BSM100GB60DLC - 600V 100A Dual IGBT Module | Infineon
N.º da peça: BSM100GB60DLC ✗ Fim de vida| Qtd. | Preço unitário | Total |
|---|---|---|
| 1 | $0 | $0,00 |
| 10 | $0 | $0,00 |
| 100 | $0 | $0,00 |
| 500 | $0 | $0,00 |
| 1.000 | $0 | $0,00 |
BSM100GB60DLC Visão geral
A dual IGBT module integrates two insulated-gate bipolar transistors with accompanying freewheeling diodes into a single isolated housing, forming one leg of a three-phase inverter or a complete half-bridge power stage. Within the power semiconductor hierarchy, it sits between discrete IGBTs and complete intelligent power modules (IPMs), serving as the workhorse switching element in power conversion systems.
Key features include a 600V collector-emitter blocking voltage, a 100A DC collector current rating under datasheet-specified conditions, and an N-channel, two-unit (dual) configuration. Infineon highlights its 34 mm 600V dual IGBT module family as a superior solution for frequency-controlled inverter drives, citing optimized switching characteristics such as switching softness and reduced switching losses, which lower EMI filter requirements and improve converter efficiency.
The module carries UL/CSA certification per UL1557 (file E83336) and supports operating temperatures up to 150 degrees C, enabling high power density designs in thermally demanding environments. The isolated baseplate construction allows direct mounting onto liquid-cooled or air-cooled heatsinks with electrical isolation maintained between the silicon and the mounting surface.
Typical applications include variable-frequency motor drives for industrial automation, servo amplifiers, UPS inverters, and general-purpose power conversion equipment. The half-bridge topology directly maps to one inverter phase, so three modules build a complete three-phase drive output stage.
Design consideration: the 100A rating applies only under the datasheet-specified conditions and is not a thermal operating guarantee for every switching condition. Engineers must verify junction temperature under their actual switching frequency, gate drive, and cooling configuration.
This page synthesizes distributor availability data, family cross-references, and practical engineering notes not consolidated in the manufacturer datasheet.
Alternativas drop-in para BSM100GB60DLC — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:
BSM50GB60DLC
✅ Drop-In ⚠️ Especificações não verificadas📋 Alternativa de referência (fora do catálogo)
BSM100GB120DLC
✅ Drop-In ⚠️ Especificações não verificadas📋 Alternativa de referência (fora do catálogo)
BSM50GB120DLC
✅ Drop-In ⚠️ Especificações não verificadas📋 Alternativa de referência (fora do catálogo)
BSM100GB60DLC Classificações máximas e características elétricas
| Collector-Emitter Voltage (VCE) | 600 V |
| DC Collector Current (IC) | 100 A |
| Configuration | Dual (2 units, half-bridge) |
| Polarity | N-Channel |
| Package Type | 34 mm module (MODULE-7) |
| Maximum Operating Temperature | 150 C |
| Certification | UL/CSA UL1557, file E83336 |
| Manufacturer | Infineon Technologies (eupec GmbH) |
| Switching Characteristic | Optimized softness, reduced switching losses |
| Target Application | Frequency-controlled inverter drives |
| Tipo de montagem | Baseplate mount (screw terminal) |
| Status RoHS | unknown |
| Datasheet Pages | 9 pages |
Guia de Configuração de Pinos do BSM100GB60DLC 34 mm module (module-7)
Configuração de pinos para BSM100GB60DLC (pacote 34 mm module (module-7)). Este dispositivo de potência possui terminais de gate, drain e source. Para pacotes não polarizados, consulte o datasheet do fabricante para a orientação exata do pino 1 e detalhes do footprint. Aplicações comuns incluem projeto de fontes de alimentação, acionamento de motores e comutação de cargas.
Nenhum dado detalhado de pinagem disponível para BSM100GB60DLC.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
BSM100GB60DLC é adequado para 6 aplicaçãos: Industrial Variable Frequency Drives, Servo Amplifiers and Motion Control, Uninterruptible Power Supplies (UPS), Welding Power Supplies, Induction Heating Equipment, DC Motor Choppers and Traction Auxiliaries.
Industrial Variable Frequency Drives
The BSM100GB60DLC is explicitly positioned by Infineon as a superior solution for frequency-controlled inverter drives. Its dual (half-bridge) configuration forms one phase leg of a three-phase inverter, so three modules build the complete output stage of a 400V-class AC motor drive. The 600V blocking rating covers DC bus voltages derived from 230-400V AC lines with surge margin, and the 100A DC rating supports motor power in the tens of kilowatts under the datasheet-specified conditions. Optimized switching softness reduces voltage overshoot on long motor cables, easing dv/dt filtering, while reduced switching losses allow switching frequencies typical of industrial drives (2-16 kHz) without excessive heatsink sizing. UL1557 certification (E83336) supports use in certified drive equipment up to the 150 degrees C operating limit.
Recomendado
Servo Amplifiers and Motion Control
Servo amplifiers require a compact, rugged half-bridge power stage with fast, low-loss switching to deliver high dynamic torque from a 320-540V DC bus. The BSM100GB60DLC fits this role with its 600V rating, dual IGBT configuration, and optimized switching characteristics that reduce switching losses at the elevated PWM frequencies (typically 8-20 kHz) used in servo current loops. The switching softness minimizes reverse-recovery-induced overshoot, improving EMI performance inside shielded machine enclosures. The 34 mm screw-terminal package bolts directly to cold plates used in multi-axis servo racks, and the 150 degrees C maximum operating temperature provides headroom for intermittent overload operation common in motion applications. For service replacement of legacy servo drives, this module remains the form-factor-matched choice.
