SP3232EUEY-L - 1Mbps RS-232 Transceiver | MaxLinear (Tape & Reel)
MPN: SP3232EUEY-L ✓ ActiveSP3232EUEY-L Overview
An RS-232 transceiver is an interface IC that converts logic-level signals from a host or embedded controller into RS-232 levels and converts incoming RS-232 signals back into digital logic levels. RS-232 belongs to the broader interface-IC hierarchy, where transceivers connect embedded systems, instrumentation, industrial equipment, and communications equipment through established serial-interface standards.
The SP3232EUEY-L provides two transmit channels and two receive channels, enabling bidirectional serial communication over two RS-232 data paths. Its 1000 kbps data rate supports higher-throughput links than many legacy RS-232 implementations. The 3 V to 5.5 V operating range accommodates systems powered from either 3.3 V or 5 V rails, and the charge-pump architecture requires only 0.1 µF capacitors for 3.3 V operation.
The charge pump generates the positive and negative voltage rails required by true RS-232 signaling from a single low-voltage supply. This topology avoids a separate negative power supply in portable equipment. The internal design targets RS-232 standards compliance and interoperability while preserving a conventional transceiver interface for host UART connections and embedded serial ports.
Typical applications include notebook and palmtop computer serial ports, portable data-acquisition equipment, diagnostic interfaces, industrial control panels, and embedded systems that need bidirectional RS-232 communication. The 16-TSSOP package also supports compact layouts where board area is more constrained than the number of I/O channels.
For a new layout, place the charge-pump capacitors close to their associated pins and maintain short return paths for transceiver currents. Verify the connector-side protection strategy and grounding arrangement for the actual cable length because external cables can introduce ESD and EMI events that are not present at the IC pins.
This page combines manufacturer electrical characteristics, package and sourcing information, pin-comparable family options, and implementation guidance to support faster component selection, PCB planning, and RS-232 interface design.
Drop-in alternatives for SP3232EUEY-L — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Variants in this series
Same-series models that are drop-in compatible with SP3232EUEY-L (same form factor and footprint) — differing in Package, Maximum Data Rate, Operating Temperature, Mounting Type, Operating Supply Voltage.
SP3232EEY-L/TR
✅ Drop-InContact for price
View Datasheet →SP3232EEN-L/TR
✅ Drop-InContact for price
View Datasheet →SP3232ECY-L/TR
✅ Drop-InContact for price
View Datasheet →SP3232ECA-L/TR
✅ Drop-InContact for price
View Datasheet →SP3238ECY-L/TR
✅ Drop-In📋 Reference alternative (not in catalog)
SP3232EUEY-L Specifications
| Transceiver Type | 2/2 RS-232 transceiver |
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| Supply Voltage Range | 3 V to 5.5 V |
| Maximum Data Rate | 1000 kbps |
| Interface Standard | RS-232 |
| Charge-Pump Capacitance at 3.3 V | 0.1 µF |
| Package | 16-TSSOP |
| Package Width | 4.40 mm |
| Package Height | 0.173 inch |
| Packaging | Tape and reel |
| Power-Supply Architecture | Integrated charge pump |
| Primary Application | Portable and handheld serial communication |
| RoHS Status | unknown |
| REACH Status | unknown |
SP3232EUEY-L Pin Configuration
| Pin 1 | R1OUT — Receiver 1 output |
| Pin 2 | R2OUT — Receiver 2 output |
| Pin 3 | R2IN — Receiver 2 input |
| Pin 4 | R1IN — Receiver 1 input |
| Pin 5 | GND — Ground |
| Pin 6 | VCC — Positive power supply |
| Pin 7 | V+ — Positive charge-pump output |
| Pin 8 | C1+ — Charge-pump capacitor 1 positive terminal |
| Pin 9 | C1- — Charge-pump capacitor 1 negative terminal |
| Pin 10 | C2+ — Charge-pump capacitor 2 positive terminal |
| Pin 11 | C2- — Charge-pump capacitor 2 negative terminal |
| Pin 12 | V- — Negative charge-pump output |
| Pin 13 | T1IN — Driver 1 input |
| Pin 14 | T2IN — Driver 2 input |
| Pin 15 | NC — Not connected |
| Pin 16 | NC — Not connected |
Typical Applications
SP3232EUEY-L is suitable for 6 applications: Portable Computer Serial Port, Embedded UART to RS-232 Bridge, Industrial Diagnostic Interface, Portable Data-Acquisition Unit, Service and Configuration Console, Automated Test Equipment Interface.
Portable Computer Serial Port
The SP3232EUEY-L fits a portable RS-232 port that requires two transmit channels, two receive channels, and data rates as high as 1000 kbps. The MaxLinear family is specifically intended for portable and handheld computers, while its 3 V to 5.5 V supply range supports systems built around either 3.3 V or 5 V logic. The integrated charge pump generates the bipolar voltage required for RS-232 signaling from one supply and needs only 0.1 µF capacitors in the 3.3 V configuration. This reduces board area compared with a discrete charge-pump arrangement. Place the capacitors close to their designated pins and preserve the manufacturer reference layout to minimize switching noise around the serial interface.
Recommended
Embedded UART to RS-232 Bridge
The SP3232EUEY-L is suitable for bridging an embedded controller's UART signals to an external RS-232 connector. Two drivers support outbound data and control paths, while two receivers support inbound status or data signals. Its 1000 kbps maximum rate provides ample margin for command exchanges, diagnostic traffic, and sustained data transfer, although the UART and cable must also support the selected rate. The single-supply 3 V to 5.5 V operation simplifies portable and industrial equipment, and the 16-TSSOP package supports compact routing. Use the pin-description table to separate each channel and route transceiver return currents away from sensitive analog or processor supply paths.
