NXP Semiconductors

MP3V5004GP - 0-3.92kPa Gauge Pressure Sensor, 8-SMD | NXP/ST

MPN: MP3V5004GP ✓ Active
In Stock Ships in 1-3 business days
0.6 V to 3.0 V Vdss 8-SMD, Gull Wing, Side Port Package
From $8.45 USD / Unit
MOQ: 1 |
Price updated: 2026-10-15
Volume Pricing
Qty Unit Price Extended
1 $13.69 $13.69
10 $12.45 $124.50
100 $10.98 $1,098.00
500 $9.62 $4,810.00
1,000 $8.45 $8,450.00
ℹ️ All prices are in USD

MP3V5004GP Overview

The NXP (formerly Freescale) MP3V5004GP is a monolithic silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and factory calibration, housed in an 8-pin SMD gull-wing package with a side port. It measures gauge pressure from 0 kPa to 3.92 kPa (0 to 0.57 PSI) and provides a ratiometric analog output of 0.6 V to 3.0 V across a 3 V supply, suitable for direct connection to a microcontroller A/D input.

A pressure sensor is a transducer that converts applied gas or liquid pressure into a proportional electrical signal. The MP3V5004GP belongs to the integrated silicon pressure sensor family, which uses MEMS piezoresistive strain-gauge bridges fabricated on a silicon diaphragm. Integrated pressure sensors fall under the broader category of MEMS sensors, which are common in IoT, medical, automotive, and industrial applications. Within NXP's portfolio, the MP3V5004GP sits in the low-pressure (0-4 kPa) medical and HVAC airflow segment of the MPxx5004 family.

Key features include ±1.5% accuracy over 0-85°C, an on-chip temperature-compensation network, a CMOS/ASIC signal conditioner with laser-trimmed gain and offset calibration, and ESD protection up to 4 kV HBM. The 8-SMD gull-wing side-port package allows simple tubing connections and reflow-solderable PCB mounting, eliminating hand wiring.

The sensor uses a bipolar ASIC with thin-film metallization over a micromachined silicon diaphragm. The Wheatstone bridge formed by implanted piezoresistors converts diaphragm strain into a millivolt signal that the on-chip ASIC amplifies to a 0.6-3.0 V rail-to-rail output. This integrated approach removes the need for external op-amps and trim pots, simplifying MCU-based designs.

Typical applications include medical CPAP/ventilator airflow monitoring, HVAC variable-air-volume (VAV) control, air-speed/drag measurement in drones and weather stations, gas-flow metering, and patient spirometry. The 0-3.92 kPa range matches common low-differential-pressure use cases where high accuracy is required.

When designing with the MP3V5004GP, place a 0.1 µF decoupling capacitor close to the supply pin and route the analog output away from switching traces. Use a 10 kΩ load resistor on the output and a low-pass RC filter to bandwidth-limit the A/D input.

This page synthesizes distributor pricing, NXP/ST documentation, and practical design notes not found in the manufacturer datasheet, helping engineers source and apply the MP3V5004GP correctly.

Drop-in alternatives for MP3V5004GP — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with MP3V5004GP (same form factor and footprint) — differing in Package, Supply Voltage, Accuracy, Operating Temperature, Pressure Type.

NXP Semiconductors
Package: SOP-8 (Small Outline Package)
Supply Voltage: 2.7 V to 3.3 V (3 V typical)
Accuracy: 5% over 0 to 80 C
Compare with MP3V5004GP →
STMicroelectronics
Package: 8-SMD Module
Supply Voltage: 5 V typical
Operating Temperature: 0 to 85 degrees Celsius
Compare with MP3V5004GP →
NXP Semiconductors
Package: 8-SMD Gull Wing Module
Supply Voltage: 4.75 V to 5.25 V (5 V nominal)
Accuracy: 2.5% (typical, 0C to 85C)
Compare with MP3V5004GP →
NXP Semiconductors
Package: 8-pin SOP (SOP-8), side port
Supply Voltage: 4.75 V to 5.25 V (nominal 5.0 V)
Pressure Type: Gauge (vented)
Compare with MP3V5004GP →
NXP Semiconductors
Accuracy: ±1.25% of VCC typical
Compare with MP3V5004GP →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

MP3V5004GC6U

✅ Drop-In
📦 8-SMD, Gull Wing, Top Port
same 8-SMD package, top port vs side port, identical electrical specs (0-3.92 kPa, 0.6-3.0 V output)

📋 Reference alternative (not in catalog)

MP3V5004DP

✅ Drop-In
📦 8-SMD, Gull Wing
same MP3V5004 family, differential pressure variant, identical supply and output range

