PD-9506GC/AC - 6-Port 60W PoE Midspan 802.3bt | Microchip
MPN: PD-9506GC/AC ✓ Active| Qty | Unit Price | Extended |
|---|---|---|
| 1 | $1140.62 | $1,140.62 |
| 10 | $1140.62 | $11,406.20 |
| 100 | $1140.62 | $114,062.00 |
| 500 | $1140.62 | $570,310.00 |
| 1,000 | $1140.62 | $1,140,620.00 |
PD-9506GC/AC Overview
A PoE midspan injector is a network device that inserts DC power onto Ethernet cabling without replacing the existing Ethernet switch. Sitting between the switch and the powered device (PD), it injects power over both data and spare wire pairs (1/2, 3/6, 4/5, 7/8) while passing data traffic transparently. Midspans occupy the power-delivery layer of the network infrastructure hierarchy: PoE midspan -> PoE power sourcing equipment (PSE) -> network power delivery -> power management.
Key features include IEEE 802.3bt (Type 4) compliance for up to 60 W per port, six 10/100/1000 Mbps RJ45 ports, TIA/EIA-568 category 5/5e/6 cabling support, and integrated NMS for monitoring and management. The unit meets CE approval and is designed for indoor deployment in enterprise telecommunications rooms.
Architecturally, the PD-9506GC/AC is part of Microchip's PD-95xxGC multiport family (6, 12, and 24 ports), which supplies power over all four pairs within the cable. Detection and classification circuitry per IEEE 802.3bt ensures safe handshaking with powered devices, including legacy detection support.
Typical applications include powering 802.11ax/802.11ac wireless access points, pan-tilt-zoom (PTZ) and dome surveillance cameras, IP videophones, thin clients, and other high-power Ethernet end terminals that require 60 W.
Design consideration: verify per-port power budgets across all six ports simultaneously, and confirm the AC circuit and cabling category support the full 60 W-per-port bt-mode operation.
This page synthesizes distributor pricing, drop-in alternatives, and practical deployment notes not found in the manufacturer datasheet.
Drop-in alternatives for PD-9506GC/AC — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Variants in this series
Same-series models that are drop-in compatible with PD-9506GC/AC (same form factor and footprint) — differing in PoE Standard, Data Rate, Network Management, Output Voltage, Power per Port.
Quick Comparison Tool — Select alternative parts for side-by-side comparison:
PD-9506GC/AC-US
✅ Drop-In📋 Reference alternative (not in catalog)
PD-9506GC/AC-UK
✅ Drop-In📋 Reference alternative (not in catalog)
PD-9506GC/AC-EU
✅ Drop-In📋 Reference alternative (not in catalog)
PD-9506GC/AC-JP
✅ Drop-In📋 Reference alternative (not in catalog)
PD-9606GC/AC
✅ Drop-In✓ In Stock
Contact for price
View Datasheet →PD-9506GC/AC Specifications (manufacturer-published)
| Ports | 6 x 10/100/1000Base-T |
| PoE Standard | IEEE 802.3bt-compliant |
| Power per Port | up to 60 W |
| Data Rate | 10/100/1000 Mbps |
| PoE Output Voltage | 55 V |
| Input Voltage | 100-240 VAC |
| Cabling | TIA/EIA-568 category 5/5e/6 |
| Power Pairing | All 4 pairs (1/2, 3/6, 4/5, 7/8) |
| Network Management | NMS supported |
| Environment | Indoor (EEPoE) |
| Mounting | Rack-mount |
| Approvals | CE approved |
| Cord Variant (this MPN) | AC cord, region-unspecified |
| Packaging | Bulk |
PD-9506GC/AC Interfaces & Connectors
PD-9506GC/AC exposes the following interfaces and connectors as published by the manufacturer: Power Input. Expansion header pinout, connector pin numbering, and electrical limits are defined in the manufacturer documentation.
| Power Input | IEEE 802.3bt-compliant |
Refer to the manufacturer documentation for the full expansion header pinout and connector pin numbering.
