ADS1210U/1K Overview

The Texas Instruments ADS1210U/1K is a 24-bit, single-channel sigma-delta analog-to-digital converter designed for high-resolution measurement systems. The device accepts differential analog inputs, includes a programmable gain amplifier, and supports SPI-compatible synchronous serial communication. It is identified in the manufacturer and distributor information as an 18-pin SOIC package, making it suitable for compact precision-instrumentation designs.

An analog-to-digital converter is an interface IC that converts continuous analog voltage signals into digital data for processing by a microcontroller, PLC, or measurement controller. Sigma-delta ADCs belong to the ADC category, use an oversampling and digital-filtering architecture, and are commonly selected when high resolution and effective noise performance matter more than very high conversion speed. The ADS1210U/1K is therefore positioned for low-level sensor and transducer measurements rather than high-bandwidth waveform acquisition.

The ADS1210 family is intended for applications such as industrial process control, smart transmitters, weigh scales, chromatography, and portable instrumentation. Its differential input architecture helps reject common-mode noise when the measured source is referenced to an analog ground. The integrated programmable gain amplifier allows the front end to accommodate signals of different amplitudes while preserving useful resolution. The manufacturer describes the converter as offering a maximum data rate of 16 kSPS in the associated product information, making it appropriate for slow, high-accuracy measurements.

The serial interface provides a straightforward connection to embedded systems. SPI-compatible operation supports deterministic digital communication, while the family also offers two-wire control operation for isolated or cost-sensitive interfaces. System design should account for the analog input network, reference selection, bypass capacitors, digital interface timing, and the conversion-data latency associated with the digital filter. The ADS1210U/1K is a single-input device, so applications requiring multiple independent channels will need an additional converter or a multiplexing arrangement.

For low-level sensor connections, use a front-end network that limits overvoltage and ESD events, while keeping the differential signal path short and away from switching nodes. The reference and supply bypass capacitors should be placed close to their associated pins, and the ground-return arrangement should minimize voltage drops in the measurement path. Verify the selected gain, data rate, digital filter setting, and input common-mode range against the operating conditions of the transducer.

This product page consolidates the available technical identity, manufacturer application positioning, sourcing information, and practical integration guidance for the ADS1210U/1K. It also separates same-package alternatives from parts that require a footprint or interface review. When replacing an existing design, confirm the exact package, pin assignments, electrical limits, reference configuration, and interface mode in the manufacturer datasheet before approving the substitution.

Drop-in alternatives for ADS1210U/1K — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with ADS1210U/1K (same form factor and footprint) — differing in Package, Supply Voltage, Mounting Type, Applications, Digital Filter.

Texas Instruments
Package: 16-pin SOIC
Texas Instruments
Package: 8-SOIC
Supply Voltage: Single +5 V
Digital Filter: Programmable cutoff frequency
Texas Instruments
Supply Voltage: +5 V single supply
Mounting Type: Surface Mount (SOIC/SSOP) or Through-Hole (DIP)
Applications: Smart transmitters, industrial process control, weigh scales, chromatography, portable instrumentation

ADS1210U

✅ Drop-In
Texas Instruments
📦 18-pin SOIC
Delta-sigma analog-to-digital converter · 24 bit · 23 bit · 20 bit · 22 bit · Single +5 V · Differential inputs · Programmable gain amplifier

Contact for price

View Datasheet →

ADS1201U/1K

✅ Drop-In
Texas Instruments
📦 18-pin SOIC
24-bit high-dynamic-range delta-sigma modulator · 24 bit · 1 kSPS · Serial · 16-pin SOIC · Surface mount · 5 V · -40 °C to +85 °C

Contact for price

View Datasheet →

ADS1211

✅ Drop-In
Texas Instruments
📦 18-pin SOIC
24 bit · 23 bits at 10 Hz; 20 bits at 1000 Hz · 4 (with input multiplexer) · Differential · Delta-Sigma · +5 V single supply · 12 mW (typical) · SPI-compatible serial (SSI), 2-wire mode supported

Contact for price

View Datasheet →

ADS1210U/1K Maximum Ratings & Electrical Characteristics

ADC Resolution 24 bit
Number of Input Channels 1 channel
Architecture Delta-sigma
Input Type Differential
Maximum Data Rate 16 kSPS
Programmable Gain Amplifier Integrated
Digital Interface SPI-compatible synchronous serial interface; 2-wire control mode supported by the ADS1210 family
Supply Voltage 5 V
Reference Voltage 2.048 V
Package 18-pin SOIC
Package Family SOIC family
Mounting Type Surface mount
Terminal Count 18 terminals
Package Shape Rectangular
Lead Form Gull wing
Temperature Grade Industrial grade
Applications Smart transmitters, industrial process control, weigh scales, chromatography, and portable instrumentation

ADS1210U/1K rectangular Pin Configuration Guide

Pin configuration for ADS1210U/1K (rectangular package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.

rectangular package pinout diagram for ADS1210U/1K

No detailed pinout data available for ADS1210U/1K.