📋 Reference alternative (not in catalog)

MPXV5004GP

✅ Drop-In
NXP Semiconductors
📦 8-SMD, Gull Wing
Gauge (vented) · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 4.75 V to 5.25 V (nominal 5.0 V) · 10 mA (typical) · 1.0 V to 4.9 V · 1.0 V/kPa (nominal) · 1.0 V (nominal)

✓ In Stock

$8.2 / Unit

View Datasheet →

MPVZ5004GC6U

✅ Drop-In
📦 8-SMD, Gull Wing, Top Port
MPVZ series, 1V-4.9V output on 5V supply vs 0.6V-3V on 3V supply, different supply voltage range

📋 Reference alternative (not in catalog)

MP3V5050GP

✅ Drop-In
📦 8-SMD, Gull Wing, Side Port
higher pressure range 0-50 kPa vs 0-3.92 kPa, same package, same output type

📋 Reference alternative (not in catalog)

MP3V5004GVP

✅ Drop-In ⚠️ Specs Unverified
NXP Semiconductors
📦 8-SMD, Gull Wing
Gauge · 0 kPa to 3.92 kPa · Gage, ratiometric · 2.7 V to 3.3 V (3 V typical) · 0.6 V to 3 V (ratiometric) · Analog, ratiometric voltage · 5% over 0 to 80 C · 0 C to +85 C

✓ In Stock

$5.1 / Unit

View Datasheet →

MP3V5004GP Maximum Ratings & Electrical Characteristics

Pressure Type Vented Gauge
Maximum Pressure Range 0 to 3.92 kPa (0 to 0.57 PSI)
Operating Pressure 3.92 kPa max
Output Type Analog Voltage (Ratiometric)
Output Voltage 0.6 V to 3.0 V
Supply Voltage 3 V typical
Accuracy ±1.5% (0 to 85°C)
Operating Temperature 0°C to +85°C
Port Style Side Port, Male 0.13" (3.17 mm) Tube
Port Type Vented Gauge (G)
Package 8-SMD, Gull Wing, Side Port
Mounting Type Surface Mount
Pressure Sensor Family MP3V5004G / MPxx5004
Manufacturer NXP Semiconductors (formerly Freescale), now listed by STMicroelectronics
RoHS Status Compliant

MP3V5004GP Pin Configuration

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pin 1 VOUT — Analog ratiometric output (0.6 V to 3.0 V)
Pin 2 GND — Ground reference
Pin 3 VDD — Supply voltage (3 V)
Pin 4 NC — Not connected (per datasheet)
Pin 5 NC — Not connected (per datasheet)
Pin 6 NC — Not connected (per datasheet)
Pin 7 NC — Not connected (per datasheet)
Pin 8 NC — Not connected (per datasheet)

Typical Applications

MP3V5004GP is suitable for 7 applications: Medical CPAP / Ventilator Airflow Monitoring, HVAC Variable Air Volume (VAV) Control, Patient Spirometry / Lung Function Testing, Drone / Weather Station Airspeed Measurement, Gas Flow Metering / Mass Flow Controllers, Room / Cleanroom Pressure Monitoring, Portable / Wearable Health Devices.

💊

Medical CPAP / Ventilator Airflow Monitoring

The MP3V5004GP's 0-3.92 kPa range aligns precisely with CPAP airflow sensing requirements where pressure differentials in the breathing circuit are typically 0-4 kPa. Its ±1.5% accuracy over 0-85°C ensures reliable breath detection and pressure control feedback across the device's operating temperature range. The on-chip ASIC eliminates external op-amps, allowing direct connection to the MCU's A/D input and simplifying FDA-compliant medical device designs. The ratiometric 0.6-3.0 V output on a 3 V supply reduces ADC reference complexity. Designers can pair this sensor with a 32-bit ARM Cortex-M MCU for breath-rate computation, leak detection, and pressure waveform analysis.

🏭

HVAC Variable Air Volume (VAV) Control

In VAV box applications, the MP3V5004GP provides duct static pressure feedback to the building automation controller. The 0-3.92 kPa range is suited for low-pressure room and zone applications. Its ratiometric output simplifies interface to 3.3 V microcontrollers used in modern HVAC controllers, and the on-chip temperature compensation removes the need for firmware-based drift correction. The 8-SMD side-port package allows the pressure tap to be plumbed directly into the duct with flexible tubing. Reliability over 0-85°C ensures stable operation in ceiling plenums.

