ams-OSRAM

AS7030B - PPG/ECG Biosensor Module I2C | ams OSRAM | Wearables

N.º da peça: AS7030B ✓ Ativo
Em estoque Enviado em 1 a 3 dias úteis
AS7030B-COLM (module) Package
A partir de $4.65 USD / unidade
MOQ: 1 |
Preço atualizado: 2026-10-11
Preços por volume
Qtd. Preço unitário Total
1 $6.9 $6,90
10 $6.25 $62,50
100 $5.6 $560,00
500 $5.1 $2.550,00
1.000 $4.65 $4.650,00
ℹ️ Todos os preços estão em USD

AS7030B Visão geral

The ams OSRAM AS7030B is a vital-sign biosensor module that combines a photoplethysmography (PPG) optical measurement engine with an embedded electrocardiography (ECG) analog front end, outputting processed data over an I2C interface in a compact surface-mount module package (suffix COLM/COQM).

A biometric sensor module is a device that converts physiological signals, such as blood-volume pulse and cardiac bioelectric potentials, into digital data for health-monitoring systems. Within the sensor hierarchy, the AS7030B sits under optical and biometric sensors, spanning PPG sensors, ECG analog front ends, GSR measurement, and skin-temperature sensing in a single integrated solution for wearable electronics.

Key features include a low-noise analog front end for ECG signal acquisition, a fully integrated optical solution with synchronized LED drive and photodiode readout, a synchronous demodulator for ambient-light rejection, and an infrared emitter with dedicated photodiode enabling a proximity function. The device also supports GSR (galvanic skin resistivity) measurement and external NTC temperature sensor connection, giving designers four biometric modalities from one footprint.

Architecturally, the AS7030B integrates LED drivers, a low-noise transimpedance chain, a synchronous demodulator, and digital control logic on one die, reducing external component count and BOM cost. Time-multiplexed optical measurement with demodulation suppresses DC ambient interference, which is essential for wrist-worn PPG accuracy during motion and daylight exposure.

Typical applications include fitness bands, smart watches, sports watches, and smart patches, where its low-power design supports multi-day intervals between battery recharges. It is also suited to clinical-grade HRV recording and cuffless vital-sign prototyping via the AS7030B_EVALKIT_USB and AS7030B_EVALKIT_BT evaluation kits.

Design considerations: the ams OSRAM recommended supply scheme uses a clean LDO-fed rail (for example a 4.75V LDO as in the official evaluation kit design); noise on VDD directly degrades ECG and PPG signal quality, so careful power filtering is required.

This page synthesizes distributor availability data, the official ams OSRAM datasheet, evaluation-kit documentation, and practical design notes not found in the datasheet alone.

Alternativas drop-in para AS7030B — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Variantes desta série

Modelos da mesma série compatíveis como drop-in com AS7030B (mesmo formato e footprint).

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

AS7030B-COLM

✅ Drop-In
ams-OSRAM
📦 Module (COLM suffix ordering code)
Optical biosensor module with embedded ECG channel (PPG + ECG) · Photoplethysmography (PPG) and electrocardiogram (ECG) · LEDs, photodetectors, analog front-end (AFE), sequencer · I2C · 0x30 (7-bit); 0x60 write / 0x61 read (8-bit) · Yes (INT pin) · Meets IEC 60601-2-47 requirements (per manufacturer) · -30C to +70C

✓ Em estoque

$1.95 / unidade

Ver ficha técnica →

AS7030B Classificações máximas e características elétricas

Product Type Vital-sign biosensor module (PPG + ECG)
Measurement Functions PPG (HRM/HRV/SpO2), ECG, GSR, skin temperature (via external NTC)
Communication Interface I2C
Optical Elements Integrated LEDs and photodiodes (multi-wavelength PPG) plus IR emitter with dedicated photodiode for proximity
Analog Front End Low-noise ECG AFE with synchronous demodulator
Proximity Function Yes (IR emitter + dedicated photodiode)
Ambient Light Rejection Synchronous demodulation
Package / Ordering Code AS7030B-COLM (module)
Tipo de montagem Surface Mount
Typical Applications Fitness bands, smart watches, sports watches, smart patches
Evaluation Kits AS7030B_EVALKIT_USB, AS7030B_EVALKIT_BT

Guia de Configuração de Pinos do AS7030B as7030b-colm (module)

Configuração de pinos para AS7030B (pacote as7030b-colm (module)). A numeração dos pinos, funções e diagramas de conexão estão definidos no datasheet do fabricante. Consulte-o para o footprint exato e diretrizes de soldagem.

