ADAQ7769-1BCPZ - 24-Bit 1MSPS μModule DAQ | Analog Devices
MPN: ADAQ7769-1BCPZ ✓ Active| Qty | Unit Price | Extended |
|---|---|---|
| 1 | $45.32 | $45.32 |
| 10 | $41.87 | $418.70 |
| 100 | $36.54 | $3,654.00 |
| 500 | $32.1 | $16,050.00 |
| 1,000 | $28.75 | $28,750.00 |
Drop-in alternatives for ADAQ7769-1BCPZ — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Quick Comparison Tool — Select alternative parts for side-by-side comparison:
ADAQ7769-1BBCZ
✅ Drop-In📋 Reference alternative (not in catalog)
ADAQ7769-1BCPZ Maximum Ratings & Electrical Characteristics
| Resolution | 24 bit |
| Sample Rate (Max) | 1 MSPS |
| Number of Channels | 1 |
| Input Type | Programmable Gain Amplifier (PGA) |
| Input Impedance | High |
| Reference Voltage (Typical) | 4.096 V |
| Reference Voltage Range | 1 V to VDD_ADC |
| Interface | SPI |
| Package | 84-CSPBGA (12x6) |
| Mounting Type | Surface Mount |
| Operating Temperature Range | [DATA_NEEDED: Operating temperature range] |
| Supply Voltage | [DATA_NEEDED: Supply voltage range] |
| Power Dissipation | [DATA_NEEDED: Power dissipation] |
| RoHS Status | Compliant |
| Reference Buffer Types | Precharge or Full |
ADAQ7769-1BCPZ Pin Configuration
| Pin A1 | VDD_ADC — ADC power supply |
| Pin A2 | GND — Ground |
| Pin A3 | VIN+ — Positive analog input |
| Pin A4 | VIN- — Negative analog input |
| Pin B1 | REFIN — Reference input |
| Pin B2 | REFOUT — Reference output |
| Pin B3 | SCLK — SPI clock |
| Pin B4 | SDI — SPI data input |
| Pin C1 | SDO — SPI data output |
| Pin C2 | CS — Chip select |
| Pin C3 | RESET — Reset pin |
| Pin C4 | MODE — Configuration mode select |
Safe Operating Area (SOA) & Thermal Characteristics
No official SOA curve available for this component. Always operate within absolute maximum ratings specified in the datasheet. Ensure adequate cooling and derate as needed.
Typical Applications
ADAQ7769-1BCPZ is suitable for 6 applications: Precision Data Acquisition Systems, Industrial Process Control, Vibration Monitoring, Portable Instrumentation, Medical Monitoring, Test and Measurement.
Precision Data Acquisition Systems
The ADAQ7769-1BCPZ is ideal for precision DAQ systems requiring high resolution and high speed. Its 24-bit resolution and 1 MSPS sample rate enable accurate capture of fast-changing signals. The integrated PGA and filter simplify design, reducing component count and board space. According to the datasheet, the device supports reference voltages from 1V to VDD_ADC, allowing optimization for various input ranges. This makes it suitable for applications like automated test equipment and laboratory instruments where accuracy and speed are critical.
Recommended
Industrial Process Control
In industrial process control, the ADAQ7769-1BCPZ provides high-precision measurement of sensor signals such as temperature, pressure, and flow. Its high input impedance PGA allows direct connection to sensors without additional buffering, reducing signal degradation. The alias-free architecture eliminates the need for external anti-aliasing filters, simplifying design and improving reliability. With a sample rate of 1 MSPS, it can handle fast control loops, making it suitable for real-time monitoring and control systems.
Recommended
Vibration Monitoring
The ADAQ7769-1BCPZ is well-suited for vibration monitoring applications, such as condition monitoring of rotating machinery. Its 24-bit resolution and 1 MSPS sample rate allow accurate capture of high-frequency vibration signals from accelerometers. The integrated PGA provides programmable gain to match sensor output levels, while the high input impedance minimizes loading effects. The compact μModule package enables deployment in space-constrained sensor nodes, and the SPI interface simplifies data transfer to a host processor.
Recommended
Portable Instrumentation
For portable instrumentation, the ADAQ7769-1BCPZ offers a compact, low-power solution for high-precision measurements. Its integrated signal conditioning reduces external component count, saving board space and power. The device supports a wide reference voltage range, allowing optimization for battery-powered operation. The SPI interface enables low-power communication with microcontrollers, and the μModule package simplifies assembly. This makes it ideal for handheld multimeters, data loggers, and field measurement devices.
Recommended
Medical Monitoring
In medical monitoring, the ADAQ7769-1BCPZ provides high-precision acquisition of physiological signals such as ECG and EEG. Its 24-bit resolution ensures accurate detection of small signal variations, while the high input impedance prevents loading of biological signals. The integrated PGA allows adjustment of gain to suit different sensor types. The compact package and low power consumption make it suitable for wearable and portable medical devices. The alias-free architecture reduces noise, improving signal quality for diagnostic purposes.
Recommended
Test and Measurement
The ADAQ7769-1BCPZ is ideal for test and measurement equipment, such as spectrum analyzers and data acquisition cards. Its high sample rate and resolution enable accurate capture of transient signals. The integrated filter simplifies anti-aliasing, and the programmable gain allows adaptation to various input levels. The SPI interface facilitates integration with FPGAs or DSPs for real-time processing. The μModule package reduces design time and ensures consistent performance across units.
Recommended
Recommended Products Summary
Engineering reference data for ADAQ7769-1BCPZ — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | ADAQ7769-1BBCZ | AD7768-1BCPZ | AD7689BCPZ |
|---|---|---|---|---|
| Package | 84-CSPBGA (12x6) | 84-CSPBGA (12x6) | 28-LFCSP EP | 20-LFCSP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Resolution | 24 bit | 24 bit | 24 bit | 16 bit |
| Sample Rate (Max) | 1 MSPS | 1 MSPS | 1.024 MSPS | 250 kSPS |
| Input Type | PGA | PGA | Differential | 8-channel MUX |
| Interface | SPI | SPI | SPI | SPI |
| Integrated Filter | Yes | Yes | Yes | No |
| Reference Voltage Range | 1V to VDD_ADC | 1V to VDD_ADC | [DATA_NEEDED] | 2.3V to 5.5V |
Key Differentiators
- Integrated μModule design (vs AD7768-1BCPZ)
- High input impedance PGA (vs AD7689BCPZ)
- Alias-free architecture (vs AD7689BCPZ)
Design Notes
Ensure clean power supplies for the ADAQ7769-1BCPZ. Use low-noise LDO regulators and decouple each supply pin with 0.1uF and 10uF capacitors. The device's performance is highly dependent on supply noise, so proper filtering is critical for achieving the specified 24-bit resolution.
For optimal performance, place the reference decoupling capacitors close to the REFIN and REFOUT pins. Use a solid ground plane and avoid routing digital signals near the analog input pins. The datasheet recommends a 4-layer PCB with dedicated analog and digital ground planes to minimize noise coupling.
Do not exceed the absolute maximum ratings for supply voltage and input pins. Ensure the reference voltage is within the specified range (1V to VDD_ADC) to avoid incorrect conversions. Also, configure the device correctly via SPI or pin strapping to match your application's sample rate and gain settings.
Compliance Information
RoHS compliance indicated by distributor listings. Other compliance data not specified in provided sources.