Analog Devices

ADE7755ARSZRL - Single-Phase Energy Meter IC | Analog Devices

MPN: ADE7755ARSZRL ✗ End of Life
In Stock Ships in 1-3 business days
24-pin SSOP Package
Contact for pricing
MOQ: 1 |
Price updated: 2026-10-20
Volume Pricing
Qty Unit Price Extended
1 $0 $0.00
10 $0 $0.00
100 $0 $0.00
500 $0 $0.00
1,000 $0 $0.00
ℹ️ All prices are in USD

ADE7755ARSZRL Overview

The Analog Devices ADE7755ARSZRL is a single-phase energy-metering integrated circuit with a pulse output, supplied in a 24-pin SSOP package. It is designed for high-accuracy electrical energy measurement and is identified by Analog Devices as an energy metering IC whose performance surpasses the accuracy requirements quoted in IEC 1036. The device combines analog-to-digital conversion, reference circuitry, digital signal processing, and energy accumulation for metering systems.

An energy-metering IC is a specialized data-acquisition and power-management semiconductor used to measure voltage and current, calculate electrical energy, and provide a pulse or digital indication to the host system. The ADE7755 places its multiplication and filtering functions in the digital domain, while the only analog circuitry is associated with the ADCs and reference circuit. This architecture is intended to improve measurement stability and reduce sensitivity to analog component variation.

The ADE7755 is suited to single-phase utility meters, residential energy monitors, load-management equipment, industrial energy measurement, and smart-grid sensing nodes. Its pulse output provides a convenient interface for meter calibration, energy accumulation, or host-system counting. The ADE7755 is available in the ADE7755ARSZRL ordering code, identified in distributor results as a 24-SSOP tape-and-reel part.

The 24-pin SSOP package provides the physical interface for analog inputs, digital control, communication, and pulse-output functions. Designers should follow the manufacturer datasheet for exact pin assignments, recommended current and voltage sensing circuits, calibration procedures, filtering values, and electrical limits. The verified distributor descriptions identify the ADE7755 as a single-phase meter IC with pulse output and do not provide a complete set of numeric operating specifications in the supplied search results.

A key design consideration is maintaining the integrity of the voltage and current sensing path. Input filtering, resistor matching, reference stability, clock selection, PCB isolation, and calibration determine whether the meter's achieved accuracy matches its calculation capability. In a production design, evaluate the complete analog front end rather than relying on IC specifications alone.

This page synthesizes the verified manufacturer product description, distributor availability information, package identification, and engineering-oriented application guidance. It distinguishes documented facts from parameters that require confirmation in the manufacturer datasheet, helping engineers evaluate whether the ADE7755ARSZRL is appropriate for a new metering design.

Drop-in alternatives for ADE7755ARSZRL — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

No drop-in alternatives available for this product.

Request Alternatives

ADE7755ARSZRL Maximum Ratings & Electrical Characteristics

Product Type Single-phase energy metering IC
Output Interface Pulse output
Package 24-pin SSOP
Mounting Type Surface mount
Tape-and-Reel Packaging Yes
Manufacturer Reference Standard IEC 1036
Signal Processing Digital-domain multiplication and filtering
Analog Circuitry ADC and reference circuitry

ADE7755ARSZRL 24-pin ssop Pin Configuration Guide

Pin configuration for ADE7755ARSZRL (24-pin ssop package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.

24-pin ssop package pinout diagram for ADE7755ARSZRL

No detailed pinout data available for ADE7755ARSZRL.

Refer to the datasheet for full pin configuration.

Typical Applications

ADE7755ARSZRL is suitable for 6 applications: Residential Single-Phase Smart Meter, Utility Load-Monitoring Terminal, Residential Energy Monitor, Smart-Grid Sensor Node, Industrial Equipment Energy Meter, Calibration and Test Equipment.

🏠

Residential Single-Phase Smart Meter

The ADE7755ARSZRL is suited to a residential single-phase smart meter because the verified distributor information identifies it as a single-phase meter IC with pulse output. It can measure the electrical quantities needed for energy accumulation while the host system counts pulse events or applies additional digital processing. The device’s digital-domain multiplication and filtering can simplify the measurement architecture, but final accuracy still depends on the current-sensor network, voltage divider, reference quality, and calibration. Confirm the official ADE7755 pinout, input limits, supply requirements, and metrology conditions before laying out the meter PCB.

