INA2141PA Overview

The Texas Instruments INA2141PA is a dual, low-power instrumentation amplifier with selectable gains of 10 and 100, supplied in a 16-pin PDIP package. It is designed for conditioning differential sensor signals where high input impedance, accurate differential measurement, and a fixed gain range simplify analog front-end design. The dual configuration provides two instrumentation-amplifier channels on one package.

An instrumentation amplifier is a specialized analog signal-conditioning IC that amplifies the voltage difference between two inputs while rejecting signals common to both inputs. Its application hierarchy is instrumentation amplifier, differential amplifier, analog amplifier, signal-conditioning IC, and semiconductor. This makes the INA2141PA appropriate for bridge-based sensing, current measurement, and low-level differential signal acquisition.

The INA2141 family offers two supported gain choices, 10 and 100, allowing a designer to select sensitivity according to the expected sensor output. The dual-channel architecture is useful when the system must measure two related quantities, reduce component count, or preserve consistent analog characteristics across channels. Its through-hole PDIP package supports conventional PCB assembly and prototype or repair workflows.

According to the manufacturer product page, INA2141 is a low-power instrumentation amplifier intended for precision differential signal conditioning. The device family combines differential input handling with fixed-gain operation, reducing the need for discrete op-amp networks around bridges and sensors. Its dual-channel arrangement also simplifies layout when several low-level signals must be conditioned before conversion or processing.

Typical uses include weighing and force sensing, industrial bridge interfaces, current-shunt measurement, biomedical instrumentation, and factory automation. The gain choices make the device useful when a modest input range requires amplification by 10, while a smaller signal such as a millivolt-level bridge output may benefit from the gain-100 setting.

For PCB design, place each instrumentation-amplifier channel close to its source to minimize differential pickup and keep high-impedance input routing away from switching nodes. Use a quiet ground reference and follow the manufacturer pin-description table for supply, input, reference, and output connections. Confirm the complete electrical limits, common-mode range, output swing, and recommended external-component values in the manufacturer datasheet.

This page organizes the exact package and family information with engineering-oriented application guidance, replacement analysis, comparison fields, and practical layout considerations. It is intended to help engineers confirm fit before committing the INA2141PA to a new sensor-conditioning board.

Drop-in alternatives for INA2141PA — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with INA2141PA (same form factor and footprint) — differing in Package.

Texas Instruments
Package: 16-pin plastic DIP (PDIP)
Compare with INA2141PA →

No drop-in alternatives available for this product.

Request Alternatives

INA2141PA Maximum Ratings & Electrical Characteristics

Device Type Dual instrumentation amplifier
Number of Channels 2 circuits
Gain Option 1 10 V/V
Gain Option 2 100 V/V
Power Classification Low power
Package 16-pin PDIP
Terminal Count 16 terminals
Mounting Style Through-hole
Temperature Grade Industrial

INA2141PA 16-pin pdip Pin Configuration Guide

Pin configuration for INA2141PA (16-pin pdip package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.

16-pin pdip package pinout diagram for INA2141PA

No detailed pinout data available for INA2141PA.

Refer to the datasheet for full pin configuration.

Typical Applications

INA2141PA is suitable for 6 applications: Load-Cell and Weighing Systems, Industrial Current-Shunt Measurement, Precision Bridge Sensor Interfaces, Biomedical Signal Conditioning, Factory Automation and Control I/O, Test and Measurement Front Ends.

⚖️

Load-Cell and Weighing Systems

The INA2141PA is well suited to two-channel bridge-sensor conditioning because it combines differential instrumentation-amplifier operation with selectable gains of 10 and 100. A load cell normally produces a small differential voltage around a common-mode reference, and the two gain choices provide useful sensitivity options for different bridge sensitivities. The dual arrangement can support one measurement channel for load sensing and another for temperature compensation. Place the amplifier close to the bridge output, keep the differential input traces short and matched, and connect the reference input to the system ground strategy used by the bridge and analog front end. Verify the complete common-mode range and output swing for the bridge excitation and mechanical load range before finalizing the gain selection.

