INA317IDGKT - 50µA Zero-Drift INA | Texas Instruments
N.º da peça: INA317IDGKT ✓ AtivoINA317IDGKT Visão geral
An instrumentation amplifier is a precision differential-input amplifier optimized for measuring small signals superimposed on a larger common-mode voltage. Its internal three-operational-amplifier architecture provides differential gain, high input impedance, and common-mode rejection. The INA317 belongs to the instrumentation amplifier class within the broader operational-amplifier and analog-signal-conditioning hierarchy.
The INA317 combines low offset, low drift, low noise density, and low quiescent current. According to the Texas Instruments product information, its 50nV/√Hz input-noise density extends down to DC, while its common-mode rejection reaches 100dB at a gain of 10 or higher. Autocalibration techniques are used to maintain precision over the extended industrial temperature range.
The INA317 supports supply voltages as low as 1.8V, equivalent to ±0.9V for a dual-supply arrangement. A single external gain resistor sets the closed-loop gain from 1 to 1000 using G = 1 + (100kΩ/RG). Rail-to-rail output operation allows the output to use nearly the available output-voltage range, which is useful in compact low-voltage sensor systems.
Typical applications include portable sensor acquisition, battery-powered measurement systems, bridge-sensor interfaces, biomedical instrumentation, and precision current sensing. Its low 50µA quiescent current is particularly valuable for portable equipment, while the 8-pin VSSOP package supports compact layouts.
Designers should place the gain resistor close to the RG pins to minimize added noise and parasitic resistance. Decoupling capacitors should be connected directly to the supply pins, and the REF connection should be driven only when the circuit does not require the default midscale reference behavior. Input and output settling should be checked across the intended gain and signal bandwidth.
Alternativas drop-in para INA317IDGKT — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
INA333IDGKR
✅ Drop-In ⚠️ Especificações não verificadas📋 Alternativa de referência (fora do catálogo)
INA326IDGKR
✅ Drop-In ⚠️ Especificações não verificadas📋 Alternativa de referência (fora do catálogo)
INA317IDGKT Classificações máximas e características elétricas
| Device Type | Precision instrumentation amplifier |
| Amplifier Count | 1 circuit with 3-operational-amplifier architecture |
| Corrente de alimentação | 50µA typical |
| Minimum Total Supply Voltage | 1.8V |
| Dual-Supply Operating Range | ±0.9V minimum |
| Offset Voltage | 75µV at gain ≥100 |
| Offset Voltage Drift | 0.3µV/°C at gain ≥100 |
| Input Noise Density | 50nV/√Hz extending down to DC |
| Common-Mode Rejection | 100dB at gain ≥10 |
| Gain Range | 1 to 1000 |
| Gain Equation | G = 1 + (100kΩ/RG) |
| Tipo de saída | Rail-to-rail output |
| Faixa de temperatura de operação | -40°C to +125°C |
| Encapsulamento | 8-pin VSSOP surface-mount package |
| Tipo de montagem | Surface mount |
Guia de Configuração de Pinos do INA317IDGKT 8-pin vssop surface-mount package
Configuração de pinos para INA317IDGKT (pacote 8-pin vssop surface-mount package). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.
Nenhum dado detalhado de pinagem disponível para INA317IDGKT.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
INA317IDGKT é adequado para 6 aplicaçãos: Battery-Powered Sensor Acquisition, Precision Bridge-Sensor Front End, Portable Medical Monitoring, Precision Current Sensing, Industrial Pressure and Strain Measurement, Low-Voltage Data Acquisition.
Battery-Powered Sensor Acquisition
The INA317IDGKT fits battery-powered sensor acquisition because its 50µA typical quiescent current complements low-power sensor systems, while its 1.8V minimum total supply supports compact dual-rail designs. The 75µV offset voltage and 0.3µV/°C drift at gains of 100 or higher help preserve slow-signal accuracy as battery conditions and ambient temperature change. A typical implementation places the amplifier between a resistive sensor and a low-power ADC, with the external gain resistor connected close to RG. Designers should include input protection if the sensor leads are exposed to electrostatic discharge or transient voltage, and should account for the complete sensor, converter, and ADC power budget rather than the amplifier current alone.
Recomendado
Precision Bridge-Sensor Front End
The INA317IDGKT is suitable for bridge-sensor front ends because its differential input architecture, 100dB common-mode rejection at gain ≥10, and low offset support accurate extraction of small millivolt-level bridge signals. A single external resistor sets the gain according to G = 1 + (100kΩ/RG), allowing the amplifier to be paired with an excitation source and matched bridge network. The rail-to-rail output helps maximize usable signal range in a low-voltage system. Designers must verify the bridge excitation voltage, input common-mode range, and output swing in the manufacturer datasheet, and should use a low-noise excitation source to avoid degrading the bridge signal before amplification.