Power & Thermal Characteristics
| Power Input | IEEE 802.3bt-compliant |
Power input and thermal parameters for PD-9506GC/AC as published by the manufacturer.
Typical Applications
PD-9506GC/AC is suitable for 6 applications: Wireless Access Point Deployment, PTZ and Dome Surveillance Camera Powering, IP Videophone and Thin Client Rollouts, Enterprise Network Rack Integration, Telecommunications and Carrier Infrastructure, Wireless Networking Backhaul Upgrades.
Wireless Access Point Deployment
The PD-9506GC/AC is designed specifically to power IEEE 802.11 access points, and its 60 W per port capacity covers the full draw of 802.11ax (Wi-Fi 6/6E) enterprise APs that exceed the 30 W limit of 802.3at. In a typical deployment, each of the six DATA IN ports connects to a non-PoE gigabit switch, and the PoE OUT port feeds the AP over category 5e/6 cabling with power on all four pairs (1/2, 3/6, 4/5, 7/8) at 55 V. The 10/100/1000 Mbps data rate preserves gigabit backhaul to the AP, while IEEE 802.3bt autonegotiation ensures each AP draws only its negotiated class. One midspan thus upgrades six AP locations without replacing the existing switch.
Recommended
PTZ and Dome Surveillance Camera Powering
Pan-tilt-zoom and dome cameras with heaters, blowers, wipers, and IR illuminators routinely draw 40-60 W, beyond 802.3at. The PD-9506GC/AC's 60 W per port at 55 V over IEEE 802.3bt Type 4 operation directly addresses this, and Microchip explicitly lists PTZ and dome cameras as target devices. Each camera connects through the midspan's PoE OUT port over category 5/5e/6 cable, with power on all four pairs. The NMS interface lets security integrators monitor per-port power delivery and detect cable faults remotely. Because the midspan sits indoors in the head-end rack, only standard outdoor-rated cameras and cabling are exposed at the edge, simplifying enclosure requirements.
Recommended
IP Videophone and Thin Client Rollouts
Microchip identifies IP videophones and thin clients as primary target loads for the PD-95xxGC family. These devices typically sit at desk locations served by legacy non-PoE switches; the PD-9506GC/AC inserts 60 W-capable power into the existing structured cabling without switch replacement. At 10/100/1000 Mbps the midspan does not bottleneck gigabit desktop links, and 802.3bt classification ensures videophones drawing only 15-30 W are powered safely at their negotiated class. Deployments benefit from the 100-240 VAC input for global offices, CE approval for EU deployment, and per-port detection that protects non-PoE devices accidentally connected to a PoE port.
Recommended
Enterprise Network Rack Integration
The PD-9506GC/AC features a rack-mount design for straightforward integration into 19-inch telecommunications racks alongside existing Ethernet switches. In brownfield upgrades, the midspan bridges the gap between a non-PoE switch and high-power powered devices: switch ports patch to DATA IN, and horizontal cabling to endpoints lands on PoE OUT. The NMS capability enables centralized monitoring of power status across the six ports, useful for data-center-style telecom rooms managing multiple midspans. With 100-240 VAC input and CE approval, the unit deploys across global facilities. Bulk packaging suits integrator purchasing, and the PD-95xxGC family scales from 6 to 24 ports within one management ecosystem.
Recommended
Telecommunications and Carrier Infrastructure
Distributor documentation (Microchip USA) lists telecommunications as a core application domain for the PD-9506GC/AC-US. Carrier and CPE aggregation sites frequently contain legacy gigabit switches without PoE budget for emerging high-power endpoints such as small-cell radios, ONTs with backup batteries, or 802.11 hotspot equipment. The midspan's 55 V, 60 W per port 802.3bt delivery over all four pairs supports these loads over standard category 5/5e/6 outside-plant-compatible cabling within Ethernet distance limits. CE approval and 100-240 VAC operation ease deployment across regions; regional cord variants (-US, -UK, -EU, -JP) simplify logistics for multi-country carrier rollouts.
