MPXV5004GVP Overview

The NXP MPXV5004GVP is a monolithic silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, providing an analog voltage output proportional to applied vented gauge pressure over a 0 kPa to 3.92 kPa (0 to 0.57 PSI) range. Housed in an 8-SMD module with a vertical port, it operates from a single 4.75 V to 5.25 V supply and delivers a nominal 1 V ~ 4.9 V ratiometric analog output suitable for direct connection to a microcontroller ADC. The MPXV5004GVP belongs to NXP's MPxx5004 family of integrated pressure sensors designed for applications employing A/D inputs.

A pressure sensor transducer converts an applied physical pressure into a measurable electronic signal. The MPXV5004GVP is a vented gauge sensor, meaning it measures pressure relative to ambient atmospheric pressure through a vented reference side, making it ideal for applications where the surrounding barometric pressure is the natural zero reference. As a category, it sits within the hierarchy: pressure sensor -> sensor -> transducer -> electronic component, and is widely deployed in medical, HVAC, and consumer flow/level measurement.

Key features include on-chip temperature compensation and calibration over 0°C to 85°C, ratiometric analog voltage output, monolithic silicon construction using advanced micromachining and thin-film metallization, and a robust 8-SMD module with vertical port for easy tube/fitting attachment. The device integrates a sensitive implanted strain gauge with bipolar signal-conditioning circuitry on a single die. The combination of high accuracy (±1.25% typical), integrated calibration, and analog output simplifies host firmware by removing the need for complex digital compensation.

Typical applications include spirometry and respiratory airflow measurement, HVAC variable-air-volume (VAV) controllers, washing machine water-level sensing, altimeters and barometers, and patient monitoring airflow/pressure measurement. The wide supply tolerance (4.75 V to 5.25 V) and low current draw allow battery or line-powered deployments.

When designing with the MPXV5004GVP, ensure the vented reference port is exposed to ambient atmosphere (not sealed) for correct gauge operation, decouple VCC with a 100 nF + 1 µF capacitor pair within 5 mm of the supply pins, and account for the sensor's warm-up time before taking precision readings.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the standalone manufacturer datasheet, with all data last verified on 2026-10-15.

Drop-in alternatives for MPXV5004GVP — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with MPXV5004GVP (same form factor and footprint) — differing in Supply Voltage, Accuracy, Package, Output Voltage Range, Operating Pressure Range.

NXP Semiconductors
Supply Voltage: 3 V typical
Accuracy: ±1.5% (0 to 85°C)
Package: 8-SMD, Gull Wing, Side Port
Compare with MPXV5004GVP →
NXP Semiconductors
Supply Voltage: 2.7 V to 3.3 V (3 V typical)
Accuracy: 5% over 0 to 80 C
Package: SOP-8 (Small Outline Package)
Compare with MPXV5004GVP →
NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V
Package: 8-DIP Module (14.22 mm)
Output Voltage Range: 1.0 V to 4.9 V
Compare with MPXV5004GVP →
NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V DC
Accuracy: ±2.5 % (typical, 10 °C to 50 °C)
Output Voltage Range: 1.0 V to 4.9 V (at 5 V supply)
Compare with MPXV5004GVP →
NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Accuracy: +/- 1.5 percent VFSS
Package: 8-pin DIP, 0.550 inch (13.97 mm), through-hole
Compare with MPXV5004GVP →
NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V (nominal 5.0 V)
Package: 8-pin SOP (SOP-8), side port
Output Voltage Range: 1.0 V to 4.9 V
Compare with MPXV5004GVP →
NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Accuracy: Factory-calibrated (see datasheet for total error band)
Package: 8-pin SOP (Small Outline Package), SMD Gull Wing
Compare with MPXV5004GVP →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

MPXV5004GC7U

✅ Drop-In
NXP Semiconductors
📦 8-SMD Module (vertical port)
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 16 kPa · 4.75 V to 5.25 V (5 V typical) · 1 V to 4.9 V · 1 V/kPa (typical) · +/- 1.5 percent VFSS · 0 C to +85 C

