Less than 20 pA Id 16-pin SOIC Package
الحد الأدنى للطلب: 1 |

INA111BUG4 نظرة عامة

The Texas Instruments INA111BUG4 is a high-speed, FET-input instrumentation amplifier with a gain-bandwidth product of 2 MHz, packaged in a 16-pin SOIC. It is designed for precision signal-conditioning applications that require amplification of low-level differential signals, particularly when the source impedance is high and input bias current must remain small.

An instrumentation amplifier is a specialized analog amplifier that measures the voltage difference between two inputs while rejecting common-mode interference. The INA111 belongs to the FET-input instrumentation amplifier hierarchy, combining an instrumentation amplifier with low-bias-current transistor input circuitry. This topology supports accurate measurement from sources that would disturb conventional bipolar-input amplifiers.

The INA111’s principal advantages include input bias current below 20 pA, operation across a -40°C to +85°C temperature range, and a 2 MHz gain-bandwidth product. Its FET inputs also reduce input loading, simplify input filtering, and make the device suitable for bridge, transducer, and current-sense measurements where source impedances range from approximately 2 kΩ to 50 kΩ. The SOIC-16 surface-mount package supports compact analog instrumentation.

The three-op-amp instrumentation-amplifier architecture provides a practical balance between common-mode rejection, gain control, input impedance, and signal bandwidth. Gain is established externally, allowing one device to support multiple measurement ranges without changing its internal signal path. As with any precision amplifier, the useful bandwidth decreases as the selected gain increases, so the complete gain-versus-bandwidth characteristic must be considered in high-speed designs.

Typical uses include bridge-transducer excitation and readout, precision current sensing, laboratory measurement interfaces, medical instrumentation, and low-level differential signal acquisition. The high input impedance is particularly useful when the source is a sensor or resistive network whose output impedance is much higher than the amplifier input resistance. The device can therefore preserve source amplitude and reduce loading errors.

For reliable operation, place the external gain-setting resistor and compensation network close to the device, keep input and feedback traces short, and use a quiet, low-impedance supply. Decoupling capacitors should be positioned directly beside the supply pins, while analog and digital ground returns should follow the manufacturer’s recommended layout and grounding arrangement.

This product page combines the manufacturer’s INA111 documentation with application guidance, package information, verified source links, and replacement considerations. It is intended to help engineers identify suitable signal-chain applications, evaluate package and lifecycle constraints, and determine whether an existing PCB footprint can be reused without changing the analog layout.

بدائل مباشرة لـ INA111BUG4 — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.

لا تتوفر بدائل متوافقة تمامًا لهذا المنتج.

اطلب بدائل

INA111BUG4 الحدود القصوى والخصائص الكهربائية

Product Type High-speed FET-input instrumentation amplifier
Number of Circuits 1 circuit
Gain-Bandwidth Product 2 MHz
Input Bias Current Less than 20 pA
Input Transistor Type FET input
العلبة 16-pin SOIC
نوع التركيب Surface mount
نطاق درجة حرارة التشغيل -40°C to +85°C
Recommended Source Impedance Range 2 kΩ to 50 kΩ

دليل تكوين أطراف INA111BUG4 16-pin soic

تكوين الأطراف لـ INA111BUG4 (حزمة 16-pin soic). يتميز هذا المكوّن التناظري بأطراف الإدخال والإخراج وإمداد الطاقة. راجع ورقة بيانات الشركة المصنعة لتكوينات طرف إلغاء الإزاحة والتعويض والتمكين. مثالي لدوائر تكييف الإشارة والمضخمات.

مخطط توزيع أطراف حزمة 16-pin soic لـ INA111BUG4

لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ INA111BUG4.

راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.

التطبيقات النموذجية

INA111BUG4 مناسب لـ 6 التطبيقs: Bridge Transducer Signal Conditioning, Precision Current Sensing, Medical Instrumentation, Laboratory Data Acquisition, Industrial Sensor Interface, Audio and Low-Level Differential Sensing.

⚡

Bridge Transducer Signal Conditioning

The INA111BUG4 is well suited to bridge-transducer readout because its FET inputs draw less than 20 pA of bias current, reducing loading on high-impedance sensing networks. Its instrumentation-amplifier architecture measures the differential bridge excitation while rejecting common-mode voltage, and the 2 MHz gain-bandwidth product supports fast settling in measurement systems. Place the device near the bridge outputs, use the manufacturer’s gain-setting arrangement, and provide local supply bypassing. The main design trade-off is that closed-loop bandwidth decreases as gain increases, so the required transducer response and settling accuracy must be checked together.

