DG409CUE+ Dual 4:1 CMOS Multiplexer | Maxim Integrated
MPN: DG409CUE+ ✓ ActiveDG409CUE+ Overview
A CMOS analog multiplexer is an interface IC that connects multiple signal inputs to a shared output under digital control. Each DG409CUE+ circuit uses address and enable logic to select one of four inputs. The DG409 family belongs to the broader analog switch and multiplexer hierarchy, where low on-resistance, predictable channel behavior, and controlled switching are central to accurate signal routing.
The DG409CUE+ provides improved matching between channels, guaranteed at 8 ohms maximum, and flatness over the specified signal range of 9 ohms maximum. Its 100-ohm maximum on-resistance limits signal attenuation when the device routes low-frequency analog signals. ESD protection greater than 2,000 V according to MIL-STD-883 Method 2002 adds handling protection for the switching pins.
The device is designed for both single-ended and balanced routing architectures. Two multiplexers in one package can implement a 4:1 analog selection function, a dual-channel instrumentation interface, or a paired differential signal path. Its CMOS implementation supports bidirectional analog conduction, allowing the selected terminals to serve as inputs or outputs as required by the circuit topology.
Typical applications include data acquisition, sample-and-hold systems, battery monitoring, test equipment, signal routing in industrial controls, and precision analog measurement. The dual 4:1 organization is particularly useful when two related signals must be selected simultaneously, such as differential sensor outputs, although the address and enable timing should be coordinated to prevent unintended channel transitions.
PCB layout should minimize resistance and inductance in analog signal paths. Place the TSSOP-16 device close to connector and measurement circuitry, route selected and unselected analog terminals away from fast digital clocks, and use a solid ground plane. Supply bypassing should be placed at the power pins, while address and enable traces require clean return paths to prevent switching transients from coupling into the selected channel.
This page combines the device's key electrical characteristics, functional positioning, application guidance, design precautions, and compatibility analysis. It also provides practical criteria for determining when the DG409CUE+ fits a routing requirement and when a different package or multiplexer architecture should be selected.
Drop-in alternatives for DG409CUE+ — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
DG409CUE
✅ Drop-In📋 Reference alternative (not in catalog)
DG409CUE+ Specifications
| Multiplexer Type | Dual 4:1 CMOS analog multiplexer |
| Number of Circuits | 2 circuits |
| On-Resistance | 100 ohms maximum |
| Channel Matching | 8 ohms maximum |
| Flatness Over Signal Range | 9 ohms maximum |
| Single-Supply Voltage | Up to +30 V |
| Dual-Supply Voltage | Up to ±20 V |
| ESD Protection | Greater than 2,000 V per MIL-STD-883 Method 2002 |
| Technology | CMOS |
| Package | 16-pin TSSOP |
| Mounting Type | Surface mount |
| Analog Signal Conduction | Bidirectional |
| Production Status | Production |
DG409CUE+ 16-pin tssop Pin Configuration Guide
Pin configuration for DG409CUE+ (16-pin tssop package). Pin numbering, functions, and connection diagrams are defined in the manufacturer datasheet. Refer to it for the exact footprint and soldering guidelines.
No detailed pinout data available for DG409CUE+.
Refer to the datasheet for full pin configuration.
Typical Applications
DG409CUE+ is suitable for 6 applications: Battery Monitoring Systems, Data Acquisition Front Ends, Test and Measurement Routing, Industrial Control Signal Multiplexing, Sample-and-Hold Systems, Balanced Differential Signal Routing.
Battery Monitoring Systems
The DG409CUE+ fits battery-monitoring boards that must route several cell or pack voltages to a common measurement amplifier. Its two independent 4:1 circuits can select related voltage pairs, while the 100-ohm maximum on-resistance limits attenuation when the source impedance is much higher than the switch resistance. The 8-ohm maximum channel matching and 9-ohm maximum flatness also help maintain consistency between selected battery taps. The device can operate from a single supply up to +30 V, making it relevant for industrial packs whose monitored voltages remain within that limit. Protection components and high-impedance dividers should be placed ahead of the multiplexer so that the switch handles a controlled signal range.
Recommended
Data Acquisition Front Ends
The DG409CUE+ is appropriate for data-acquisition front ends that must connect several sensor outputs to a shared analog-to-digital converter input. Two 4:1 sections permit paired channel selection, which is useful for differential measurements when both sides of a sensor require synchronized routing. A maximum on-resistance of 100 ohms is generally suitable for low-frequency, high-impedance sensors, while the specified 8-ohm channel matching and 9-ohm flatness reduce amplitude changes caused by channel selection. The common terminals conduct bidirectionally, allowing flexible signal-flow arrangements. Designers should verify converter acquisition time, mux settling behavior, source impedance, and the address-to-enable timing before fixing the sampling sequence.
