Renesas Electronics

IDTCV123PV - 400MHz FlexPC Clock | Renesas | Legacy Systems

MPN: IDTCV123PV ✗ End of Life
3.135 V nominal reference; complete tolerance unavailable Vdss 56-pin BSSOP, 0.295 inch body width, 7.50 mm width Package 400 MHz Speed
MOQ: 1 |

IDTCV123PV Overview

The Renesas IDTCV123PV is a programmable FlexPC application-specific clock and timing IC with a maximum operating frequency of 400 MHz, supplied in a 56-pin BSSOP surface-mount package. It was designed for clock generation in legacy Intel P4 processor systems, where the processor required several coordinated reference clocks with precise frequency relationships. The device is identified as a single-circuit, crystal-input clock solution with a stated operating-temperature range of 0°C to 70°C.

An application-specific clock and timing IC is a specialized member of the clock and timing hierarchy. Unlike a general-purpose oscillator, it integrates the reference source, divider, phase, and distribution functions needed by a particular processor or system. In an Intel P4 platform, the IDTCV123PV supports the relationship between reference, bus, and peripheral clocks, making it more specialized than a basic crystal oscillator or a single-output clock generator.

The principal documented characteristics include a maximum frequency of 400 MHz, crystal input, one clock circuit, and surface-mount construction in a 56-BSSOP package. The device uses a 3.135 V nominal supply region, with the complete manufacturer operating range and tolerances requiring confirmation from the manufacturer datasheet. Its 0°C to 70°C operating range places it squarely in the commercial-temperature class rather than an industrial or automotive environment.

The IDTCV123PV uses a programmable architecture intended for FlexPC clock trees. Its value comes from reproducing the clock relationships expected by a specific processor platform rather than supplying one generic frequency. Because the device is obsolete, modern motherboard designs generally favor active clock generators with current-generation CPU support, newer I/O standards, smaller packages, and broader lifecycle coverage.

Legacy P4 workstation, server, and embedded industrial-control systems are the principal application areas. The same architecture can also support refurbished test equipment and embedded platforms that retain the original processor clock topology. Replacement work should begin by comparing pin assignments, reference-clock input requirements, output frequency, voltage, jitter, and enable sequencing rather than selecting a substitute from the package name alone.

When restoring a legacy design, use the manufacturer pin-description table and reference schematic to verify every net. Pay particular attention to crystal-loop components, termination, unused outputs, supply decoupling, and the relationship between the 400 MHz maximum specification and the actual operating clock. Do not assume that a generic 400 MHz oscillator is interchangeable because clock phase and edge relationships may differ materially.

This page organizes the documented operating facts, legacy-use considerations, sourcing path, and drop-in-replacement status for IDTCV123PV. It also distinguishes a documented obsolete part from currently active equivalents and highlights the electrical and platform checks that matter most when maintaining an existing P4-era design.

Drop-in alternatives for IDTCV123PV — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

No drop-in alternatives available for this product.

Request Alternatives

IDTCV123PV Specifications

Product Type Programmable FlexPC application-specific clock and timing IC
Manufacturer Renesas Electronics
Maximum Operating Frequency 400 MHz
Clock Circuit Count 1 circuit
Input Type Crystal input
Output Type Clock output
Primary Application Intel P4 processor clock generation
Mounting Type Surface mount
Package 56-pin BSSOP, 0.295 inch body width, 7.50 mm width
Operating Temperature 0°C to 70°C
Nominal Supply Voltage 3.135 V nominal reference; complete tolerance unavailable
Moisture Sensitivity Level MSL 1, unlimited floor-life exposure
Packaging Tube
Series FlexPC
Lifecycle Status Obsolete
AEC-Q100 Qualification Not applicable; commercial-temperature clock IC

IDTCV123PV 56-pin bssop, 0.295 inch body width, 7.50 mm width Pin Configuration Guide

Pin configuration for IDTCV123PV (56-pin bssop, 0.295 inch body width, 7.50 mm width package). Pin numbering, functions, and connection diagrams are defined in the manufacturer datasheet. Refer to it for the exact footprint and soldering guidelines.

56-pin bssop, 0.295 inch body width, 7.50 mm width package pinout diagram for IDTCV123PV

No detailed pinout data available for IDTCV123PV.

Refer to the datasheet for full pin configuration.

