MAX232CASE+ - 5V Dual RS-232 Transceiver | Maxim Integrated
MPN: MAX232CASE+ ✗ End of LifeMAX232CASE+ Overview
An RS-232 transceiver is an interface IC that converts between logic-level signals used by digital systems and the voltage levels defined for RS-232 communications. The MAX232 belongs to the broader line-driver and line-receiver hierarchy: it combines a dual transmitter, a dual receiver, and an internal charge-pump supply that develops the bipolar voltages required for RS-232 transmission. This integration allows a modern controller or programmable logic device to connect to a legacy serial port using a single 5 V supply.
The device provides two transmit channels and two receive channels in a full-duplex arrangement. Its maximum signaling rate is 120 kbps, while receiver hysteresis is 500 mV. The manufacturer describes the family as compliant with EIA/TIA-232E and V.28/V.24 interfaces, and the TI product page identifies ±9 V output levels and ±2 kV ESD protection for MAX232 devices. These characteristics make the interface suitable for control links, equipment communication, and legacy peripheral connections.
Internally, the charge pump generates positive and negative voltage rails from the 5 V supply. The external charge-pump capacitors must use adequate voltage ratings and low effective series resistance because ripple on those rails can affect transmitter behavior. The receiver section provides noise tolerance through its 500 mV hysteresis, helping reject small voltage disturbances on a slow or noisy serial connection. Pin-compatible family members differ principally in temperature grade, shutdown capability, or power characteristics.
Typical uses include industrial control panels, point-of-sale equipment, test systems, embedded instruments, and service ports that still use RS-232. For new designs, a currently supported family member should be preferred when its electrical ratings satisfy the application. For an existing MAX232CASE+ board, a replacement must match the 16-pin SOIC footprint, 5 V supply range, 2/2 channel configuration, capacitor connection pattern, and RS-232 signal levels.
The principal design caution is that the obsolete ordering code should not be assumed to be an active production option. Confirm lifecycle status, temperature requirements, and the exact capacitor network before committing a replacement to a new PCB. Also preserve the required charge-pump capacitor values and place them close to their associated pins to minimize loop area and supply ripple.
This page combines lifecycle information, interface specifications, drop-in family alternatives, application guidance, and PCB-focused engineering notes to support replacement planning. The comparison and design sections add practical selection context beyond the basic distributor listing, while the Request a Quote form supports current sourcing of the selected catalog number.
Drop-in alternatives for MAX232CASE+ — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Variants in this series
Same-series models that are drop-in compatible with MAX232CASE+ (same form factor and footprint) — differing in Interface Standard, Package, Product Type, Operating Temperature, RoHS Status.
MAX232CSE+
✅ Drop-InContact for price
View Datasheet →MAX232CASE+T
✅ Drop-In📋 Reference alternative (not in catalog)
MAX232ACSE+T
✅ Drop-In ⚠️ Specs UnverifiedContact for price
View Datasheet →MAX232ESE+
✅ Drop-In ⚠️ Specs UnverifiedContact for price
View Datasheet →MAX232EWE+
✅ Drop-In ⚠️ Specs UnverifiedContact for price
View Datasheet →MAX232CASE+ Specifications
| Product Type | RS-232 transceiver |
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| Duplex Type | Full duplex |
| Interface Standard | EIA/TIA-232E, V.28, and V.24 |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Nominal Supply Voltage | 5 V |
| Maximum Data Rate | 120 kbps |
| Receiver Hysteresis | 500 mV |
| RS-232 Output Level | Approximately -9 V to +9 V |
| ESD Protection | ±2 kV |
| Operating Temperature | 0°C to 70°C |
| Package | 16-pin SOIC |
| Mounting Type | Surface mount |
| Part Status | Obsolete |
| RoHS Status | Unknown |
| REACH Status | Unknown |
| AEC-Q100 Qualification | Not applicable |
MAX232CASE+ Pin Configuration
| Pin 1 | R1OUT — Receiver 1 output |
| Pin 2 | R2OUT — Receiver 2 output |
| Pin 3 | R2IN — Receiver 2 input |
| Pin 4 | R1IN — Receiver 1 input |
| Pin 5 | V- — Negative charge-pump output |
| Pin 6 | VCC — Positive supply connection |
| Pin 7 | T1IN — Driver 1 logic input |
| Pin 8 | T2IN — Driver 2 logic input |
| Pin 9 | T1OUT — Driver 1 RS-232 output |
| Pin 10 | T2OUT — Driver 2 RS-232 output |
| Pin 11 | GND — Ground |
| Pin 12 | C1+ — Charge-pump flyback capacitor 1 positive terminal |
| Pin 13 | C1- — Charge-pump flyback capacitor 1 negative terminal |
| Pin 14 | C2+ — Charge-pump flyback capacitor 2 positive terminal |
| Pin 15 | C2- — Charge-pump flyback capacitor 2 negative terminal |
| Pin 16 | VCC — Positive supply connection |
Typical Applications
MAX232CASE+ is suitable for 6 applications: Industrial Control Panels, Point-of-Sale Equipment, Test and Measurement Systems, Embedded Serial Service Ports, Security and Access Systems, Instrumentation and Diagnostics.