Recommended
Test and Measurement Routing
The DG409CUE+ can route test signals in instrumentation where several sources must connect to one measurement chain without relocating probes. Its dual 4:1 organization allows two routing paths to be switched together, reducing the number of separate multiplexer packages needed for paired or comparative tests. The 100-ohm maximum on-resistance is suitable for many low-frequency instrumentation signals, and the 8-ohm maximum channel matching supports repeatable comparisons across inputs. For high-impedance buffers or precision dividers, account for the switch resistance when calculating attenuation. Keep sensitive analog routes away from digital address lines and use a low-impedance ground return to minimize coupling into the selected measurement path.
Recommended
Industrial Control Signal Multiplexing
The DG409CUE+ supports industrial control boards that must select among multiple analog command, feedback, or sensor signals using digital control logic. Its +30 V maximum single-supply operation is useful for systems with higher-voltage process signals, while the ±20 V dual-supply range supports bipolar analog environments. Two independent multiplexers can manage separate command and feedback channels without adding another package. The improved matching of 8 ohms maximum and flatness of 9 ohms maximum help reduce errors when the controller compares signals from different sources. The system designer must still confirm common-mode limits, input overvoltage protection, control thresholds, and whether a 100-ohm maximum switch resistance is acceptable for the driven load.
Recommended
Sample-and-Hold Systems
The DG409CUE+ can be used to select which signal is presented to a sample-and-hold stage when multiple sources require periodic capture. The bidirectional analog paths support both source and destination signal flow, and the two 4:1 sections can select two related channels for matched sampling. Its low specified channel matching of 8 ohms maximum and flatness of 9 ohms maximum are important when the downstream circuit distinguishes amplitude differences between channels. Designers should account for switch on-resistance, control timing, and downstream sampling time rather than assuming instantaneous selection. Short analog traces, a continuous ground plane, and separation from high-speed control and clock traces will reduce settling errors and crosstalk in precision acquisition paths.
Recommended
Balanced Differential Signal Routing
The DG409CUE+ is useful when two 4:1 sections must route positive and negative sides of a differential signal. Selecting corresponding channels on both multiplexers allows a differential source pair to reach downstream circuitry through matched analog paths. The improved channel matching of 8 ohms maximum and flatness of 9 ohms maximum support consistent behavior across the selected inputs, and operation up to ±20 V accommodates bipolar signals within the stated range. Care is required when the two sections do not switch simultaneously, because mismatched timing can create transient differential imbalance. Firmware or control logic should coordinate address and enable transitions, and PCB routing should maintain closely matched geometry for the paired channels.
Recommended
Recommended Products Summary
Engineering reference data for DG409CUE+ — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | DG409CUE |
|---|---|---|
| Brand | Maxim Integrated | Maxim Integrated |
| Package | 16-pin TSSOP | 16-pin TSSOP - same |
| Multiplexer Configuration | Dual 4:1 | Dual 4:1 |
| Number of Circuits | 2 circuits | 2 circuits |
| On-Resistance | 100 ohms maximum | 100 ohms maximum |
| Channel Matching | 8 ohms maximum | 8 ohms maximum |
| Flatness Over Signal Range | 9 ohms maximum | 9 ohms maximum |
| Single-Supply Operation | Up to +30 V | Up to +30 V |
| Dual-Supply Operation | Up to ±20 V | Up to ±20 V |
| ESD Protection | Greater than 2,000 V per MIL-STD-883 Method 2002 | Greater than 2,000 V per MIL-STD-883 Method 2002 |
| Technology | CMOS | CMOS |
Key Differentiators
- Two independent multiplexers in one package (vs DG409DY-T1-E3)
- Specified channel consistency for measurement routing (vs DG409DY-T1-E3)
- Broad analog operating range (vs DG409DY-T1-E3)
Design Notes
Route each analog terminal directly to its intended connector, sensor, or measurement circuit and keep the DG409CUE+ close to the selected circuitry. The device's maximum on-resistance is 100 ohms, so long PCB traces can become significant when the source impedance is high. Use a continuous ground plane, avoid splits beneath the TSSOP-16 footprint, and place supply bypassing close to the power pins. Keep the address and enable routes away from sensitive analog paths to reduce capacitive coupling during switching.
Coordinate address and enable timing when both multiplexer sections carry a differential signal. Changing only one section's selection can create a temporary voltage difference between the paired paths. Apply address and enable signals with suitable rise and fall times, and observe the device's control requirements in the Maxim Integrated DG409 datasheet. If the circuit samples immediately after a channel change, allow for the complete switching and settling interval rather than sampling in the transition region.
Do not treat the TSSOP-16 and SOIC-16 DG409 order codes as interchangeable land patterns. The Vishay DG409DY-T1-E3 listing identifies a 16-SOIC package, while the DG409CUE+ uses a 16-pin TSSOP footprint. In addition, confirm that the source impedance is high enough relative to the 100-ohm maximum on-resistance or compensate for the resulting attenuation. Finally, verify single- and dual-supply limits before applying bipolar signals.
Compliance Information
MIL-STD-883 Method 2002 ESD protection is specified, but no RoHS, REACH, lead-free, halogen-free, or conflict-minerals status is stated in the available product information.