Recommended
Wireless Networking Backhaul Upgrades
Beyond access points, wireless networking infrastructure includes point-to-point bridges, sector radios, and small-cell backhaul units, many of which now require 40-60 W. The PD-9506GC/AC provides 802.3bt-compliant power to six such devices simultaneously while passing 10/100/1000 Mbps data transparently, making it a practical add-on for rooftop or tower-head-end racks fed by non-PoE switches. Power over all four pairs at 55 V reduces per-pair current and associated cable heating versus lower-voltage injection, supporting reliable long-run delivery. The NMS interface aids in remote fault isolation for hard-to-access radio sites, and the six-port granularity matches typical small-cluster radio deployments.
Recommended
Recommended Products Summary
Engineering reference data for PD-9506GC/AC — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | PD-9506GC/AC-US | PD-9506GC/AC-UK | PD-9506GC/AC-EU | PD-9606GC/AC |
|---|---|---|---|---|---|
| Package | 6-port indoor rack-mount midspan enclosure | 6-port indoor rack-mount midspan enclosure - same | 6-port indoor rack-mount midspan enclosure - same | 6-port indoor rack-mount midspan enclosure - same | 6-port indoor rack-mount midspan enclosure - same family |
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Ports | 6 x 10/100/1000Base-T | 6 x 10/100/1000Base-T | 6 x 10/100/1000Base-T | 6 x 10/100/1000Base-T | 6 x 10/100/1000Base-T |
| Power per Port | up to 60 W (802.3bt) | up to 60 W | up to 60 W | up to 60 W | up to 90 W |
| PoE Standard | IEEE 802.3bt-compliant | IEEE 802.3bt-compliant | IEEE 802.3bt-compliant | IEEE 802.3bt-compliant | IEEE 802.3bt-compliant |
| NMS Management | Yes | Yes | Yes | Yes | Yes (PD-96xxGC family NMS) |
| Lifecycle Recommendation | Active (successor suggested for new designs) | Active | Active | Active | Active - Microchip recommended for new designs |
Key Differentiators
- IEEE 802.3bt Type 4, 60 W per port on all four pairs (vs PD-9506GC (non-bt legacy midspans))
- Integrated NMS network management (vs Basic unmanaged 6-port midspans)
- Cost-optimized 6-port granularity (vs PD-9606GC/AC)
Design Notes
Budget the AC feed for worst-case load: six ports at 60 W equals 360 W of PoE delivery before accounting for conversion efficiency losses (estimated: at roughly 85-90% efficiency, mains draw approaches 400-425 W). Verify the rack PDU circuit and branch circuit capacity support this continuous load with headroom per local electrical code. The 100-240 VAC universal input simplifies global deployment, but cord regional variants (-US, -UK, -EU, -JP) must match the destination outlet standard.
The PD-9506GC/AC is rated for indoor (EEPoE) environments only. Installing it in outdoor cabinets without environmental control violates the product's environmental rating and risks condensation-related failure. Verify that all cabling between the midspan and outdoor powered devices remains category 5/5e/6 within Ethernet distance limits (100 m). Also confirm each powered device supports IEEE 802.3bt classification - legacy af/at devices will negotiate lower power automatically, but non-standard PDs may fail detection.
When racking the unit, maintain at least one rack unit of ventilation clearance above and below the midspan; a 400 W-class power supply in a 1U/2U enclosure needs convective airflow. Route DATA IN and PoE OUT patch cords with strain relief and avoid running them parallel to AC power cords to minimize coupled noise on the gigabit links. Use the NMS interface during commissioning to confirm per-port detection and class negotiation for every connected powered device before handover.
Compliance Information
Verified web data confirms CE approval for the PD-9506GC family (per Microchip USA). RoHS/REACH declarations must be confirmed on the Microchip product page or via distributor certificate of conformance.