⚡

Industrial Current-Shunt Measurement

The INA2141PA can condition two differential current-shunt signals when their amplitudes fall within the gain-10 or gain-100 operating range. Instrumentation-amplifier architecture is useful in power-monitoring and industrial-control systems because the desired current information is represented as a small differential voltage across a shunt. The two channels permit simultaneous monitoring of a system supply and an individual load. Keep each shunt in the high-current power path, while routing the sense traces as a tight differential pair to the amplifier. Verify shunt common-mode voltage, amplifier input limits, output swing, and bandwidth at the selected gain; these electrical conditions determine whether the INA2141PA can safely replace a discrete difference-amplifier network.

🏭

Precision Bridge Sensor Interfaces

The INA2141PA provides a practical dual-channel interface for pressure, strain, and other bridge-based sensors whose outputs require differential amplification. The selectable gain of 100 supports lower-level sensor signals, while gain 10 can serve higher-output bridges without unnecessary amplification. Its instrumentation-amplifier configuration is intended to reduce common-mode pickup, which is important when the sensor output is small relative to the bridge excitation voltage. Maintain a quiet reference node and route each input pair away from switching power stages. The design should also account for sensor excitation stability, amplifier gain error, input offset, output range, and the acquisition bandwidth required by the mechanical measurement.

💊

Biomedical Signal Conditioning

The INA2141PA can serve as the first analog stage for low-level differential biomedical signals when the selected gain and electrical limits match the sensing electrodes. The dual-channel structure can process two related physiological signals while maintaining a consistent amplifier architecture. Because biomedical instrumentation is sensitive to offset, noise, interference, and patient-safety isolation requirements, engineers must confirm the complete datasheet limits and the system's applicable isolation and regulatory design. Keep input routing short, protect sensitive nodes from contamination, and use a low-noise reference arrangement. The INA2141PA should only be selected after verifying that the gain-10 or gain-100 mode supports the electrode signal and downstream converter input range.

🏭

Factory Automation and Control I/O

The INA2141PA fits factory automation modules that must measure two low-level differential inputs and present conditioned analog signals to a controller or data converter. Selectable gains of 10 and 100 allow the same device family to cover two signal ranges when each channel is configured independently. Its through-hole package is also convenient for legacy industrial control boards, test fixtures, and maintenance platforms that use through-hole assembly. Keep sensor and amplifier grounds arranged to prevent switching currents from entering the differential input loop. Validate the supply requirements, input common-mode range, output swing, and operating temperature against the machine's environment. Protection, filtering, and isolation may need separate components depending on the field wiring.

🔧

Test and Measurement Front Ends

The INA2141PA is appropriate for bench and laboratory front ends that acquire two differential signals with gains of 10 or 100. Instrumentation-amplifier behavior simplifies conditioning of bridge outputs, voltage-divider differentials, and other small signals that share a substantial common-mode component. The dual package reduces the number of amplifier sections required in a multi-channel instrument while retaining a straightforward 16-pin PDIP layout. Use a low-noise supply, a stable reference arrangement, and symmetrical routing between the differential inputs. Before setting the gain, confirm the signal's bandwidth, input limits, output swing, offset, and gain accuracy against the acquisition system. The manufacturer datasheet should also guide selection of any recommended external resistors or capacitors.