✓ In Stock

$7.1 / Unit

View Datasheet →

MPXV5004GC6U

✅ Drop-In
NXP Semiconductors
📦 8-SMD Module (vertical port)
Vented Gauge · 0 kPa to 3.92 kPa (0 psi to 0.57 psi) · 4.75 V to 5.25 V DC · Analog Voltage (ratiometric) · 1.0 V to 4.9 V (at 5 V supply) · ±2.5 % (typical, 10 °C to 50 °C)

✓ In Stock

$8.3 / Unit

View Datasheet →

MPXV5004GP

✅ Drop-In
NXP Semiconductors
📦 8-SOP (port-side)
Gauge (vented) · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 4.75 V to 5.25 V (nominal 5.0 V) · 10 mA (typical) · 1.0 V to 4.9 V · 1.0 V/kPa (nominal) · 1.0 V (nominal)

✓ In Stock

$8.2 / Unit

View Datasheet →

MPXV5010GC6U

✅ Drop-In
NXP Semiconductors
📦 8-SMD Module
Pressure Sensor, Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · Analog, Ratiometric · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V typical) · Top port, male 0.13 inch (3.17 mm) tube · 8-pin SOP (Small Outline Package), SMD Gull Wing

✓ In Stock

$8.2 / Unit

View Datasheet →

MP3V5004GP

✅ Drop-In
NXP Semiconductors
📦 8-SOP
Vented Gauge · 0 to 3.92 kPa (0 to 0.57 PSI) · 3.92 kPa max · Analog Voltage (Ratiometric) · 0.6 V to 3.0 V · 3 V typical · ±1.5% (0 to 85°C)

✓ In Stock

$8.45 / Unit

View Datasheet →

MPXV5004GVP Maximum Ratings & Electrical Characteristics

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 3.92 kPa (0 to 0.57 PSI)
Supply Voltage (VCC) 4.75 V to 5.25 V
Output Type Analog Voltage (ratiometric)
Output Voltage Range 1.0 V to 4.9 V (nominal, at 5 V VCC)
Output at 0 kPa 0.2 V typical at 5 V supply
Output at Full Scale (3.92 kPa) 4.7 V typical at 5 V supply
Sensitivity 1.0 V/kPa nominal
Accuracy ±1.25% of VCC typical
Operating Temperature Range 0°C to +85°C
Port Type Vertical, male 0.13" (3.3 mm) tube
Package / Case 8-SMD Module
Mounting Type Surface Mount
Technology Piezoresistive, monolithic silicon with thin-film metallization
Termination Solder (SMD)
RoHS Status Compliant
Lead-Free Yes

MPXV5004GVP Pin Configuration

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 VCC — 5 V supply (4.75 V to 5.25 V)
Pin 2 GND — Supply ground
Pin 3 Vout — Analog ratiometric output (0.2 V to 4.7 V)
Pin 4 NC — Not connected (per datasheet)
Pin 5 NC — Not connected (per datasheet)
Pin 6 TRIM — Trim/calibration (per datasheet)
Pin 7 NC — Not connected (per datasheet)
Pin 8 GND_REF — Reference ground (per datasheet)

Typical Applications

MPXV5004GVP is suitable for 6 applications: Spirometry / Respiratory Airflow Sensing, HVAC Variable Air Volume (VAV) Control, Washing Machine Water-Level Sensing, Barometric / Altimeter Measurement, Patient Monitoring Pressure Measurement, Industrial Vacuum / Low-Pressure Process Control.

💊

Spirometry / Respiratory Airflow Sensing

The MPXV5004GVP's 0 to 3.92 kPa range is precisely matched to the differential pressure drop across a pneumotach flow head used in spirometers, CPAP monitors, and ventilator flow paths. Its vented gauge reference tracks ambient barometric pressure, eliminating drift during altitude or weather changes. The 1 V/kPa nominal sensitivity gives ~1 mV resolution per Pa at a 10-bit ADC with 5 V reference, sufficient for tidal-flow waveform reconstruction. Place the sensor across the flow-restriction element with short, equal-length pneumatic taps to minimize common-mode error, and decouple VCC with a 100 nF + 1 µF pair. Unlike bare strain-gauge sensors, the integrated temperature compensation across 0°C to 85°C removes the discrete compensation op-amps the design would otherwise require.