🔧

Precision Current Sensing

The INA111BUG4 can amplify the small differential voltage produced by a current-sense element when the required bandwidth is higher than that of a precision-only amplifier. Its input bias current below 20 pA minimizes the error introduced through high-impedance sensing paths, while the 2 MHz gain-bandwidth product supports rapid response. Place the gain-setting resistor close to the amplifier, route the sense traces as a differential pair, and keep them away from switching nodes. Designers must also verify common-mode limits, output swing, and amplifier settling against the current waveform and system response requirement.

💊

Medical Instrumentation

The INA111BUG4 is appropriate for low-level biomedical signal acquisition when the circuit requires low input bias current and high-speed differential amplification. Its less-than-20 pA input bias current helps avoid disturbing high-source-impedance sensors, and the instrumentation-amplifier topology supports rejection of common-mode interference coupled into patient or electrode wiring. The system designer must still account for patient-safety isolation, leakage, protection networks, diagnostic noise requirements, and applicable medical standards. Use only manufacturer-approved protection methods and validate the complete analog chain rather than relying on the amplifier alone.

🖥️

Laboratory Data Acquisition

The INA111BUG4 supports laboratory data-acquisition front ends that need to measure small differential voltages without excessive source loading. Its 2 MHz gain-bandwidth product provides useful signal speed, while input bias current below 20 pA is valuable when connecting probes, sensors, or resistive networks with relatively high impedance. Place the amplifier close to the source to minimize noise pickup, use shielded or differential routing, and decouple the supply pins locally. The selected closed-loop gain must remain compatible with the available bandwidth, and the complete acquisition chain should be characterized for offset, drift, settling, and common-mode rejection.

🏭

Industrial Sensor Interface

The INA111BUG4 can condition low-level differential outputs from resistive industrial sensors where low input current and moderate signal speed are required. Its FET input stage reduces loading on high-impedance dividers or sensing elements, and the 2 MHz gain-bandwidth product is useful for relatively fast process-control signals. Place the device near the sensor connector, keep the differential route compact, and separate sensitive analog traces from motor, relay, and power-converter switching paths. Production designs should verify the sensor excitation range, amplifier supply limits, common-mode range, calibration stability, and environmental requirements for the target installation.

🎧

Audio and Low-Level Differential Sensing

The INA111BUG4 can be evaluated for audio or other balanced low-level differential sensing when the design benefits from fast signal acquisition and minimal source loading. Its less-than-20 pA input bias current reduces interaction with high-impedance sources, while the instrumentation-amplifier configuration rejects common-mode signals present on balanced lines. The amplifier should be positioned near the connector or source, with balanced routing and a quiet reference plane to preserve signal integrity. Engineers must verify the required gain, input and output swing, noise performance, bandwidth, and whether the target source impedance lies within the manufacturer’s recommended range.