Refer to the datasheet for full pin configuration.

Typical Applications

ADS1210U/1K is suitable for 6 applications: Load-Cell Weigh Systems, Industrial Pressure Transmitters, Portable Instrumentation, Smart Transmitter Interfaces, Chromatography Data Acquisition, Precision Temperature Measurement.

⚖️

Load-Cell Weigh Systems

The ADS1210U/1K fits precision load-cell measurement because its 24-bit delta-sigma conversion, differential input, and integrated programmable gain amplifier suit the small bridge signals produced by strain gauges. The converter can operate from a single 5 V supply and provide a 16 kSPS maximum data rate. Place the bridge excitation and analog input routing away from switching converters and motors. Calibration should include bridge offset, gain, scale factor, and system nonlinearity, while the mechanical design must address vibration, creep, and lead-wire resistance.

🏭

Industrial Pressure Transmitters

The ADS1210U/1K is appropriate for industrial pressure and level transmitters that produce a low-level differential signal. Its integrated PGA reduces analog front-end complexity, while the differential input helps reject common-mode voltage present in long industrial wiring. The 24-bit nominal resolution and data rates up to 16 kSPS support accurate process readings without requiring a high-speed SAR ADC. Design the input stage with surge and ESD protection, verify the 5 V supply requirements, and isolate the measurement section when the transmitter interface requires it.

🔧

Portable Instrumentation

The ADS1210U/1K supports compact handheld or portable measurement equipment where a high-resolution reading is more important than rapid waveform capture. The single differential input, integrated PGA, and 18-pin SOIC package simplify board construction around sensors such as thermocouples, strain gauges, and resistive bridges. Low-level analog routing should remain compact, and the digital interface can connect to a microcontroller through the SPI-compatible mode. Battery-powered products should account for the converter's supply requirements and select data rates and filters that balance measurement latency against energy use.

🌐

Smart Transmitter Interfaces

The ADS1210U/1K is suitable for smart-transmitter interfaces that digitize a conditioned sensor signal before applying calibration and transmitting process data. Its 24-bit resolution preserves detail from low-level transducer outputs, while the integrated programmable gain amplifier allows one design to cover multiple sensor ranges. The manufacturer identifies smart transmitters as an intended application. Use differential input routing, local reference and supply bypassing, and a protected interface to maintain measurement integrity while the transmitter communicates with a host controller.

📊

Chromatography Data Acquisition

The ADS1210U/1K can be used in chromatography measurement systems when the sensor output requires high nominal resolution and the acquisition rate is relatively low. The differential input supports direct connection to suitable transducer front ends, while the integrated PGA reduces the need for separate gain amplification. Configure the data rate and digital filtering according to the required settling time and channel bandwidth. High-impedance sensor nodes and reference routing require careful PCB layout because leakage, stray capacitance, and ground disturbance can affect the acquired result.

🌡️

Precision Temperature Measurement

The ADS1210U/1K can digitize low-level temperature sensor signals when the front end provides a differential voltage suitable for the ADC's PGA. Its 24-bit resolution and differential architecture are useful for bridge-based temperature sensing and precision sensor interfaces. The design should account for thermocouple cold-junction compensation where applicable, sensor excitation stability, and EMI near the input pins. For faster sampling, selectable data rates up to 16 kSPS provide some flexibility, but system latency remains governed by the configured digital filter.