🌐

Utility Load-Monitoring Terminal

For utility load-monitoring terminals, the ADE7755ARSZRL provides the metering core for a single-phase energy measurement path and a pulse output that can be counted or forwarded by surrounding electronics. Its digital processing approach can reduce dependence on analog multiplier stability, while the analog front end remains concentrated around the ADCs and reference circuit as described by Analog Devices. A practical design must still address surge, conducted noise, grounding, sensor isolation, and calibration drift. The verified source does not specify terminal communication interfaces or operating limits, so those details require datasheet confirmation.

📊

Residential Energy Monitor

The ADE7755ARSZRL can form the measurement front end of a residential energy monitor that displays or transmits consumption data. Its pulse output provides a straightforward energy-counting interface, while the ADE7755 family’s digital-domain multiplication and filtering supports consistent calculation across operating conditions. For accurate results, use the manufacturer’s recommended current and voltage sensing networks and account for component tolerance and temperature effects. The verified sources do not provide display-interface specifications, so a host microcontroller or display controller must be selected separately.

🧩

Smart-Grid Sensor Node

In a smart-grid sensor node, the ADE7755ARSZRL can serve as the single-phase energy-measurement device feeding a communications and data-processing subsystem. The manufacturer describes the ADE7755 as a high-accuracy electrical energy measurement IC and states that its performance surpasses the accuracy requirements quoted in IEC 1036. That makes the part relevant to energy monitoring nodes, although compliance and accuracy claims must be checked against the exact test conditions. Designers should also evaluate network isolation, electromagnetic robustness, enclosure temperature, and the regulatory requirements of the deployed grid equipment.

🏭

Industrial Equipment Energy Meter

ADE7755ARSZRL can be evaluated for industrial equipment energy metering where a single-phase load must be measured and accumulated. The pulse output allows the result to be integrated into a counter or supervisory controller, while the digital processing architecture can simplify the measurement chain after the analog front end. Industrial use requires careful review of operating-temperature limits, supply regulation, input transients, isolation, enclosure grounding, and calibration stability; those numeric limits are not present in the supplied verified data. The device should therefore be selected only after checking the full manufacturer datasheet and completing system-level accuracy tests.

🧪

Calibration and Test Equipment

The ADE7755ARSZRL pulse output can be useful in calibration and test equipment that verifies energy accumulation behavior or compares a meter channel against a reference source. The single-phase architecture and pulse indication make it possible to observe energy events externally without depending on undocumented internal calculations. A useful test fixture must provide controlled voltage and current excitation, accurate timing, appropriate load timing, and an independent energy reference. The verified information does not state pulse-width, maximum-frequency, or test-current limits, so the fixture must be designed from the official ADE7755 datasheet and application guidance.