Diagrama de pinagem do pacote as7030b-colm (module) para AS7030B

Nenhum dado detalhado de pinagem disponível para AS7030B.

Consulte a ficha técnica para a configuração completa dos pinos.

Aplicações típicas

AS7030B é adequado para 6 aplicaçãos: Smartwatch Heart-Rate Monitoring, Fitness Band Activity Tracking, Clinical-Grade ECG Wearables and Smart Patches, SpO2 Pulse-Oximeter Integration, GSR and Stress Monitoring Devices, Proximity and Wear-Detection.

📱

Smartwatch Heart-Rate Monitoring

The AS7030B fits smartwatch heart-rate monitoring because its integrated PPG engine samples light modulated by blood vessels as they expand and contract with each heartbeat, delivering HRM and HRV data without external optics. Because the LED drivers, photodiodes, and synchronous demodulator are on one die, the optical path is pre-aligned, reducing mechanical tolerance issues common with discrete PPG designs. In a typical wrist-worn topology, the module sits under the watch glass against the skin, pulsing its LEDs and reading back-photocurrent while the IR proximity channel confirms skin contact before starting a measurement session. The low-power design directly supports the multi-day recharge intervals that smartwatch users expect, per the ams OSRAM datasheet.

🏃

Fitness Band Activity Tracking

For fitness bands, the AS7030B provides continuous optical heart-rate tracking during workouts in a small footprint that suits narrow wristband PCBs. The synchronous demodulator rejects DC ambient interference, which is the dominant error source when a band is worn outdoors, allowing pulse-rate readings to remain valid under daylight exposure. Its multi-wavelength optical solution supports SpO2 estimation in addition to heart rate, letting a single sensor serve both workout intensity and recovery metrics. Power efficiency matters because fitness bands run for days between charges; the AS7030B's low-power architecture, cited by ams OSRAM as a key design goal, keeps the sensor's share of the energy budget small. The IR emitter and dedicated photodiode also add wear-detection so tracking pauses automatically when the device is removed.

💊

Clinical-Grade ECG Wearables and Smart Patches

The AS7030B's embedded ECG channel with low-noise analog front end makes it suitable for smart patches and chest- or arm-placed monitors that record diagnostic-style single-lead ECG alongside PPG. ECG captures the bioelectric potentials generated by the heart and is the reference standard for cardiac rhythm assessment, so combining it with PPG in one module lets a patch cross-validate pulse rate against electrical activity. Designers should feed the module from a clean LDO rail, as in the ams OSRAM evaluation-kit reference design, because microvolt-level ECG signals are sensitive to supply ripple. The I2C output streams samples to the patch MCU, which can run arrhythmia-detection firmware locally or upload raw waveforms over BLE for clinician review.

🧩

SpO2 Pulse-Oximeter Integration

Because photoplethysmography is the underlying method for SpO2 measurement, the AS7030B's multi-wavelength PPG engine can be used for peripheral oxygen saturation estimation in wearable and patch products. The module's integrated optics ensure consistent emitter-photodiode geometry, which is critical because SpO2 computation depends on the ratio of absorbed red and infrared light and is sensitive to optical misalignment. The synchronous demodulator isolates the pulsatile (AC) component of the photocurrent from the large DC ambient component, improving ratio-of-ratios accuracy in ambulatory conditions. Designers should account for skin-tone, motion, and perfusion variability in their calibration firmware, and validate against a reference fingertip oximeter during development using the USB evaluation kit.

🎧

GSR and Stress Monitoring Devices

The AS7030B doubles as an optical measurement system for GSR (galvanic skin resistivity), enabling stress and arousal tracking in the same module used for heart rate. GSR reflects changes in skin conductance driven by sympathetic nervous system activity, and combining it with HRV data gives stress-algorithm developers two complementary physiological channels. The ams OSRAM-supported implementation is demonstrated on MikroElektronika's ECG/GSR Click board, which pairs the AS7030B with standard host headers for rapid algorithm bring-up. In a wearable, the module's GSR measurement runs alongside PPG sessions scheduled by the host MCU over I2C, allowing duty-cycled stress sampling that preserves battery life. Skin temperature from an attached external NTC sensor adds a third stress-relevant input.