🏭

HVAC Variable Air Volume (VAV) Control

Building-automation VAV boxes measure duct differential pressure to compute airflow and modulate dampers. The MPXV5004GVP's 3.92 kPa full scale covers the 0 to ~0.5 PSI pressure range across an orifice plate in small-to-medium ducts, and its ratiometric analog output interfaces directly to a 5 V microcontroller ADC without an instrumentation front end. The integrated temperature compensation holds accuracy across the 0°C to 85°C commercial building envelope. Mount the sensor with both pneumatic taps to the duct and ensure the vented port remains exposed to ambient atmosphere. Versus a discrete transducer + op-amp chain, the MPXV5004GVP cuts BOM cost and PCB area while keeping long-term drift within calibration.

🏭

Washing Machine Water-Level Sensing

Appliance water-level sensors infer tub fill volume from the hydrostatic head of trapped air. The MPXV5004GVP's 0 to 3.92 kPa range maps directly to typical wash-tub fill heights (0-40 cm of water), and the 1 V/kPa sensitivity yields ~25 mV per cm of water at 5 V, simplifying firmware conversion. Its monolithic silicon diaphragm tolerates humid environments and the small reference vent equalizes barometric pressure so the reading tracks true water level rather than weather. Use a hydrophobic filter on the vented port to keep humidity out of the reference cavity. Compared with mechanical float switches, the MPXV5004GVP gives multi-level resolution for fabric-care algorithms and quieter, more reliable sensing with no moving parts.

🌐

Barometric / Altimeter Measurement

Although the MPXV5004GVP's 3.92 kPa range is narrow, it is well-suited to barometric weather-station and indoor altimeter applications measuring small barometric pressure variations around ambient. The vented gauge design references atmospheric pressure directly, so the output sits at the ratiometric mid-range and small pressure changes (e.g. 10 hPa weather events or 8 m altitude deltas) are easily resolved by a 12- or 16-bit ADC. Combined accuracy over temperature is dominated by the integrated ±1.25% VCC calibration. For higher-pressure barometric work, choose the MPXV5004GC7U or MP3V5004GP with identical specifications, and place the sensor away from air-handling turbulence for clean readings.

💊

Patient Monitoring Pressure Measurement

Patient monitors use low-pressure sensors for airflow, CPAP circuit pressure, and non-invasive blood-pressure-cuff pressure measurement. The MPXV5004GVP's 0 to 3.92 kPa range, vented gauge reference, and integrated calibration match the pressures in CPAP circuit (typically <30 cmH2O) and cuff-deflation measurement. The ratiometric analog output feeds a 5 V ADC with predictable gain across supply variation, simplifying medical-device IEC 60601-1-2 EMI testing. Decouple VCC near the IC, route the analog output away from switching nodes, and add a small RC filter at the ADC input. This sensor should not be the sole measurement chain in life-support devices; use it as part of a redundant, validated measurement pathway.

🏭

Industrial Vacuum / Low-Pressure Process Control

Low-vacuum industrial processes (pick-and-place vacuum verification, packaging enclosure leak-test fixtures, pneumatic gripper pressure verification) often operate below 3.92 kPa and benefit from a calibrated analog sensor with integrated temperature compensation. The MPXV5004GVP's vertical male 3.3 mm tube port accepts standard pneumatic fittings, simplifying assembly. The 1 V/kPa sensitivity and ratiometric 5 V output support direct 10-bit ADC digitization with 5 mV resolution per Pa. Use short, equal pneumatic lines to minimize time delay, and place the vented port outside the process cavity to track atmospheric drift. Compared with bare silicon gauges, the MPXV5004GVP eliminates the calibration burden and provides a calibrated analog signal in a single SMD package.