What is the ADE7755ARSZRL?
The ADE7755ARSZRL is an Analog Devices single-phase energy-metering IC with a pulse output, supplied in a 24-pin SSOP package. According to the Analog Devices product page, the ADE7755 performs electrical energy measurement and uses ADCs and reference circuitry for the analog portion of the device. Its multiplication and filtering are performed in the digital domain. The ADE7755ARSZRL is ordered as a tape-and-reel version, as identified by DigiKey, Mouser, and Arrow distributor listings.
What does the ADE7755ARSZRL measure?
The ADE7755ARSZRL measures electrical energy for single-phase metering systems using voltage and current sensing inputs. Analog Devices describes it as a high-accuracy electrical energy measurement IC, with signal processing including multiplication and filtering carried out in the digital domain. The supplied distributor information identifies a pulse output, allowing the meter system to count energy events. Exact input ranges, accuracy grades, and calibration constants must be confirmed in the ADE7755 manufacturer datasheet.
Is the ADE7755ARSZRL suitable for residential energy meters?
Yes, the ADE7755ARSZRL is suitable for residential single-phase energy meters because it is specifically identified as a single-phase meter IC with pulse output. Its digital-domain multiplication and filtering support structured energy calculation, while the analog section is limited to ADC and reference circuitry according to the Analog Devices product page. The final meter accuracy also depends on the current-sensor network, voltage divider, filtering, reference quality, firmware, and calibration.
What package does the ADE7755ARSZRL use?
The ADE7755ARSZRL is supplied in a 24-pin SSOP package and is listed as a tape-and-reel part by DigiKey and Arrow. The 24-pin package is a surface-mount package intended for compact metering electronics. Exact pin numbers, pin names, exposed-pad details, and recommended PCB land patterns must be taken from the official ADE7755 datasheet rather than inferred from the distributor package description.
Where can I download the ADE7755ARSZRL datasheet?
The official ADE7755 product information is available on Analog Devices at https://www.analog.com/en/products/ade7755.html, and the verified search results also link to an ADE7755ARSZRL PDF at https://www.alldatasheet.com/datasheet-pdf/pdf/562349/AD/ADE7755ARSZRL.html. Use the Analog Devices page as the authoritative starting point. The third-party PDF page is useful for locating a document, but engineers should verify revisions, package-specific details, and ordering information against the manufacturer source.
Where can I find the ADE7755ARSZRL pinout?
The ADE7755ARSZRL pinout is found in the manufacturer ADE7755 datasheet and should be cross-checked against the 24-pin SSOP package. The distributor record confirms the 24-SSOP package but does not provide a reliable pin-number table. Because incorrect power, reference, input, clock, or pulse-output assignments can damage a meter design, do not rely on unverified pinout images when laying out the PCB.
What are the key specifications of ADE7755ARSZRL engineers should know?
The verified facts are that ADE7755ARSZRL is a single-phase energy-metering IC with a pulse output in a 24-pin SSOP package, and Analog Devices says its accuracy surpasses the requirements quoted in IEC 1036. The device performs multiplication and filtering in the digital domain. Numeric supply voltage, ADC resolution, input range, accuracy, temperature limits, and calibration details were not included in the supplied results and remain marked as data-needed in this record.
What is the difference between ADE7755ARSZRL and a generic energy-metering IC?
ADE7755ARSZRL is a specific Analog Devices single-phase metering solution with a documented pulse output and digital-domain multiplication and filtering. A generic energy-metering IC may use a different measurement architecture, interface, accuracy class, or package, so the term alone is not enough to establish compatibility. For a real replacement, compare the manufacturer pinout, supply requirements, analog inputs, reference design, calibration method, and communication options rather than comparing only the product category.
Can the ADE7755ARSZRL be used in industrial energy monitoring?
Yes, the ADE7755ARSZRL can be considered for industrial single-phase energy monitoring when the input range, accuracy, temperature rating, and calibration requirements meet the application. The verified Analog Devices description establishes high-accuracy energy measurement and digital signal processing, but it does not provide the complete industrial operating envelope. Confirm supply voltage, input limits, safety isolation, environmental ratings, and meter certification requirements before production release.
How is the ADE7755ARSZRL pulse output used?
The ADE7755ARSZRL pulse output is used as an energy indication for a meter or counter circuit. In a typical system, each output pulse represents a defined amount of accumulated energy, allowing an external counter, microcontroller, display driver, or communications module to record consumption. The exact pulse frequency, pulse width, electrical levels, isolation requirements, and calibration convention must be taken from the official datasheet and system design reference.
What can replace the ADE7755ARSZRL?
A true drop-in replacement must have the same 24-pin SSOP footprint, pin-to-pin signal assignments, compatible supply and analog-input requirements, suitable metrology performance, and equivalent calibration or pulse-output behavior. The supplied cross-reference search did not identify a verified same-package replacement for the ADE7755ARSZRL, so no substitute is claimed here. The listed STTH802B-TR result is a diode, not an energy-metering IC, and must not be treated as a replacement.
Is STTH802B-TR a replacement for ADE7755ARSZRL?
No. The cross-reference search displayed STTH802B-TR as a suggested alternative for ADE7755ARSZ, but STTH802B-TR is identified as a STMicroelectronics diode and does not provide the metering functions, 24-pin interface, analog inputs, or pulse-output behavior of the ADE7755ARSZRL. It is not a drop-in replacement and must not be installed in the same meter PCB. This illustrates why cross-reference search results require datasheet and package verification.
What is the best Analog Devices alternative for ADE7755ARSZRL?
No verified Analog Devices drop-in alternative for the ADE7755ARSZRL was provided in the supplied cross-reference results. An acceptable replacement would need to match the 24-pin SSOP footprint and preserve the metrology, reference, input, clock, and pulse-output functions, but those conditions cannot be established from the search snippets alone. A redesign or functionally similar energy-metering IC may be possible, yet it should be treated as a different solution until the manufacturer pinout and electrical specifications are verified.
How should the ADE7755ARSZRL PCB be designed?
Design the ADE7755ARSZRL PCB around the manufacturer reference circuit and pinout, keeping the voltage and current sensing paths short, controlled, and away from noisy switching nodes. Pay particular attention to reference grounding, input filtering, resistor matching, clock integrity, calibration access, and the pulse-output route. The verified data confirms a 24-SSOP package and digital-domain processing, but it does not provide layout values, so capacitor, resistor, creepage, and placement requirements must be taken from the datasheet.
How accurate is the ADE7755ARSZRL?
Analog Devices states that the ADE7755 part specifications surpass the accuracy requirements quoted in IEC 1036. That statement describes the device family and manufacturer positioning, but it is not a substitute for the exact ADE7755ARSZRL accuracy limits, test conditions, input frequency range, or calibration grade. Those details were not supplied in the verified results and must be confirmed in the official datasheet before using the device in a regulated or production energy meter.