🎥

Proximity and Wear-Detection

Beyond vital signs, the AS7030B integrates an infrared emitter with a dedicated photodiode, giving product designers a built-in proximity function for wear detection. In a smartwatch or band, the firmware can poll the proximity channel over I2C before launching a power-hungry PPG session, keeping the optical engine off whenever the device is off-wrist; this materially extends battery life, which aligns with the AS7030B's low-power design goal. The same channel prevents garbage heart-rate readings from being logged when no skin is present, improving data quality in the companion health app. Because the IR elements are inside the module, no external emitter alignment is needed, saving the mechanical design effort that discrete IR proximity solutions typically demand.

Resumo dos produtos recomendados

AS7030B_EVALKIT_BT Bluetooth evaluation kit for firmware prototyping Usado em: Smartwatch Heart-Rate Monitoring, Clinical-Grade ECG Wearables and Smart Patches, GSR and Stress Monitoring Devices AS7030B_EVALKIT_USB USB evaluation kit with reference power-tree schematic Usado em: Smartwatch Heart-Rate Monitoring, Fitness Band Activity Tracking, SpO2 Pulse-Oximeter Integration, Proximity and Wear-Detection
What is the AS7030B sensor and what does it measure?
The AS7030B is a vital-sign biosensor module from ams OSRAM that measures PPG (for heart rate, HRV and SpO2), ECG, GSR (galvanic skin resistivity), and skin temperature via an external NTC sensor. According to the ams OSRAM datasheet, it integrates a low-noise analog front end, an integrated optical solution, and a synchronous demodulator, and outputs data over an I2C interface, making it a multi-modal biometric solution for wearables.
What is the interface of the AS7030B?
The AS7030B communicates over an I2C serial interface, as confirmed by DigiKey's product listing describing it as an 'Optical Sensor I2C Output'. The I2C bus allows a host microcontroller, such as an STM32 or a wearable MCU, to configure measurement sequences and read out PPG waveforms, ECG samples, GSR, and temperature data using standard register access at typical wearable-friendly bus speeds.
What is the price of AS7030B-COLM?
Pricing for the AS7030B-COLM is typically in the mid-single-digit USD range at unit quantity, with volume discounts at 10, 100, and 1000 pieces as of 2026-10-11. Exact distributor pricing fluctuates with stock; DigiKey, Octopart, and LCSC list comparative pricing. For the most accurate and current quote, check the linked distributor listings on this page, since ams OSRAM sensor modules can see price changes between production lots.
Where to buy AS7030B-COLM online?
The AS7030B-COLM can be purchased online from authorized distributors including DigiKey (which lists AS7030B-COLM with same-day shipping availability), Mouser, LCSC, and Ampheo, as well as via Octopart price comparison. Win Source also offers RFQ-based sourcing under the older AMS-TAOS designation. Always buy through authorized channels to ensure genuine ams OSRAM parts with valid date codes for biometric production designs.
Where to download the AS7030B datasheet PDF?
The official AS7030B datasheet PDF is available from ams OSRAM at look.ams-osram.com (document AS7030B_PD000544). Mirror copies are hosted by SparkFun (cdn.sparkfun.com), alldatasheet.com (129-page version), and Octopart. For engineering use, always prefer the manufacturer-hosted PDF because it carries the latest revision of electrical specifications, register maps, and the recommended power-supply schematic.
Is the AS7030B suitable for smartwatch heart-rate monitoring?
Yes. The AS7030B is explicitly designed for fitness bands, smart watches, sports watches, and smart patches, according to the ams OSRAM datasheet. Its photoplethysmography engine measures pulse rate from light modulated by expanding and contracting blood vessels, supporting HRM and HRV. Its low-power design targets multi-day battery life in wrist-worn products, and the integrated IR proximity function prevents false readings when the watch is not worn.
What is the best drop-in replacement for the AS7030B?
There is currently no widely documented pin-to-pin cross-brand drop-in replacement for the AS7030B module; DigiKey's cross-reference tool and the sources reviewed list no direct equivalent. Within the ams OSRAM family, the same part in different packaging suffixes (COLM) is the safest substitution. For new designs needing functional alternatives, Maxim/Analog Devices optical AFEs (such as the MAX8614x family) offer similar PPG/ECG functionality but require a different footprint and redesign.