What are the key specifications of ADS1210U/1K that engineers should know?
The ADS1210U/1K is a 24-bit, single-channel, differential-input delta-sigma ADC with an integrated programmable gain amplifier, a maximum data rate of 16 kSPS, and an 18-pin SOIC package. According to the Texas Instruments ADS1210 family datasheet, the device is intended for precision measurements in smart transmitters, process control, weigh scales, chromatography, and portable instrumentation. Its key engineering benefits are high nominal resolution, flexible input gain, and an SPI-compatible synchronous serial interface.
Where can I download the ADS1210U/1K datasheet PDF?
The official Texas Instruments ADS1210 datasheet is available through the manufacturer datasheet link on this page at https://www.ti.com/lit/gpn/ADS1210. It is the preferred document for the device's electrical characteristics, register map, digital interface, application circuit, and pin descriptions. The ADS1210U/1K ordering suffix identifies the 18-pin SOIC version, so use the package-specific pin and ordering information when assigning PCB functions.
What is the operating voltage of ADS1210U/1K?
The ADS1210U/1K operates from a single 5 V supply. According to the Texas Instruments ADS1210 family datasheet, the device uses an internal 2.048 V reference, which provides a defined conversion reference for the delta-sigma measurement path. Verify supply tolerance, reference behavior, and analog input limits against the manufacturer specifications when designing the power architecture and protection network.
What resolution and conversion speed does ADS1210U/1K provide?
The ADS1210U/1K provides 24-bit resolution and supports data rates up to 16 kSPS. According to the Texas Instruments ADS1210 family datasheet, the delta-sigma architecture prioritizes high resolution for low-level measurement rather than high-bandwidth sampling. Actual usable throughput and noise depend on the configured data rate, digital filter, gain, reference, and input signal characteristics.
Where can I find the ADS1210U/1K pinout?
The ADS1210U/1K pinout is identified by the manufacturer as an 18-pin SOIC package. Use the pin-description table and package drawing in the Texas Instruments ADS1210 datasheet to assign analog inputs, supply, ground, reference, clock, and serial-interface signals. The product listings also provide pinout diagrams, but the manufacturer datasheet should control final PCB assignments and exposed routing requirements.
Is ADS1210U/1K suitable for load-cell and weigh-scale measurement?
Yes, ADS1210U/1K is suitable for load-cell and weigh-scale measurement because it combines 24-bit resolution, a differential input, and an integrated programmable gain amplifier. According to the Texas Instruments ADS1210 family datasheet, weigh scales are an intended application. The final signal-chain design should still evaluate bridge excitation, lead-wire resistance, input noise, filtering, calibration, and mechanical vibration.
What can replace ADS1210U/1K?
ADS1210U/1K replacements must preserve the 18-pin SOIC footprint, pin assignments, supply arrangement, reference behavior, and serial protocol. The available cross-reference information identifies ADS1211 as related but notes that compatibility differs around pins 1–3 and 22–24, so it is not a simple same-package substitution without PCB review. Use the Request a Quote form on this page when sourcing the exact MPN or an approved alternative.
Is ADS1210U/1K the same as ADS1211?
No, ADS1210U/1K and ADS1211 are related TI converters but are not unconditionally interchangeable. Texas Instruments support information states that they are pin compatible except for pins 1–3 and pins 22–24, with ADS1211 providing additional channel inputs that must be connected to analog ground on an ADS1210 footprint. Verify the target package and all unused-pin connections before considering a conversion.
When should I choose ADS1210U/1K over another precision ADC?
Choose ADS1210U/1K when the design needs a single differential measurement channel, 24-bit nominal resolution, integrated programmable gain, and an SPI-compatible interface in an 18-pin SOIC package. It is particularly suitable for slow sensor and transducer signals. Choose a different converter when higher throughput, more channels, a different reference scheme, or a smaller footprint is more important than resolution and integrated gain.
Is ADS1210U/1K suitable for industrial process-control applications?
Yes, ADS1210U/1K is explicitly positioned for industrial process-control and smart-transmitter measurements. Its differential input supports measurement of low-level signals referenced to an analog ground, while the integrated PGA reduces the need for a separate analog gain stage. The transmitter design must still include suitable input protection, isolation requirements, calibration, and compliance checks for the target installation.
What is the best ADS1210U/1K application circuit for a low-level sensor?
A practical ADS1210U/1K application circuit connects the sensor differentially to the analog input pins, uses the integrated PGA to scale the signal, and bypasses the 5 V supply and 2.048 V reference close to the device. According to the Texas Instruments ADS1210 family datasheet, the converter is designed for high-resolution measurement. Follow the manufacturer's recommended input and reference networks while adding protection appropriate to the sensor environment.
Does ADS1210U/1K need an external clock or reference?
The ADS1210U/1K includes a 2.048 V internal reference, so a basic measurement design does not require an external reference solely to establish the nominal conversion reference. The manufacturer documentation also supports configurable external-reference operation. Clock and interface details should be taken from the ADS1210 datasheet because the required arrangement depends on the selected synchronization and operating mode.
How should ADS1210U/1K analog inputs be protected?
Protect the ADS1210U/1K analog inputs with a network that limits surge and ESD energy while preserving the differential signal bandwidth required by the selected data rate. Place the protection devices close to the external connector and the analog input routing close to the ADC. The exact clamp level and series resistance must be checked against the ADC absolute-maximum ratings and the sensor's ground range.
Where to buy ADS1210U/1K online?
Use the Request a Quote form on this page to request ADS1210U/1K availability, pricing, and lead time for the exact 18-pin SOIC ordering suffix. The form is the appropriate channel for current sourcing because availability and commercial terms can change quickly. Confirm the full MPN, package, reel quantity, and any required traceability information when placing the order.
What is the price and lead time for ADS1210U/1K?
Use the Request a Quote form on this page for the current ADS1210U/1K price, stock position, minimum order quantity, and lead time. The form supports a request for the exact Texas Instruments MPN and 18-pin SOIC package. Provide the required quantity and target delivery date so the commercial response can be matched to the actual procurement requirement.

