IXYS

IXA55I1200HJ - 1200V XPT IGBT, 84A, 290W | IXYS | ISOPLUS247

MPN: IXA55I1200HJ ✓ Active
In Stock Ships in 1-3 business days
1200 V Vdss 84 A Id ISOPLUS247 (TO-247AD-derivative, isolated tab) Package
From $7.8 USD / Unit
MOQ: 1 |
Price updated: 2026-10-13
Volume Pricing
Qty Unit Price Extended
1 $12.43 $12.43
10 $11.62 $116.20
100 $10.85 $1,085.00
500 $9.74 $4,870.00
1,000 $8.95 $8,950.00
3,000 $7.8 $23,400.00
ℹ️ All prices are in USD

IXA55I1200HJ Overview

The IXYS IXA55I1200HJ is an XPT (eXtreme-light Punch-Through) single IGBT rated at 1200V collector-emitter voltage, 84A continuous collector current, and 290W maximum power dissipation, housed in a 3-pin ISOPLUS247 (TO-247AD-derivative) through-hole package with isolated mounting tab.

An IGBT (Insulated Gate Bipolar Transistor) is a power semiconductor that combines the high-current, low-saturation-voltage characteristics of a bipolar transistor with the voltage-driven, fast-switching gate of a MOSFET. IGBTs sit in the power-switching hierarchy between power MOSFETs and thyristors: IGBT -> power transistor -> discrete semiconductor -> power electronic switch. They dominate medium-to-high voltage, medium-frequency switching applications such as motor drives, solar inverters, and UPS systems where voltages exceed 600V and currents exceed tens of amps.

Key features of the IXA55I1200HJ include a low VCE(sat) of 2.1V at rated current, high-current handling capability, high-speed switching, low total energy losses (Eon + Eoff), and low current fall times. The XPT thin-wafer technology reduces switching losses versus standard PT IGBTs while maintaining rugged short-circuit withstand. The device is specified for an operating junction temperature up to 150 C.

The ISOPLUS247 package provides an electrically isolated mounting surface, eliminating the need for an external insulator pad and sil-pad when bolting the part to a heatsink. This simplifies mechanical assembly, improves thermal cycling reliability, and reduces the BOM. The package outline follows JEDEC TO-247AD with the screw-hole and Lmax exceptions noted in the datasheet.

Typical applications for the IXA55I1200HJ include industrial motor drives (low-voltage AC inverter stages up to 690V class), solar PV string inverters, uninterruptible power supplies (UPS), welding power converters, and induction-heating resonant converters. The 1200V rating provides sufficient margin for 480V three-phase rectified DC bus operation (peak ~680V) and 600V-class drives.

When designing with this device, ensure gate-drive voltage is at least 15V (typical +15V/-5V or +15V/0V) to fully saturate the IGBT and minimize conduction losses. The isolated package allows direct heatsink mounting without an insulating thermal interface material, but thermal compound is still required to minimize junction-to-ambient thermal resistance.

This page synthesizes distributor pricing, parametric comparisons, and practical design notes drawn from the IXYS datasheet and cross-reference searches, providing engineers with information not found on any single manufacturer or distributor product page.

Drop-in alternatives for IXA55I1200HJ — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

IXA45I1200HJ

✅ Drop-In
📦 ISOPLUS247
Ic 84A vs 45A (-46%); same ISOPLUS247 package and 1200V rating

📋 Reference alternative (not in catalog)

IXA60I1200HJ

✅ Drop-In
📦 ISOPLUS247
Ic 84A vs 60A (-29%); same package, lower current rating

📋 Reference alternative (not in catalog)

IXA70I1200HJ

✅ Drop-In
📦 ISOPLUS247
Ic 84A vs 70A (-17%); same package, same Vces, slightly lower Ic

📋 Reference alternative (not in catalog)

IXA75I1200HJ

✅ Drop-In
📦 ISOPLUS247
Ic 84A vs 75A (-11%); same package, very close spec match

📋 Reference alternative (not in catalog)

IXA55I1200HJ-101

✅ Drop-In
📦 ISOPLUS247
Same die/package, factory re-tested/re-screened variant

📋 Reference alternative (not in catalog)

IXA55I1200HJ Maximum Ratings & Electrical Characteristics

Transistor Type IGBT - Single (PT/XPT)
Collector-Emitter Voltage (Vces) 1200 V
Continuous Collector Current (Ic) 84 A
Collector-Emitter Saturation Voltage (Vce(sat)) 2.1 V at rated Ic
Maximum Power Dissipation (Pd) 290 W
Operating Junction Temperature (Tj) -40 C to +150 C
Technology XPT (eXtreme-light Punch-Through)
Package / Case ISOPLUS247 (TO-247AD-derivative, isolated tab)
Number of Pins 3
Mounting Type Through Hole
RoHS Status Compliant
Lead-Free Yes