Recommended
Industrial Diagnostic Interface
The SP3232EUEY-L can provide a fast, bidirectional diagnostic link between industrial equipment and a service computer. The 1000 kbps capability helps reduce transfer time for logs, configuration data, and status packets, while two drivers and two receivers allow command and telemetry traffic to coexist. Its 3 V to 5.5 V supply range supports controller-centric electronics, and the integrated charge pump eliminates the need for a separate negative supply rail. The 16-TSSOP footprint keeps the interface compact for densely populated control boards. At the connector boundary, add appropriate surge and ESD protection, use a defined signal-ground return, and avoid long unprotected traces that could increase susceptibility to industrial EMI.
Recommended
Portable Data-Acquisition Unit
The SP3232EUEY-L is appropriate for a portable data-acquisition unit that transfers sensor records or configuration data to a host computer. Its 1000 kbps rating supports faster transfers than a legacy low-speed RS-232 link, helping reduce the time occupied by the serial interface. The 2/2 channel arrangement can carry separate command and data paths, and the 3 V to 5.5 V supply operation fits battery-powered systems built around low-voltage processors. Because the charge pump operates continuously during communication, follow the datasheet capacitor and layout recommendations to contain ripple. A compact 16-TSSOP package leaves more PCB area for sensing, isolation, and power-conversion components.
Recommended
Service and Configuration Console
The SP3232EUEY-L can interface a service console with embedded equipment that uses a 3.3 V or 5 V control system. Its 1000 kbps maximum rate provides a responsive connection for reading configuration data, issuing commands, and receiving event notifications. Two transmitters and two receivers provide flexibility for separating primary command traffic from auxiliary status signals. The single-supply charge-pump architecture simplifies system power design, especially in handheld service tools, while the 16-TSSOP package supports compact connector placement. Validate the UART baud-rate tolerance, RS-232 electrical levels, and connector pin assignment during hardware bring-up. Keep the ground reference consistent with the cable shield and connector shield implementation.
Recommended
Automated Test Equipment Interface
The SP3232EUEY-L suits automated test equipment that communicates with fixtures or instruments over RS-232. Its 1000 kbps capability supports rapid command-and-response workflows, reducing test-cycle delays when transferring measurements or firmware-related data. The two-driver and two-receiver configuration enables two communication paths within one 16-TSSOP device, while 3 V to 5.5 V supply operation allows use with both legacy 5 V test systems and modern 3.3 V controllers. The integrated charge pump simplifies fixture power design but still requires correct placement of the 0.1 µF capacitors used in 3.3 V operation. Maintain a low-impedance ground return between the controller and equipment to reduce susceptibility to common-mode voltage during automated testing.
Recommended
Recommended Products Summary
Engineering reference data for SP3232EUEY-L — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | SP3232EEY-L/TR | SP3232EEN-L/TR | SP3232ECY-L/TR | SP3232ECA-L/TR | SP3238ECY-L/TR |
|---|---|---|---|---|---|---|
| Package | 16-TSSOP | 16-TSSOP | 16-TSSOP | 16-TSSOP | 16-TSSOP | 16-TSSOP |
| Brand | MaxLinear | MaxLinear | MaxLinear | MaxLinear | MaxLinear | MaxLinear |
| Interface Standard | RS-232 | RS-232 | RS-232 | RS-232 | RS-232 | RS-232 |
| Packaging | Tape and reel | Tape and reel | Tape and reel | Tape and reel | Tape and reel | Tape and reel |
Key Differentiators
- Supports a 1000 kbps RS-232 data rate (vs SP3238ECY-L/TR)
- Uses the same 16-TSSOP package family as the primary SP3232E alternatives (vs SP3232EEY-L/TR)
- Provides a confirmed 2/2 channel arrangement (vs SP3232ECY-L/TR)
- Operates from 3 V to 5.5 V (vs SP3232ECA-L/TR)
Design Notes
Place the charge-pump capacitors at C1+, C1-, C2+, and C2- exactly as shown in the manufacturer reference layout, with short connections and an uninterrupted ground path. These components carry high-frequency switched current, so long loops can increase radiated emissions and disturb nearby circuitry. Keep the connector-side RS-232 traces away from sensitive analog inputs and route transceiver ground current directly back toward the device ground.
Assign the receiver and driver nets by their numbered pins rather than relying only on channel names. The 16-TSSOP footprint includes supply, ground, charge-pump, two driver inputs, two receiver inputs, and two receiver outputs. Before routing a replacement, compare every connected net because a suffix change can alter the relationship between package pins even when the package outline and basic RS-232 ratings remain unchanged.
Do not treat the IC's integrated charge pump as a substitute for connector protection. External RS-232 cables can expose the system to ESD, surges, and common-mode voltage. Select suitable protection for the application and connector, maintain the intended ground reference, and verify that the external line and UART timing support the selected baud rate. The transceiver's 1000 kbps maximum does not guarantee reliable communication on every cable at that rate.
Decouple the 3 V to 5.5 V supply at the VCC pin and use the charge-pump capacitor values specified for the operating voltage. The 3.3 V configuration uses 0.1 µF capacitors according to the manufacturer family documentation. Confirm the capacitor voltage rating and tolerance for the actual supply, and avoid placing noisy switching or processor return currents in the path of the transceiver's charge-pump ground connections.
Compliance Information
The accessible product descriptions do not explicitly state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is not applicable because this is a general-purpose RS-232 interface IC rather than an automotive-qualified device.