ADS1259BIPW - 24-Bit 14.4 kSPS Delta-Sigma ADC | Texas Instruments
MPN: ADS1259BIPW ✓ ActiveADS1259BIPW Overview
A delta-sigma ADC is a signal-conversion IC that uses oversampling and digital filtering to convert an analog input into a high-resolution digital value. It belongs to the data-converter IC hierarchy, which includes ADCs and DACs within semiconductor signal-chain and measurement systems. The ADS1259 is intended for sensors and industrial signals that require high resolution without the conversion speed of a SAR ADC.
The principal specifications are a 24-bit resolution, a maximum conversion rate of 14.4 kSPS, one analog input channel, and an SPI interface. Its integrated low-drift voltage reference improves measurement stability by reducing sensitivity to supply-voltage changes and temperature drift. These characteristics make the device suitable for industrial transmitters, pressure measurement, process monitoring, and precision sensor interfaces.
The converter uses a delta-sigma architecture to shape quantization noise and achieve high resolution from a narrow-band input. It can be paired with an external signal amplifier such as the PGA280 to create a high-accuracy measurement system. Its serial interface reduces the number of PCB connections compared with a parallel ADC, while the compact TSSOP package simplifies high-density instrument construction.
Typical applications include factory automation, process-control loops, industrial pressure transducers, laboratory instrumentation, and low-frequency sensor acquisition. The 14.4 kSPS rate captures changing process variables without requiring a very high-speed data-acquisition system. The integrated low-drift reference is especially useful when long-term measurement accuracy matters more than maximum throughput.
Designers should use the manufacturer pin-description and typical-application circuits when assigning signals and decoupling components. Input filtering, reference bypassing, grounding, and SPI clock implementation directly affect achievable noise performance. Confirm input range, gain settings, latency, and digital-filter behavior against the manufacturer datasheet before finalizing signal-chain calculations.
This product data combines the official device characteristics, ordering information, packaging details, replacement analysis, and application-specific engineering guidance. It also identifies where an exact drop-in replacement is available and where a functional substitute would require board-level verification.
Drop-in alternatives for ADS1259BIPW — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
ADS1259IPW
✅ Drop-In📋 Reference alternative (not in catalog)
ADS1259BIPW Maximum Ratings & Electrical Characteristics
| Resolution | 24 bit |
| Maximum Conversion Rate | 14.4 kSPS |
| Input Channels | 1 channel |
| Analog Inputs | 1 input |
| ADC Architecture | Delta-sigma |
| Internal Reference | Low-drift voltage reference |
| Digital Interface | SPI |
| Application Class | Industrial |
| Package | 20-pin TSSOP (PW) |
| Pin Count | 20 pins |
| Operating Temperature Range | -40°C to +105°C |
| Mounting Type | Surface mount |
ADS1259BIPW 20-pin tssop (pw) Pin Configuration Guide
Pin configuration for ADS1259BIPW (20-pin tssop (pw) package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.
No detailed pinout data available for ADS1259BIPW.
Refer to the datasheet for full pin configuration.
Typical Applications
ADS1259BIPW is suitable for 6 applications: Industrial Pressure Transmitters, Factory Process-Control Loops, Precision Test and Measurement Instruments, Industrial Sensor Acquisition, Low-Level Voltage Measurement, Automated Test Equipment.
Industrial Pressure Transmitters
The ADS1259BIPW fits industrial pressure transmitters that require a stable, high-resolution measurement from a low-level bridge or conditioned sensor signal. Its 24-bit conversion resolution and 14.4 kSPS maximum rate provide enough data density for pressure-loop monitoring without demanding the throughput of a fast SAR converter. The integrated low-drift reference helps preserve calibration performance as the equipment operates from -40°C to +105°C. Use the device after suitable excitation, amplification, filtering, and common-mode conditioning, and verify the applicable excitation and input limits in the manufacturer datasheet.
Recommended
Factory Process-Control Loops
The ADS1259BIPW is appropriate for factory process-control loops that monitor temperature, pressure, flow, or level through relatively slow-moving analog signals. A 14.4 kSPS maximum conversion rate provides frequent updates for supervisory control, while 24-bit resolution preserves fine detail in sensor outputs. The single-channel delta-sigma architecture simplifies signal conditioning, and the low-drift reference reduces sensitivity to supply and environmental changes. In a production controller, the ADC can feed a microcontroller or PLC through SPI while keeping the analog front end isolated from high-energy drive stages.
