INA111BUG4 - 2MHz FET-Input Instrumentation Amp | Texas Instruments
MPN: INA111BUG4 ✓ ActiveINA111BUG4 Overview
An instrumentation amplifier is a specialized analog amplifier that measures the voltage difference between two inputs while rejecting common-mode interference. The INA111 belongs to the FET-input instrumentation amplifier hierarchy, combining an instrumentation amplifier with low-bias-current transistor input circuitry. This topology supports accurate measurement from sources that would disturb conventional bipolar-input amplifiers.
The INA111’s principal advantages include input bias current below 20 pA, operation across a -40°C to +85°C temperature range, and a 2 MHz gain-bandwidth product. Its FET inputs also reduce input loading, simplify input filtering, and make the device suitable for bridge, transducer, and current-sense measurements where source impedances range from approximately 2 kΩ to 50 kΩ. The SOIC-16 surface-mount package supports compact analog instrumentation.
The three-op-amp instrumentation-amplifier architecture provides a practical balance between common-mode rejection, gain control, input impedance, and signal bandwidth. Gain is established externally, allowing one device to support multiple measurement ranges without changing its internal signal path. As with any precision amplifier, the useful bandwidth decreases as the selected gain increases, so the complete gain-versus-bandwidth characteristic must be considered in high-speed designs.
Typical uses include bridge-transducer excitation and readout, precision current sensing, laboratory measurement interfaces, medical instrumentation, and low-level differential signal acquisition. The high input impedance is particularly useful when the source is a sensor or resistive network whose output impedance is much higher than the amplifier input resistance. The device can therefore preserve source amplitude and reduce loading errors.
For reliable operation, place the external gain-setting resistor and compensation network close to the device, keep input and feedback traces short, and use a quiet, low-impedance supply. Decoupling capacitors should be positioned directly beside the supply pins, while analog and digital ground returns should follow the manufacturer’s recommended layout and grounding arrangement.
This product page combines the manufacturer’s INA111 documentation with application guidance, package information, verified source links, and replacement considerations. It is intended to help engineers identify suitable signal-chain applications, evaluate package and lifecycle constraints, and determine whether an existing PCB footprint can be reused without changing the analog layout.
Drop-in alternatives for INA111BUG4 — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
No drop-in alternatives available for this product.
Request AlternativesINA111BUG4 Maximum Ratings & Electrical Characteristics
| Product Type | High-speed FET-input instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Gain-Bandwidth Product | 2 MHz |
| Input Bias Current | Less than 20 pA |
| Input Transistor Type | FET input |
| Package | 16-pin SOIC |
| Mounting Type | Surface mount |
| Operating Temperature Range | -40°C to +85°C |
| Recommended Source Impedance Range | 2 kΩ to 50 kΩ |
INA111BUG4 16-pin soic Pin Configuration Guide
Pin configuration for INA111BUG4 (16-pin soic package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.
No detailed pinout data available for INA111BUG4.
Refer to the datasheet for full pin configuration.
Typical Applications
INA111BUG4 is suitable for 6 applications: Bridge Transducer Signal Conditioning, Precision Current Sensing, Medical Instrumentation, Laboratory Data Acquisition, Industrial Sensor Interface, Audio and Low-Level Differential Sensing.
Bridge Transducer Signal Conditioning
The INA111BUG4 is well suited to bridge-transducer readout because its FET inputs draw less than 20 pA of bias current, reducing loading on high-impedance sensing networks. Its instrumentation-amplifier architecture measures the differential bridge excitation while rejecting common-mode voltage, and the 2 MHz gain-bandwidth product supports fast settling in measurement systems. Place the device near the bridge outputs, use the manufacturer’s gain-setting arrangement, and provide local supply bypassing. The main design trade-off is that closed-loop bandwidth decreases as gain increases, so the required transducer response and settling accuracy must be checked together.
Recommended
Precision Current Sensing
The INA111BUG4 can amplify the small differential voltage produced by a current-sense element when the required bandwidth is higher than that of a precision-only amplifier. Its input bias current below 20 pA minimizes the error introduced through high-impedance sensing paths, while the 2 MHz gain-bandwidth product supports rapid response. Place the gain-setting resistor close to the amplifier, route the sense traces as a differential pair, and keep them away from switching nodes. Designers must also verify common-mode limits, output swing, and amplifier settling against the current waveform and system response requirement.
