ADS1224IPWT - 24-Bit 240-SPS 4-Channel ADC | Texas Instruments
MPN: ADS1224IPWT ✓ ActiveADS1224IPWT Overview
A delta-sigma ADC is a voltage-to-digital converter that uses a continuous-time modulator and digital filtering to achieve high resolution from low-frequency analog signals. Its hierarchy includes ADC, data converter, analog-to-digital converter, signal-chain IC, and semiconductor. This architecture is especially effective when high resolution, low noise, and limited conversion speed are more important than fast transient capture.
The ADS1224IPWT combines four differential input channels with an integrated high-impedance buffer. These features suit bridge sensors, resistive transducers, and low-level analog front ends where source impedance can be high. Its 24-bit conversion resolution preserves fine detail in pressure, temperature, force, and industrial process measurements, while the 240-SPS rate supports continuously updated instrument readings.
Internally, the converter uses a delta-sigma modulator and digital filter as the foundation of its conversion process. The four-channel differential multiplexer allows one analog measurement system to interrogate several sensing elements through paired positive and negative inputs. The high-impedance buffer reduces loading of adjacent sensor circuits, while the serial interface provides a compact connection to a microcontroller or embedded controller.
Typical uses include portable measurement instruments, industrial sensor interfaces, load-cell signal chains, bridge-based pressure systems, and precision temperature measurement. The low-power, space-saving format is particularly useful when the analog front end must fit beside a sensor and digital controller without adding another converter package.
Design the input network so source impedance remains compatible with the converter's acquisition requirements, and follow the manufacturer datasheet for reference circuitry, grounding, and decoupling. Keep sensitive analog routing separated from switching nodes and digital clock traces to preserve the benefit of the 24-bit conversion resolution.
This product page combines the ADS1224IPWT specifications, pin-compatible ordering information, application guidance, and design considerations into one engineering-focused reference for selecting and implementing the converter.
Drop-in alternatives for ADS1224IPWT — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
ADS1224IPWTG4
✅ Drop-In📋 Reference alternative (not in catalog)
ADS1224IPWT Maximum Ratings & Electrical Characteristics
| Resolution | 24 bit |
| Conversion Rate | 240 samples/s |
| Input Multiplexer Channels | 4 channels |
| Input Configuration | 4-channel differential input multiplexer |
| Input Buffer | High-impedance buffer |
| Architecture | Delta-sigma |
| Output Interface | Serial output |
| Package | 20-pin TSSOP (PW) |
| Package Mounting Type | Surface mount |
| Operating Temperature Range | -40°C to +85°C |
| Temperature Grade | Industrial |
ADS1224IPWT surface mount Pin Configuration Guide
Pin configuration for ADS1224IPWT (surface mount package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.
No detailed pinout data available for ADS1224IPWT.
Refer to the datasheet for full pin configuration.
Typical Applications
ADS1224IPWT is suitable for 6 applications: Portable Precision Measurement, Industrial Sensor Interface, Load-Cell and Bridge Measurement, Pressure and Flow Transducer Interface, Precision Temperature Acquisition, Medical and Diagnostic Instrument Signal Chain.
Portable Precision Measurement
ADS1224IPWT fits portable instruments that repeatedly measure low-level analog signals while keeping the converter compact and power-conscious. Its 24-bit resolution preserves fine measurement detail, while the four-channel differential multiplexer lets one ADC service several sensing elements. The 240-SPS rate supports continuously updated readings without switching to a much faster, generally higher-power ADC. Its 20-pin TSSOP package also leaves more board area for the sensor interface, display, and controller. A practical implementation places the ADC beside the analog front end, routes each differential pair away from digital clocks, and uses the manufacturer-recommended reference and decoupling network.
Recommended
Industrial Sensor Interface
ADS1224IPWT is appropriate for industrial sensor interfaces requiring more resolution than a conventional 12-bit or 16-bit converter can provide. The four-channel differential multiplexer supports multiplexing among multiple bridges or conditioned transducer outputs, and the high-impedance buffer reduces loading of high-source-impedance sensors. The 24-bit conversion result can expose small process variations that would otherwise be hidden by quantization noise. Its -40°C to +85°C industrial temperature range also suits equipment operating outside consumer-temperature limits. Keep sensor returns and analog inputs away from relay contacts, motor traces, and high-current power paths to prevent coupled noise from limiting the converter’s usable resolution.