Typical Applications

IDTCV123PV is suitable for 6 applications: Legacy Intel P4 Workstations, P4 Server Platform Restoration, Refurbished Industrial Control Systems, Legacy Test and Measurement Equipment, Refurbished Communications Equipment, Embedded P4 Controller Maintenance.

🖥️

Legacy Intel P4 Workstations

The IDTCV123PV fits a legacy Intel P4 workstation only when the original platform requires its programmable FlexPC clock relationships. Its 400 MHz maximum frequency, crystal input, and single-clock-circuit architecture match the device's documented P4 role. During a board repair, preserve the original configuration and verify each clock relationship against the manufacturer timing tables. A substitute clock must reproduce the pinout, load requirements, phase, and supply behavior rather than provide only the same headline frequency.

🖥️

P4 Server Platform Restoration

In a P4 server restoration, the IDTCV123PV can be used to reproduce the original clock-generation topology on a board whose schematics identify this exact device. Its 400 MHz maximum rating and programmable FlexPC architecture suit legacy processor clock trees, while the 0°C to 70°C range matches commercial-class operating environments. Before installation, compare the crystal network, output loads, configuration straps, and timing relationships with the system documentation. Consider a modern clock generator only for a deliberate redesign, not as an assumed drop-in replacement.

🏭

Refurbished Industrial Control Systems

The IDTCV123PV may support maintenance of a refurbished industrial control system that retains an original Intel P4 clock section. The commercial 0°C to 70°C specification should be checked against the cabinet's actual ambient range and enclosure temperature. Because the part is obsolete, replacement planning should include traceability and long-term availability. Use the manufacturer configuration information to confirm crystal loading and clock phasing, and validate the complete processor bus with the system timing requirements after repair.

🔧

Legacy Test and Measurement Equipment

For test and measurement equipment built around an Intel P4 platform, the IDTCV123PV can serve as the original application-specific clock when its configuration and pin functions are required. The 56-pin BSSOP package and one-clock-circuit organization make board-level restoration more demanding than replacing a simple oscillator. Confirm clock amplitudes, duty cycle, phase relationships, and configuration pins with the manufacturer documentation. Post-repair testing should include the reference clock, processor clock, and downstream peripheral timing rather than checking only frequency at one output.

🌐

Refurbished Communications Equipment

The IDTCV123PV is suitable for maintaining a legacy communications appliance only where the original Intel P4 clock tree specifically calls for this programmable device. Its 400 MHz maximum frequency supports the documented clocking role, but the single circuit means output capability must be checked output by output. Verify connector and interface timing through the original system schematics rather than assuming every peripheral shares the same clock phase. A modern clock generator may simplify a redesign, but changing the device can affect margins across several interfaces.

🧩

Embedded P4 Controller Maintenance

An embedded controller that retains an Intel P4 processor can use the IDTCV123PV for exact legacy platform maintenance. The device's programmable FlexPC architecture provides application-specific clocking rather than a simple fixed frequency, while the 56-pin BSSOP package reflects the original design generation. For long-lived equipment, document the crystal, timing configuration, and operating environment so future repairs remain repeatable. Because the clock is obsolete and rated only from 0°C to 70°C, a modern controller architecture is preferable when the system can be redesigned.