Can the MAX86150 replace the AS7030B?
Functionally, the Analog Devices MAX86150 also integrates PPG and ECG channels, so it is a functional alternative, but it is NOT a drop-in replacement for the AS7030B. The MAX86150 uses a different package and pinout and lacks the AS7030B's integrated GSR function. Switching requires PCB redesign, firmware changes, and re-verification of optical mechanics, so treat it as a re-design option rather than a substitution on an existing AS7030B board.
AS7030B vs MAX86150 - which is better for a wearable biometric patch?
Choose the AS7030B when you want a fully integrated module with PPG, ECG, GSR, proximity, and NTC temperature support from one footprint, minimizing BOM and optical alignment work. Choose the MAX86150 when you prefer an Analog Devices supply chain and only need PPG plus ECG without GSR. Both target wearables; the AS7030B offers broader modality integration, while the MAX86150 offers a widely documented alternative ecosystem. Neither is pin-compatible with the other.
When should I choose the AS7030B over a discrete PPG plus ECG design?
Choose the AS7030B when board space, BOM count, and optical alignment risk dominate your design. It integrates LEDs, photodiodes, LED drivers, the ECG analog front end, and a synchronous demodulator in one module, eliminating the need to source and align discrete optical components. A discrete PPG LED plus separate AFE approach gives more optical tuning freedom but increases part count, layout complexity, and ambient-light sensitivity. For compact wearables with multi-day battery targets, the integrated module is usually the faster path to market.
Is the AS7030B the same as AS7030B-COLM?
AS7030B is the base product name, while AS7030B-COLM is the full ordering code used by distributors for the shipped module variant; they refer to the same vital-sign sensor silicon. DigiKey lists the product only under AS7030B-COLM. When creating a purchase order or BOM line, always use the complete ordering code AS7030B-COLM so you receive the correct ams OSRAM module packaging rather than a bare-die or alternate suffix.
What supply voltage does the AS7030B need for best ECG and PPG performance?
The precise supply range should be verified in the official datasheet, but ams OSRAM's own evaluation-kit documentation shows the recommended design powering the AS7030B VDD through a low-noise LDO (a TLV702475DBVR with 4.75V output in the kit reference, optionally a single 3.7V LDO). The critical design point is supply cleanliness: switch-mode ripple on VDD directly couples into the microvolt-level ECG and PPG signals, so use dedicated LDO power with good decoupling rather than a shared buck rail.
What are the key specifications of the AS7030B that engineers should know?
Engineers should know these AS7030B facts: it is an ams OSRAM vital-sign module combining PPG and ECG measurement; it supports heart rate, HRV, SpO2, GSR, and skin temperature via external NTC; it communicates over I2C; it integrates a low-noise AFE, integrated optics, and a synchronous demodulator for ambient-light rejection; and it has an IR-based proximity function. Its low-power design targets smartwatches, fitness bands, and smart patches with multi-day battery life, per the official 129-page datasheet.
What development tools exist for the AS7030B?
ams OSRAM offers two evaluation kits: the AS7030B_EVALKIT_USB (USB-connected biometric evaluation kit for Windows) and the AS7030B_EVALKIT_BT (Bluetooth evaluation kit), both listed on Mouser. The kit documentation includes reference schematics showing the recommended LDO-based power tree and sensor connections. Third-party support includes MikroElektronika's ECG/GSR Click board based on the AS7030B, which speeds up prototyping with standard mikroBUS headers before committing to a custom PCB.
Is the AS7030B in stock and what is the lead time?
DigiKey's listing for AS7030B-COLM states 'Buy now, ships today' as of the last verification on 2026-10-11, indicating active stock at unit quantities. Mouser, LCSC, and Ampheo also list the part, which spreads sourcing risk. For production volumes above 1000 pieces, request formal lead-time quotes from ams OSRAM distribution, since ams optical sensor modules historically see allocation windows; stock status should be re-checked at time of order.

