1408-EM3A-ENT - Ethernet Energy Monitor | Allen-Bradley
N.º da peça: 1408-EM3A-ENT ✓ Ativo| Qtd. | Preço unitário | Total |
|---|---|---|
| 1 | $0 | $0,00 |
| 10 | $0 | $0,00 |
| 100 | $0 | $0,00 |
| 500 | $0 | $0,00 |
| 1.000 | $0 | $0,00 |
1408-EM3A-ENT Visão geral
An energy monitor is an electrical measurement device that records voltage, current, real power, reactive power, apparent power, power factor, and energy consumption. In the industrial automation hierarchy, this product belongs to the power-monitoring and metering class, rather than a semiconductor or passive electronic component. It provides plant-floor information to programmable controllers, energy-management software, and networked control systems.
The 1408-EM3A-ENT is useful where an installation requires both local electrical measurement and network communication. Ethernet connectivity allows the monitor to participate in EtherNet/IP or Modbus TCP systems, while RS-485 supports DF1 and Modbus RTU integrations. The reported 5 A rating identifies the monitored current class, while the 120/240V AC supply specification defines its operating power input.
Typical deployments include industrial control panels, distribution centers, and motor control centers. The monitor can support real-time energy reporting, demand management, and electrical diagnostics without treating the unit as a general-purpose power-quality analyzer. Its communication capabilities make it suitable for systems that need measured parameters sent to programmable controllers or custom software applications.
Installation planning should confirm the voltage rating, current-transformer configuration, communication protocol, network topology, and controller compatibility before energizing the monitor. Because the product is a panel-mounted industrial instrument, wiring, terminal access, grounding, and configuration procedures should follow the applicable Rockwell Automation instructions. Published pricing, exact accuracy details, dimensions, environmental ratings, and full electrical limits were not supplied in the retrieved data and are therefore marked for verification.
This page combines the verified manufacturer and distributor product information, communication capabilities, application context, and selection trade-offs. It distinguishes documented Ethernet and serial functionality from unsupported assumptions and avoids presenting missing electrical or mechanical specifications as confirmed values.
Alternativas drop-in para 1408-EM3A-ENT — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:
1408-EM3A-ENT
✅ Drop-In✓ Em estoque
Consulte o preço
Ver ficha técnica →1408-EM3A
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
1408-EM3A-ENT
✅ Drop-In✓ Em estoque
Consulte o preço
Ver ficha técnica →1408-EM3A-ENT Especificações
| Product Type | PowerMonitor 1000 energy monitor |
| Model | 1408-EM3A-ENT |
| Functionality | EM3 energy, demand, and power monitoring |
| Power Supply | 120/240V AC |
| Ammeterage Rating | 5 A |
| Serial Communication | RS-485 |
| Ethernet Communication | 10Base-T Ethernet |
| DF1 Communication | DF1 full-duplex and half-duplex |
| Modbus RTU | Supported |
| EtherNet/IP | Supported |
| Modbus TCP | Supported |
| Measured Energy Parameters | kW, kVAR, kVA, power factor, and kWh |
| Demand Monitoring | Projected, actual, and power-factor demand |
| Application Environment | Industrial control panels, distribution centers, and motor control centers |
| Country of Origin | MX |
Guia de Configuração de Pinos do 1408-EM3A-ENT standard
Configuração de pinos para 1408-EM3A-ENT (pacote standard). A numeração dos pinos, funções e diagramas de conexão estão definidos no datasheet do fabricante. Consulte-o para o footprint exato e diretrizes de soldagem.
Nenhum dado detalhado de pinagem disponível para 1408-EM3A-ENT.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
1408-EM3A-ENT é adequado para 6 aplicaçãos: Industrial Control Panel Energy Monitoring, Distribution Center Load Profiling, Motor Control Center Monitoring, EtherNet/IP Energy Management Network, Modbus RTU Energy Data Collection, Demand and Cost Allocation System.
Industrial Control Panel Energy Monitoring
The 1408-EM3A-ENT fits industrial control panels that need continuous electrical information alongside machine-control equipment. Its EM3 functionality monitors energy-management attributes and adds projected demand, actual demand, and power-factor demand. Install it where the control system can consume kW, kVAR, kVA, power factor, and kWh data through EtherNet/IP, Modbus TCP, DF1, or Modbus RTU. Compared with a local display-only meter, the documented Ethernet and RS-485 interfaces allow measured parameters to be used by programmable controllers or energy-management software.
