7884AP datasheet PDF?
The official AD7884/AD7885 datasheet PDF is available from Analog Devices at https://www.analog.com/media/en/technical-documentation/data-sheets/AD7884_7885.pdf. It contains the AD7884AP electrical characteristics, timing, pin descriptions, architecture information, and application guidance. The manufacturer product page at https://www.analog.com/en/products/ad7884.html provides the corresponding product overview and documentation links.
Where can I find the AD7884AP pinout?
The AD7884AP pinout is shown in the Analog Devices AD7884/AD7885 datasheet under the pin-description and pin-configuration sections. The device is a 44-lead PLCC package, so the physical pin assignments should be transferred directly from the manufacturer drawing rather than inferred from a generic PLCC outline. Use that drawing to assign the 16-bit parallel bus, CONVST, CS, RD, analog inputs, supplies, and reference connections.
What is the AD7884AP vs AD7884BP difference?
The AD7884AP and AD7884BP are related AD7884-family variants, but the available manufacturer information does not establish that they share the same physical package and pinout. According to the AD7884/AD7885 datasheet, AD7884BP is associated with the AD7885ABP specification family, while AD7884AP is a PLCC-44 device. Because package suffixes can denote different package and temperature options, confirm the ordering information and compare every pin before treating either part as a replacement.
When should I choose AD7884AP over a serial-interface ADC?
Choose the AD7884AP when 16-bit parallel data transfer, a 166 kSPS maximum rate, and a 5.3 µs conversion time are more important than minimizing interface pin count. According to the Analog Devices AD7884/AD7885 datasheet, the dedicated parallel structure can reduce data-retrieval overhead for processors with suitable bus logic. A serial ADC is generally preferable when board space, wiring complexity, and connector count dominate the design.
Can AD7885AAP replace AD7884AP?
The AD7885AAP is the closest documented same-package alternative because the Analog Devices datasheet states that it has the same specifications as the AD7884AP. Both are associated with the AD7884/AD7885 16-bit, 166 kSPS converter family. Before substitution, verify the ordering table, temperature grade, pin configuration, and timing details against the exact revision of the manufacturer datasheet.
What is the best drop-in replacement for AD7884AP?
The AD7885AAP is the best-supported drop-in candidate identified for the AD7884AP because the Analog Devices AD7884/AD7885 datasheet explicitly states that the AD7885AAP has the same specifications as the AD7884AP. A cross-brand replacement cannot be confirmed from the documented cross-reference material. Use the Request a Quote form on this page for sourcing assistance, and require a manufacturer-backed pin, timing, range, and qualification comparison before releasing a substitute.
Is AD7884AP suitable for industrial process measurement?
The AD7884AP is suitable for industrial process measurement when the selected ±5 V or ±3 V input range, 16-bit resolution, and 166 kSPS sampling capability satisfy the measurement bandwidth and accuracy requirements. According to the Analog Devices AD7884/AD7885 datasheet, it includes internal sample-and-hold circuitry and a two-pass flash architecture. Practical implementation still requires suitable input conditioning, isolation where required, reference design, calibration, and environmental protection.
How should I power and decouple the AD7884AP?
Use the supply voltage, bypass-capacitor values, grounding arrangement, and sequencing requirements specified in the Analog Devices AD7884/AD7885 datasheet. Place required bypass capacitors close to their associated supply pins and use a low-impedance ground plane. Because the exact supply values and capacitor recommendations are not stated on the product-page summary, consult the electrical-characteristics and application sections before finalizing component selection.
How does the two-pass flash architecture affect AD7884AP performance?
The AD7884AP uses a two-pass flash architecture to deliver 16-bit resolution at up to 166 kSPS. According to the Analog Devices AD7884/AD7885 datasheet, conversion takes 5.3 µs and is initiated through CONVST. This approach provides substantially higher throughput than many successive-approximation converters while using a parallel reading structure, making digital timing and board routing important parts of the system design.
What can replace AD7884AP?
The AD7885AAP is the documented same-family replacement candidate for the AD7884AP because the Analog Devices datasheet states that both have the same specifications. No cross-brand part is confirmed as both pin-compatible and electrically equivalent by the available cross-reference information. Treat any other candidate as a functional alternative until its package, pinout, conversion timing, input range, reference arrangement, and environmental qualification have been validated.
Is AD7884AP the same as AD7885AAP?
The AD7885AAP has the same published specifications as the AD7884AP, including 16-bit resolution, 5.3 µs conversion time, 166 kSPS throughput, and the two-pass flash architecture. According to the Analog Devices AD7884/AD7885 datasheet, the devices are closely related members of the same converter family. Engineers should still compare ordering codes and the exact datasheet revision before using them interchangeably.
What are the key specifications of AD7884AP that engineers should know?
The AD7884AP is a 16-bit monolithic ADC with internal sample-and-hold, a 5.3 µs conversion time, and up to 166 kSPS throughput. According to the Analog Devices AD7884/AD7885 datasheet, it uses a two-pass flash architecture, offers ±5 V and ±3 V input ranges, and supports conversion through CONVST with results read through a 16-bit parallel interface. The device is offered in a 44-lead PLCC package for surface-mount assembly.
What is the best cross-brand equivalent for AD7884AP?
No cross-brand equivalent can be confirmed as a true drop-in replacement for the AD7884AP from the documented cross-reference material. A valid substitute would need the same PLCC-44 footprint, 16-bit parallel interface, 16-bit resolution, 166 kSPS-class throughput, 5.3 µs-class conversion timing, and compatible ±5 V or ±3 V input ranges. Use the Request a Quote form on this page for sourcing support, but require a detailed manufacturer comparison before substitution.
Where can I buy AD7884AP and what is the lead time?
Use the Request a Quote form on this page to ask about AD7884AP availability, current lead time, and order quantity. The Analog Devices product page identifies the AD7884 as production, but current inventory and delivery schedules can vary by package code and order volume. The form provides a direct route for obtaining a current quote and supply confirmation without relying on static catalog prices.

