ADM2582EBRWZ - Isolated RS-485 Transceiver | Analog Devices
MPN: ADM2582EBRWZ ✓ Active| Qty | Unit Price | Extended |
|---|---|---|
| 1 | $8.5 | $8.50 |
| 10 | $7.65 | $76.50 |
| 100 | $6.8 | $680.00 |
| 500 | $6.12 | $3,060.00 |
| 1,000 | $5.5 | $5,500.00 |
Drop-in alternatives for ADM2582EBRWZ — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Quick Comparison Tool — Select alternative parts for side-by-side comparison:
ADM2587EBRWZ
✅ Drop-In✓ In Stock
$4.62 / Unit
View Datasheet →ADM2582EBRWZ-REEL7
✅ Drop-In📋 Reference alternative (not in catalog)
ADM2587EBRWZ-REEL7
✅ Drop-In✓ In Stock
$3.44 / Unit
View Datasheet →ADM2483BRWZ
✅ Drop-In✓ In Stock
$3.75 / Unit
View Datasheet →ADM2483BRWZ-RL7
✅ Drop-In✓ In Stock
$4.16 / Unit
View Datasheet →ISO3082DW
✅ Drop-In📋 Reference alternative (not in catalog)
ADM2582EBRWZ Maximum Ratings & Electrical Characteristics
| Isolation Voltage | 2500 Vrms |
| Data Rate | 16 Mbps |
| Common-Mode Transient Immunity | 25 kV/µs |
| ESD Protection | ±15 kV (HBM) |
| Number of Channels | 2 |
| Supply Voltage | 3.3 V to 5 V |
| Duplex | Full/Half |
| Number of Nodes | 64 |
| Package | 20-SOIC (0.295", 7.50mm Width) |
| Operating Temperature | -40°C to +85°C |
| Propagation Delay | 50 ns (typical) |
| Skew | 5 ns (typical) |
| Isolation Technology | isoPower, iCoupler |
| RoHS Status | Compliant |
| Mounting Type | Surface Mount |
ADM2582EBRWZ Pin Configuration
| Pin 1 | VCC — Logic supply voltage (3.3V or 5V) |
| Pin 2 | GND — Logic ground |
| Pin 3 | TXD — Transmit data input |
| Pin 4 | RXD — Receive data output |
| Pin 5 | DE — Driver enable (active high) |
| Pin 6 | RE — Receiver enable (active low) |
| Pin 7 | A — Non-inverting bus line |
| Pin 8 | B — Inverting bus line |
| Pin 9 | GND — Isolated ground |
| Pin 10 | VISO — Isolated supply output |
| Pin 11 | VISO — Isolated supply output |
| Pin 12 | GND — Isolated ground |
| Pin 13 | B — Inverting bus line |
| Pin 14 | A — Non-inverting bus line |
| Pin 15 | RE — Receiver enable (active low) |
| Pin 16 | DE — Driver enable (active high) |
| Pin 17 | RXD — Receive data output |
| Pin 18 | TXD — Transmit data input |
| Pin 19 | GND — Logic ground |
| Pin 20 | VCC — Logic supply voltage (3.3V or 5V) |
Safe Operating Area (SOA) & Thermal Characteristics
No official SOA curve available for this digital IC. Always operate within absolute maximum ratings specified in the datasheet. Ensure adequate cooling and derate as needed.
Typical Applications
ADM2582EBRWZ is suitable for 6 applications: Industrial Fieldbus Networks, Motor Control Systems, Building Automation, Solar Inverters, Medical Equipment, Transportation Systems.
Industrial Fieldbus Networks
The ADM2582EBRWZ is ideal for industrial fieldbus networks such as PROFIBUS and Modbus, where reliable, isolated RS-485 communication is required over long distances. Its 16 Mbps data rate and 25 kV/µs CMTI ensure robust data transmission in noisy factory environments. The integrated isoPower eliminates the need for an external isolated supply, simplifying design and reducing board space. With ±15 kV ESD protection, it withstands harsh conditions. The device supports up to 64 nodes, enabling large multi-drop networks. Its wide operating temperature range (-40°C to +85°C) suits industrial settings.
Recommended
Motor Control Systems
In motor control systems, the ADM2582EBRWZ provides galvanic isolation between the controller and the motor drive, protecting against ground loops and voltage transients. Its high CMTI of 25 kV/µs prevents data corruption from fast switching noise. The integrated power isolation reduces component count and simplifies PCB layout. The device supports full-duplex communication, enabling simultaneous read/write operations for real-time control. With ±15 kV ESD protection, it withstands electrostatic discharges common in industrial environments. The 16 Mbps data rate allows high-speed feedback loops.