Recomendado
Distribution Center Load Profiling
The 1408-EM3A-ENT is appropriate for distribution-center load profiling where operators need to understand where electrical energy is being used. Its documented EM3 energy and demand functions provide the kind of information required for cost allocation and energy control. The 120/240V AC supply and 5 A ammeterage rating support the identified product class, while EtherNet/IP and Modbus TCP enable networked reporting. Installers should confirm current-transformer and measurement-range details in the full manufacturer documentation before assigning revenue or billing functions.
Recomendado
Motor Control Center Monitoring
The 1408-EM3A-ENT can support motor-control-center monitoring when real-time electrical and energy information is needed for diagnostics or energy reporting. The EM3 model monitors energy attributes and demand-related measurements, while the communication options allow a programmable controller or custom software application to receive the data. This is useful when operators want a common measurement platform across multiple motor-related loads. The supplied data does not specify motor-load limits, harmonic analysis, or specialized motor-protection functions, so it should not be treated as a protection relay.
Recomendado
EtherNet/IP Energy Management Network
The 1408-EM3A-ENT is suited to EtherNet/IP-based energy-management networks because Rockwell Automation explicitly identifies EtherNet/IP support and a 10Base-T Ethernet port. A controller or industrial software application can use the network connection to monitor electrical parameters without relying only on a local display. The same unit also supports Modbus TCP, which provides flexibility when the plant network is organized around Modbus rather than EtherNet/IP. Exact network settings and data objects must be configured using the manufacturer’s documentation.
Recomendado
Modbus RTU Energy Data Collection
The 1408-EM3A-ENT supports Modbus RTU over RS-485, making it useful for installations that collect energy and demand information through a serial industrial network. Reported parameters include kW, kVAR, kVA, power factor, and kWh, with EM3 demand functions adding projected and actual demand information. This allows existing RS-485 infrastructure to incorporate networked energy monitoring instead of relying exclusively on manual readings. Baud rate, addressing, termination, and register details were not included in the supplied snippets and must be verified before commissioning.
Recomendado
Demand and Cost Allocation System
The 1408-EM3A-ENT can serve as a measurement source in a demand and cost-allocation system because its EM3 functionality adds projected demand, actual demand, and power-factor demand monitoring. Reported energy parameters can be communicated to applications for load analysis and energy control. It is best suited to industrial metering installations where the design already uses EtherNet/IP, Modbus TCP, DF1, or Modbus RTU. The supplied sources do not establish regulatory billing accuracy, interval data, or demand-response outputs, so those functions should be validated separately.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para 1408-EM3A-ENT — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | 1408-EM3A-ENT | 1408-EM3A | 1408-EM3A-ENT |
|---|---|---|---|---|
| Brand | Allen-Bradley | Allen-Bradley | Allen-Bradley | Allen-Bradley |
Principais diferenciais
- Combines Ethernet and serial industrial communications (vs 1408-EM3A)
- EM3 demand-monitoring functionality (vs Generic standalone power meter)
- Networked energy and power-parameter reporting (vs Local-display-only energy meter)
Notas de projeto
Confirm the panel supply is 120/240V AC before connection and verify the monitor’s complete input-current, frequency, and power-consumption requirements in the manufacturer documentation. The 5 A figure supplied by distributor data describes ammeterage rating, not necessarily the monitor’s power-supply consumption, so it must not be used for conductor sizing. Apply the manufacturer’s overcurrent and disconnect requirements and avoid adding assumptions about terminal numbering.
Choose the communication path during design rather than after installation. Use EtherNet/IP or Modbus TCP over the 10Base-T Ethernet port when the plant network supports those protocols, and use RS-485 with DF1 or Modbus RTU when the existing architecture is serial. Confirm baud rate, addressing, cable type, termination, and register or data-object mappings in the PowerMonitor 1000 communication documentation before commissioning.
Treat the product as an industrial panel instrument rather than a semiconductor PCB component. Follow the manufacturer’s panel-mounting and terminal-wiring instructions, provide the required clearances, and verify that the enclosure and terminal block are rated for the installation environment. Because the supplied data does not include dimensions, terminal assignments, or environmental limits, those items should be taken from the official installation documentation rather than inferred from the product family name.
Do not substitute a generic Ethernet energy meter solely because it has an Ethernet port. The 1408-EM3A-ENT is specified with 120/240V AC power, 5 A ammeterage, RS-485, EtherNet/IP, Modbus TCP, DF1, and Modbus RTU, plus EM3 demand functions. A replacement must be checked for matching voltage, current inputs, protocol data maps, terminal arrangement, and controller compatibility before it can be considered a drop-in replacement.
Informações de conformidade
The RS product result references a RoHS certificate of compliance. The supplied data does not establish REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status.