Engineering reference data for ADE7755ARSZRL — comparison, design guidance, and compliance information.

Selection Guide

Choose the ADE7755ARSZRL when designing a single-phase energy meter or monitoring node that needs a dedicated metering IC, digital-domain signal processing, and a pulse output. It is especially relevant when the system must preserve the ADE7755 family’s measurement architecture and reference design. Before committing, confirm the supply range, ADC and input limits, accuracy conditions, temperature range, communication requirements, and calibration procedure in the official datasheet.

Do not select a generic energy-metering IC solely because it has a similar description. A valid replacement must match the 24-pin SSOP footprint, pin assignments, electrical operating envelope, metrology behavior, and pulse-output function. The supplied search data contains no verified drop-in substitute, so the absence of alternatives is intentional. STTH802B-TR is explicitly excluded because it is a diode and not a functional or pin-compatible replacement. If the ADE7755ARSZRL is unavailable, evaluate a redesign around a different metering platform only after confirming system accuracy, isolation, communications, certification, and calibration requirements.

Comparison with Alternatives

Parameter This Product
Package 24-pin SSOP
Brand Analog Devices
Product Type Single-phase energy-metering IC
Pulse Output Yes
Measurement Channels Single-phase
Signal Processing Digital-domain multiplication and filtering
Manufacturer Reference Standard IEC 1036 accuracy context

Key Differentiators

  • Dedicated single-phase energy-metering function (vs Generic energy-metering IC)
  • Digital-domain multiplication and filtering (vs Analog-domain multiplier implementation)
  • Pulse-output integration (vs Non-pulse energy-metering front end)
  • 24-pin SSOP packaging (vs Larger or differently pinned metering package)

Design Notes

Keep the voltage and current sensing paths short and route them away from switching power stages, relay contacts, high-current conductors, and digital clock edges. The verified Analog Devices description indicates that the analog circuitry is concentrated in the ADCs and reference circuit, so minimizing board-level coupling around those nodes is especially important. Use the manufacturer reference layout for component placement and grounding; the supplied data does not provide exact trace widths, filter values, or spacing rules.

Do not assume that a generic energy-metering IC is a substitute for the ADE7755ARSZRL. The supplied cross-reference result showing STTH802B-TR is a diode, not a metering IC, and is therefore not pin-compatible or functionally equivalent. Before replacing this device, verify the 24-pin SSOP footprint, power pins, analog inputs, reference connection, clock requirements, pulse output, calibration method, and manufacturer-specific metrology limits.

Use the official ADE7755 datasheet reference circuit as the basis for the PCB layout, especially for the reference node, ADC inputs, current-sense path, supply decoupling, and pulse output. Account for component tolerances and temperature drift during calibration rather than relying only on nominal resistor values. The verified data confirms a tape-and-reel 24-pin SSOP package but does not provide land-pattern or capacitance guidance, so those values must not be invented.

Estimate self-heating from the actual supply voltage, quiescent current, output-drive load, and ambient temperature after those values are obtained from the official datasheet. Energy-metering ICs can be placed near power-conversion and sensor circuitry, where airflow and copper heat spreading vary substantially. Keep the device within its rated operating-temperature range and verify junction temperature with the final enclosure, trace loading, and measured supply conditions.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

Analog Devices states that the ADE7755 performance surpasses the accuracy requirements quoted in IEC 1036. RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-mineral status were not included in the verified web data and are therefore recorded as unknown.

Related Searches

ADE7755ARSZRL ADE7755ARSZRL datasheet Analog Devices ADE7755ARSZRL ADE7755 single-phase energy metering IC ADE7755ARSZRL 24-SSOP ADE7755 pulse output energy meter ADE7755ARSZRL replacement ADE7755ARSZRL buy online ADE7755ARSZRL price ADE7755ARSZRL pinout single-phase smart meter IC energy metering IC with pulse output ADE7755 IEC 1036 accuracy ADE7755ARSZRL cross reference 24-pin SSOP energy meter IC

Related Components & Terms

Analog Devices ADE7755ARSZRL ADE7755 single-phase energy-metering IC electrical energy measurement pulse output 24-pin SSOP tape-and-reel packaging ADC reference circuit digital-domain multiplication digital-domain filtering IEC 1036 single-phase meter smart meter industrial energy monitoring smart-grid sensor node residential energy monitor current sensing voltage sensing calibration RS-485 isolation interface microcontroller
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details