IDTCV123PV - 400MHz FlexPC Clock | Renesas | Legacy Systems
MPN: IDTCV123PV ✗ जीवन की समाप्तिIDTCV123PV अवलोकन
An application-specific clock and timing IC is a specialized member of the clock and timing hierarchy. Unlike a general-purpose oscillator, it integrates the reference source, divider, phase, and distribution functions needed by a particular processor or system. In an Intel P4 platform, the IDTCV123PV supports the relationship between reference, bus, and peripheral clocks, making it more specialized than a basic crystal oscillator or a single-output clock generator.
The principal documented characteristics include a maximum frequency of 400 MHz, crystal input, one clock circuit, and surface-mount construction in a 56-BSSOP package. The device uses a 3.135 V nominal supply region, with the complete manufacturer operating range and tolerances requiring confirmation from the manufacturer datasheet. Its 0°C to 70°C operating range places it squarely in the commercial-temperature class rather than an industrial or automotive environment.
The IDTCV123PV uses a programmable architecture intended for FlexPC clock trees. Its value comes from reproducing the clock relationships expected by a specific processor platform rather than supplying one generic frequency. Because the device is obsolete, modern motherboard designs generally favor active clock generators with current-generation CPU support, newer I/O standards, smaller packages, and broader lifecycle coverage.
Legacy P4 workstation, server, and embedded industrial-control systems are the principal application areas. The same architecture can also support refurbished test equipment and embedded platforms that retain the original processor clock topology. Replacement work should begin by comparing pin assignments, reference-clock input requirements, output frequency, voltage, jitter, and enable sequencing rather than selecting a substitute from the package name alone.
When restoring a legacy design, use the manufacturer pin-description table and reference schematic to verify every net. Pay particular attention to crystal-loop components, termination, unused outputs, supply decoupling, and the relationship between the 400 MHz maximum specification and the actual operating clock. Do not assume that a generic 400 MHz oscillator is interchangeable because clock phase and edge relationships may differ materially.
This page organizes the documented operating facts, legacy-use considerations, sourcing path, and drop-in-replacement status for IDTCV123PV. It also distinguishes a documented obsolete part from currently active equivalents and highlights the electrical and platform checks that matter most when maintaining an existing P4-era design.
के लिए ड्रॉप-इन विकल्प IDTCV123PV — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।
इस उत्पाद के लिए कोई drop-in alternatives उपलब्ध नहीं।
विकल्प अनुरोध करेंIDTCV123PV विशेषताएं
| Product Type | Programmable FlexPC application-specific clock and timing IC |
| Manufacturer | Renesas Electronics |
| Maximum Operating Frequency | 400 MHz |
| Clock Circuit Count | 1 circuit |
| Input Type | Crystal input |
| आउटपुट प्रकार | Clock output |
| Primary Application | Intel P4 processor clock generation |
| माउंटिंग प्रकार | Surface mount |
| पैकेज | 56-pin BSSOP, 0.295 inch body width, 7.50 mm width |
| ऑपरेटिंग तापमान | 0°C to 70°C |
| Nominal Supply Voltage | 3.135 V nominal reference; complete tolerance unavailable |
| Moisture Sensitivity Level | MSL 1, unlimited floor-life exposure |
| Packaging | Tube |
| Series | FlexPC |
| लाइफसाइकिल स्थिति | Obsolete |
| AEC-Q100 Qualification | Not applicable; commercial-temperature clock IC |
IDTCV123PV 56-pin bssop, 0.295 inch body width, 7.50 mm width पिन कॉन्फ़िगरेशन गाइड
IDTCV123PV (56-pin bssop, 0.295 inch body width, 7.50 mm width पैकेज) के लिए पिन कॉन्फ़िगरेशन। पिन नंबरिंग, फ़ंक्शन और कनेक्शन आरेख निर्माता डेटाशीट में परिभाषित हैं। सटीक फुटप्रिंट और सोल्डरिंग दिशानिर्देशों के लिए इसे देखें।
इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: IDTCV123PV.
देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।
सामान्य अनुप्रयोग
IDTCV123PV के लिए उपयुक्त है 6 अनुप्रयोगs: Legacy Intel P4 Workstations, P4 Server Platform Restoration, Refurbished Industrial Control Systems, Legacy Test and Measurement Equipment, Refurbished Communications Equipment, Embedded P4 Controller Maintenance.
Legacy Intel P4 Workstations
The IDTCV123PV fits a legacy Intel P4 workstation only when the original platform requires its programmable FlexPC clock relationships. Its 400 MHz maximum frequency, crystal input, and single-clock-circuit architecture match the device's documented P4 role. During a board repair, preserve the original configuration and verify each clock relationship against the manufacturer timing tables. A substitute clock must reproduce the pinout, load requirements, phase, and supply behavior rather than provide only the same headline frequency.