Recommended
Medical Instrumentation
The INA111BUG4 is appropriate for low-level biomedical signal acquisition when the circuit requires low input bias current and high-speed differential amplification. Its less-than-20 pA input bias current helps avoid disturbing high-source-impedance sensors, and the instrumentation-amplifier topology supports rejection of common-mode interference coupled into patient or electrode wiring. The system designer must still account for patient-safety isolation, leakage, protection networks, diagnostic noise requirements, and applicable medical standards. Use only manufacturer-approved protection methods and validate the complete analog chain rather than relying on the amplifier alone.
Recommended
Laboratory Data Acquisition
The INA111BUG4 supports laboratory data-acquisition front ends that need to measure small differential voltages without excessive source loading. Its 2 MHz gain-bandwidth product provides useful signal speed, while input bias current below 20 pA is valuable when connecting probes, sensors, or resistive networks with relatively high impedance. Place the amplifier close to the source to minimize noise pickup, use shielded or differential routing, and decouple the supply pins locally. The selected closed-loop gain must remain compatible with the available bandwidth, and the complete acquisition chain should be characterized for offset, drift, settling, and common-mode rejection.
Recommended
Industrial Sensor Interface
The INA111BUG4 can condition low-level differential outputs from resistive industrial sensors where low input current and moderate signal speed are required. Its FET input stage reduces loading on high-impedance dividers or sensing elements, and the 2 MHz gain-bandwidth product is useful for relatively fast process-control signals. Place the device near the sensor connector, keep the differential route compact, and separate sensitive analog traces from motor, relay, and power-converter switching paths. Production designs should verify the sensor excitation range, amplifier supply limits, common-mode range, calibration stability, and environmental requirements for the target installation.
Recommended
Audio and Low-Level Differential Sensing
The INA111BUG4 can be evaluated for audio or other balanced low-level differential sensing when the design benefits from fast signal acquisition and minimal source loading. Its less-than-20 pA input bias current reduces interaction with high-impedance sources, while the instrumentation-amplifier configuration rejects common-mode signals present on balanced lines. The amplifier should be positioned near the connector or source, with balanced routing and a quiet reference plane to preserve signal integrity. Engineers must verify the required gain, input and output swing, noise performance, bandwidth, and whether the target source impedance lies within the manufacturer’s recommended range.
Recommended
Recommended Products Summary
Engineering reference data for INA111BUG4 — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product |
|---|---|
| Package | 16-pin SOIC |
| Brand | Texas Instruments |
| Product Type | High-speed FET-input instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Gain-Bandwidth Product | 2 MHz |
| Input Bias Current | Less than 20 pA |
| Input Transistor Type | FET input |
| Operating Temperature Range | -40°C to +85°C |
| Recommended Source Impedance Range | 2 kΩ to 50 kΩ |
| Mounting Type | Surface mount |
Key Differentiators
- High-speed signal conditioning (vs INA114)
- Minimal interaction with high-impedance sources (vs INA117KU)
- FET-input instrumentation-amplifier architecture (vs INA118UB)
Design Notes
Place the INA111BUG4 close to the input source and connect the differential inputs with matched, tightly coupled routing. The external gain-setting component and any compensation network should also be positioned close to the amplifier to minimize parasitic resistance and inductance. Keep the SOIC ground connection continuous and use a quiet analog ground strategy; long input loops can increase noise pickup and make common-mode rejection less predictable.
Connect the bypass capacitors directly between the supply pins and their designated return pins, with the shortest possible traces. The 2 MHz gain-bandwidth product means that supply decoupling and printed-circuit-board return paths can materially affect high-frequency behavior. Use the recommended capacitor type and value from the manufacturer application circuit, and avoid placing noisy switching-regulator nodes or high-current return paths beneath the sensitive input and feedback components.
Do not select the closed-loop gain without checking the corresponding bandwidth and settling behavior. Available bandwidth decreases as gain rises, and a circuit that meets its noise requirement may not settle within the measurement window. Use the gain-versus-frequency curves and external-component guidance in the Texas Instruments manufacturer datasheet, then validate the worst-case combination of gain, source impedance, temperature, supply variation, and output load.
A common design error is assuming that the SOIC-16 footprint alone proves replacement compatibility. Pin functions, gain-setting networks, supply limits, input common-mode range, output swing, compensation requirements, and package dimensions must also match. The available cross-reference results identify comparison candidates but do not establish five verified pin-to-pin substitutes. Therefore, treat INA118UB and INA117KU as evaluation leads and verify them against the original design before PCB reuse.
Compliance Information
The manufacturer documentation identifies the INA111 as an active product, but explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations are not present in the referenced source material.