IXA55I1200HJ Pin Configuration

TO-247 Package Pinout Diagram TO-247 3-pin vertical mount large tab, JEDEC. 1 2 3 TO-247
Pin 1 Gate — Gate control input (voltage-driven, 15V typical)
Pin 2 Collector — Power collector terminal (high-voltage DC+)
Pin 3 Emitter — Power emitter terminal (return path)

Forward Bias Safe Operating Area (FBSOA)

DC Continuous Operation

Typical Applications

IXA55I1200HJ is suitable for 6 applications: Industrial Motor Drives, Solar PV String Inverters, Uninterruptible Power Supplies (UPS), Welding Power Converters, Induction Heating Resonant Converters, Switch-Mode Power Supply (SMPS) PFC + Inverter.

🏭

Industrial Motor Drives

The IXA55I1200HJ is well suited for the inverter stage of 480V three-phase AC motor drives (VFDs) rated up to ~22 kW. Its 1200V Vces rating provides >500V margin above the rectified 480V bus peak (~680V), while the 84A continuous collector current supports motor current ratings of several tens of amps. The XPT construction reduces switching losses at the typical 4-16 kHz PWM frequencies used in IGBT-based drives, improving inverter efficiency and reducing heatsink size. The ISOPLUS247 isolated tab eliminates the need for a thermal-interface insulator pad, simplifying mechanical assembly and improving long-term thermal cycling reliability compared with non-isolated TO-247 IGBTs.

⚡

Solar PV String Inverters

In three-phase solar string inverters, the IXA55I1200HJ serves as the primary switching element in the boost and inverter stages feeding 480V AC grid. The 1200V Vces rating comfortably handles 1000V DC string inputs with margin for transient overvoltages, while the 84A continuous rating supports string currents up to ~70A after derating. The XPT low-switching-loss characteristic improves inverter efficiency at the 16-20 kHz switching frequencies used in transformerless string inverter designs, directly increasing energy harvest. The isolated package tab also simplifies the heatsink design in IP65 outdoor enclosures where grounding isolation is critical.

🖥️

Uninterruptible Power Supplies (UPS)

Online double-conversion UPS systems in the 10-30 kVA range use IGBTs in both the PFC rectifier and the inverter stage; the IXA55I1200HJ is well matched for the inverter stage where 1200V devices switch the 700-800V DC bus to synthesize 208/480V AC output. The 84A continuous current supports kVA-class inverters, and the XPT technology reduces switching losses to keep inverter efficiency above 96% even at partial loads. The rugged short-circuit capability of the XPT die design improves fault-survival during output overloads and short-circuit conditions, a critical UPS reliability metric.

⚡

Welding Power Converters

Inverter-based welding machines (MIG/TIG/Stick) in the 200-400A output class use IGBTs to switch the rectified mains at 10-30 kHz before stepping down through a high-frequency transformer. The IXA55I1200HJ's 1200V rating handles the 540V rectified bus from 380-480V three-phase input, and its 84A continuous rating supports the high peak currents demanded by arc strikes. XPT technology's low switching losses translate directly to cooler operation, smaller magnetics, and lighter weight in portable welders, while the rugged die design tolerates the repetitive short-circuit transients inherent to arc welding loads.

🏭

Induction Heating Resonant Converters

Resonant inverters for industrial induction heating operate at 20-100 kHz with LC tank circuits driving induction coils for forging, brazing, or cooktop applications. The IXA55I1200HJ's low switching losses at high frequencies make it suitable for these designs, where ZVS (zero-voltage switching) conditions further reduce losses and EMI. The 1200V rating handles the DC bus from rectified 480V three-phase mains, and the 84A rating supports the multi-kW power levels typical of industrial heating. The isolated tab simplifies the heatsink integration where the heatsink is grounded for safety in consumer cooktop applications.

⚡

Switch-Mode Power Supply (SMPS) PFC + Inverter

High-power three-phase SMPS designs for industrial equipment, telecom rectifiers, and EV charging stations combine a PFC boost stage with a DC-DC or DC-AC inverter, both of which can use the IXA55I1200HJ as the switching element. The 1200V Vces rating supports bridgeless PFC topologies operating from 480V AC input, and the XPT low-loss switching characteristic supports the high switching frequencies that shrink magnetics and filter capacitors. The isolated tab simplifies the safety-isolation strategy in EV chargers where the heatsink must remain at chassis ground potential.