अनुशंसित
P4 Server Platform Restoration
In a P4 server restoration, the IDTCV123PV can be used to reproduce the original clock-generation topology on a board whose schematics identify this exact device. Its 400 MHz maximum rating and programmable FlexPC architecture suit legacy processor clock trees, while the 0°C to 70°C range matches commercial-class operating environments. Before installation, compare the crystal network, output loads, configuration straps, and timing relationships with the system documentation. Consider a modern clock generator only for a deliberate redesign, not as an assumed drop-in replacement.
अनुशंसित
Refurbished Industrial Control Systems
The IDTCV123PV may support maintenance of a refurbished industrial control system that retains an original Intel P4 clock section. The commercial 0°C to 70°C specification should be checked against the cabinet's actual ambient range and enclosure temperature. Because the part is obsolete, replacement planning should include traceability and long-term availability. Use the manufacturer configuration information to confirm crystal loading and clock phasing, and validate the complete processor bus with the system timing requirements after repair.
अनुशंसित
Legacy Test and Measurement Equipment
For test and measurement equipment built around an Intel P4 platform, the IDTCV123PV can serve as the original application-specific clock when its configuration and pin functions are required. The 56-pin BSSOP package and one-clock-circuit organization make board-level restoration more demanding than replacing a simple oscillator. Confirm clock amplitudes, duty cycle, phase relationships, and configuration pins with the manufacturer documentation. Post-repair testing should include the reference clock, processor clock, and downstream peripheral timing rather than checking only frequency at one output.
अनुशंसित
Refurbished Communications Equipment
The IDTCV123PV is suitable for maintaining a legacy communications appliance only where the original Intel P4 clock tree specifically calls for this programmable device. Its 400 MHz maximum frequency supports the documented clocking role, but the single circuit means output capability must be checked output by output. Verify connector and interface timing through the original system schematics rather than assuming every peripheral shares the same clock phase. A modern clock generator may simplify a redesign, but changing the device can affect margins across several interfaces.
अनुशंसित
Embedded P4 Controller Maintenance
An embedded controller that retains an Intel P4 processor can use the IDTCV123PV for exact legacy platform maintenance. The device's programmable FlexPC architecture provides application-specific clocking rather than a simple fixed frequency, while the 56-pin BSSOP package reflects the original design generation. For long-lived equipment, document the crystal, timing configuration, and operating environment so future repairs remain repeatable. Because the clock is obsolete and rated only from 0°C to 70°C, a modern controller architecture is preferable when the system can be redesigned.
अनुशंसित
के लिए इंजीनियरिंग संदर्भ डेटा IDTCV123PV — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।
चयन गाइड
विकल्पों के साथ तुलना
| पैरामीटर | यह उत्पाद |
|---|---|
| Brand | Renesas Electronics |
| Package | 56-pin BSSOP |
| Maximum Frequency | 400 MHz |
| Clock Circuit Count | 1 circuit |
| Input Type | Crystal input |
| Mounting Type | Surface mount |
| Operating Temperature | 0°C to 70°C |
| Lifecycle Status | Obsolete |
| Primary Application | Intel P4 processor clock generation |
मुख्य विशेषताएँ
- Application-specific FlexPC clock architecture (बनामGeneric 400 MHz oscillator)
- Established legacy P4 platform role (बनामModern programmable clock generator)
- Documented commercial operating range (बनामExtended-temperature clock generator)
डिज़ाइन नोट्स
Do not substitute a generic oscillator solely because it has the same nominal frequency. The IDTCV123PV is an application-specific FlexPC clock with one clock circuit, a crystal input, configuration functions, and platform-specific timing relationships. Before replacement, compare every pin, the crystal load network, output phase, duty cycle, voltage, and enable behavior against the manufacturer documentation. A frequency match alone does not establish drop-in compatibility.
Use the manufacturer package drawing to verify the 56-pin BSSOP land pattern, lead pitch, pin-one orientation, and body clearance. The legacy package is not represented by a specific canonical package-diagram key in the available library. Do not adapt a generic footprint without checking pad dimensions and solder mask geometry. Also inspect whether a replacement requires board-side crystal or load-capacitor changes before attempting a repair.
Preserve the original clock topology, output loading, and configuration method when restoring an IDTCV123PV-based board. The 400 MHz maximum frequency is a device limit, not permission to operate every output at that rate without checking the timing tables. Probe the crystal circuit and each relevant clock output with suitable bandwidth, then verify edge quality, duty cycle, and phase relationships at the operating load.
अनुपालन जानकारी
The documented temperature grade is commercial, so AEC-Q100 qualification does not apply. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from current manufacturer documentation.