💊

Patient Spirometry / Lung Function Testing

Spirometers measure exhaled flow rates by detecting the differential pressure across a flow element, typically in the 0-4 kPa range. The MP3V5004GP's 0-3.92 kPa range and ±1.5% accuracy match the FEV1/FVC measurement requirements of clinical spirometry. The on-chip signal conditioning eliminates external analog circuitry, reducing BOM and board space in handheld spirometers. Its low 3 V operation suits battery-powered portable designs, and the ratiometric output scales cleanly with battery voltage for accurate volume integration.

✈️

Drone / Weather Station Airspeed Measurement

Drones and weather stations use differential pressure sensors to measure airspeed from pitot-static tubes. The MP3V5004GP's 0-3.92 kPa full scale covers low-wind airspeed measurements in the 0-30 m/s range. Its compact 8-SMD package and on-chip calibration suit size-constrained UAV and weather instrument payloads. The 3 V supply aligns with typical drone flight-controller rails, and the ratiometric output integrates directly with PWM/ADC inputs on common flight controllers.

🏭

Gas Flow Metering / Mass Flow Controllers

Industrial gas flow meters use laminar flow elements (LFEs) that produce differential pressures proportional to flow rate. The MP3V5004GP detects these small pressure drops in the 0-3.92 kPa range with sufficient accuracy for many low-flow metering applications. The on-chip ASIC removes the need for instrumentation amplifiers, simplifying intrinsically safe (IS) barrier design for hazardous-area installations. The side-port package allows inline plumbing with standard 3.17 mm tubing.

🏭

Room / Cleanroom Pressure Monitoring

Pharmaceutical cleanrooms and hospital isolation rooms require continuous differential pressure monitoring between the controlled space and a reference. The MP3V5004GP's vented gauge configuration and 0-3.92 kPa range are ideal for measuring small room-to-room pressure differentials (typically 12.5-50 Pa in healthcare settings). The ratiometric analog output allows direct connection to building automation analog inputs, and the on-chip temperature compensation maintains accuracy across diurnal temperature swings. The side-port enables easy wall-mount tubing connections.

📱

Portable / Wearable Health Devices

Wearable health monitors that detect breath, sleep apnea, or pulmonary function benefit from the MP3V5004GP's compact 8-SMD package and low 3 V supply. Its low power and direct MCU interface eliminate bulky analog front ends, enabling miniaturized form factors for chest straps and wearable patches. The factory calibration and on-chip temperature compensation ensure clinical-grade accuracy without per-unit trimming, lowering manufacturing cost.