Recommended Products Summary

INA2141 Dual instrumentation-amplifier family device Used in: Load-Cell and Weighing Systems, Industrial Current-Shunt Measurement, Precision Bridge Sensor Interfaces, Biomedical Signal Conditioning, Factory Automation and Control I/O, Test and Measurement Front Ends INA2141PA Texas Instruments Used in: Load-Cell and Weighing Systems, Industrial Current-Shunt Measurement, Precision Bridge Sensor Interfaces, Biomedical Signal Conditioning, Factory Automation and Control I/O, Test and Measurement Front Ends
What is the INA2141PA instrumentation amplifier?
The INA2141PA is a dual, low-power instrumentation amplifier from Texas Instruments with selectable gains of 10 and 100. It provides two signal-conditioning channels in a 16-pin PDIP package. According to the Texas Instruments INA2141 product page, the device is intended for differential measurement applications where input impedance and common-mode signal rejection are important.
What are the key specifications of INA2141PA that engineers should know?
The INA2141PA combines two amplifier circuits, selectable gains of 10 and 100, a 16-pin PDIP package, and a low-power instrumentation-amplifier design. According to the Texas Instruments INA2141 product page, its principal functions are differential signal conditioning and amplification. Check the manufacturer datasheet for supply voltage, common-mode range, offset, bandwidth, and output-swing limits before finalizing a design.
Where can I download the INA2141PA datasheet PDF?
The official INA2141 documentation is available through the Texas Instruments product page linked on this listing. Use the manufacturer datasheet to confirm the complete pin-description table, recommended application circuit, electrical characteristics, and ordering information. The linked product page is the most authoritative starting point because it also connects directly to current TI document revisions and package options.
Where can I find the INA2141PA pinout?
The INA2141PA uses a 16-pin PDIP package, and its authoritative pin assignments are shown in the Texas Instruments INA2141 datasheet. Use the pin-description table to identify each differential input, supply, ground, reference, and output connection before routing the PCB. Do not infer pin functions from the package drawing alone because dual-channel instrumentation amplifiers can have channel-specific and shared terminals.
When should I choose the INA2141PA for sensor conditioning?
Choose the INA2141PA when a design needs two low-level differential measurement channels with selectable gain of 10 or 100. Its instrumentation-amplifier configuration is well suited to bridge sensors and shunt measurements where rejecting common-mode voltage is central to signal integrity. Confirm that the sensor output remains within the device's input and common-mode limits for the selected gain.
Is the INA2141PA suitable for bridge sensors and current measurement?
Yes, the INA2141PA is suitable for bridge-sensor and current-shunt measurement when the required signal level matches its gain-10 or gain-100 operating range. Differential instrumentation-amplifier operation helps suppress voltage shared by both inputs. The exact input range, output swing, gain error, and permissible shunt bandwidth must be checked in the manufacturer datasheet.
What can replace the INA2141PA?
A valid replacement for the INA2141PA must use the same 16-pin PDIP footprint, preserve the two-channel differential architecture, and remain electrically compatible with gains of 10 and 100. The substitution search did not identify a candidate whose package, pinout, and gain options were all confirmed. Treat any proposed replacement as unverified until its pin assignment and electrical limits have been checked against the INA2141 datasheet.
What is the best drop-in replacement for INA2141PA?
No drop-in replacement is confirmed by the available cross-reference results for the INA2141PA. A suitable substitute must specifically match the 16-pin PDIP package and pinout, provide two channels, and support compatible gain and common-mode requirements. Because a same-package part with different gain or electrical limits could disrupt an existing board, request manufacturer confirmation before treating any candidate as a drop-in replacement.
Is INA2141PA the same as the INA2141 family device?
INA2141PA is the orderable 16-pin PDIP version of the Texas Instruments INA2141 instrumentation-amplifier family. The family name describes the circuit family, while the PA suffix identifies this package and ordering configuration. The 16-pin PDIP package is suitable for through-hole assembly, unlike surface-mount order codes that require a different footprint.
Where to buy INA2141PA online?
Use the Request a Quote form on this page to request INA2141PA availability, current lead time, and order handling through XAIPART. The form is the appropriate route for a quote-based electronic component purchase and for checking the exact 16-pin PDIP order configuration. The manufacturer part number INA2141PA should be stated on the request to avoid confusion with other INA2141 package options.
What is the price of INA2141PA?
The current INA2141PA commercial price is handled through the Request a Quote form on this page. The structured listing does not contain a qualifying exact-MPN quantity-break table, so no static price figure is displayed. Submit the quantity, target package, delivery location, and required production dates with the quote request for an actionable response.
What is the lead time for INA2141PA?
Request the current INA2141PA lead time through the Request a Quote form on this page. Include the required quantity, scheduled delivery date, and whether the order is for prototype, production, or maintenance use. The manufacturer product page is the authoritative source for current ordering information, while XAIPART can confirm channel handling for the requested quantity.
Is INA2141PA in stock?
Current INA2141PA stock status should be confirmed through the Request a Quote form on this page because the available commercial information does not establish a fixed on-hand quantity. Include your required quantity and target date so the response reflects the requested order rather than a generic inventory statement. Confirm the final part number as INA2141PA, the 16-pin PDIP configuration.
How does the INA2141PA compare with other instrumentation amplifiers?
The INA2141PA is distinguished within its comparison set by two channels, selectable gains of 10 and 100, and a 16-pin PDIP package. Any direct comparison should focus on common-mode range, offset, gain error, bandwidth, supply voltage, and output swing rather than gain alone. No cross-brand drop-in candidate was confirmed, so the manufacturer electrical table remains the basis for engineering selection.
Does INA2141PA support RoHS and AEC-Q100 applications?
The RoHS and AEC-Q100 status of the INA2141PA is not stated on the linked product-page excerpt, so neither qualification should be assumed for a regulated design. Review the current Texas Instruments product declarations and material-compliance documentation for the exact orderable MPN. Automotive qualification also requires confirmation that the complete device and package are covered by the relevant automotive grade documentation.