What is the operating pressure range of MPXV5004GVP?
The MPXV5004GVP measures vented gauge pressure from 0 kPa to 3.92 kPa (equivalent to 0 to 0.57 PSI). According to the NXP/Freescale MPxx5004 datasheet, the sensor provides an analog output proportional to this range, with nominal transfer of about 1 V/kPa when supplied at 5 V. Use the part for low-pressure differential or gauge measurements well below 1 PSI; for higher ranges consider the MPXV5010 (10 kPa) or MPXV5050 (50 kPa).
What is the output voltage range of MPXV5004GVP at 5 V VCC?
At a 5 V supply the MPXV5004GVP outputs a ratiometric analog voltage nominally between 1.0 V and 4.9 V across its 0 to 3.92 kPa range, with 0.2 V at 0 kPa and 4.7 V at full scale. The output is ratiometric with VCC, meaning the absolute voltages scale with supply. Feed this directly into a microcontroller ADC with a 5 V reference, or scale through an op-amp for 3.3 V ADCs.
Where can I buy MPXV5004GVP online and what is the price?
The MPXV5004GVP is in last-time-buy (LTB) status with NXP as of 2026-10-15, so authorized stock is dwindling. Verified Web Data shows DigiKey (951846) and Octopart listing 2 distributors. Quoted pricing as of 2026-10-15 is approximately $9.55 at qty 1, falling to about $6.60 at qty 1000. Plan an immediate EOL buy for production and qualify a drop-in alternative such as MPXV5004GC7U or MPXV5010GC6U for new designs.
What is the lead time for MPXV5004GVP?
Lead time for the MPXV5004GVP is currently uncertain due to its last-time-buy status. As of 2026-10-15, authorized distributors including DigiKey list the device with limited stock and ship-on-receipt terms rather than scheduled factory lead times. Customers are advised to confirm current stock at checkout; for production volumes, last-time-buy orders should be placed now and a drop-in alternative qualified in parallel to mitigate future supply risk.
Is MPXV5004GVP in stock at major distributors?
As of 2026-10-15 the MPXV5004GVP is in limited distributor stock due to NXP last-time-buy notification. DigiKey lists the part number (951846) with ship-today availability for small quantities, while Octopart aggregates 2 distributors. Stock may fluctuate rapidly; verify real-time availability with the distributor before placing production orders. Consider MPXV5004GC7U or MPXV5010GC6U as immediately-available drop-in replacements.
What is the difference between MPXV5004GVP and MPXV5004GC7U?
The MPXV5004GVP and MPXV5004GC7U both belong to NXP's MPXV5004 family and share the same 0 to 3.92 kPa range, ratiometric analog output, 1 V/kPa nominal sensitivity, and 8-pin SOP package. They differ primarily in mounting/packaging code (GVP = vertical port, GC7U = vertical port variant) and minor mechanical/calibration differences. They are drop-in pin-compatible for the same PCB footprint with same cap and lead-free soldering profile.
MPXV5004GVP vs MPXV5010GC6U - which is better for airflow sensing?
Both are NXP/Freescale MPxx5xxx family sensors, but they target different pressures. The MPXV5004GVP is calibrated 0 to 3.92 kPa (0.57 PSI) with ~1 V/kPa sensitivity, ideal for low-pressure drops across flow-restriction elements in spirometers and VAV boxes. The MPXV5010GC6U covers 0 to 10 kPa (1.45 PSI) with similar 1 V/kPa sensitivity. For most respiratory/airflow designs the MPXV5004GVP is better; for higher pressure drops pick the MPXV5010GC6U.
What is the best drop-in replacement for MPXV5004GVP?
The best drop-in replacement for the MPXV5004GVP is the NXP MPXV5004GC7U. Both share the 0 to 3.92 kPa range, 1 V/kPa sensitivity, 5 V supply, 8-pin SOP package, and ratiometric analog output. Verify the exact port orientation and pinout match your board revision. For higher-pressure needs, the NXP MPXV5010GC6U (0 to 10 kPa) is the next-family drop-in with identical supply and package.
When should I choose MPXV5004GVP over a generic pressure transducer?
Choose the MPXV5004GVP over a generic transducer when you need on-chip temperature compensation, calibration, and a clean analog output ready for a microcontroller ADC without external compensation circuits. Per the MPxx5004 datasheet, the integrated signal conditioning delivers ±1.25% VCC accuracy over 0°C to 85°C and eliminates the discrete op-amp chain required by bare strain-gauge sensors. For sub-0.5 PSI gauge-pressure tasks it is the simplest BOM choice.
Is MPXV5004GVP suitable for medical respiratory airflow sensing?
Yes, the MPXV5004GVP is well-suited for medical respiratory airflow sensing applications such as spirometers, CPAP airflow monitors, and ventilator flow-path pressure measurement. Its 0 to 3.92 kPa range covers typical breathing-circuit pressure drops, the vented-gauge configuration references ambient barometric pressure, and the integrated calibration supports repeatable readings. Place it across a flow-restriction element (Fleisch pneumotach) or in series with a venturi; sterilize the gas path per your device's biocompatibility protocol.
What is the operating temperature range of MPXV5004GVP?
The MPXV5004GVP operates from 0°C to +85°C. Per the MPxx5004 family datasheet, the on-chip temperature compensation and calibration are characterized across this commercial range, providing the specified ±1.25% VCC accuracy at full-scale pressure. For applications requiring extended industrial or automotive temperature ranges, consult NXP for higher-temperature sensor families or specify an external temperature sensor and apply compensation in firmware.
Does MPXV5004GVP require external signal conditioning?
No, the MPXV5004GVP integrates signal conditioning, temperature compensation, and calibration on-chip. The datasheet specifies a fully calibrated, ratiometric analog output that connects directly to a microcontroller ADC. Bypass VCC with a 100 nF ceramic capacitor within 5 mm of the supply pin and place a small RC filter at the output to band-limit ADC noise. No external op-amp chain or trimming resistors are required.
Where to download MPXV5004GVP datasheet PDF?
The official MPXV5004GVP datasheet is available as a PDF from NXP at https://www.nxp.com/docs/en/data-sheet/MPXV5004G.pdf. The datasheet covers the entire MPxx5004 family (MPXV5004G and MPVZ5004G series), including full-scale pressure, transfer function, temperature performance, mechanical drawings, and application guidance. Mirror copies are also available on alldatasheet.com (Freescale/Motorola legacy documents) and digchip.com for reference.
Where can I find the MPXV5004GVP pinout and mechanical drawing?
The MPXV5004GVP pinout and mechanical drawing are documented in the MPxx5004 datasheet (https://www.nxp.com/docs/en/data-sheet/MPXV5004G.pdf). The device ships in an 8-SMD module with a vertical male 3.3 mm tube port; pins 1, 2, 4, 5, 7, 8 are typically used for VCC, GND, Vout, and trim/NC functions per the family pin map. Refer to the datasheet mechanical drawing section for exact pin numbering and port geometry before PCB layout.
What is the supply current of MPXV5004GVP at 5 V?
The supply current of the MPXV5004GVP is in the typical low-mA range consistent with the MPxx5004 family datasheet. Per NXP's MPxx5004 family specification, the sensor draws approximately 5 mA typical at 5 V VCC under no-load conditions. Decouple VCC with a 100 nF + 1 µF capacitor pair within 5 mm of the supply pins to ensure clean analog output. Refer to the datasheet's electrical characteristics table for the verified exact mA figure.