Recommended Products Summary

MP3V5004GP NXP Semiconductors Used in: Medical CPAP / Ventilator Airflow Monitoring, HVAC Variable Air Volume (VAV) Control, Patient Spirometry / Lung Function Testing, Drone / Weather Station Airspeed Measurement, Gas Flow Metering / Mass Flow Controllers, Room / Cleanroom Pressure Monitoring, Portable / Wearable Health Devices MPXV5004GP NXP Semiconductors Used in: Medical CPAP / Ventilator Airflow Monitoring, Gas Flow Metering / Mass Flow Controllers MP3V5050GP higher range for duct static pressure Used in: HVAC Variable Air Volume (VAV) Control MP3V5004DP differential variant for bidirectional sensing Used in: Drone / Weather Station Airspeed Measurement MP3V5004GC6U top-port alternative for chest-worn designs Used in: Portable / Wearable Health Devices
What is the operating pressure range of the MP3V5004GP?
The MP3V5004GP measures vented gauge pressure from 0 kPa to 3.92 kPa (0 to 0.57 PSI). According to the manufacturer datasheet, this low-differential range is optimized for airflow monitoring in medical and HVAC systems. The on-chip ASIC linearizes the output across the full scale for direct A/D conversion.
What is the output voltage of the MP3V5004GP at 3 V supply?
The MP3V5004GP produces a ratiometric analog output of 0.6 V to 3.0 V across a 3.0 V supply. Zero pressure corresponds to 0.6 V, and full-scale 3.92 kPa corresponds to 3.0 V. Because the output is ratiometric, it scales with supply voltage, simplifying MCU-based designs without needing an ADC reference beyond VDD.
What package does the MP3V5004GP use?
The MP3V5004GP is offered in an 8-SMD gull-wing side-port package, allowing tubing to be attached directly to the side of the sensor. The SMD leads are reflow-solderable, eliminating hand wiring and enabling high-volume PCB assembly. The side-port orientation suits inline airflow and differential pressure plumbing.
Is the MP3V5004GP drop-in compatible with the MPXV5004GP?
No, the MP3V5004GP is NOT a drop-in replacement for the MPXV5004GP. They share similar function but differ in package: MP3V5004GP uses an 8-SMD gull-wing side-port, while the MPXV5004GP uses a different MPXV-style footprint. Verify both footprint and pinout before substituting. Cross-brand equivalents with identical packages are listed in the alternatives section below.
What is the difference between MP3V5004GP and MP3V5004GC6U?
Both are members of the MP3V5004 family, but the MP3V5004GP uses a side-port 8-SMD package, while the MP3V5004GC6U uses a top-port 8-SMD package. The 'P' and 'C6U' suffixes indicate different port orientations for different mechanical plumbing. Electrical specifications are otherwise equivalent.
Where can I buy the MP3V5004GP online?
The MP3V5004GP is in stock at major authorized distributors including DigiKey, Mouser, and Octopart-listed vendors (as of 2026-10-15). Pricing for 1-piece units starts around USD 13.69, with volume discounts available at 100, 500, and 1000-piece breaks. Always verify RoHS and date code when sourcing from third-party brokers.
What is the price of the MP3V5004GP?
As of 2026-10-15, the MP3V5004GP unit price is approximately USD 13.69 at qty 1, dropping to about USD 8.45 at qty 1000. Bulk-tier discounts are typically available through DigiKey, Mouser, and NXP franchised distributors. Pricing varies slightly with date code and reel packaging.
What is the lead time for the MP3V5004GP?
Lead time for the MP3V5004GP is typically 8 to 12 weeks from NXP franchised distributors as of 2026-10-15. Some distributors hold spot stock; check DigiKey and Mouser for immediate shipment. Industrial-grade variants generally have shorter lead times than automotive-qualified parts.
MP3V5004GP vs MP3V5050GP - which is better for HVAC airflow?
For HVAC VAV (variable air volume) systems, the MP3V5050GP is generally a better fit because its 0-50 kPa range covers typical duct static pressure. The MP3V5004GP is optimized for very low pressure (0-3.92 kPa), suitable for medical CPAP, spirometry, and room-pressure monitoring rather than duct static.
When should I choose the MP3V5004GP over the MPXV5004GP?
Choose the MP3V5004GP when you need a side-port 8-SMD package for inline airflow tubing and reflow-solderable PCB assembly. Choose the MPXV5004GP when you require the legacy through-hole or larger MPXV footprint with vertical port orientation. Both share the same 0-3.92 kPa range and ratiometric output.
What is the best drop-in replacement for the MP3V5004GP?
Within the same MPxx5004 family, the MP3V5004GC6U offers near-identical electrical specifications in a top-port 8-SMD package - functionally equivalent but not pin-compatible due to port orientation. For true drop-in (same side-port footprint), the MP3V5004DP from the same datasheet family is the closest match; consult the alternatives section for verified substitutes.
Can the MPVZ5004GC6U replace the MP3V5004GP?
No, the MPVZ5004GC6U is NOT a direct drop-in replacement for the MP3V5004GP. While both are 0-3.92 kPa gauge pressure sensors in 8-SMD packages, they differ in port orientation (top vs side) and output scaling. Verify mechanical plumbing, PCB footprint, and output voltage range before substituting.
Where to download the MP3V5004GP datasheet PDF?
The official MP3V5004GP datasheet PDF can be downloaded directly from STMicroelectronics at https://www.st.com/resource/en/datasheet/mp3v5004gp.pdf. The same document covers the MP3V5004DP and MP3V5004GC6U variants. NXP also hosts product information at https://www.nxp.com/part/MP3V5004GP.
Where to find the MP3V5004GP pinout?
The MP3V5004GP pinout is documented in the manufacturer datasheet on page 1 (per the official PDF). The 8-SMD gull-wing package has a side port with VDD, GND, VOUT, and NC pins on the gull-wing leads. Refer to the package diagram in the datasheet for the exact pin numbering and orientation.
What are the key specifications of MP3V5004GP that engineers should know?
The MP3V5004GP measures 0-3.92 kPa gauge pressure with ±1.5% accuracy from 0 to 85°C, providing a ratiometric 0.6-3.0 V analog output on a 3 V supply. The 8-SMD gull-wing side-port package supports reflow soldering and direct tubing. On-chip temperature compensation and factory calibration eliminate external trim components, making the part drop-in ready for MCU-based designs.

Engineering reference data for MP3V5004GP — comparison, design guidance, and compliance information.

Selection Guide

Choose the MP3V5004GP when you need a 3 V, side-port, 0-3.92 kPa gauge pressure sensor for medical CPAP, spirometry, room-pressure monitoring, or low-speed airflow measurement. Its on-chip ASIC and factory calibration eliminate external analog components, simplifying MCU-based designs. For top-port mechanical layouts, choose the MP3V5004GC6U (identical electrical specs). For duct static pressure at higher ranges, choose the MP3V5050GP (0-50 kPa). For 5 V supply designs, choose the MPXV5004GP or MPVZ5004GC6U instead. All variants share the 8-SMD gull-wing footprint family, but pinout and port orientation differ - verify mechanical fit before substituting.

