MAX306EPI+ - 16:1 Precision CMOS Multiplexer | Analog Devices
MPN: MAX306EPI+ ✓ ActiveMAX306EPI+ Overview
An analog multiplexer is an interface IC that connects multiple signal sources to a common output through electronically controlled switches. The MAX306 belongs to the analog switch and multiplexer hierarchy, where low on-resistance, low leakage, fast switching, and controlled charge injection help preserve the integrity of sampled or measured signals. Its 16:1 configuration supports channel selection in instrumentation, data acquisition, test systems, and control equipment.
The MAX306EPI+ features on-resistance below 100 ohm, channel matching within 5 ohm, and no more than 7 ohm resistance variation across the specified analog signal range. Off leakage remains below 2.5 nA at 85°C, while switching transition time is below 250 ns. Charge injection below 10 pC and ESD protection greater than 2000 V make the device suitable for precision analog routing where switching transients and leakage must remain controlled.
The MAX306 and MAX307 are monolithic CMOS devices optimized for precision multiplexing. The MAX306EPI+ provides a 16-channel, 16:1 arrangement in the MAX306 family, while related MAX307 configurations support dual 8-channel operation. Matching within each device limits channel-to-channel gain-like error, while the flat on-resistance characteristic helps preserve signal integrity as the selected input voltage changes.
Typical uses include multiplexed sensor acquisition, automated test equipment, instrumentation signal routing, industrial control systems, and laboratory measurement setups. The device is especially appropriate when many analog inputs must share a limited number of converter or amplifier inputs. Its combination of fewer than 250 ns switching time and less than 10 pC charge injection supports faster measurement sequences while limiting settling requirements after channel selection.
For PCB implementation, keep the selected analog source and multiplexer output paths short, provide a stable ground reference, and place input protection or filtering components where their capacitance will not excessively degrade switching time. Account for injected charge during each transition and allow adequate settling time before sampling when the source impedance is high.
This product record combines the manufacturer specifications with a package-focused pinout reference, drop-in comparison, application guidance, and design notes. It is intended to help engineers evaluate the MAX306EPI+ for precision analog routing without overlooking switching, leakage, charge-injection, and PCB-layout constraints.
Drop-in alternatives for MAX306EPI+ — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Variants in this series
Same-series models that are drop-in compatible with MAX306EPI+ (same form factor and footprint) — differing in Multiplexer Configuration, Off Leakage.
MAX306CPI
✅ Drop-In📋 Reference alternative (not in catalog)
MAX306EPI+ Specifications
| Product Type | Precision CMOS analog multiplexer |
| Number of Circuits | 1 circuit |
| Multiplexer Configuration | 16:1 |
| Number of Channels | 16 channels |
| On-Resistance | Less than 100 ohm |
| On-Resistance Matching | Within 5 ohm between channels |
| On-Resistance Variation | 7 ohm maximum across specified analog signal range |
| Off Leakage | Less than 2.5 nA at 85°C |
| Transition Time | Less than 250 ns |
| Charge Injection | Less than 10 pC |
| ESD Protection | Greater than 2000 V |
| Package | 28-pin PDIP |
| Mounting Type | Through-hole |
| Technology | CMOS |
MAX306EPI+ 28-pin pdip Pin Configuration Guide
Pin configuration for MAX306EPI+ (28-pin pdip package). Pin numbering, functions, and connection diagrams are defined in the manufacturer datasheet. Refer to it for the exact footprint and soldering guidelines.
No detailed pinout data available for MAX306EPI+.
Refer to the datasheet for full pin configuration.
Typical Applications
MAX306EPI+ is suitable for 6 applications: Precision Data Acquisition, Automated Test Equipment, Sensor Signal Multiplexing, Laboratory Instrumentation, Industrial Process Control, Battery-Powered Monitoring.
Precision Data Acquisition
The MAX306EPI+ fits a 16-input analog measurement front end because it routes one of 16 signals to a shared converter or amplifier. Its on-resistance below 100 ohm and channel matching within 5 ohm help limit input-dependent attenuation and channel-to-channel error, while transition time below 250 ns supports faster scan rates. Use the manufacturer pin table to assign address and enable controls, and allow converter and amplifier settling time after each switch event.