Engineering reference data for ADS1210U/1K — comparison, design guidance, and compliance information.

Selection Guide

Choose ADS1210U/1K for a single-channel, high-resolution measurement requiring a differential input, integrated PGA, and an 18-pin SOIC footprint. It is well suited to load cells, pressure transmitters, portable instruments, smart transmitters, chromatography, and precision temperature front ends. Select ADS1210U when its ordering and temperature-grade configuration exactly satisfy the design and the same-family hardware platform is preferred. Consider ADS1201U/1K only after checking its ADC resolution, input architecture, PGA, and serial-interface behavior. ADS1211 should not be treated as an automatic replacement because its additional input pins differ from ADS1210U/1K. For any substitution, verify the complete pin map, supply limits, reference configuration, acquisition timing, and firmware register map.

Comparison with Alternatives

Parameter This Product ADS1210U ADS1201U/1K ADS1211
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package 18-pin SOIC 18-pin SOIC 18-pin SOIC 18-pin SOIC
Architecture Delta-sigma Delta-sigma Delta-sigma Delta-sigma

Key Differentiators

  • Combines high nominal resolution and integrated gain in a single-channel converter (vs ADS1201U/1K)
  • Single-channel architecture simplifies transducer measurement design (vs ADS1211)
  • Family software and hardware continuity (vs ADS1210U)

Design Notes

Route the differential analog input as a short, balanced pair and place the input protection network close to the external connector. Keep the analog path away from digital clocks, DC-DC converter switch nodes, and high-current return paths. Place the ADS1210U/1K supply and reference bypass capacitors close to their pins with short ground returns, and use the package pin-description table in the manufacturer datasheet when assigning every SOIC-18 connection.

Do not assume that a related TI converter is automatically a drop-in replacement. ADS1211 differs around pins 1–3 and 22–24, and the additional input connections must be handled appropriately when adapting an ADS1210 design. Verify pin names, exposed functions, input voltage limits, gain ranges, reference behavior, and serial timing for every proposed substitute. A mechanical SOIC footprint match alone is not sufficient for functional interchangeability.

Choose the data rate, gain, and digital-filter settings together rather than optimizing conversion speed independently. A higher rate can reduce available noise rejection and settling margin, while a lower rate improves resolution for slow sensors but increases latency. For bridge and resistive sensors, include excitation drift and thermal effects in the error budget. Validate the complete gain and calibration chain in hardware because nominal 24-bit converter resolution does not guarantee equivalent system accuracy.

The ADS1210U/1K operates from a single 5 V supply and uses an internal 2.048 V reference in the standard configuration. Decouple the supply at the device with the capacitance and placement specified in the manufacturer application guidance, and keep analog and digital return currents separated as far as the board construction allows. Confirm startup behavior, supply sequencing, and reference settling before taking the first conversion in an automated instrument.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

The verified product information identifies an industrial-temperature-grade device but does not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is not applicable to this industrial converter category.

Related Searches

ads1210u datasheet ADS1210U/1K datasheet ADS1210U/1K pinout ADS1210U/1K datasheet pdf ADS1210U/1K equivalent ADS1210U/1K replacement ADS1210U/1K cross reference ADS1210U/1K price ADS1210U/1K stock ADS1210U/1K SOIC-18 ADS1210U/1K load cell ADS1210U/1K vs ADS1211 Texas Instruments ADS1210U/1K

Related Components & Terms

Texas Instruments ADS1210U/1K ADS1210U ADS1201U/1K ADS1211 Analog-to-digital converter ADC Sigma-delta ADC Delta-sigma architecture 24-bit resolution Differential input Programmable gain amplifier PGA SPI-compatible serial interface Two-wire control mode 2.048 V internal reference 18-pin SOIC SOIC family Surface-mount package Smart transmitter Industrial process control Weigh scale Chromatography Portable instrumentation 16 kSPS data rate
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details