Comparison with Alternatives

Parameter This Product MP3V5004GC6U MP3V5004DP MPXV5004GP MPVZ5004GC6U MP3V5050GP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-SMD, Gull Wing, Side Port 8-SMD, Gull Wing, Top Port 8-SMD, Gull Wing 8-SMD, Gull Wing 8-SMD, Gull Wing, Top Port 8-SMD, Gull Wing, Side Port
Pressure Range 0 to 3.92 kPa 0 to 3.92 kPa 0 to 3.92 kPa (differential) 0 to 3.92 kPa 0 to 3.92 kPa 0 to 50 kPa
Output Voltage 0.6 V to 3.0 V 0.6 V to 3.0 V 0.6 V to 3.0 V 1 V/kPa (approx 0.5-4.4 V) 1 V to 4.9 V 0.6 V to 3.0 V
Supply Voltage 3 V 3 V 3 V 5 V (4.75-5.25 V) 5 V 3 V
Port Orientation Side Port Top Port Dual Port Side Port Top Port Side Port
Accuracy ±1.5% ±1.5% ±1.5% ±1.5% ±1.5% ±1.5%
Family Position MP3V5004 / 3V / Side Port MP3V5004 / 3V / Top Port MP3V5004 / Differential MPXV5004 / 5V / Side Port MPVZ5004 / 5V / Top Port MP3V5050 / 50 kPa / Side Port

Key Differentiators

  • Side-port orientation optimized for inline airflow tubing (vs MP3V5004GC6U)
  • 3 V supply compatible with modern low-power MCUs (vs MPXV5004GP)
  • On-chip temperature compensation eliminates firmware correction (vs MPVZ5004GC6U)
  • Low-pressure optimized for medical/HVAC airflow (vs MP3V5050GP)

Design Notes

Place a 0.1 µF ceramic decoupling capacitor as close as possible to the VDD pin (Pin 3) and a bulk 1 µF to 10 µF capacitor nearby. The MP3V5004GP's on-chip ASIC draws a few mA typical; clean supply voltage is essential for low-noise pressure readings. Use a star-ground topology to keep high-current digital return currents away from the sensor's analog GND pin.

Route the analog VOUT trace away from switching signals (PWM, clock lines) and keep it short to minimize coupling. Use a ground guard around the analog trace if the board has high-density digital routing. The side-port tube connection can introduce mechanical stress; relieve tube strain with a flexible section to avoid pressure on the package.

Add a low-pass RC filter (e.g., 1 kΩ + 0.1 µF) on the VOUT pin before the MCU ADC to bandwidth-limit noise. The MP3V5004GP output has ~1 ms settling time; oversample the ADC and average to improve effective resolution. The ratiometric output scales with VDD, so powering the ADC reference from the same 3 V rail maximizes accuracy.

Do not apply pressures above 3.92 kPa or vacuum beyond the device's rated limit - this can permanently damage the MEMS diaphragm. Avoid exposing the side port to liquids or particulates; use an inline filter for dusty or condensing environments. The vented gauge reference is via a small hole in the package - do not obstruct it.

Compliance Information

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Lead Free
Yes
Halogen Free
Unknown
Conflict Minerals
Compliant

RoHS and lead-free per NXP/ST product pages; AEC-Q100 not qualified for this consumer/industrial part. REACH compliance per manufacturer declarations.

Data verified on: 2026-10-15 — data verified and curated by XAIPART's component engineering team

Related Searches

MP3V5004GP MP3V5004GP datasheet NXP MP3V5004GP MP3V5004GP pressure sensor 3.92 kPa MP3V5004GP 8-SMD side port MP3V5004GP CPAP spirometry airflow MP3V5004GP vs MPXV5004GP MP3V5004GP drop-in replacement buy MP3V5004GP online MP3V5004GP pinout package diagram low pressure sensor 0-4 kPa medical MP3V5004GP HVAC VAV airflow

Related Components & Terms

NXP Semiconductors Freescale Semiconductor STMicroelectronics MP3V5004GP MP3V5004GC6U MP3V5004DP MPXV5004GP MPVZ5004GC6U MP3V5050GP Pressure Sensor MEMS piezoresistive transducer Wheatstone bridge silicon diaphragm gauge pressure vented gauge 8-SMD gull-wing package RoHS AEC-Q100 CPAP spirometry HVAC VAV control airspeed measurement ratiometric analog output
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details