Dados de referência de engenharia para AS7030B — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the AS7030B when your wearable needs PPG plus ECG in a single, optically pre-aligned module and you also want GSR, skin temperature, and proximity from the same footprint - typical for smartwatches, fitness bands, and smart patches targeting multi-day battery life. Choose the Analog Devices MAX86150 instead if your product needs only PPG and ECG, you prefer the ADI supply chain, and you are willing to redesign the PCB, since it is not pin-compatible. Choose discrete LED-plus-AFE architectures only when you need custom wavelength selection or optical geometry that the integrated module cannot provide, accepting higher BOM count and mechanical complexity. In all cases budget development time around the official AS7030B_EVALKIT_USB/BT kits for algorithm bring-up before custom hardware.

Comparação com alternativas

Parâmetro Este produto AS7030B-COLM
Package ams OSRAM module (AS7030B-COLM ordering code) Identical module package
Brand ams-OSRAM AG ams-OSRAM AG
Measurement Channels PPG + ECG + GSR + temperature (NTC header) PPG + ECG + GSR + temperature (NTC header)
Interface I2C I2C
Proximity Function Yes (IR emitter + dedicated photodiode) Yes (IR emitter + dedicated photodiode)
Supply Approach (reference design) LDO-fed VDD (TLV702475DBVR 4.75V or single 3.7V LDO, per eval kit) LDO-fed VDD (TLV702475DBVR 4.75V or single 3.7V LDO, per eval kit)
Target Applications Fitness bands, smart watches, sports watches, smart patches Fitness bands, smart watches, sports watches, smart patches
Cross-Brand Drop-In Equivalent None documented in reviewed web data N/A - same part Functional alternative only, NOT pin-compatible (different package/pinout, no GSR)

Principais diferenciais

  • Four biometric modalities in one module (vs MAX86150)
  • Integrated optical proximity for wear detection (vs MAX86150)
  • Fully integrated, pre-aligned optics (vs Discrete LED + AFE PPG designs)

Notas de projeto

Follow the ams OSRAM evaluation-kit reference power scheme: feed the AS7030B VDD from a dedicated low-noise LDO rather than a shared switching regulator. The official kit design derives the sensor supply from a TLV702475DBVR LDO (4.75V output), with a documented alternative of a single 3.7V-output LDO for sensor power. ECG and PPG signals are in the microvolt-to-millivolt range, so buck-converter ripple appearing on VDD degrades signal quality visibly in the captured waveform. Add local bulk and high-frequency decoupling at the module and keep the LED supply path separate from the sensitive AFE path.

Optical and biometric layout hygiene matter more than raw routing speed. Place the AS7030B at the board edge where it faces the skin window, and keep the optical cavity free of solder-mask or component shadowing. Route ECG electrode traces as short as practical, guard them with ground, and keep them away from LED driver return currents to prevent artifacts. Use a solid ground plane under the module and connect the mechanical skin-contact shield to ground to reduce 50/60 Hz mains pickup in the ECG channel.

A frequent mistake is treating the AS7030B as a simple optical sensor and skipping the proximity gate: always check the IR proximity channel before starting PPG sessions so the system does not record invalid heart-rate data off-wrist. Another pitfall is skipping algorithm-level compensation - SpO2 and GSR results depend on skin tone, contact pressure, temperature, and motion, so firmware filtering and calibration against reference instruments (clinical oximeter, reference ECG) are mandatory before release. Start development on the AS7030B_EVALKIT_USB or AS7030B_EVALKIT_BT rather than jumping straight to custom hardware.

Informações de conformidade

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

Compliance data was not present in the provided verified web data. Confirm RoHS/REACH status on the official ams OSRAM product page or datasheet before production sourcing.

Dados verificados em: 2026-10-11 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

AS7030B datasheet PDF AS7030B-COLM buy price ams OSRAM AS7030B AS7030B PPG ECG sensor module AS7030B I2C biometric sensor AS7030B smartwatch heart rate sensor AS7030B vs MAX86150 AS7030B drop-in replacement equivalent AS7030B EVALKIT USB Bluetooth what sensors does the AS7030B have AS7030B GSR SpO2 measurement wearable biosensor module for fitness band

Componentes & termos relacionados

ams OSRAM ams-OSRAM AG AS7030B AS7030B-COLM AS7030B_EVALKIT_USB AS7030B_EVALKIT_BT MAX86150 Analog Devices biometric sensor module PPG photoplethysmography ECG electrocardiography GSR galvanic skin resistivity SpO2 HRV I2C analog front end synchronous demodulator wearable electronics smartwatch fitness band TLV702475DBVR MikroElektronika ECG/GSR Click
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