ADS1210U/1K - 24-Bit 1-Channel Sigma-Delta ADC | TI
料号: ADS1210U/1K ✓ 量产中ADS1210U/1K 概述
An analog-to-digital converter is an interface IC that converts continuous analog voltage signals into digital data for processing by a microcontroller, PLC, or measurement controller. Sigma-delta ADCs belong to the ADC category, use an oversampling and digital-filtering architecture, and are commonly selected when high resolution and effective noise performance matter more than very high conversion speed. The ADS1210U/1K is therefore positioned for low-level sensor and transducer measurements rather than high-bandwidth waveform acquisition.
The ADS1210 family is intended for applications such as industrial process control, smart transmitters, weigh scales, chromatography, and portable instrumentation. Its differential input architecture helps reject common-mode noise when the measured source is referenced to an analog ground. The integrated programmable gain amplifier allows the front end to accommodate signals of different amplitudes while preserving useful resolution. The manufacturer describes the converter as offering a maximum data rate of 16 kSPS in the associated product information, making it appropriate for slow, high-accuracy measurements.
The serial interface provides a straightforward connection to embedded systems. SPI-compatible operation supports deterministic digital communication, while the family also offers two-wire control operation for isolated or cost-sensitive interfaces. System design should account for the analog input network, reference selection, bypass capacitors, digital interface timing, and the conversion-data latency associated with the digital filter. The ADS1210U/1K is a single-input device, so applications requiring multiple independent channels will need an additional converter or a multiplexing arrangement.
For low-level sensor connections, use a front-end network that limits overvoltage and ESD events, while keeping the differential signal path short and away from switching nodes. The reference and supply bypass capacitors should be placed close to their associated pins, and the ground-return arrangement should minimize voltage drops in the measurement path. Verify the selected gain, data rate, digital filter setting, and input common-mode range against the operating conditions of the transducer.
This product page consolidates the available technical identity, manufacturer application positioning, sourcing information, and practical integration guidance for the ADS1210U/1K. It also separates same-package alternatives from parts that require a footprint or interface review. When replacing an existing design, confirm the exact package, pin assignments, electrical limits, reference configuration, and interface mode in the manufacturer datasheet before approving the substitution.
直接替换替代料: ADS1210U/1K ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ADS1210U/1K (相同外形与封装尺寸) ——差异在于 Package, Supply Voltage, Mounting Type, Applications, Digital Filter.
ADS1210U
✅ 直接替换联系询价
查看数据手册 →ADS1201U/1K
✅ 直接替换联系询价
查看数据手册 →ADS1210U/1K 最大额定值与电气特性
| ADC Resolution | 24 bit |
| Number of Input Channels | 1 channel |
| Architecture | Delta-sigma |
| Input Type | Differential |
| Maximum Data Rate | 16 kSPS |
| Programmable Gain Amplifier | Integrated |
| Digital Interface | SPI-compatible synchronous serial interface; 2-wire control mode supported by the ADS1210 family |
| 电源电压 | 5 V |
| 基准电压 | 2.048 V |
| 封装 | 18-pin SOIC |
| Package Family | SOIC family |
| 安装类型 | Surface mount |
| Terminal Count | 18 terminals |
| Package Shape | Rectangular |
| Lead Form | Gull wing |
| Temperature Grade | Industrial grade |
| Applications | Smart transmitters, industrial process control, weigh scales, chromatography, and portable instrumentation |
ADS1210U/1K rectangular 引脚配置指南
ADS1210U/1K(rectangular 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: ADS1210U/1K.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ADS1210U/1K 适用于 6 应用s: Load-Cell Weigh Systems, Industrial Pressure Transmitters, Portable Instrumentation, Smart Transmitter Interfaces, Chromatography Data Acquisition, Precision Temperature Measurement.
Load-Cell Weigh Systems
The ADS1210U/1K fits precision load-cell measurement because its 24-bit delta-sigma conversion, differential input, and integrated programmable gain amplifier suit the small bridge signals produced by strain gauges. The converter can operate from a single 5 V supply and provide a 16 kSPS maximum data rate. Place the bridge excitation and analog input routing away from switching converters and motors. Calibration should include bridge offset, gain, scale factor, and system nonlinearity, while the mechanical design must address vibration, creep, and lead-wire resistance.