Industrial Control Panels
The MAX232CASE+ fits legacy industrial control panels that require a 5 V logic-side controller to communicate with RS-232 equipment over a full-duplex serial link. Its two transmitters and two receivers support two communication channels, while the 120 kbps maximum rate is sufficient for configuration commands, status polling, and supervisory data. The specified 0°C to 70°C range suits controlled indoor equipment; use the -40°C to 125°C MAX232CASE+T when the enclosure experiences wider temperature variation. Preserve the external charge-pump capacitor arrangement and keep the circuit close to the connector and controller to reduce susceptibility to ESD and ground potential differences.
Recommended
Point-of-Sale Equipment
The MAX232CASE+ is suitable for point-of-sale terminals and peripherals that retain a DB9-based RS-232 service or data port. A microcontroller can communicate through the logic-level receiver outputs while the transmitters create RS-232 levels for attached scanners, printers, or weighing equipment. The device's 2/2 channel arrangement can handle two independently connected serial paths, and its full-duplex operation supports simultaneous transmission and reception. Designers should use a 4.5 V to 5.5 V supply, select capacitors with suitable voltage rating and temperature characteristics, and include the ±2 kV ESD protection capability in the external port-protection strategy when cables leave the enclosure.
Recommended
Test and Measurement Systems
The MAX232CASE+ can bridge a laboratory instrument or automated test fixture to a computer or embedded controller through an RS-232 command interface. Its 120 kbps data rate accommodates configuration files, measurement results, and status commands, while 500 mV receiver hysteresis improves noise rejection in bench environments. The 16-pin SOIC package also allows reuse of an existing small-footprint board layout. Keep the interface ground referenced to the system ground, verify the transmitter's approximately ±9 V output behavior under load, and use the manufacturer's charge-pump capacitor values to preserve stable operation and minimize conducted noise on the logic-side rails.
Recommended
Embedded Serial Service Ports
The MAX232CASE+ is useful in embedded equipment that retains a service connector for configuration, firmware download, or diagnostic commands. Its dual transmit and receive channels allow two serial links to be implemented without adding another transceiver, and the 120 kbps rate is well matched to human-paced console traffic. Because the catalog part is obsolete, an existing design can use a qualified family alternative when the footprint and pin functions match. A new embedded platform should prioritize an active low-power transceiver, but any migration must verify the charge-pump capacitor pinout, supply current, receiver thresholds, and whether shutdown or supply-sensing functions are required.
Recommended
Security and Access Systems
The MAX232CASE+ can support RS-232 connections in access-control readers, alarm panels, and security-system service tools where a controller or service laptop uses a legacy serial protocol. Its full-duplex 2/2 arrangement permits simultaneous command transmission and sensor or status reception, and the 500 mV receiver hysteresis helps avoid interpreting small noise disturbances as valid commands. For installations exposed to electrostatic discharge or long cables, retain the MAX232 family's ±2 kV ESD capability and place the transceiver near the connector. Keep external protection and chassis grounding separate from logic ground where required by the system architecture.
Recommended
Instrumentation and Diagnostics
The MAX232CASE+ suits diagnostic equipment that transfers measurement logs, calibration records, or service information over RS-232. The 120 kbps limit is sufficient for many text-based protocols and low-bandwidth binary records, while two transmitters and two receivers allow connection to more than one device or permit one channel to be reserved for diagnostics. The interface should be powered from a stable 5 V rail because charge-pump operation depends on adequate supply headroom. Use short, properly terminated cabling where possible, observe common-mode limits, and verify the external capacitor values and polarity against the manufacturer datasheet before reusing the circuit in new instrumentation.