Recomendado
Portable Medical Monitoring
The INA317IDGKT can support compact medical-monitoring signal chains where low power and low drift are important. Its 50µA typical supply current limits amplifier overhead in wearable or portable equipment, while the 75µV offset and 0.3µV/°C drift reduce temperature-dependent measurement error. The rail-to-rail output and adjustable gain provide flexibility when conditioning low-level sensor outputs. For acquisition electrodes, biopotential signals, or pressure sensors, designers must add suitable input protection, define the REF connection for the required output bias, and verify that common-mode and output ranges satisfy the chosen sensor excitation. Medical designs also require application-specific safety and validation work.
Recomendado
Precision Current Sensing
The INA317IDGKT is appropriate for low-level current measurements when low offset and drift are more important than high-bandwidth response. Its 50nV/√Hz noise density extends down to DC, supporting accurate measurement of slowly varying shunt voltage, and the external gain resistor permits a single shunt to be scaled for the ADC input range. The amplifier’s 50µA quiescent current also reduces overhead in portable or energy-limited equipment. Designers should keep shunt connections short, use a Kelvin connection where practical, and check that the common-mode voltage remains within the permitted range. An RC filter at the input can control high-frequency noise, but its added impedance and settling effects must be included in the error analysis.
Recomendado
Industrial Pressure and Strain Measurement
The INA317IDGKT suits industrial pressure and strain-gauge systems that require low offset drift over changing temperatures. At gains of 100 or higher, the specified 75µV offset and 0.3µV/°C drift help maintain accuracy in systems where the sensor output is small relative to its excitation voltage. The high common-mode rejection at gain ≥10 reduces susceptibility to shared supply and ground disturbances. A practical circuit uses the amplifier close to the sensor, a dedicated excitation source, and an ADC positioned downstream. Designers should assess bridge nonlinearity, excitation drift, input overvoltage, connector noise, and the bandwidth needed for static versus dynamic pressure measurements.
Recomendado
Low-Voltage Data Acquisition
The INA317IDGKT is well suited to low-voltage data-acquisition modules that must process small differential signals without adding excessive supply demand. Its 1.8V minimum total supply, 50µA typical current, and rail-to-rail output support compact, low-energy acquisition channels. The external gain-setting network allows the same amplifier to cover multiple sensor ranges, while the 8-pin VSSOP package saves board area. In a multichannel design, each channel requires stable reference and decoupling arrangements, and the ADC input range must be coordinated with the gain selection. Engineers should confirm input bias-current effects, noise performance, settling time, and exposed-pad requirements directly from the manufacturer documentation before layout release.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para INA317IDGKT — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | INA333IDGKR | INA326IDGKR |
|---|---|---|---|
| Package | 8-pin VSSOP | 8-pin VSSOP | 8-pin VSSOP |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Device Type | Zero-drift instrumentation amplifier | Zero-drift instrumentation amplifier | Precision instrumentation amplifier |
Principais diferenciais
- Higher supported gain range (vs INA333IDGKR)
- Documented micro-power operation (vs INA333IDGKR)
- Precision offset and drift at higher gain (vs INA326IDGKR)
Notas de projeto
Place the external gain-setting resistor directly between the two RG pins and keep the connection as short as practical. Long RG traces add parasitic resistance, temperature gradients, and noise pickup, all of which can degrade the effective gain and offset performance. Use a grounded guard or quiet analog-plane arrangement around the RG network if the layout exposes it to leakage or switching-node interference.
Do not assume that matching packages guarantees a drop-in replacement. Before substituting INA333IDGKR or INA326IDGKR, compare the complete pin-description table, gain equation, reference behavior, input and output common-mode limits, supply range, offset, drift, noise, bandwidth, and exposed-pad requirements. The INA317 supports a gain range of 1 to 1000, so a lower-gain alternative may require different resistor values and a different system gain plan.
Connect the supply bypass capacitor directly to the supply and ground pins, and route sensitive differential inputs away from switching regulators, relay contacts, inductors, and high-current return paths. For bridge or shunt measurements, use a differential input route and minimize the input loop area. These measures are especially important because the amplifier’s low-noise behavior cannot recover signal already corrupted by board-level coupling.
Informações de conformidade
The Texas Instruments product information identifies the INA317 as an active precision amplifier, but it does not explicitly state the requested compliance attributes for this ordering code.