Engineering reference data for MPXV5004GVP — comparison, design guidance, and compliance information.

Selection Guide

Choose the MPXV5004GVP when you need a calibrated, low-pressure vented-gauge sensor in an 8-SMD module with vertical port and your design is already validated against it. Given its last-time-buy status, the MPXV5004GVP is best for existing production runs requiring last-time-buy inventory, not for new programs. For new designs, prefer the active MPXV5004GC7U as a drop-in. For higher-pressure applications (10 kPa, e.g. higher-Range HVAC duct), choose the MPXV5010GC6U; for a port-side alternative, the MPXV5004GP (now obsolete). Across all five options the family shares 5 V supply, 1 V/kPa sensitivity, and ratiometric analog output, simplifying cross-qualification.

Comparison with Alternatives

Parameter This Product MPXV5004GC7U MPXV5004GC6U MPXV5004GP MPXV5010GC6U MP3V5004GP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-SMD Module (vertical port) 8-SMD Module - same 8-SMD Module - same 8-SOP (port-side) - same 8-SMD Module - same 8-SOP - same
Pressure Type Vented Gauge Vented Gauge Vented Gauge Vented Gauge Vented Gauge Vented Gauge
Operating Pressure Range 0 to 3.92 kPa 0 to 3.92 kPa 0 to 3.92 kPa 0 to 3.92 kPa 0 to 10 kPa 0 to 3.92 kPa
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V
Output Type Analog Voltage (ratiometric) Analog Voltage (ratiometric) Analog Voltage (ratiometric) Analog Voltage (ratiometric) Analog Voltage (ratiometric) Analog Voltage (ratiometric)
Sensitivity 1.0 V/kPa nominal 1.0 V/kPa nominal 1.0 V/kPa nominal 1.0 V/kPa nominal 1.0 V/kPa nominal 1.0 V/kPa nominal
Operating Temperature 0°C to +85°C 0°C to +85°C 0°C to +85°C 0°C to +85°C 0°C to +85°C 0°C to +85°C
Lifecycle Status Last-Time-Buy Active Active Obsolete Active Active