What is the IDTCV123PV?
The IDTCV123PV is a Renesas programmable FlexPC application-specific clock and timing IC designed for Intel P4 processor systems. According to the manufacturer datasheet, it uses a crystal input, provides one clock circuit, supports frequencies up to 400 MHz, and is packaged in a 56-pin BSSOP. Its specialized clock tree makes it more appropriate for legacy P4 platforms than a generic single-output oscillator.
What are the key specifications of IDTCV123PV that engineers should know?
The key IDTCV123PV specifications are a 400 MHz maximum operating frequency, one clock circuit, crystal input, a 56-pin BSSOP package, and a 0°C to 70°C operating range. The device is identified as a FlexPC part for Intel P4 processor clock generation. According to the manufacturer datasheet, mounting is by surface mount and the documented moisture sensitivity level is MSL 1. Its obsolete lifecycle status is the most important sourcing constraint.
Is IDTCV123PV still active?
No, the IDTCV123PV is listed as obsolete. The manufacturer-related product information identifies the part as obsolete or end-of-life, and it was designed around the Intel P4 processor generation. For a new design, select a currently supported clock generator rather than basing the architecture on a legacy application-specific clock. For an existing P4 system, use the Request a Quote form on this page to request availability and sourcing assistance.
Where can I find the IDTCV123PV pinout and datasheet PDF?
The IDTCV123PV datasheet and pin information are available through the linked manufacturer datasheet entry and its Octopart PDF page. The device uses a 56-pin BSSOP package, but the exact pin names and numbering are not reproduced here. Use the manufacturer pin-description table when assigning PCB nets, especially for power, crystal inputs, clock outputs, configuration straps, and unused pins.
What package does IDTCV123PV use?
The IDTCV123PV is supplied in a 56-pin BSSOP surface-mount package with a stated body width of 0.295 inch, equivalent to 7.50 mm. It is supplied in a tube for production handling. Because the exact 56-pin BSSOP drawing is not in the available package library, use a generic 56-pin BSSOP footprint only after checking its dimensions, lead pitch, pin-one orientation, and land pattern against the manufacturer package drawing.
What is the operating temperature range of IDTCV123PV?
The IDTCV123PV operates from 0°C to 70°C. According to the manufacturer product information, this places the device in the commercial-temperature range and limits its suitability for uncased industrial, automotive, or extended-temperature environments without additional qualification. If the original system operated outside 0°C to 70°C, choose a replacement with a wider specified range and review oscillator drift, clock accuracy, and load-capacitance requirements.
Can IDTCV123PV be used in a modern Intel processor system?
The IDTCV123PV is intended for legacy Intel P4 processor clock generation and should not be assumed suitable for a modern CPU platform. The manufacturer describes it as a programmable FlexPC clock for the P4 processor, and its obsolete status reflects its legacy role. Modern platforms can require different reference sources, differential clocks, larger I/O voltages, tighter phase relationships, and different enable sequencing that this device does not provide.
What is the maximum frequency of IDTCV123PV?
The maximum operating frequency of the IDTCV123PV is 400 MHz. This figure describes the device capability and does not mean every output can be operated simultaneously at 400 MHz. According to the manufacturer datasheet, the part includes one clock circuit and programmable FlexPC functions, so the correct operating points and frequency relationships must be taken from the configuration tables before assigning outputs in a reference design.
What is the best drop-in replacement for IDTCV123PV?
No verified pin-to-pin drop-in replacement for the IDTCV123PV was identified in the available cross-reference results. A valid replacement must match the 56-pin BSSOP footprint, crystal interface, supply voltage, frequency range, output phase relationships, and configuration method. Use the Request a Quote form on this page for a targeted replacement search, and do not substitute a generic 400 MHz oscillator without a complete timing and pin-level review.
Can a generic 400 MHz oscillator replace IDTCV123PV?
A generic 400 MHz oscillator is not automatically a drop-in replacement for the IDTCV123PV. Although the clock and timing function is similar at a high level, the IDTCV123PV is an application-specific FlexPC device with one clock circuit, a crystal input, a 56-pin BSSOP package, and specific programmed frequency relationships. A replacement also needs matching electrical loading, phase, jitter, configuration, and pin functions.
IDTCV123PV versus a modern programmable clock generator: which should I choose?
Choose the IDTCV123PV only when repairing a system whose original schematic, bill of materials, and processor platform explicitly require it. Choose a modern programmable clock generator for new designs because current devices generally offer smaller packages, wider logic support, better lifecycle status, and broader platform features. The choice therefore depends on board compatibility and legacy requirements rather than simply comparing the 400 MHz headline frequency.
When should I choose IDTCV123PV over another clock IC?
Choose the IDTCV123PV when maintaining an original Intel P4-based system and the exact legacy timing topology, pin assignment, and configuration method must be preserved. Do not choose it for a new platform or an expanded-temperature installation. If the board has been substantially redesigned, a modern programmable clock generator may provide a smaller footprint and broader sourcing options, but it will require circuit and validation changes.
What should I check when replacing IDTCV123PV?
Check the 56-pin BSSOP footprint, supply-voltage limits, crystal frequency and load capacitance, output frequency, duty cycle, phase, jitter, enable polarity, configuration method, and unused-pin treatment. According to the manufacturer documentation, IDTCV123PV is a one-circuit FlexPC clock intended for P4 systems. These checks are essential because a generic clock generator with the same nominal frequency may not preserve the original platform timing.
Where can I buy IDTCV123PV and what is its price?
Use the Request a Quote form on this page to request current IDTCV123PV availability, price, and lead time for the exact obsolete MPN. The part is listed as obsolete, so availability may depend on legacy inventory and original packaging traceability. Include the target quantity, required package suffix, tube-packaging preference, and date-code requirements with the request so obsolete sourcing can be assessed accurately.
Is IDTCV123PV in stock and what is the lead time?
Stock and lead time for the obsolete IDTCV123PV should be requested through the Request a Quote form on this page. The product information identifies the device as obsolete, so current inventory cannot be inferred from historical catalog availability. A sourcing review should confirm the exact MPN, tube packaging, operating-temperature marking, quantity, and any date-code restrictions before an order is placed.