推荐
Industrial Pressure Transmitters
The ADS1210U/1K is appropriate for industrial pressure and level transmitters that produce a low-level differential signal. Its integrated PGA reduces analog front-end complexity, while the differential input helps reject common-mode voltage present in long industrial wiring. The 24-bit nominal resolution and data rates up to 16 kSPS support accurate process readings without requiring a high-speed SAR ADC. Design the input stage with surge and ESD protection, verify the 5 V supply requirements, and isolate the measurement section when the transmitter interface requires it.
推荐
Portable Instrumentation
The ADS1210U/1K supports compact handheld or portable measurement equipment where a high-resolution reading is more important than rapid waveform capture. The single differential input, integrated PGA, and 18-pin SOIC package simplify board construction around sensors such as thermocouples, strain gauges, and resistive bridges. Low-level analog routing should remain compact, and the digital interface can connect to a microcontroller through the SPI-compatible mode. Battery-powered products should account for the converter's supply requirements and select data rates and filters that balance measurement latency against energy use.
推荐
Smart Transmitter Interfaces
The ADS1210U/1K is suitable for smart-transmitter interfaces that digitize a conditioned sensor signal before applying calibration and transmitting process data. Its 24-bit resolution preserves detail from low-level transducer outputs, while the integrated programmable gain amplifier allows one design to cover multiple sensor ranges. The manufacturer identifies smart transmitters as an intended application. Use differential input routing, local reference and supply bypassing, and a protected interface to maintain measurement integrity while the transmitter communicates with a host controller.
推荐
Chromatography Data Acquisition
The ADS1210U/1K can be used in chromatography measurement systems when the sensor output requires high nominal resolution and the acquisition rate is relatively low. The differential input supports direct connection to suitable transducer front ends, while the integrated PGA reduces the need for separate gain amplification. Configure the data rate and digital filtering according to the required settling time and channel bandwidth. High-impedance sensor nodes and reference routing require careful PCB layout because leakage, stray capacitance, and ground disturbance can affect the acquired result.
推荐
Precision Temperature Measurement
The ADS1210U/1K can digitize low-level temperature sensor signals when the front end provides a differential voltage suitable for the ADC's PGA. Its 24-bit resolution and differential architecture are useful for bridge-based temperature sensing and precision sensor interfaces. The design should account for thermocouple cold-junction compensation where applicable, sensor excitation stability, and EMI near the input pins. For faster sampling, selectable data rates up to 16 kSPS provide some flexibility, but system latency remains governed by the configured digital filter.
推荐
推荐产品汇总
工程参考数据: ADS1210U/1K ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ADS1210U | ADS1201U/1K | ADS1211 |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 18-pin SOIC | 18-pin SOIC | 18-pin SOIC | 18-pin SOIC |
| Architecture | Delta-sigma | Delta-sigma | Delta-sigma | Delta-sigma |
关键差异点
- Combines high nominal resolution and integrated gain in a single-channel converter (对比 ADS1201U/1K)
- Single-channel architecture simplifies transducer measurement design (对比 ADS1211)
- Family software and hardware continuity (对比 ADS1210U)
设计说明
Route the differential analog input as a short, balanced pair and place the input protection network close to the external connector. Keep the analog path away from digital clocks, DC-DC converter switch nodes, and high-current return paths. Place the ADS1210U/1K supply and reference bypass capacitors close to their pins with short ground returns, and use the package pin-description table in the manufacturer datasheet when assigning every SOIC-18 connection.
Do not assume that a related TI converter is automatically a drop-in replacement. ADS1211 differs around pins 1–3 and 22–24, and the additional input connections must be handled appropriately when adapting an ADS1210 design. Verify pin names, exposed functions, input voltage limits, gain ranges, reference behavior, and serial timing for every proposed substitute. A mechanical SOIC footprint match alone is not sufficient for functional interchangeability.
Choose the data rate, gain, and digital-filter settings together rather than optimizing conversion speed independently. A higher rate can reduce available noise rejection and settling margin, while a lower rate improves resolution for slow sensors but increases latency. For bridge and resistive sensors, include excitation drift and thermal effects in the error budget. Validate the complete gain and calibration chain in hardware because nominal 24-bit converter resolution does not guarantee equivalent system accuracy.
The ADS1210U/1K operates from a single 5 V supply and uses an internal 2.048 V reference in the standard configuration. Decouple the supply at the device with the capacitance and placement specified in the manufacturer application guidance, and keep analog and digital return currents separated as far as the board construction allows. Confirm startup behavior, supply sequencing, and reference settling before taking the first conversion in an automated instrument.
合规信息
The verified product information identifies an industrial-temperature-grade device but does not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is not applicable to this industrial converter category.