Recommended
Precision Test and Measurement Instruments
The ADS1259BIPW supports precision laboratory and bench instruments that must resolve small analog changes with a stable reference. Its 24-bit resolution is valuable for bridge sensors, strain-gauge signals, and low-level conditioned voltages, while the 14.4 kSPS rate supports responsive measurements without requiring a high-speed data-capture architecture. The low-drift internal reference improves reproducibility across operating conditions, and the SPI interface minimizes board area in compact instruments. Use careful analog grounding and filtering to realize the converter's intended noise performance.
Recommended
Industrial Sensor Acquisition
The ADS1259BIPW is well suited to acquisition cards for resistive, voltage, and conditioned current sensors used in industrial equipment. Its single-channel input can monitor a selected bridge or transducer, and the 24-bit resolution can retain small process variations that would be difficult to distinguish with a lower-resolution converter. The 14.4 kSPS ceiling provides enough sampling density for supervisory diagnostics and control updates. Because the device is a delta-sigma ADC, system designers should account for digital filtering and conversion latency when timing control loops or comparing sampled data with events.
Recommended
Low-Level Voltage Measurement
The ADS1259BIPW can digitize small conditioned voltages where amplitude resolution is more important than very high conversion speed. A 24-bit result creates 16,384 distinguishable digital-code levels, allowing a system to preserve fine changes in a measurement after suitable amplification and filtering. The low-drift reference supports stable readings in controlled industrial environments, and the 20-pin TSSOP package allows a compact analog measurement section. Confirm the converter's gain, input range, offset behavior, and noise specification in the manufacturer datasheet before choosing resistor values and amplifier scaling.
Recommended
Automated Test Equipment
The ADS1259BIPW is useful in automated test equipment that evaluates slow analog parameters under controlled conditions. Its 14.4 kSPS maximum conversion rate supports practical test sequencing, while 24-bit resolution can reveal small deviations in outputs from sensors, references, and signal-conditioning networks. The SPI interface allows a test controller to configure acquisition and retrieve conversion results efficiently. A key design consideration is synchronization: account for digital-filter settling and conversion latency when defining measurement timing. Use the manufacturer's digital timing diagrams to establish command and data-capture sequences.
Recommended
Recommended Products Summary
Engineering reference data for ADS1259BIPW — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | ADS1259IPW |
|---|---|---|
| Package | 20-pin TSSOP (PW) | 20-pin TSSOP (PW) |
| Brand | Texas Instruments | Texas Instruments |
| Resolution | 24 bit | 24 bit |
| Maximum Conversion Rate | 14.4 kSPS | 14.4 kSPS |
| Input Channels | 1 channel | 1 channel |
| ADC Architecture | Delta-sigma | Delta-sigma |
| Digital Interface | SPI | SPI |
| Product Positioning | Advanced ADS1259 ordering option | Compact ADS1259 option for multiple installations |
Key Differentiators
- Direct same-family drop-in option (vs ADS1259IPW)
- Integrated low-drift reference (vs ADS1259IPW)
- Industrial environmental range (vs ADS1259IPW)
Design Notes
Place the ADC input, reference, and decoupling connections according to the manufacturer typical-application layout. Keep sensitive analog traces short, route digital SPI signals away from input and reference nodes, and provide a quiet ground return for the converter. Decoupling capacitors should be placed directly at the associated power pins with short ground paths to reduce supply disturbance and preserve measurement repeatability.
Use the SPI interface according to the manufacturer timing diagrams and keep the serial clock, chip-select, reset, and data-ready routing compact and controlled. Account for the configured digital-filter settling time and conversion latency when initiating or capturing a conversion. If the analog input is slow-changing, synchronize control software with the data-ready indication rather than assuming that every SPI transaction represents a newly completed conversion.
Do not select amplifier gain or analog bias values without checking the ADC input range, common-mode limits, absolute maximum ratings, and selected PGA configuration. A 24-bit nominal resolution does not guarantee equivalent useful accuracy if the front end saturates, the source impedance is unsuitable, or reference and power arrangements violate the datasheet application requirements. Validate the complete analog path across temperature and expected sensor tolerance.
Compliance Information
The device is described as an industrial ADC, but no explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was identified. The component is not presented as an AEC-Q100-qualified automotive device.