Recommended
Recommended Products Summary
Engineering reference data for MAX232CASE+ — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | MAX232CSE+ | MAX232CASE+T | MAX232ACSE+T | MAX232ESE+ | MAX232EWE+ |
|---|---|---|---|---|---|---|
| Package | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC |
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated |
| Transceiver Configuration | 2 transmitters and 2 receivers | 2 transmitters and 2 receivers | 2 transmitters and 2 receivers | 2 transmitters and 2 receivers | 2 transmitters and 2 receivers | 2 transmitters and 2 receivers |
| Maximum Data Rate | 120 kbps | 120 kbps | 120 kbps | 120 kbps | 120 kbps | 120 kbps |
| Supply Voltage | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V |
| Operating Temperature | 0°C to 70°C | Commercial-temperature grade; exact range not stated for this suffix | -40°C to 125°C | -40°C to 125°C | Extended-temperature grade; exact range not stated for this suffix | Extended-temperature grade; exact range not stated for this suffix |
| Lifecycle Status | Obsolete | Active distributor catalog option | Listed with active inventory and pricing | Listed for comparison | Family option; exact current status not stated | Family option; exact current status not stated |
| Power and Shutdown Features | MAX232 5 V transceiver; shutdown function not stated | MAX232 5 V transceiver; shutdown function not stated | MAX232 5 V transceiver; shutdown function not stated | MAX232A low-power family with shutdown functionality | MAX232 E-grade family; exact shutdown configuration not stated | MAX232 E-grade family; exact shutdown configuration not stated |
| RS-232 Output Levels | Approximately ±9 V | Approximately ±9 V | Approximately ±9 V | MAX232A family RS-232 output; confirm under load | MAX232 family output; confirm under load | MAX232 family output; confirm under load |
Key Differentiators
- Maintains the established MAX232 2/2 RS-232 interface (vs MAX3232CSE+)
- Exact commercial-temperature original catalog reference (vs MAX232CASE+T)
- Active-catalog same-footprint maintenance candidate (vs MAX232CSE+)
- Lower-power option available without changing the basic interface family (vs MAX232ACSE+T)
Design Notes
Place the four charge-pump capacitors directly between their numbered IC pins and keep their ground-side return paths short and compact. Use the capacitor values, type, voltage rating, and temperature coefficient specified by the manufacturer for the selected family member. Extra-long capacitor traces can increase loop inductance and allow charge-pump ripple to couple into nearby logic. Preserve the SOIC-16 land pattern, but recheck pin functions when replacing the obsolete MAX232CASE+ with a MAX232A or other shutdown-capable variant.
Do not approve a replacement based only on its SOIC-16 footprint. Compare the supply range, 2/2 channel allocation, receiver thresholds, data rate, transmitter levels, shutdown behavior, charge-pump capacitor values, and temperature grade. A MAX232CASE+ board can normally be inspected for shared supply, ground, driver, receiver, and capacitor pins, but an MAX232A-family substitute may use shutdown-related pins differently. Confirm every connection against the manufacturer pin-description table and schematic before production release.
Route the RS-232 connector-side traces away from clocks, switching-node connections, and sensitive analog inputs. Provide a direct return path for the interface ground, and consider the ground-potential difference that can develop between connected equipment. The receiver's 500 mV hysteresis helps reject noise, but it does not replace proper shielding, cable routing, or connector-side ESD protection. Keep the transceiver close to the connector where practical to minimize exposed high-impedance receiver traces.
Decouple the 5 V supply locally and verify that its operating range remains within 4.5 V to 5.5 V under load. The MAX232 family's internal charge pump creates the bipolar voltages required for RS-232 transmission, so insufficient supply headroom or excessive source impedance can affect output behavior. Place the manufacturer's recommended bypass capacitor near the supply pins and evaluate the external capacitors for adequate voltage rating. Do not substitute lower capacitance values solely to reduce board area.
Compliance Information
The manufacturer family is identified as intended for EIA/TIA-232E and V.28/V.24 interfaces. Specific material-compliance declarations for the obsolete MAX232CASE+ ordering code were not identified.