ملخص المنتجات الموصى بها

INA114 Precision instrumentation amplifier for bridge and transducer measurement يُستخدم في: Bridge Transducer Signal Conditioning, Precision Current Sensing, Medical Instrumentation, Laboratory Data Acquisition, Industrial Sensor Interface, Audio and Low-Level Differential Sensing INA103 Low-noise instrumentation amplifier for high-precision measurement يُستخدم في: Bridge Transducer Signal Conditioning, Laboratory Data Acquisition, Audio and Low-Level Differential Sensing INA118 Precision current-measurement instrumentation amplifier يُستخدم في: Precision Current Sensing, Industrial Sensor Interface INA117 Precision amplifier candidate for instrumentation signal chains يُستخدم في: Medical Instrumentation
What is the operating voltage range of INA111BUG4?
The INA111BUG4 operates from the supply range specified for the INA111 family in the Texas Instruments manufacturer datasheet. The listing identifies the device as a single-circuit, 16-pin SOIC instrumentation amplifier with a 2 MHz gain-bandwidth product. Before designing the power tree, use the datasheet supply-voltage table to confirm that the selected rail remains within both the input and output operating limits.
Where can I download the INA111BUG4 datasheet PDF?
The official INA111BUG4 datasheet PDF is available from the Texas Instruments documentation link on this page. It describes a high-speed FET-input instrumentation amplifier with input bias current below 20 pA, a 2 MHz gain-bandwidth product, and operation from -40°C to +85°C. Use the manufacturer document for the authoritative pin description, recommended application circuit, electrical tables, and gain-setting information.
What is the gain-bandwidth product of INA111BUG4?
The INA111BUG4 has a gain-bandwidth product of 2 MHz. This means that the available closed-loop bandwidth becomes lower as the selected gain increases, following the usual gain-bandwidth trade-off for a feedback amplifier. The Texas Instruments manufacturer datasheet should be used to select the external gain resistor and determine whether the resulting closed-loop bandwidth meets the signal bandwidth requirement.
Why is the input bias current of INA111BUG4 important?
The INA111BUG4 has an input bias current below 20 pA, a major advantage when measuring high-impedance sources. According to the Texas Instruments manufacturer product page, the low bias current simplifies input filtering and limits source loading. A lower input current produces less source-induced voltage error, helping preserve the integrity of weak sensor and bridge signals.
Is INA111BUG4 suitable for high-impedance sensor measurement?
The INA111BUG4 is suitable for high-impedance differential sensors because its FET input bias current is below 20 pA and it is specified for source impedances of approximately 2 kΩ to 50 kΩ. This prevents the amplifier from appreciably loading the sensor source. Texas Instruments also identifies INA114 and INA103 as alternatives to examine when lower offset, lower drift, or different source-impedance requirements dominate the design.
What is the difference between the INA111 and a conventional operational amplifier?
The INA111 is an instrumentation amplifier optimized to amplify small differential voltages while rejecting common-mode signals, whereas a conventional operational amplifier requires a carefully constructed difference circuit. Its FET inputs reduce bias current below 20 pA, and its 2 MHz gain-bandwidth product supports comparatively fast signal conditioning. These characteristics make the INA111 more suitable for direct bridge, transducer, and precision sensing interfaces.
Can INA111BUG4 replace an INA118UB without changing the PCB?
A direct no-change replacement cannot be confirmed from the published comparison information alone. INA118UB is identified as a comparison candidate, but package dimensions, pin functions, supply range, gain architecture, bandwidth, and electrical limits must all match before PCB reuse is acceptable. Consult the pin-description tables and recommended application circuits in both manufacturer datasheets, then verify every rail, signal, and external component connection.
What is the best drop-in replacement for INA111BUG4?
The best drop-in replacement must use the same 16-pin SOIC footprint and preserve the INA111 pin functions, supply limits, gain-setting method, bandwidth, and external compensation requirements. No five verified, pin-compatible alternatives were identified in the available cross-reference results. Treat INA118UB and INA117KU as comparison leads rather than drop-in parts, and confirm their manufacturer documentation before modifying an existing design.
What are the key specifications of INA111BUG4 that engineers should know?
The key INA111BUG4 specifications include a 2 MHz gain-bandwidth product, input bias current below 20 pA, a 16-pin SOIC package, and an operating temperature range of -40°C to +85°C. The Texas Instruments manufacturer documentation also identifies the INA111 as a high-speed FET-input instrumentation amplifier. These figures make it useful for low-level differential measurements where source loading and common-mode interference are important.
When should I choose INA111BUG4 instead of INA114?
Choose INA111BUG4 when a high-speed signal path and very low input bias current are more important than the INA114’s improved offset-voltage and drift characteristics for higher-impedance sources. The manufacturer datasheet notes that INA114 may offer lower offset voltage and drift with source impedances of 2 kΩ to 50 kΩ. INA111 is preferable when its 2 MHz bandwidth and FET input behavior better match the measurement system.
What is the INA111BUG4 pinout in the 16-pin SOIC?
The INA111BUG4 uses a 16-pin SOIC, but the complete numbered pin list is not reproduced here. Use the pin-description table in the Texas Instruments manufacturer datasheet when assigning PCB tracks, particularly for supply connections, input terminals, feedback or gain-setting components, and exposed functional pins. Verifying the numbering against the package drawing prevents errors when adapting an existing instrumentation-amplifier layout.
Where can I buy INA111BUG4 and check its lead time?
The current commercial status and lead time for INA111BUG4 should be requested through the Request a Quote form on this page. The form lets an engineer confirm exact suffix compatibility, order quantity, delivery timing, and packaging requirements before placing a purchase. The manufacturer product page remains the authoritative source for lifecycle status and ordering options.
How much does INA111BUG4 cost?
Use the Request a Quote form on this page for the current INA111BUG4 commercial offer and any volume-related pricing. The final amount can depend on order quantity, packaging, component condition, and market availability. Providing the exact MPN and required production quantity in the request allows the quotation to be matched to the correct 16-pin SOIC ordering configuration.
Is INA111BUG4 in stock?
Current INA111BUG4 stock should be confirmed through the Request a Quote form on this page. Provide the required quantity, acceptable packaging, and target delivery date so the order team can return an availability-backed quotation. For new production designs, avoid basing the schedule solely on an inventory snapshot because component allocation can change with market demand.
What cross-brand part should I evaluate as an INA111 equivalent?
Analog Devices is identified in the cross-reference results as a manufacturer associated with INA111 alternatives, but a specific cross-brand drop-in MPN is not established by the available information. A valid equivalent must match the 16-pin SOIC footprint, pin functions, supply range, gain equation, bandwidth, common-mode range, and external component requirements. Review the candidate’s manufacturer datasheet before treating it as a drop-in replacement.

بيانات مرجعية هندسية لـ INA111BUG4 — المقارنة وإرشادات التصميم ومعلومات الامتثال.

