BSP742RXUMA1 vs BTS4142NHUMA1 Comparação
Comparação detalhada lado a lado de BSP742RXUMA1 por Infineon e BTS4142NHUMA1 por Infineon. Compare especificações principais, parâmetros elétricos, encapsulamento, status do ciclo de vida, preços e disponibilidade para determinar o melhor componente para os requisitos do seu projeto.
Comparação de especificações
| Parâmetro | BSP742RXUMA1 | BTS4142NHUMA1 |
|---|---|---|
| Marca | Infineon | Infineon |
| Categoria | Power MOSFET Drivers | Power MOSFET Drivers |
| Status do ciclo de vida | Ativo | Ativo |
| Status do estoque | In Stock | In Stock |
| Preço unitário (USD) | $0,81 | $0,97 |
| Product Type | Smart High-Side Power Switch | Smart High-Side Power Switch (Classic PROFET 24V) |
| Topologia | 1:1 N-Channel High-Side Switch | — |
| Operating Voltage Range (Vbb) | 5 V to 34 V | — |
| Continuous Load Current | 400 mA | — |
| On-Resistance R_DS(on) (typ) | 70 mΩ | — |
| On-Resistance R_DS(on) (max) | [DATA_NEEDED: R_DS(on) max value at 25C] | — |
| Quiescent Current (Iq typ) | 5 µA | — |
| Input Type | CMOS-compatible logic, active-high | — |
| Faixa de temperatura de operação | -40°C to +150°C (TJ) | — |
| Encapsulamento | PG-DSO-8-6 (8-pin SOIC, exposed pad variant) | PG-SOT223-4 |
| Tipo de montagem | Surface Mount | Surface Mount |
| AEC-Q100 Qualification | Qualified (Automotive Grade) | — |
| Protection Features | Overload, Short-Circuit, Thermal Shutdown with Restart, Overvoltage (Load Dump), Reverse Battery | — |
| Diagnostic Output | Yes (Status / Fault feedback) | — |
| Inductive Load Switching | Fast demagnetization integrated | — |
| RoHS Compliance | Compliant | — |
| MSL Moisture Sensitivity Level | MSL 2 (per JEDEC J-STD-020) | — |
| Number of Channels | — | 1 |
| Switch Topology | — | High-side, N-channel vertical MOSFET |
| Nominal Output Current | — | 1.4 A |
| On-State Resistance (RDS(on)) | — | 70 mOhm (typical) |
| Tensão de alimentação de operação | — | 6 V to 42 V |
| Load-Dump Protection | — | Yes (integrated overvoltage clamp) |
| Overload Protection | — | Yes (current limiting) |
| Thermal Protection | — | Yes (shutdown with auto-restart) |
| Undervoltage Shutdown | — | Yes (auto-restart with hysteresis) |
| ESD Protection (Input Pin) | — | Yes |
| Diagnostic Feedback | — | Yes (open-load, fault) |
| Temperatura de operação | — | -40C to +150C (junction) |
| Status RoHS | — | Compliant |