Recommended
Automated Test Equipment
The MAX306EPI+ is appropriate for automated test systems that sequentially connect many test points to a common measurement channel. The 16:1 architecture reduces external routing hardware, and the less-than-250 ns transition time enables quick point selection. Its less-than-10 pC charge injection and below-2.5 nA off leakage at 85°C help protect low-level measurements, although fixture capacitance and high source impedances can lengthen the required settling interval.
Recommended
Sensor Signal Multiplexing
The MAX306EPI+ can consolidate outputs from multiple sensors before conversion or amplification. Matching within 5 ohm helps maintain consistency between channels, while low off leakage below 2.5 nA at 85°C reduces errors from inactive sensor paths. Place sensitive sensor lines away from digital address-control traces, use a quiet ground plane, and filter at the downstream amplifier when sensor bandwidth or source impedance makes charge injection significant.
Recommended
Laboratory Instrumentation
The MAX306EPI+ supports laboratory instruments that need to route several measurement ranges or input terminals through a common analog chain. Its less-than-100-ohm on-resistance provides a relatively low insertion resistance, and the flat resistance characteristic stays within 7 ohm across the specified analog range. For precision bench equipment, include the multiplexer’s charge injection in the uncertainty budget and select a settling period based on source impedance and downstream filter characteristics.
Recommended
Industrial Process Control
The MAX306EPI+ can route multiple process-control sensor inputs into a controller or signal-conditioning channel when sequential sampling is acceptable. The 16:1 configuration reduces analog input count, while low leakage and closely matched resistance improve consistency between channels. Design the analog traces for low noise, maintain a continuous ground reference, and verify the complete temperature range and ESD requirements of the industrial enclosure before releasing the design.
Recommended
Battery-Powered Monitoring
The MAX306EPI+ is useful in monitoring equipment that must measure several physical quantities through a shared analog front end. Its compact 28-pin PDIP package is practical for through-hole industrial and instrumentation boards, while the sub-250 ns switching time allows rapid measurement scans. Validate supply-current limits and logic levels in the complete design, and account for off leakage and injected charge when sensors have very high source impedances or long measurement intervals.
Recommended
Recommended Products Summary
Engineering reference data for MAX306EPI+ — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | MAX306CPI |
|---|---|---|
| Package | 28-pin PDIP | 28-pin PDIP |
| Brand | Analog Devices | Analog Devices |
| Multiplexer Configuration | 16:1 | 16:1 |
| Number of Channels | 16 channels | 16 channels |
| Number of Circuits | 1 circuit | 1 circuit |
| On-Resistance | Less than 100 ohm | Less than 100 ohm |
| On-Resistance Matching | Within 5 ohm between channels | Within 5 ohm between channels |
| Off Leakage | Less than 2.5 nA at 85°C | Less than 2.5 nA at 85°C |
| Transition Time | Less than 250 ns | Less than 250 ns |
| Charge Injection | Less than 10 pC | Less than 10 pC |
| ESD Protection | Greater than 2000 V | Greater than 2000 V |
| Temperature Grade | E grade | C grade |
Key Differentiators
- Closest documented same-footprint replacement (vs MAX306CPI)
- 16 inputs through one analog output (vs MAX307CPI)
- Low channel-to-channel resistance mismatch (vs MAX306CPI)
Design Notes
Account for the less-than-10-pC charge injection at every channel transition when the source impedance is high. The resulting voltage error depends on source impedance, downstream capacitance, and measurement timing. For a precision acquisition path, select the new channel, wait for the converter and amplifier to settle, and acquire the sample only after the transient has decayed.
Route analog source pins and the common analog output as short traces with a continuous ground reference. Keep the MAX306EPI+ address and enable traces away from sensitive analog paths, use a solid ground plane, and place any input filtering capacitors close to the downstream amplifier when capacitance would otherwise slow the less-than-250-ns switching behavior.
Do not treat the 16:1 switching speed as the complete acquisition time. Include address-control delay, multiplexer settling, converter acquisition, and amplifier settling in the scan-period budget. High source impedance and long PCB traces can amplify charge-injection errors, so validate those conditions with the actual sensor, cable, and measurement front end.
Use the manufacturer pin-description table to identify the 28-pin PDIP numbering and preserve a clear pin-1 orientation on the PCB. Keep the common and selected analog terminals away from switching-control nets where possible. A grounded guard or shielding arrangement may be useful for high-impedance signals, but it must not disturb the multiplexer’s specified operating conditions.
Compliance Information
The MAX306 family is identified as a production product. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status require confirmation for the exact MAX306EPI+ ordering code.