دليل الاختيار

Choose the INA111BUG4 when the design needs a low-level differential measurement with high input impedance, a 2 MHz gain-bandwidth product, and a 16-pin SOIC footprint. Its FET input bias current below 20 pA is especially useful for high-impedance sensors, while the instrumentation-amplifier architecture simplifies differential acquisition and common-mode rejection. Consider the INA114 when lower offset voltage and lower drift are more important than maximum signal speed, particularly for source impedances of 2 kΩ to 50 kΩ. Consider the INA103 for very low source impedance when improved accuracy and noise are priorities. INA118UB and INA117KU should be treated as comparison candidates rather than confirmed replacements because their package, pin functions, gain architecture, and electrical limits have not been established as compatible with the INA111BUG4.

المقارنة مع البدائل

المعامل هذا المنتج
Package 16-pin SOIC
Brand Texas Instruments
Product Type High-speed FET-input instrumentation amplifier
Number of Circuits 1 circuit
Gain-Bandwidth Product 2 MHz
Input Bias Current Less than 20 pA
Input Transistor Type FET input
Operating Temperature Range -40°C to +85°C
Recommended Source Impedance Range 2 kΩ to 50 kΩ
Mounting Type Surface mount

أبرز الفروقات

  • High-speed signal conditioning (مقابلINA114)
  • Minimal interaction with high-impedance sources (مقابلINA117KU)
  • FET-input instrumentation-amplifier architecture (مقابلINA118UB)

ملاحظات التصميم

Place the INA111BUG4 close to the input source and connect the differential inputs with matched, tightly coupled routing. The external gain-setting component and any compensation network should also be positioned close to the amplifier to minimize parasitic resistance and inductance. Keep the SOIC ground connection continuous and use a quiet analog ground strategy; long input loops can increase noise pickup and make common-mode rejection less predictable.

Connect the bypass capacitors directly between the supply pins and their designated return pins, with the shortest possible traces. The 2 MHz gain-bandwidth product means that supply decoupling and printed-circuit-board return paths can materially affect high-frequency behavior. Use the recommended capacitor type and value from the manufacturer application circuit, and avoid placing noisy switching-regulator nodes or high-current return paths beneath the sensitive input and feedback components.

Do not select the closed-loop gain without checking the corresponding bandwidth and settling behavior. Available bandwidth decreases as gain rises, and a circuit that meets its noise requirement may not settle within the measurement window. Use the gain-versus-frequency curves and external-component guidance in the Texas Instruments manufacturer datasheet, then validate the worst-case combination of gain, source impedance, temperature, supply variation, and output load.

A common design error is assuming that the SOIC-16 footprint alone proves replacement compatibility. Pin functions, gain-setting networks, supply limits, input common-mode range, output swing, compensation requirements, and package dimensions must also match. The available cross-reference results identify comparison candidates but do not establish five verified pin-to-pin substitutes. Therefore, treat INA118UB and INA117KU as evaluation leads and verify them against the original design before PCB reuse.

معلومات الامتثال

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
خالٍ من الرصاص
Unknown
خالٍ من الهالوجين
Unknown
المعادن المتنازع عليها
Unknown

The manufacturer documentation identifies the INA111 as an active product, but explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations are not present in the referenced source material.

تم التحقق من البيانات في: 2026-11-14 — تم التحقق من البيانات وتنسيقها بواسطة فريق هندسة المكونات في XAIPART

عمليات بحث ذات صلة

INA111BUG4 datasheet INA111BUG4 pinout INA111BUG4 datasheet pdf INA111BUG4 equivalent INA111BUG4 replacement INA111BUG4 cross reference INA111BUG4 16 pin SOIC INA111BUG4 2 MHz INA111BUG4 FET input amplifier INA111BUG4 price INA111BUG4 stock Texas Instruments INA111BUG4 INA111BUG4 vs INA118UB INA111BUG4 application circuit what can replace INA111BUG4

المكونات والمصطلحات ذات الصلة

Texas Instruments INA111BUG4 INA111 INA114 INA103 INA118 INA117 instrumentation amplifier precision amplifier FET-input amplifier low-dropout input stage differential amplifier common-mode rejection input bias current gain-bandwidth product bridge transducer current-sense amplifier medical instrumentation industrial sensor interface laboratory data acquisition 16-pin SOIC SOIC family surface-mount package analog signal conditioning RoHS REACH
عرض سعر سريع RFQ
املأ التفاصيل الكاملة — سيرد فريق المبيعات لدينا خلال 24 ساعة
رقم القطعة الشركة المصنعة الحزمة QTY السعر المستهدف الإجمالي
✓
تم إرسال عرض السعر!

سنرد على بريدك الإلكتروني خلال 24 ساعة

1
تم إرسال طلب عرض السعر
2
تم استلام عرض السعر
3
تم تقديم الطلب
4
الدفع
5
تم الشحن
6
تم التسليم
عرض تفاصيل طلب عرض السعر