TCAN1051DRBRQ1 vs TCAN4550RGYRQ1 Comparação

Comparação detalhada lado a lado de TCAN1051DRBRQ1 por Texas Instruments e TCAN4550RGYRQ1 por Texas Instruments. Compare especificações principais, parâmetros elétricos, encapsulamento, status do ciclo de vida, preços e disponibilidade para determinar o melhor componente para os requisitos do seu projeto.

Texas Instruments
TCAN1051DRBRQ1 TCAN1051DRBRQ1 - Automotive CAN FD Transceiver | TI

TCAN1051DRBRQ1 - Automotive CAN FD Transceiver | TI

TCAN1051DRBRQ1 ✓ Ativo
Texas Instruments
TCAN4550RGYRQ1 TCAN4550RGYRQ1 - CAN FD SBC with Transceiver 8Mbps VQFN-20 | TI

TCAN4550RGYRQ1 - CAN FD SBC with Transceiver 8Mbps VQFN-20 | TI

TCAN4550RGYRQ1 ✓ Ativo

Comparação de especificações

Parâmetro TCAN1051DRBRQ1 TCAN4550RGYRQ1
Marca Texas Instruments Texas Instruments
Categoria Interface ICs Voltage Regulators
Status do ciclo de vida Ativo Ativo
Status do estoque In Stock In Stock
Preço unitário (USD) $1,18 $3,10
Função CAN transceiver, half duplex —
Protocol CAN / CAN FD (flexible data-rate) —
Taxa de dados 2 Mbps —
Tensão de alimentação 5 V —
Faixa de temperatura de operação -55C to +125C —
Encapsulamento VSON (DRB), 8 pins, 3x3 mm 20-pin VQFN (RGY) 3.5 x 4.5 mm with exposed pad
Tipo de montagem Surface Mount Surface Mount
Number of Drivers/Receivers 1 / 1 —
Automotive Qualification AEC-Q100 (Q1) AEC-Q100 Grade 1
Fault Protection Automotive fault-protected CAN bus pins —
Sleep Mode Yes —
Duplex Half —
Package Height 1.00 mm —
Package Code HVSON —
Receiver Type Half —
Product Type — Automotive System Basis Chip (SBC) with CAN FD Controller and Transceiver
Data Protocol — CAN FD (ISO 11898-1:2015) / CAN 2.0B
Physical Layer Compliance — ISO 11898-2:2016 high-speed CAN
Maximum Data Rate — 8 Mbps
Supply Voltage (VBAT/VCC) — [DATA_NEEDED: VBAT range]
Logic Supply (VIO) — 1.8V / 3.3V / 5V selectable
Host Interface — SPI up to 10 MHz, mode 0/1
Integrated LDO — Yes (5V or 3.3V selectable output)
Low-Power Modes — Standby and Sleep
Watchdog Timer — Yes (SPI-driven window watchdog)
Temperatura de operação — -40C to +125C
Nível MSL — [DATA_NEEDED: MSL rating]
Status RoHS — Compliant
Number of Channels — 1 CAN FD channel
Common-Mode Range — -12V to +12V (CAN bus)

Fichas técnicas e recursos

Ver todos os produtos Criar BOM Solicitar cotação