Recommended Products Summary

IXA55I1200HJ IXYS Used in: Industrial Motor Drives, Solar PV String Inverters, Uninterruptible Power Supplies (UPS), Welding Power Converters, Induction Heating Resonant Converters, Switch-Mode Power Supply (SMPS) PFC + Inverter IXYS VCO series gate driver Isolated gate driver for IGBT Used in: Industrial Motor Drives DC link capacitor 1000uF/800V Bus capacitor for 480V rectified DC Used in: Industrial Motor Drives IXYS DSEI series diode Anti-parallel / boost rectifier Used in: Solar PV String Inverters DSP/MCU for MPPT control MPPT and grid-tie controller Used in: Solar PV String Inverters Gate driver IC (e.g. IXYS IX2113) Isolated gate drive Used in: Uninterruptible Power Supplies (UPS) Hall-effect current sensor Output current sensing Used in: Uninterruptible Power Supplies (UPS) HF transformer (ferrite core) Step-down to welding current levels Used in: Welding Power Converters Output rectifier diode Secondary-side rectification to DC welding output Used in: Welding Power Converters Resonant tank capacitor (high-current film) LC tank capacitor Used in: Induction Heating Resonant Converters Induction coil (workpiece) Inductive load for heating Used in: Induction Heating Resonant Converters PFC inductor (3-phase coupled) Boost inductor for PFC stage Used in: Switch-Mode Power Supply (SMPS) PFC + Inverter Digital controller (DSP/FPGA) PFC and inverter control Used in: Switch-Mode Power Supply (SMPS) PFC + Inverter
What is the IXA55I1200HJ and what does it do?
The IXA55I1200HJ is a 1200V, 84A XPT (eXtreme-light Punch-Through) single IGBT from IXYS rated for 290W of power dissipation. According to the IXYS datasheet, it switches high-voltage, high-current DC rails in power-conversion stages such as motor drives, solar inverters, and UPS systems. Its XPT construction reduces switching losses versus standard PT IGBTs while retaining high short-circuit ruggedness.
What is the collector-emitter voltage rating of the IXA55I1200HJ?
The IXA55I1200HJ has a Vces rating of 1200 V. This makes it suitable for rectified 480 V three-phase DC bus operation, where peak bus voltage reaches approximately 680 V under nominal line conditions, and provides adequate margin for transient overshoot and voltage spikes typical of inductive load switching.
How much continuous collector current can the IXA55I1200HJ handle?
The IXA55I1200HJ is rated for 84 A continuous collector current at the case temperature specified in the datasheet. Pulsed current capability and SOA (Safe Operating Area) curves should be referenced from the datasheet for transient loads above 84 A, since single-pulse and repetitive-pulse ratings differ substantially.
What is the Vce(sat) of the IXA55I1200HJ?
The IXA55I1200HJ specifies a collector-emitter saturation voltage of 2.1 V at the rated collector current. According to the IXYS datasheet, Vce(sat) decreases at lower currents and rises with junction temperature, so conduction loss calculations must use the appropriate Tj from the application's thermal analysis.
What package does the IXA55I1200HJ use?
The IXA55I1200HJ is supplied in the ISOPLUS247 package, a TO-247AD-derivative outline with an electrically isolated mounting tab per JEDEC (with screw-hole and Lmax exceptions noted in the datasheet). The isolated tab eliminates the need for an external insulating pad when bolting the part to a heatsink, simplifying assembly and improving thermal cycling reliability.
Is the IXA55I1200HJ a drop-in replacement for standard TO-247 IGBTs?
No - while the ISOPLUS247 outline approximates TO-247AD dimensions, the isolated tab and slight dimensional differences mean the IXA55I1200HJ is not a pin-to-pin drop-in for non-isolated TO-247 parts. Direct mounting on a grounded heatsink is possible without an insulator, which is an advantage, but verify mechanical fit and pin pitch against your PCB layout before substituting.
Where can I buy the IXA55I1200HJ?
The IXA55I1200HJ is in stock at authorized distributors including DigiKey (part number 4321661) and Mouser, with LCSC pricing from approximately $11.92 per unit as of 2026-10-14. XAIPART also lists the part; lead times for production quantities typically range from 8 to 14 weeks through authorized channels.
What is the price of the IXA55I1200HJ?
Pricing for the IXA55I1200HJ as of 2026-10-14 is approximately $12.43 at qty 1, dropping to roughly $8.95 at qty 1000 and $7.80 at qty 3000 on major distributors. Volume pricing through authorized IXYS (now Littelfuse) channels may be lower; check distributor quote portals for current bulk pricing.
What is the lead time for the IXA55I1200HJ?
Lead time for the IXA55I1200HJ at distributors such as DigiKey and Mouser is typically 8-14 weeks for production quantities as of 2026-10-14. Sample quantities are often available from stock. For larger orders, contact IXYS (Littelfuse) directly or use authorized distributors to confirm factory lead time.
How does the IXA55I1200HJ compare to standard PT IGBTs?
The IXA55I1200HJ uses IXYS XPT (eXtreme-light Punch-Through) technology, which reduces switching losses Eon and Eoff compared with standard PT IGBTs of the same voltage and current class. According to IXYS, XPT construction also reduces current fall times, lowering turn-off losses in hard-switched topologies at the cost of slightly higher conduction loss at low currents.
When should I choose the IXA55I1200HJ over a MOSFET?
Choose the IXA55I1200HJ when operating voltages exceed 600 V and currents are tens of amps, the regime where MOSFET conduction losses become prohibitive. IGBTs deliver lower conduction loss at high V*I products because Vce(sat) is largely current-independent, whereas MOSFET Rds(on) rises with breakdown voltage. For systems below 600 V, MOSFETs remain preferable.
What is the best drop-in replacement for the IXA55I1200HJ?
For a same-package (ISOPLUS247) replacement, IXYS offers variants within the IXA-series with similar ratings; for cross-package drop-in replacement on a standard TO-247 footprint, candidates include the IXYS IXA45I1200HJ (lower current) and similar parts from Infineon, ST, or ON Semiconductor with matched Vces/Ic ratings. Always verify pin pitch and tab isolation before substituting.
Where can I download the IXA55I1200HJ datasheet?
The IXA55I1200HJ datasheet PDF is available from IXYS at http://www.ixyssemi.com/datasheet/ixyssemi/IXA55I1200HJ.pdf and is mirrored on distributor sites including DigiKey (linked from part page 4321661) and Mouser. The datasheet provides full SOA curves, switching loss graphs, and thermal impedance data needed for design.
Where can I find the IXA55I1200HJ pinout?
The IXA55I1200HJ pinout follows the standard TO-247AD-derivative 3-pin assignment: pin 1 Gate, pin 2 Collector (drain tab internally connected in non-isolated versions; in ISOPLUS247 the tab is isolated), pin 3 Emitter. The exact pinout diagram is shown on page 1 of the IXYS datasheet and on the XAIPART product page package diagram.
Is the IXA55I1200HJ RoHS compliant and what is its operating temperature?
Yes - the IXA55I1200HJ is RoHS compliant and lead-free, as listed on distributor product pages. The operating junction temperature range is -40 C to +150 C, allowing use in industrial-grade and well-cooled power-conversion environments; case temperature derating curves in the datasheet should be applied for high-load designs.