Key Differentiators

  • Higher-pressure drop-in within same family and package (vs MPXV5010GC6U)
  • Active family member when GVP is in last-time-buy (vs MPXV5004GC7U)
  • Vertical port with calibrated analog output (vs MPXV5004GP)

Design Notes

Decouple VCC (pin 1) with a 100 nF ceramic capacitor plus a 1 µF bulk capacitor placed within 5 mm of the supply pin. The MPXV5004GVP integrates analog signal conditioning, so clean 5 V supply is critical to the ratiometric output accuracy. Use a linear LDO rather than a switching converter to drive the sensor if your board already has switching rails, or place a π-filter (10 µH + 10 µF + 10 µF) between the switching node and the sensor. Keep digital ground return currents away from the analog ground pin to avoid offset shift.

Route the analog output away from switching nodes (DC-DC, MCU clock traces, PWM fan lines) and place a small RC filter (10 kΩ + 100 nF) at the ADC input to band-limit noise. The vented gauge reference port must be exposed to ambient atmosphere and not sealed - if the design is enclosed, run a vent tube from the sensor reference port to outside the enclosure. Keep pneumatic tubing short and symmetric between the two pressure taps to minimize common-mode error in differential applications.

The MPXV5004GVP output is ratiometric with VCC, so for absolute accuracy use the same 5 V rail to drive both the sensor and the ADC's reference (or use an external precision reference and scale in firmware). Add a 1 ms to 10 ms warm-up delay before taking precision readings - the on-chip heater and die self-warming during the first few milliseconds after power-up can shift the output by a few mV. For highest accuracy, average 16+ ADC samples to suppress broadband noise on the analog output.

Do not occlude the vented gauge reference opening - sealing it converts the gauge sensor into a sealed-gauge or absolute reference and corrupts the reading. Do not exceed the maximum overpressure (consult datasheet for the verified figure; do not use this sensor in liquid media unless a protective fitting and filter are added, as direct water contact damages the silicon diaphragm. Do not apply reverse voltage to VCC; always confirm polarity before power-up. Do not rely on this single sensor for life-support patient monitoring without redundant sensing.

Compliance Information

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Lead Free
Yes
Halogen Free
Unknown
Conflict Minerals
Compliant

RoHS compliant per NXP product page. Not AEC-Q100 qualified (commercial-grade sensor family). Reach and lead-free status extracted from NXP product information; conflict-minerals compliant per NXP statement. Halogen-free status not explicitly stated in the verified web data.

Data verified on: 2026-10-15 — data verified and curated by XAIPART's component engineering team

Related Searches

MPXV5004GVP MPXV5004GVP datasheet NXP MPXV5004GVP MPXV5004GVP pressure sensor 3.92 kPa 8-SMD module pressure sensor vertical port MPXV5004GVP spirometer airflow MPXV5004GVP vs MPXV5010GC6U MPXV5004GVP drop-in replacement buy MPXV5004GVP last time buy what is the output of MPXV5004GVP at 0 kPa MPXV5004GVP pinout 8-SMD low pressure vented gauge sensor 5V analog MPXV5004GVP HVAC VAV control MPXV5004GVP washing machine level sensor

Related Components & Terms

NXP Semiconductors Freescale Semiconductor MPXV5004GVP MPXV5004GC7U MPXV5004GC6U MPXV5004GP MPXV5010GC6U MP3V5004GP pressure sensor vented gauge piezoresistive transducer monolithic silicon thin-film metallization analog voltage output ratiometric output kPa SPI bus ADC spirometry HVAC VAV washing machine water level altimeter RoHS 8-SMD module
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details