ADM3063EBRMZ-RL7 Maximum Ratings & Electrical Characteristics
| Supply Voltage Range | 3.0 V to 5.5 V |
| Data Rate | 500 kbps |
| Duplex | Full |
| Number of Drivers/Receivers | 1/1 |
| ESD Protection (Bus Pins) | ±12 kV IEC 61000-4-2 contact discharge |
| Fail-Safe | Full receiver short-circuit, open circuit, and bus idle fail-safe |
| Hot Swap Support | Yes (glitch-free power-up/power-down) |
| PROFIBUS Compliance | Yes at VCC ≥ 4.5 V |
| Operating Temperature Range | -40°C to +125°C |
| Package | 10-lead MSOP (RM) |
| Mounting Style | SMD/SMT |
| RoHS | Compliant |
| Common-Mode Input Range | [DATA_NEEDED: Common-mode input range] |
| Receiver Input Impedance | [DATA_NEEDED: Receiver input impedance] |
| Propagation Delay | [DATA_NEEDED: Propagation delay] |
ADM3063EBRMZ-RL7 Pin Configuration
| Pin 1 | RO — Receiver output |
| Pin 2 | RE — Receiver enable (active low) |
| Pin 3 | DE — Driver enable (active high) |
| Pin 4 | DI — Driver input |
| Pin 5 | GND — Ground |
| Pin 6 | A — Non-inverting bus pin |
| Pin 7 | B — Inverting bus pin |
| Pin 8 | Y — Driver output (non-inverting) |
| Pin 9 | Z — Driver output (inverting) |
| Pin 10 | VCC — Power supply |
Safe Operating Area (SOA) & Thermal Characteristics
No official SOA curve available for this digital IC. Always operate within absolute maximum ratings specified in the datasheet. Ensure adequate cooling and derate as needed.
Typical Applications
ADM3063EBRMZ-RL7 is suitable for 6 applications: Industrial Automation, Building Automation, Instrumentation, Networking Equipment, Security Systems, Transportation.
Industrial Automation
The ADM3063EBRMZ-RL7 is ideal for industrial automation networks, such as PLC-to-sensor communication, due to its robust ±12 kV IEC ESD protection and extended temperature range. Its 500 kbps data rate supports reliable data transmission over long cable runs, while full-duplex operation enables simultaneous read/write in point-to-point links. The device's PROFIBUS compliance at VCC ≥ 4.5 V ensures compatibility with standard industrial fieldbus protocols, making it a drop-in solution for factory floor control systems.
Recommended
Building Automation
In building automation, the ADM3063EBRMZ-RL7 is used in HVAC controllers and lighting systems to communicate over RS-485 buses. Its low-speed 500 kbps data rate is well-suited for the moderate distances and data rates typical in building networks. The full fail-safe feature ensures that the receiver outputs a known state when the bus is idle, open, or shorted, preventing false commands to actuators. The wide supply range (3.0 V to 5.5 V) allows direct interfacing with both 3.3 V and 5 V microcontrollers, simplifying system design.
Recommended
Instrumentation
The ADM3063EBRMZ-RL7 is well-suited for instrumentation systems, such as data loggers and test equipment, where reliable data transfer over long distances is required. Its full-duplex capability allows simultaneous data acquisition and control, improving system throughput. The ±12 kV IEC ESD protection ensures the device can withstand electrostatic discharges common in laboratory and field environments. The compact MSOP package is ideal for portable instruments where PCB space is limited.
Recommended
Networking Equipment
The ADM3063EBRMZ-RL7 can be used in networking equipment, such as serial servers and protocol converters, to provide RS-485 connectivity. Its 500 kbps data rate is sufficient for many industrial networking protocols, and the full-duplex operation enables efficient bidirectional communication. The device's hot swap support allows for glitch-free insertion and removal of modules in live systems, which is critical in redundant network architectures. The wide temperature range ensures reliable operation in equipment racks with elevated temperatures.
Recommended
Security Systems
In security systems, the ADM3063EBRMZ-RL7 is used in access control panels and surveillance cameras to communicate over RS-485 buses. Its robust ESD protection is essential in outdoor installations where electrostatic discharges are common. The fail-safe feature ensures that the system does not trigger false alarms when the bus is disconnected or shorted. The low-speed data rate is adequate for transmitting control commands and status updates, while the full-duplex operation allows simultaneous video and control data in some architectures.
Recommended
Transportation
The ADM3063EBRMZ-RL7 is suitable for transportation systems, such as railway signaling and traffic control, where reliable communication over long distances is critical. Its extended temperature range (-40°C to +125°C) and ±12 kV ESD protection make it robust for outdoor installations. The device's PROFIBUS compliance is beneficial in railway applications that use PROFIBUS for train control. The full-duplex operation enables simultaneous data exchange between control centers and field devices, improving system responsiveness.
Recommended
Recommended Products Summary
Engineering reference data for ADM3063EBRMZ-RL7 — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | ADM3063EBRMZ | ADM3063EBRMZ-R7 | ADM3063EBRZ-R7 | ADM3063EBRZ |
|---|---|---|---|---|---|
| Package | 10-lead MSOP | 10-lead MSOP | 10-lead MSOP | 14-lead SOIC | 14-lead SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Data Rate | 500 kbps | 500 kbps | 500 kbps | 500 kbps | 500 kbps |
| Duplex | Full | Full | Full | Full | Full |
| ESD Protection | ±12 kV IEC | ±12 kV IEC | ±12 kV IEC | ±12 kV IEC | ±12 kV IEC |
| Supply Voltage | 3.0 V to 5.5 V | 3.0 V to 5.5 V | 3.0 V to 5.5 V | 3.0 V to 5.5 V | 3.0 V to 5.5 V |
| Operating Temperature | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C |
| Fail-Safe | Full | Full | Full | Full | Full |
Key Differentiators
- Full-duplex operation in a compact MSOP package (vs ADM3485EARZ)
- ±12 kV IEC ESD protection (vs MAX3485ESA)
- PROFIBUS compliance at VCC ≥ 4.5 V (vs ADM3485EARZ)
Design Notes
For optimal performance, place the ADM3063EBRMZ-RL7 close to the bus connector and keep the differential traces (A, B, Y, Z) as short as possible. Use 120 Ω termination resistors at both ends of the bus to minimize reflections. Ensure a solid ground plane and decouple the VCC pin with a 0.1 µF ceramic capacitor placed as close to the pin as possible.
Avoid exceeding the absolute maximum ratings, particularly the supply voltage and bus pin voltages. The device is ESD protected, but proper handling procedures should still be followed. Ensure that the receiver enable (RE) and driver enable (DE) pins are not left floating; tie them to appropriate logic levels to prevent unintended bus contention.
The ADM3063EBRMZ-RL7 has low power dissipation, but in high-temperature environments, ensure adequate airflow or thermal relief. The MSOP package has a moderate thermal resistance; for high ambient temperatures, consider derating the output drive or using a larger package variant if thermal issues arise.
Compliance Information
RoHS compliant per Analog Devices product page. AEC-Q100 not applicable for this industrial-grade device.