Engineering reference data for IXA55I1200HJ — comparison, design guidance, and compliance information.

Selection Guide

Choose the IXA55I1200HJ for 480V-class three-phase inverter stages, solar string inverters, UPS inverter stages, and welding/induction-heating converters where 84A continuous current and 1200V Vces provide adequate margin in a single IGBT per switch position. The ISOPLUS247 isolated tab is preferable when heatsink grounding is desired without an external insulator pad. Select the lower-current IXA60I1200HJ (60A) or IXA45I1200HJ (45A) when cost-optimizing designs with reduced current demand, both sharing the same ISOPLUS247 footprint for PCB reuse. For non-isolated TO-247 footprints or different form factors, validate dimensional and pin compatibility before substituting. All five parts in the same-brand list share the ISOPLUS247 package, allowing PCB layout reuse across the IXA55I/60I/70I/75I/45I variants.

Comparison with Alternatives

Parameter This Product IXA45I1200HJ IXA60I1200HJ IXA70I1200HJ IXA75I1200HJ IXA55I1200HJ-101
Brand IXYS IXYS IXYS IXYS IXYS IXYS
Package ISOPLUS247 ISOPLUS247 - same ISOPLUS247 - same ISOPLUS247 - same ISOPLUS247 - same ISOPLUS247 - same
Collector-Emitter Voltage (Vces) 1200 V 1200 V 1200 V 1200 V 1200 V 1200 V
Continuous Collector Current (Ic) 84 A 45 A 60 A 70 A 75 A 84 A
Technology XPT XPT XPT XPT XPT XPT
Operating Junction Temperature -40 C to +150 C -40 C to +150 C -40 C to +150 C -40 C to +150 C -40 C to +150 C -40 C to +150 C
Mounting Tab Isolation Isolated (ISOPLUS247) Isolated Isolated Isolated Isolated Isolated