Recomendado
Uninterruptible Power Supplies (UPS)
Online double-conversion UPS inverters in the 10-60 kVA range use three half-bridge modules to synthesize the AC output from a 400V-class DC bus. The BSM100GB60DLC's 600V rating and 100A current capability match this DC bus and output current envelope under datasheet-specified conditions. Reduced switching losses improve UPS efficiency, a headline metric for datacenter procurement, and switching softness limits EMI into the output LC filter, supporting low output THD. The isolated baseplate allows all three modules to share a single air- or liquid-cooled heatsink without additional isolation hardware. UL1557 certification (E83336) eases safety qualification of the UPS assembly. For legacy UPS service and repair, this module preserves the original mechanical and electrical design.
Recomendado
Welding Power Supplies
Inverter-based industrial welding power sources switch high currents at 20-100 kHz from rectified mains, demanding robust half-bridge modules with low switching losses. The BSM100GB60DLC's 600V dual configuration and 100A rating under datasheet-specified conditions suit full-bridge welding inverter architectures on 380-400V three-phase input, where each pair of modules forms the bridge. The soft switching characteristic reduces ringing that would otherwise degrade weld-current control and radiated EMI. The 34 mm module's low-inductance screw-terminal layout supports the fast current edges of hard-switched bridges, and the 150 degrees C maximum operating temperature accommodates the duty-cycle transients of welding. Legacy welder OEM service lines remain the primary use case for this part today.
Recomendado
Induction Heating Equipment
Industrial induction heaters for brazing, forging, and heat treatment use resonant half- or full-bridge IGBT stages at 10-50 kHz driving an LC tank coupled to the work coil. The BSM100GB60DLC provides the 600V blocking and 100A-class conduction required for mid-power resonant inverters fed from a rectified 400V-class supply. Its optimized softness benefits resonant operation, where the module often switches near zero current, further reducing losses and allowing compact liquid-cooled assemblies. The dual module halves the component count of a full bridge and keeps parasitic inductance low between the two switches, reducing voltage overshoot at tank-current reversals. Three modules or paired half-bridges scale the design to higher kilowatt ratings for large forge installations.
Recomendado
DC Motor Choppers and Traction Auxiliaries
DC bus choppers, battery-vehicle auxiliary converters, and legacy DC traction drives use a single half-bridge module as a step-down (buck) chopper stage. The BSM100GB60DLC's dual configuration lets one module serve both the main chopper switch and the freewheeling path, or two independently controlled quadrants of an H-bridge for reversible DC motor drive. The 600V rating covers 72-150V traction batteries with wide margin as well as rectified rail-fed auxiliaries, while the 100A DC rating under datasheet-specified conditions supports traction-adjacent loads such as blowers, pumps, and compressors. Reduced switching losses matter in high-frequency choppers used to shrink filter inductors, and the UL1557 certification (E83336) supports safety approval of auxiliary converter assemblies.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para BSM100GB60DLC — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | BSM50GB60DLC | BSM100GB120DLC | BSM50GB120DLC |
|---|---|---|---|---|
| Package | 34 mm module (MODULE-7) | 34 mm module (same family footprint) | 34 mm module (same family footprint) | 34 mm module (same family footprint) |
| Brand | Infineon (eupec) | Infineon (eupec) | Infineon (eupec) | Infineon (eupec) |
| Collector-Emitter Voltage | 600 V | 600 V | 1200 V | 1200 V |
| DC Collector Current | 100 A | 50 A | 100 A | 50 A |
| Configuration | Dual (2 units) | Dual (2 units) | Dual (2 units) | Dual (2 units) |
| Primary Use Case | 400V-class inverter drives, full 100 A load | Lower-power drives on 400V bus | 480-690V drives at full 100 A | High-voltage auxiliary converters |
Principais diferenciais
- Full 100A rating at 600V in the 34 mm family (vs BSM50GB60DLC)
- Lower conduction-path stress on 400V-class buses (vs BSM100GB120DLC)
- Certified isolation for certified equipment (vs Broker-sourced equivalents)
Notas de projeto
Estimated: the 100A DC rating applies only under the datasheet-specified conditions and is not a thermal guarantee for every switching condition, as the datasheet-derived application note emphasizes. Compute conduction losses as VCE(sat) x IC x duty cycle plus switching losses from Eon/Eoff at your bus voltage and frequency, then size the heatsink so junction temperature stays below 150 degrees C with margin. Use a calibrated thermal interface material and verify baseplate temperature with a thermocouple during worst-case load testing.
Keep the DC bus decoupling loop as small as possible between the module's positive and negative terminals. In screw-terminal 34 mm modules, stray busbar inductance directly sets turn-off voltage overshoot; even with the module's soft switching characteristic, tens of nanohenries of loop inductance at 100A turn-off can add significant overshoot to the 600V bus. Use laminated busbars or snubber capacitors mounted directly across the module terminals for high-current, high-frequency designs.
This is a legacy eupec/Infineon part: confirm authenticity and date codes when buying from broker channels, since counterfeit power modules are common in the obsolete-parts market. Also verify gate drive ratings before substitution - the gate-emitter peak voltage limit is not stated in the retrieved data and must be taken from the datasheet. For mechanical replacement, confirm the mounting hole pattern, because competitor modules with similar ratings may differ in package dimensions and require mechanical redesign.
Informações de conformidade
UL/CSA certified per UL1557, file E83336 (per Infineon product literature). RoHS/REACH status not stated in retrieved data; legacy eupec-era module - request supplier compliance statement.