ADE7755ARSZRL - Single-Phase Energy Meter IC | Analog Devices
部品番号: ADE7755ARSZRL ✗ 生産終了| 数量 | 単価 | 小計 |
|---|---|---|
| 1 | $0 | $0.00 |
| 10 | $0 | $0.00 |
| 100 | $0 | $0.00 |
| 500 | $0 | $0.00 |
| 1,000 | $0 | $0.00 |
ADE7755ARSZRL 概要
An energy-metering IC is a specialized data-acquisition and power-management semiconductor used to measure voltage and current, calculate electrical energy, and provide a pulse or digital indication to the host system. The ADE7755 places its multiplication and filtering functions in the digital domain, while the only analog circuitry is associated with the ADCs and reference circuit. This architecture is intended to improve measurement stability and reduce sensitivity to analog component variation.
The ADE7755 is suited to single-phase utility meters, residential energy monitors, load-management equipment, industrial energy measurement, and smart-grid sensing nodes. Its pulse output provides a convenient interface for meter calibration, energy accumulation, or host-system counting. The ADE7755 is available in the ADE7755ARSZRL ordering code, identified in distributor results as a 24-SSOP tape-and-reel part.
The 24-pin SSOP package provides the physical interface for analog inputs, digital control, communication, and pulse-output functions. Designers should follow the manufacturer datasheet for exact pin assignments, recommended current and voltage sensing circuits, calibration procedures, filtering values, and electrical limits. The verified distributor descriptions identify the ADE7755 as a single-phase meter IC with pulse output and do not provide a complete set of numeric operating specifications in the supplied search results.
A key design consideration is maintaining the integrity of the voltage and current sensing path. Input filtering, resistor matching, reference stability, clock selection, PCB isolation, and calibration determine whether the meter's achieved accuracy matches its calculation capability. In a production design, evaluate the complete analog front end rather than relying on IC specifications alone.
This page synthesizes the verified manufacturer product description, distributor availability information, package identification, and engineering-oriented application guidance. It distinguishes documented facts from parameters that require confirmation in the manufacturer datasheet, helping engineers evaluate whether the ADE7755ARSZRL is appropriate for a new metering design.
ドロップイン代替品: ADE7755ARSZRL — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
クイック比較ツール — 並列比較する代替部品を選択:
この製品に利用可能なドロップイン代替品はありません。
代替品をリクエストADE7755ARSZRL 最大定格&電気的特性
| Product Type | Single-phase energy metering IC |
| Output Interface | Pulse output |
| パッケージ | 24-pin SSOP |
| 実装タイプ | Surface mount |
| Tape-and-Reel Packaging | Yes |
| Manufacturer Reference Standard | IEC 1036 |
| Signal Processing | Digital-domain multiplication and filtering |
| Analog Circuitry | ADC and reference circuitry |
ADE7755ARSZRL 24-pin ssop ピン配置ガイド
ADE7755ARSZRL (24-pin ssop パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: ADE7755ARSZRL.
詳細は データシート をご参照ください。
主な用途
ADE7755ARSZRL の用途: 6 件s: Residential Single-Phase Smart Meter, Utility Load-Monitoring Terminal, Residential Energy Monitor, Smart-Grid Sensor Node, Industrial Equipment Energy Meter, Calibration and Test Equipment.
Residential Single-Phase Smart Meter
The ADE7755ARSZRL is suited to a residential single-phase smart meter because the verified distributor information identifies it as a single-phase meter IC with pulse output. It can measure the electrical quantities needed for energy accumulation while the host system counts pulse events or applies additional digital processing. The device’s digital-domain multiplication and filtering can simplify the measurement architecture, but final accuracy still depends on the current-sensor network, voltage divider, reference quality, and calibration. Confirm the official ADE7755 pinout, input limits, supply requirements, and metrology conditions before laying out the meter PCB.
おすすめ
Utility Load-Monitoring Terminal
For utility load-monitoring terminals, the ADE7755ARSZRL provides the metering core for a single-phase energy measurement path and a pulse output that can be counted or forwarded by surrounding electronics. Its digital processing approach can reduce dependence on analog multiplier stability, while the analog front end remains concentrated around the ADCs and reference circuit as described by Analog Devices. A practical design must still address surge, conducted noise, grounding, sensor isolation, and calibration drift. The verified source does not specify terminal communication interfaces or operating limits, so those details require datasheet confirmation.
おすすめ
Residential Energy Monitor
The ADE7755ARSZRL can form the measurement front end of a residential energy monitor that displays or transmits consumption data. Its pulse output provides a straightforward energy-counting interface, while the ADE7755 family’s digital-domain multiplication and filtering supports consistent calculation across operating conditions. For accurate results, use the manufacturer’s recommended current and voltage sensing networks and account for component tolerance and temperature effects. The verified sources do not provide display-interface specifications, so a host microcontroller or display controller must be selected separately.
