CD4536BD3 - 24-Stage CMOS Programmable Timer | Texas Instruments
MPN: CD4536BD3 ✓ ActiveCD4536BD3 Overview
A programmable timer is an integrated timing component that counts clock edges or free-running oscillator cycles and produces an output after a selected count. The CD4536B family belongs to the CMOS logic and clock-and-timing hierarchy: programmable timer → counter → clock and timing IC → integrated circuit. This makes it useful when a design needs adjustable delays, periodic events, long timing intervals, or multiple selectable time constants without a microcontroller.
The principal feature is a 24-stage ripple-binary counter that can count from 1 to 2^24. The first eight stages may be bypassed, allowing the 4-bit A, B, C, and D selection inputs to address one of 16 outputs from the remaining stages. This programmable selection shortens the effective count range compared with using all 24 stages and gives designers a practical way to set different delay or period values in one circuit.
The CD4536B can operate from an external clock or from an RC timing network connected to the on-chip oscillator. According to the Texas Instruments CD4536B datasheet, the monostable input can be disabled by connecting MONO IN to ground through a resistor of 10 kΩ or higher. The device therefore supports both continuously running oscillator applications and triggered monostable timing functions, subject to the detailed connection and trigger requirements in the datasheet.
Typical uses include industrial pulse and delay generation, periodic control timers, laboratory timing modules, counters, automotive-style repetitive control logic, and embedded control subsystems where a dedicated timer is preferable to software timing. The selectable counter outputs are especially useful when one timer must support several operating rates or when the required interval changes with a configuration input.
When laying out a CD4536BD3 circuit, keep the oscillator and timing components close to the associated device pins, maintain the required bypass-network connections, and account for CMOS input leakage and temperature effects when selecting external resistors or capacitors. Validate pulse width and count accuracy over the full intended supply-voltage and temperature range rather than relying only on nominal RC values.
This product record combines the verified device identity, package and timing architecture with practical implementation guidance. It also organizes same-family drop-in alternatives and distinguishes which electrical details require confirmation against the manufacturer datasheet before production release.
Drop-in alternatives for CD4536BD3 — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Variants in this series
Same-series models that are drop-in compatible with CD4536BD3 (same form factor and footprint) — differing in Mounting Type, Package.
CD4536BDWR
✅ Drop-In📋 Reference alternative (not in catalog)
CD4536BE
✅ Drop-In ⚠️ Specs UnverifiedContact for price
View Datasheet →CD4536BF
✅ Drop-In ⚠️ Specs Unverified📋 Reference alternative (not in catalog)
CD4536BM
✅ Drop-In ⚠️ Specs Unverified📋 Reference alternative (not in catalog)
CD4536BN
✅ Drop-In ⚠️ Specs Unverified📋 Reference alternative (not in catalog)
CD4536BD3 Specifications
| Product Type | CMOS programmable timer |
| Counter Architecture | 24-stage ripple-binary counter |
| Maximum Count | 2^24 counts |
| Programmable Output Stages | 16 selectable outputs |
| Maximum Clock Frequency | 5 MHz |
| Clock Sources | External clock or on-chip RC oscillator |
| Output Selection Inputs | 4-bit BCD selection via A, B, C, and D inputs |
| Bypass Control | 8-BYPASS input bypasses the first 8 counter stages |
| Monostable Mode Input | MONO IN |
| Monostable Disable Resistance | 10 kΩ or higher from MONO IN to ground |
| Package | 16-pin SOIC |
| Mounting Type | Surface mount |
CD4536BD3 16-pin soic Pin Configuration Guide
Pin configuration for CD4536BD3 (16-pin soic package). Pin numbering, functions, and connection diagrams are defined in the manufacturer datasheet. Refer to it for the exact footprint and soldering guidelines.
No detailed pinout data available for CD4536BD3.
Refer to the datasheet for full pin configuration.
Typical Applications
CD4536BD3 is suitable for 6 applications: Programmable Industrial Delay Generator, Periodic Event and Trigger Control, Long-Interval Counter, Laboratory Pulse and Time-Base Module, Automotive and Transportation Timing Control, Embedded Sequence and Retrigger Control.
Programmable Industrial Delay Generator
The CD4536BD3 is suitable for industrial pulse and delay generation because its 24-stage ripple-binary counter can represent up to 2^24 clock counts, while the selectable output stages permit several effective timing values. The timer can operate from an external clock or an RC oscillator, allowing the designer to choose between a stable system-derived time base and a locally configured oscillator. Its 16-pin SOIC package also supports conventional surface-mount assembly. For industrial use, confirm the exact suffix's operating-temperature range and output-drive capability against the Texas Instruments CD4536B datasheet before release.
Recommended
Periodic Event and Trigger Control
A CD4536BD3 can generate repeatable periodic events by dividing an incoming clock with its internal counter and selecting the desired output stage. The 4-bit A, B, C, and D selection inputs address one of 16 outputs when the first eight stages are bypassed, making it practical to support several pulse rates without changing the oscillator network. In a control panel, these outputs can initiate actuator updates, sampling requests, or status transitions. Validate pulse-width margins and logic-level compatibility with the selected external clock, and route timing outputs away from switching nodes to reduce coupling.
Recommended
Long-Interval Counter
The 24-stage counter in the CD4536BD3 allows long elapsed-time measurement from an external clock without requiring a microcontroller counter. Counting up to 2^24 provides substantial headroom for minute-scale or hour-scale timing when the source frequency is appropriately divided. The A, B, C, and D inputs can select among 16 remaining outputs after bypassing the first eight stages, enabling programmable count windows. This architecture is useful in laboratory timers, maintenance counters, and repetitive test fixtures. Use the manufacturer timing diagrams to establish setup and hold constraints around selection changes.