Engineering reference data for AD7884AP — comparison, design guidance, and compliance information.

Selection Guide

Choose the AD7884AP when a system requires 16-bit resolution, up to 166 kSPS sampling, a 5.3 µs conversion time, and a parallel result interface in a PLCC-44 package. Select the AD7885AAP when its documented identical specifications meet the design and its ordering information is preferred for procurement. The AD7884BP should be selected only after confirming whether its package, temperature grade, and electrical limits satisfy the board rather than assuming family-level compatibility. No cross-brand substitute is recommended without a manufacturer-supported comparison covering the footprint, all 44 pins, conversion timing, acquisition behavior, input range, reference requirements, supply limits, and qualification. For new compact products, also weigh whether the larger leaded PLCC footprint, parallel-bus routing, and 44-pin routing remain preferable to a smaller serial-interface converter.

Comparison with Alternatives

Parameter This Product AD7885AAP
Brand Analog Devices Analog Devices
Package PLCC-44 PLCC-44
Resolution 16 bit 16 bit
Conversion Time 5.3 µs 5.3 µs
Maximum Throughput 166 kSPS 166 kSPS
Architecture Two-pass flash Two-pass flash
Input Ranges ±5 V and ±3 V ±5 V and ±3 V
Sample-and-Hold Internal Internal
Output Structure 16-bit parallel 16-bit parallel
Conversion Control CONVST CONVST

Key Differentiators

  • Identical documented core specifications (vs AD7885AAP)
  • Parallel output supports direct processor acquisition (vs AD7885AAP)
  • Internal acquisition simplifies analog front-end design (vs AD7885AAP)

Design Notes

Route the 16-bit parallel data bus as a short, continuous group from the AD7884AP to the receiving logic. Provide a solid ground plane and avoid splitting the return path beneath the converter. The PLCC-44 footprint has 44 leads, so assign connector and processor pin locations before layout to prevent bus crossings. Confirm clearance, solder-profile, and land-pattern dimensions against the current Analog Devices package drawing.

Design the analog input path for the selected ±5 V or ±3 V range, including adequate settling time before CONVST is asserted. Keep the input trace short, protect it from switching nodes, and use the reference and bypass connections shown by Analog Devices. Since acquisition time and input impedance are not stated in the product-page summary, use the detailed datasheet for source-impedance calculations and input-filter component selection.

Do not treat AD7884AP, AD7884BP, and AD7885AAP as interchangeable solely because their names are similar. Confirm the ordering code, package drawing, temperature range, pin functions, conversion timing, and reference arrangement. The AD7885AAP is specifically documented as having the same specifications as AD7884AP, whereas the available material does not establish a drop-in relationship for AD7884BP.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

The manufacturer product-page summary identifies the AD7884 as production but does not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. A comparison listing marks RoHS as N, but that third-party field was not treated as definitive manufacturer compliance data.

Related Searches

AD7884AP datasheet AD7884AP datasheet pdf AD7884AP pinout AD7884AP equivalent AD7884AP replacement AD7884AP cross reference AD7884AP vs AD7885AAP AD7884AP 16-bit ADC AD7884AP 166 kSPS AD7884AP PLCC-44 footprint Analog Devices AD7884AP AD7884AP price

Related Components & Terms

Analog Devices AD7884AP AD7885AAP AD7884BP AD7885ABP AD7891AP-2REEL analog-to-digital converter ADC data converter semiconductor 16-bit resolution 166 kSPS 5.3 µs conversion time two-pass flash architecture internal sample-and-hold parallel reading structure CONVST CS RD PLCC-44 surface mount industrial process measurement laboratory data acquisition waveform capture input range
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details