おすすめ
Smart-Grid Sensor Node
In a smart-grid sensor node, the ADE7755ARSZRL can serve as the single-phase energy-measurement device feeding a communications and data-processing subsystem. The manufacturer describes the ADE7755 as a high-accuracy electrical energy measurement IC and states that its performance surpasses the accuracy requirements quoted in IEC 1036. That makes the part relevant to energy monitoring nodes, although compliance and accuracy claims must be checked against the exact test conditions. Designers should also evaluate network isolation, electromagnetic robustness, enclosure temperature, and the regulatory requirements of the deployed grid equipment.
おすすめ
Industrial Equipment Energy Meter
ADE7755ARSZRL can be evaluated for industrial equipment energy metering where a single-phase load must be measured and accumulated. The pulse output allows the result to be integrated into a counter or supervisory controller, while the digital processing architecture can simplify the measurement chain after the analog front end. Industrial use requires careful review of operating-temperature limits, supply regulation, input transients, isolation, enclosure grounding, and calibration stability; those numeric limits are not present in the supplied verified data. The device should therefore be selected only after checking the full manufacturer datasheet and completing system-level accuracy tests.
おすすめ
Calibration and Test Equipment
The ADE7755ARSZRL pulse output can be useful in calibration and test equipment that verifies energy accumulation behavior or compares a meter channel against a reference source. The single-phase architecture and pulse indication make it possible to observe energy events externally without depending on undocumented internal calculations. A useful test fixture must provide controlled voltage and current excitation, accurate timing, appropriate load timing, and an independent energy reference. The verified information does not state pulse-width, maximum-frequency, or test-current limits, so the fixture must be designed from the official ADE7755 datasheet and application guidance.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: ADE7755ARSZRL — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
Do not select a generic energy-metering IC solely because it has a similar description. A valid replacement must match the 24-pin SSOP footprint, pin assignments, electrical operating envelope, metrology behavior, and pulse-output function. The supplied search data contains no verified drop-in substitute, so the absence of alternatives is intentional. STTH802B-TR is explicitly excluded because it is a diode and not a functional or pin-compatible replacement. If the ADE7755ARSZRL is unavailable, evaluate a redesign around a different metering platform only after confirming system accuracy, isolation, communications, certification, and calibration requirements.
代替品との比較
| パラメータ | この製品 |
|---|---|
| Package | 24-pin SSOP |
| Brand | Analog Devices |
| Product Type | Single-phase energy-metering IC |
| Pulse Output | Yes |
| Measurement Channels | Single-phase |
| Signal Processing | Digital-domain multiplication and filtering |
| Manufacturer Reference Standard | IEC 1036 accuracy context |
主な差別化要因
- Dedicated single-phase energy-metering function (vs Generic energy-metering IC)
- Digital-domain multiplication and filtering (vs Analog-domain multiplier implementation)
- Pulse-output integration (vs Non-pulse energy-metering front end)
- 24-pin SSOP packaging (vs Larger or differently pinned metering package)
設計ノート
Keep the voltage and current sensing paths short and route them away from switching power stages, relay contacts, high-current conductors, and digital clock edges. The verified Analog Devices description indicates that the analog circuitry is concentrated in the ADCs and reference circuit, so minimizing board-level coupling around those nodes is especially important. Use the manufacturer reference layout for component placement and grounding; the supplied data does not provide exact trace widths, filter values, or spacing rules.
Do not assume that a generic energy-metering IC is a substitute for the ADE7755ARSZRL. The supplied cross-reference result showing STTH802B-TR is a diode, not a metering IC, and is therefore not pin-compatible or functionally equivalent. Before replacing this device, verify the 24-pin SSOP footprint, power pins, analog inputs, reference connection, clock requirements, pulse output, calibration method, and manufacturer-specific metrology limits.
Use the official ADE7755 datasheet reference circuit as the basis for the PCB layout, especially for the reference node, ADC inputs, current-sense path, supply decoupling, and pulse output. Account for component tolerances and temperature drift during calibration rather than relying only on nominal resistor values. The verified data confirms a tape-and-reel 24-pin SSOP package but does not provide land-pattern or capacitance guidance, so those values must not be invented.
Estimate self-heating from the actual supply voltage, quiescent current, output-drive load, and ambient temperature after those values are obtained from the official datasheet. Energy-metering ICs can be placed near power-conversion and sensor circuitry, where airflow and copper heat spreading vary substantially. Keep the device within its rated operating-temperature range and verify junction temperature with the final enclosure, trace loading, and measured supply conditions.
コンプライアンス情報
Analog Devices states that the ADE7755 performance surpasses the accuracy requirements quoted in IEC 1036. RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-mineral status were not included in the verified web data and are therefore recorded as unknown.