Engineering reference data for IDTCV123PV — comparison, design guidance, and compliance information.

Selection Guide

Choose IDTCV123PV when repairing an existing Intel P4 platform whose original bill of materials, schematic, and pin configuration specifically identify this clock IC. Its 400 MHz maximum frequency, crystal input, and application-specific FlexPC functions make it preferable to assuming a generic oscillator can preserve the original timing tree. For a new design, choose a currently supported programmable clock generator with the required output count, voltage, phase, jitter, and platform features. For embedded or communications equipment, verify that the original enclosure remains within the device's 0°C to 70°C operating range. No verified drop-in replacement was identified, so any redesign should treat pinout, configuration, crystal loading, and downstream timing as explicit validation items.

Comparison with Alternatives

Parameter This Product
Brand Renesas Electronics
Package 56-pin BSSOP
Maximum Frequency 400 MHz
Clock Circuit Count 1 circuit
Input Type Crystal input
Mounting Type Surface mount
Operating Temperature 0°C to 70°C
Lifecycle Status Obsolete
Primary Application Intel P4 processor clock generation

Key Differentiators

  • Application-specific FlexPC clock architecture (vs Generic 400 MHz oscillator)
  • Established legacy P4 platform role (vs Modern programmable clock generator)
  • Documented commercial operating range (vs Extended-temperature clock generator)

Design Notes

Do not substitute a generic oscillator solely because it has the same nominal frequency. The IDTCV123PV is an application-specific FlexPC clock with one clock circuit, a crystal input, configuration functions, and platform-specific timing relationships. Before replacement, compare every pin, the crystal load network, output phase, duty cycle, voltage, and enable behavior against the manufacturer documentation. A frequency match alone does not establish drop-in compatibility.

Use the manufacturer package drawing to verify the 56-pin BSSOP land pattern, lead pitch, pin-one orientation, and body clearance. The legacy package is not represented by a specific canonical package-diagram key in the available library. Do not adapt a generic footprint without checking pad dimensions and solder mask geometry. Also inspect whether a replacement requires board-side crystal or load-capacitor changes before attempting a repair.

Preserve the original clock topology, output loading, and configuration method when restoring an IDTCV123PV-based board. The 400 MHz maximum frequency is a device limit, not permission to operate every output at that rate without checking the timing tables. Probe the crystal circuit and each relevant clock output with suitable bandwidth, then verify edge quality, duty cycle, and phase relationships at the operating load.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

The documented temperature grade is commercial, so AEC-Q100 qualification does not apply. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from current manufacturer documentation.

Data verified on: 2026-11-21 — data verified and curated by XAIPART's component engineering team

Related Searches

IDTCV123PV datasheet IDTCV123PV pinout IDTCV123PV datasheet pdf IDTCV123PV equivalent IDTCV123PV replacement IDTCV123PV cross reference Renesas IDTCV123PV IDTCV123PV 400MHz clock IDTCV123PV 56-BSSOP IDTCV123PV P4 clock IDTCV123PV price IDTCV123PV stock IDTCV123PV obsolete replacement IDTCV123PV FlexPC schematic IDTCV123PV footprint

Related Components & Terms

Renesas Electronics IDTCV123PV FlexPC application-specific clock and timing IC clock and timing IC programmable clock legacy clock generator Intel P4 processor 400 MHz crystal input clock output 56-pin BSSOP surface-mount package MSL 1 RoHS REACH AEC-Q100 commercial temperature grade clock jitter clock phase obsolete component drop-in replacement semiconductor
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details