Recommended
Building Automation
The ADM2582EBRWZ is well-suited for building automation systems, including HVAC controls and lighting systems, where RS-485 networks connect sensors and actuators over long cable runs. Its 2.5 kVrms isolation protects against ground potential differences between floors or buildings. The integrated isoPower eliminates the need for separate isolated supplies, reducing installation complexity. The device's 16 Mbps data rate supports fast polling of multiple nodes. Its wide temperature range and ESD protection ensure reliable operation in building environments. The full/half-duplex configurability allows flexible network topologies.
Recommended
Solar Inverters
In solar inverter systems, the ADM2582EBRWZ provides isolated communication between the inverter controller and monitoring systems. The 2.5 kVrms isolation protects against high-voltage transients from the solar panels. The integrated isoPower simplifies the power supply design, as it generates the isolated bus-side supply from the 3.3V or 5V input. The device's high CMTI ensures reliable data transmission in the presence of switching noise from the inverter. With ±15 kV ESD protection, it withstands harsh outdoor conditions. The 16 Mbps data rate supports fast data logging and remote monitoring.
Recommended
Medical Equipment
The ADM2582EBRWZ is used in medical equipment for isolated communication between patient monitoring devices and central systems. Its 2.5 kVrms isolation ensures patient safety by preventing dangerous voltages from reaching the patient. The integrated isoPower reduces the risk of ground loops and simplifies the power supply design. The device's low propagation delay and high data rate enable real-time data transmission. With ±15 kV ESD protection, it meets the reliability requirements of medical environments. The wide temperature range ensures operation in various clinical settings.
Recommended
Transportation Systems
In transportation systems, such as railway and automotive applications, the ADM2582EBRWZ provides isolated RS-485 communication for control and monitoring. Its 2.5 kVrms isolation protects against voltage spikes from traction systems. The integrated isoPower eliminates the need for an external isolated supply, reducing weight and space. The device's high CMTI ensures reliable communication in the presence of electromagnetic interference. With ±15 kV ESD protection, it withstands harsh environmental conditions. The 16 Mbps data rate supports high-speed data exchange between subsystems.
Recommended
Recommended Products Summary
Engineering reference data for ADM2582EBRWZ — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | ADM2587EBRWZ | ADM2483BRWZ | ISO3082DW |
|---|---|---|---|---|
| Package | 20-SOIC (0.295", 7.50mm Width) | 20-SOIC (0.295", 7.50mm Width) - same | 20-SOIC (0.295", 7.50mm Width) - same | 20-SOIC (0.295", 7.50mm Width) - same |
| Brand | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Isolation Voltage | 2500 Vrms | 2500 Vrms | 2500 Vrms | 2500 Vrms |
| Data Rate | 16 Mbps | 16 Mbps | 500 kbps | 20 Mbps |
| ESD Protection | ±15 kV | ±15 kV | ±15 kV | ±16 kV |
| CMTI | 25 kV/µs | 25 kV/µs | 25 kV/µs | 50 kV/µs |
| Supply Voltage | 3.3V to 5V | 3.3V to 5V | 3.3V to 5V | 3.3V to 5V |
| Integrated Power | Yes (isoPower) | Yes (isoPower) | Yes (isoPower) | No (requires external isolated supply) |
Key Differentiators
- Integrated isoPower eliminates external isolated supply (vs ISO3082DW)
- Higher data rate than ADM2483BRWZ (vs ADM2483BRWZ)
- Same package and pinout as ADM2587EBRWZ (vs ADM2587EBRWZ)
Design Notes
For the ADM2582EBRWZ, ensure proper PCB layout with adequate spacing between the logic side and the isolated side to maintain the 2.5 kVrms isolation rating. Use a solid ground plane on each side and avoid routing traces across the isolation barrier. Place decoupling capacitors (0.1 µF and 10 µF) close to the VCC and VISO pins. The isoPower converter requires an external transformer (e.g., Wurth Elektronik 750313771) and a rectifier diode, as specified in the datasheet. Follow the recommended layout in the datasheet to minimize EMI.
The ADM2582EBRWZ dissipates power due to the integrated isoPower converter. At maximum data rate and load, the power dissipation can be significant. Ensure adequate thermal management by providing copper pour on the PCB and ensuring airflow. The thermal resistance from junction to ambient (θJA) is approximately 80°C/W for the SOIC-20 package. Calculate the junction temperature to ensure it stays below the maximum rating of 150°C. For high ambient temperatures, consider derating the data rate or adding a heatsink.
A common pitfall is neglecting the external transformer for the isoPower converter. The ADM2582E requires an external transformer and rectifier diode to generate the isolated supply. Using an incorrect transformer can lead to insufficient power or excessive EMI. Also, ensure that the bus termination resistors (120 Ω) are placed at both ends of the RS-485 bus to prevent reflections. Do not exceed the absolute maximum ratings for VCC and VISO. Additionally, the RE and DE pins must be properly controlled to avoid bus contention.
Compliance Information
RoHS compliant per Analog Devices product page. Not AEC-Q100 qualified. Halogen-free status not specified in available data.