Engineering reference data for INA2141PA — comparison, design guidance, and compliance information.

Selection Guide

Choose the INA2141PA when the design needs two differential signal-conditioning channels, selectable gains of 10 and 100, and a 16-pin through-hole package. It is particularly suitable for bridge sensors, low-level shunt measurements, laboratory instrumentation, and industrial control boards that require a straightforward dual-channel layout. Confirm that the sensor output remains within the common-mode and differential input limits, that the selected gain leaves sufficient output swing, and that the acquisition bandwidth meets the signal requirements. Do not choose a substitute solely because it is an instrumentation amplifier: a direct drop-in candidate must also preserve the 16-pin PDIP pinout, two-channel architecture, and compatible gain options. Surface-mount alternatives may offer different board-area advantages, but they are not drop-in replacements for this footprint. If the application requires automotive qualification, extended temperature coverage, isolation, rail-to-rail input operation, or a substantially wider gain range, verify those requirements separately before committing the design.

Comparison with Alternatives

Parameter This Product
Package 16-pin PDIP
Brand Texas Instruments
Number of Channels 2 circuits
Gain Options 10 and 100 V/V
Architecture Low-power instrumentation amplifier
Mounting Style Through-hole
Temperature Grade Industrial

Key Differentiators

  • Two measurement channels in one package (vs Single-channel instrumentation-amplifier options)
  • Two selectable gain choices (vs Fixed-gain instrumentation amplifiers)
  • Legacy-compatible through-hole assembly (vs Surface-mount instrumentation amplifiers)

Design Notes

Route each differential input as a compact pair and place the INA2141PA close to the sensor or shunt source. Keep the two traces symmetrical, minimize loop area, and avoid routing them beside switching nodes, relay contacts, motor traces, or high-current power paths. Use a continuous ground reference beneath the analog section when board space permits, and connect the amplifier reference node according to the manufacturer application circuit.

Do not select a gain solely from the nominal sensor output. Check the minimum and maximum signal, input common-mode range, output voltage swing, gain error, offset, and required bandwidth at the selected gain setting. The gain-100 mode can amplify input offset and reduce usable output headroom, while a gain-10 choice may not provide enough signal for the downstream converter. Perform worst-case calculations across supply tolerance and sensor excitation variation.

Keep analog and digital return currents separated as far as practical, especially when the INA2141PA is used near a switching supply, microcontroller, or display interface. Place any required bypass capacitors close to the relevant supply pins, use short ground returns, and avoid long shared copper paths beneath sensitive input routing. Check the manufacturer pin-description table and recommended component values before releasing the layout.

Choose gain and bandwidth together rather than maximizing gain in isolation. Higher gain improves sensitivity to small differential signals but can amplify offset, noise, and bandwidth limitations. For long sensor cables, add appropriate input filtering or protection and validate the complete signal chain with the actual source impedance. Confirm that the common-mode and differential input limits remain satisfied during startup, fault conditions, and sensor disconnection.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

The available manufacturer product-page excerpt does not state material-compliance or automotive qualification status for INA2141PA. Review the current Texas Instruments compliance and qualification documentation for the exact orderable device.

Related Searches

INA2141PA datasheet INA2141PA pinout INA2141PA datasheet pdf INA2141PA equivalent INA2141PA replacement INA2141PA drop-in replacement INA2141PA price INA2141PA stock Texas Instruments INA2141PA INA2141PA 16-pin PDIP INA2141PA gain 10 100 INA2141PA bridge sensor amplifier

Related Components & Terms

Texas Instruments INA2141 INA2141PA instrumentation amplifier differential amplifier analog amplifier signal-conditioning IC semiconductor low-power amplifier selectable gain gain of 10 gain of 100 16-pin PDIP through-hole package common-mode rejection differential input bridge sensor current-shunt measurement factory automation biomedical instrumentation test and measurement RoHS REACH AEC-Q100
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details