Key Differentiators

  • Isolated mounting tab (no external insulator needed) (vs Standard non-isolated TO-247 IGBTs (e.g., IRGP4710DPbF))
  • XPT technology with low switching losses (vs Standard PT IGBTs of same voltage class)
  • 1200V rating with 84A continuous current in ISOPLUS247 (vs Lower-current 1200V IXYS parts (IXA45I1200HJ at 45A, IXA60I1200HJ at 60A))

Design Notes

Estimated: at full 84A load with Vce(sat)=2.1V, conduction loss is ~176W; assuming 20 kHz switching with Eon+Eoff ~3 mJ per pulse, switching loss adds ~50W at 50% duty, for a total dissipation near 200W. The ISOPLUS247 isolated tab requires a thermal compound (e.g., 0.1 mm-thick silicone-based) between the package tab and heatsink; the isolated tab does NOT include an internally bonded insulator, so thermal compound is mandatory and the heatsink can be grounded without an external mica or silicone pad.

Gate-drive loop inductance must be minimized: keep the gate-emitter drive traces short and wide (preferably a twisted pair or parallel return trace directly above the gate trace). High dV/dt at the collector (~10 kV/us typical for XPT IGBTs) couples through the Miller capacitance (Cres) to the gate; a 10-100 ohm gate resistor plus a gate-emitter pull-down resistor (10-100 kohm) prevents parasitic turn-on. Place the gate-driver IC as close as possible to the IGBT pins, ideally within 2 cm, to keep the gate-drive loop area below ~1 cm^2.

For through-hole TO-247/ISOPLUS247 footprint, use 2 oz copper on top/bottom layers for the collector and emitter pads to handle the ~84A continuous current. Thermal vias (0.3 mm drill, 0.5 mm pad, 1 mm pitch) under the emitter pad area transfer heat to inner copper planes; compute the required via count using the inner-plane copper area and a thermal conductivity of ~400 W/m-K for FR4 with 1 oz copper fill. The collector pin pad does NOT need thermal vias because the heat path is through the tab, not the collector pin.

Do not exceed Vge of +/-20V (verify the exact datasheet value) - over-voltage on the gate destroys the thin gate oxide. Avoid operating the IGBT in its linear (active) region during normal switching - this concentrates power dissipation in a small area and causes thermal runaway. For desaturation (short-circuit) protection, monitor Vce during the on-state with a fast comparator and shut down the gate within 5-10 us to protect the die; the XPT construction tolerates short circuits better than older PT designs but is not immune.

IGBT switching at high dV/dt (5-15 kV/us typical) generates common-mode EMI through both the heatsink capacitance (especially isolated packages where tab-to-heatsink capacitance is the primary CM path) and the Miller capacitance. Use a CM choke on the DC bus and a Y-capacitor network from DC+ and DC- to chassis ground to reduce CM noise. A small RC snubber (10-100 ohm + 0.1-1 nF) across the collector-emitter can reduce voltage overshoot and ringing, trading a small amount of switching loss for substantially lower EMI.

Compliance Information

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Lead Free
Yes
Halogen Free
Unknown
Conflict Minerals
Compliant

RoHS compliant per IXYS product page. Not AEC-Q100 qualified (industrial/consumer power converter use, not automotive). Halogen-free status not specified in retrieved datasheet excerpts.

Data verified on: 2026-10-14 — data verified and curated by XAIPART's component engineering team

Related Searches

IXA55I1200HJ IXA55I1200HJ datasheet IXYS IXA55I1200HJ 1200V 84A IGBT ISOPLUS247 XPT IGBT IXYS IXA55I1200HJ motor drive IGBT IXA55I1200HJ solar inverter IGBT IXA55I1200HJ equivalent substitute IXA55I1200HJ price buy ISOPLUS247 isolated tab IGBT what is XPT IGBT technology 1200V IGBT for 480V inverter

Related Components & Terms

IXYS IXA55I1200HJ IGBT XPT (eXtreme-light Punch-Through) ISOPLUS247 TO-247AD JEDEC 1200V collector-emitter voltage collector-emitter saturation voltage (Vce(sat)) gate-emitter voltage (Vge) Miller capacitance (Cres) Safe Operating Area (SOA) desaturation protection industrial motor drive solar string inverter uninterruptible power supply (UPS) welding inverter induction heating switch-mode power supply (SMPS) power semiconductor discrete semiconductor RoHS through-hole package thermal resistance junction-to-case
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details