Parâmetro MAX232ESE+T MAX232CSE+T
Marca Analog Devices Analog Devices
Categoria Interface ICs Interface ICs
Status do ciclo de vida Ativo Ativo
Product Type RS-232 transceiver interface IC —
Driver and Receiver Configuration 2 drivers and 2 receivers —
Tensão de alimentação 4.5 V to 5.5 V —
Maximum Data Rate 120 kbps —
Interface Standard EIA/TIA-232E and CCITT V.28 —
Supported Voltage Interface V.28 and V.24 —
Negative Rail Generation On-chip capacitive voltage generator —
Número de pinos 16 pins —
Encapsulamento 16-pin SOIC 16-pin Narrow SOIC (SOIC-N-16)
Tipo de montagem Surface mount Surface Mount
Temperatura de operação [DATA_NEEDED: operating temperature range] —
Driver Output Levels [DATA_NEEDED: RS-232 output voltage levels] —
Receiver Input Resistance [DATA_NEEDED: receiver input resistance] —
Charge-Pump Capacitors [DATA_NEEDED: required external capacitor values] —
Lead-Free Status Lead-free ordering suffix —
RoHS Compliance unknown —
REACH Compliance unknown —
AEC-Q100 Qualification not_applicable —
Função — RS-232 Line Driver/Receiver (Transceiver)
Number of Drivers — 2
Number of Receivers — 2
Protocol — RS-232 (EIA/TIA-232E, V.28/V.24)
Supply Voltage (Vcc) — 4.5 V to 5.5 V (single +5V supply)
Taxa de dados — 120 kb/s
RS-232 Driver Output Voltage — ±7.5 V minimum (typical ±9 V) into 3 kΩ load
Receiver Input Voltage Range — ±30 V
Charge Pump — Internal; requires 4 × 1 µF external capacitors
Faixa de temperatura de operação — 0 °C to +70 °C (commercial C-grade)
Nível MSL — 1 (unlimited floor life at <30 °C / 85 % RH)
Lead-Free / RoHS — Yes (compliant per +T suffix)
Receiver Input Hysteresis — [DATA_NEEDED: receiver hysteresis voltage]
Supply Current (No Load) — [DATA_NEEDED: typical Icc]
Packaging — Tape & Reel (T+R)