Recommended
Load-Cell and Bridge Measurement
ADS1224IPWT is well matched to load-cell and resistive-bridge front ends because differential input selection supports rejecting common-mode voltage while the high-impedance buffer reduces loading of the bridge. A 24-bit result can capture small force changes represented as millivolt-level differential signals, and the 240-SPS rate is adequate for static and slowly changing loads. A practical circuit should include protection appropriate to the mechanical environment and connect the analog ground and digital ground according to the manufacturer guidance. Avoid long unprotected traces between the bridge and ADC, because capacitive pickup can overwhelm a high-resolution conversion even when the converter itself is operating correctly.
Recommended
Pressure and Flow Transducer Interface
ADS1224IPWT can serve as the core conversion device for pressure, differential-pressure, and low-flow transducers that produce small differential analog outputs. The four selectable differential channels reduce the need for separate converters when several process points share an enclosure. Its 24-bit resolution supports fine resolution around the transducer’s operating point, while 240-SPS provides continuous process updates. The integrated high-impedance buffer is valuable when the sensor has appreciable output impedance. Place protection components close to external connector entries, keep the sensitive input path compact, and follow the manufacturer input-capacitance and reference recommendations so switching transients do not dominate the measurement.
Recommended
Precision Temperature Acquisition
ADS1224IPWT is suitable for precision temperature acquisition from resistive sensors when the system prioritizes measurement resolution rather than very high conversion speed. The four-channel differential multiplexer supports multiple RTD or thermistor channels, and the 24-bit result helps preserve small resistance-to-temperature changes after excitation and linearization. The 240-SPS sampling rate is suitable for thermal systems whose response times are far longer than one millisecond. Use a stable excitation or reference arrangement, confirm the allowed sensor excitation through the manufacturer design guidance, and isolate sensitive analog traces from switching power nodes. This prevents sensor resistance, lead length, and thermal gradients from becoming the dominant source of measurement error.
Recommended
Medical and Diagnostic Instrument Signal Chain
ADS1224IPWT can support slow, precision signal acquisition in medical and diagnostic instruments where low-level differential signals must be digitized with compact hardware. The high-impedance input buffer helps interface with sensitive transducers, while four multiplexed differential channels provide flexibility for shared sensor wiring. The 24-bit resolution supports high-resolution representations of gradual physiological or laboratory measurements, and the 240-SPS rate suits signals that do not require high-bandwidth sampling. Leakage, grounding, isolation, and patient-safety requirements remain system-level constraints. Follow the manufacturer reference design and applicable medical-system design practices, particularly when protection networks can introduce leakage or disturb the sensor source impedance.
Recommended
Recommended Products Summary
Engineering reference data for ADS1224IPWT — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | ADS1224IPWTG4 |
|---|---|---|
| Package | 20-pin TSSOP (PW) | 20-pin TSSOP (PW) - same |
| Brand | Texas Instruments | Texas Instruments |
| Resolution | 24 bit | 24 bit |
| Conversion Rate | 240 samples/s | 240 samples/s |
| Input Multiplexer | 4-channel differential input multiplexer | 4-channel differential input multiplexer |
| Input Buffer | High-impedance buffer | High-impedance buffer |
| ADC Architecture | Delta-sigma | Delta-sigma |
| Output Interface | Serial output | Serial output |
| Operating Temperature | -40°C to +85°C | -40°C to +85°C |
Key Differentiators
- Identical core conversion performance (vs ADS1224IPWTG4)
- Identical industrial temperature coverage (vs ADS1224IPWTG4)
- Identical pin-compatible package (vs ADS1224IPWTG4)
Design Notes
Place the ADS1224IPWT close to the analog sensor interface and connect differential inputs with tightly matched, short traces. Keep the serial interface on the opposite side of the device and avoid routing it beneath the analog input network. The four-channel multiplexer and high-impedance buffer can reduce loading, but long PCB traces still introduce coupling and parasitic capacitance that become increasingly important as the target resolution approaches the converter’s 24-bit capability.
Use the reference, grounding, and decoupling configuration shown in the manufacturer datasheet rather than copying a generic ADC layout. Maintain the recommended relationship among the analog supply, digital supply, analog ground, digital ground, and external reference connections. In particular, do not treat the exposed electrical performance of the 24-bit converter as useful if reference instability, ground bounce, or supply ripple dominates the measurement chain.
Keep clock and switching-node routing away from REFP, REFN, and the selected analog inputs. If the source impedance is high or varies, validate the settling behavior at the selected data rate and digital-filter configuration. This check is important because a multiplexer transition must settle before conversion; insufficient acquisition time or excessive source impedance can create correlated errors that resemble poor converter linearity.
Compliance Information
The industrial -40°C to +85°C temperature rating is confirmed by the Texas Instruments ordering page. No explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals status was established from the cited pages.