Recommended
Laboratory Pulse and Time-Base Module
The CD4536BD3 can form the core of a laboratory timing module because it accepts an external clock or uses an on-chip RC oscillator. A stable external reference can improve repeatability, while the RC configuration offers a compact autonomous timer. The programmable output selection provides multiple tap points for test points, trigger sources, and external divider chains. Because the timer operates in the CMOS clock-and-timing category, designers can pair it with logic gates, counters, and display drivers rather than a microcontroller for simple fixed-function instruments. Validate oscillator tolerance, output jitter, and reset behavior across the intended operating conditions.
Recommended
Automotive and Transportation Timing Control
The CD4536BD3's programmable timer architecture can support repetitive timing functions in transportation equipment where a fixed logic timer is preferable to a general-purpose controller. The 24-stage counter supports long intervals, and multiple selectable outputs can serve different actuator or indicator timing sequences. A transportation design should use the exact qualified order variant and verify its temperature range, supply limits, output behavior, and automotive qualification status in the manufacturer documentation. The CD4536BD3 record does not by itself establish AEC-Q100 qualification, so that requirement must be confirmed separately for the selected suffix.
Recommended
Embedded Sequence and Retrigger Control
The CD4536BD3 is useful in fixed-function embedded systems that require delayed or retriggerable actions without allocating a microcontroller timer peripheral. Its MONO IN path supports monostable-style operation, while the counter outputs provide selectable timing intervals for sequential control stages. A typical implementation drives the clock from a system oscillator, selects an output stage digitally, and uses the resulting pulse to release another logic block. Ensure the trigger signal meets the input timing requirements and include suitable reset or power-on conditioning so the counter begins from a defined state.
Recommended
Recommended Products Summary
Engineering reference data for CD4536BD3 — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | CD4536BDWR | CD4536BE | CD4536BF | CD4536BM | CD4536BN |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC | 16-pin SOIC - same | 16-pin SOIC - same | 16-pin SOIC - same | 16-pin SOIC - same | 16-pin SOIC - same |
| Product Type | CMOS programmable timer | Programmable timer IC | CD4536B programmable timer | CD4536B programmable timer | CD4536B programmable timer | CD4536B programmable timer |
| Counter Stages | 24 ripple-binary stages | 24 stages | 24 stages | 24 stages | 24 stages | 24 stages |
| Maximum Count | 2^24 counts | 2^24 counts | 2^24 counts | 2^24 counts | 2^24 counts | 2^24 counts |
| Maximum Clock Frequency | 5 MHz | 5 MHz | 5 MHz family rating; confirm suffix | 5 MHz family rating; confirm suffix | 5 MHz family rating; confirm suffix | 5 MHz family rating; confirm suffix |
| Programmable Output Stages | 16 selectable outputs | 16 selectable outputs | 16 selectable outputs | 16 selectable outputs | 16 selectable outputs | 16 selectable outputs |
| Timing Sources | External clock or on-chip RC oscillator | External clock or RC oscillator | External clock or RC oscillator | External clock or RC oscillator | External clock or RC oscillator | External clock or RC oscillator |
| Selection Inputs | 4-bit A, B, C, and D selection | 4-bit selection | 4-bit selection | 4-bit selection | 4-bit selection | 4-bit selection |
Key Differentiators
- Directly compatible ordering path within the CD4536B family (vs CD4536BDWR)
- Long programmable count range (vs CD4536BE)
- Programmable timing with external-clock flexibility (vs CD4536BF)
Design Notes
Place the external clock or RC oscillator components close to their associated CD4536BD3 pins and route the timing nets away from switching-regulator outputs and high-current switching nodes. The timer can operate up to 5 MHz, so long or adjacent clock traces may couple noise into the count sequence. Use a ground reference plane, minimize loop area, and keep the A, B, C, and D selection traces short enough to satisfy the setup and hold requirements shown in the manufacturer timing diagrams.
Do not assume that every CD4536B suffix has identical temperature, supply-voltage, or output-drive ratings. The D3 order code identifies the target assembly, but a proposed replacement must be checked against the exact ordering table, including the operating-temperature grade and supply limits. Also observe the documented 10 kΩ-or-higher resistance from MONO IN to ground when the monostable input is disabled; this prevents the input from interfering with the oscillator and counter.
Provide the bypass capacitance and supply sequencing required by the manufacturer datasheet, and keep power-distribution return paths short. CMOS timer inputs can respond to leakage and injected charge, so unused or slowly changing control inputs should not be allowed to float. When the circuit combines CD4536BD3 with modern digital logic, verify every input and output voltage against both devices' logic thresholds at the actual supply voltage; do not assume compatibility solely because both circuits use CMOS technology.
The 24-stage ripple counter permits long timing intervals, but the exact propagation behavior of each stage contributes to timing tolerance. For precise intervals, use a stable external clock and validate the selected output delay over supply-voltage and temperature corners. If the RC oscillator is used, calculate component tolerances and CMOS leakage effects before treating the nominal timing value as production-accurate. Do not change the selected counter stage during operation unless the timing diagram confirms that transition behavior is acceptable.
Compliance Information
No specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statement was identified for the exact CD4536BD3 order code. AEC-Q100 is marked not applicable because the device is a timer IC rather than an automotive-qualified power device; verify automotive requirements separately for the selected suffix.