Analog Devices

LTC485MJ8 - Low-Power RS485 Transceiver | Analog Devices

N.º da peça: LTC485MJ8 ✗ Fim de vida
5 V Vdss 1.8 mA Id RS485 and RS422 Rds(on) 8-pin CERDIP Package
MOQ: 1 |

LTC485MJ8 Visão geral

The Analog Devices LTC485MJ8 is a low-power, half-duplex differential bus transceiver for RS485 multipoint networks and RS422 systems, supplied from a single 5 V source and offered in an 8-pin CERDIP package. Its key characteristics include 1.8 mA typical supply current, ±10 kV ESD protection, 28 ns typical driver propagation delay, 4 ns driver skew, and an extended common-mode range extending from +12 V to -7 V.

An RS485 transceiver is an interface integrated circuit that combines a differential line driver and differential receiver on one chip. It converts logic-level signals into balanced bus voltages and converts differential bus signals back into receiver-compatible logic. This electrical layer sits beneath protocols such as Modbus and sits above the physical RS485 bus, where it improves noise immunity and allows multiple nodes to communicate over longer distances than an unbalanced single-ended interface.

The LTC485 family uses CMOS circuitry to reduce power consumption while preserving ruggedness against overload and ESD damage. Its half-duplex arrangement means the bus driver and receiver share the same differential pair, so software or hardware must control the transmit-enable signal to prevent simultaneous driving and receiving. The driver is designed for low propagation delay and controlled skew, while the extended common-mode range helps the device remain operational when ground-potential differences exist between connected systems.

According to the Analog Devices LTC485 product documentation, the device also meets RS422 requirements. The 1.8 mA typical operating current is valuable in distributed bus nodes that may operate from limited power budgets. Typical driver propagation delay is 28 ns with 4 ns skew, making the interface suitable for control networks, instrumentation links, industrial monitoring equipment, and factory-automation systems where deterministic timing and bus fault tolerance are important.

Typical implementations place the LTC485MJ8 between a host UART or microprocessor and a twisted-pair bus. A typical node includes local decoupling, a termination resistor at each physical end of the bus, biasing resistors to establish a fail-safe idle state, and protection appropriate to the installation environment. The transceiver should be connected to the interface ground with a controlled return path, especially when distant devices can develop ground-potential offsets.

Designers must verify the board footprint and pin assignments before substitution, particularly when moving between ceramic, plastic, and surface-mount LTC485 variants. Decoupling capacitors should be placed directly beside the supply and ground pins, while the differential route should remain short and appropriately terminated. The principal trade-off is the manual half-duplex direction control, which reduces component count but requires the controller to manage turnaround timing.

This page consolidates the device function, electrical limits, application guidance, package details, lifecycle information, and verified drop-in alternatives into an engineering-focused reference for evaluating the LTC485MJ8 in RS485 and RS422 interface designs.

Alternativas drop-in para LTC485MJ8 — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

LTC485IJ8

✅ Drop-In ⚠️ Especificações não verificadas
📦 8-pin CERDIP
Operating-temperature range is approximately -40 °C to 85 °C versus -55 °C to 125 °C for LTC485MJ8, reducing cold coverage by 15 °C and hot coverage by 40 °C

📋 Alternativa de referência (fora do catálogo)

LTC485CJ8

✅ Drop-In ⚠️ Especificações não verificadas
📦 8-pin CERDIP
Operating-temperature range is approximately 0 °C to 70 °C versus -55 °C to 125 °C for LTC485MJ8, reducing cold coverage by 55 °C and hot coverage by 55 °C

📋 Alternativa de referência (fora do catálogo)

LTC485MJ8 Especificações

Product Type RS485/RS422 half-duplex transceiver
Transceiver Configuration 1 transmitter, 1 receiver
Tensão de alimentação 5 V
Typical Supply Current 1.8 mA
Bus Common-Mode Range +12 V to -7 V
ESD Protection Over ±10 kV
Typical Driver Propagation Delay 28 ns
Driver Skew 4 ns
Communication Mode Half-duplex
Supported Standards RS485 and RS422
Power-Saving Technology CMOS
Encapsulamento 8-pin CERDIP
Tipo de montagem Through-hole

Configuração de pinos do LTC485MJ8

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pino 1 RO — Receiver output
Pino 2 RE — Receiver enable, active low
Pino 3 DE — Driver enable
Pino 4 DI — Driver input
Pino 5 GND — Ground
Pino 6 Y — Non-inverting driver output
Pino 7 Z — Inverting driver output
Pino 8 VCC — Supply voltage

Aplicações típicas

LTC485MJ8 é adequado para 6 aplicaçãos: Industrial RS485 Control Networks, Building Automation and HVAC Equipment, Instrumentation and Data Acquisition, Factory Automation Equipment, Telecom and Remote Monitoring, Process and Environmental Monitoring.

🏭

Industrial RS485 Control Networks

The LTC485MJ8 fits distributed industrial control nodes that exchange commands and sensor readings over a wired RS485 bus. Its half-duplex architecture supports bidirectional communication on one differential pair, while the 1.8 mA typical supply current is useful when each remote node has limited power. The +12 V to -7 V common-mode range provides tolerance for ground-potential differences between cabinets. The bus should be properly terminated and biased, and the controller should delay receiver enable after transmission to avoid contention.

🏠

Building Automation and HVAC Equipment

In building HVAC and automation controllers, the LTC485MJ8 can connect a microcontroller to thermostats, sensors, actuators, and variable-air-volume equipment over a shared RS485 network. Its 28 ns typical driver propagation delay and 4 ns skew support controlled switching on relatively fast digital buses. Low-power CMOS operation helps satisfy the power budget of compact controllers. Designers should use controlled ground routing, surge protection appropriate to building wiring, and fail-safe biasing so the receiver remains in a defined state when no device is transmitting.

📟

Instrumentation and Data Acquisition

The LTC485MJ8 is suitable for laboratory and industrial instrumentation that must transfer measurements between a controller and remote sensor or signal-conditioning module. The differential receiver rejects common-mode noise, while the extended common-mode range provides additional margin when the remote module references a different ground potential. The low 1.8 mA typical supply current benefits compact data-acquisition equipment. Keep the differential trace geometry consistent, place the transceiver close to the connector, and use a twisted pair for reliable operation outside controlled laboratory wiring.

🤖

Factory Automation Equipment

Factory automation controllers can use the LTC485MJ8 to connect programmable logic, motion-control equipment, remote I/O modules, and status displays over an RS485 segment. The 5 V supply operation suits modern embedded systems, and the transceiver’s overload and ESD robustness is valuable in industrial environments. Because the device is half-duplex, firmware must manage bus direction and turnaround timing. A controlled ground reference, end-point termination, and appropriately rated surge protection are essential when the bus extends between machines or through long cable runs.

🌐

Telecom and Remote Monitoring

The LTC485MJ8 can provide a physical interface between a remote monitoring controller and distributed sensors over an RS485 network. Its low typical supply current of 1.8 mA reduces the power burden on remote equipment, and the RS422 compatibility broadens its use in point-to-point and specialized instrumentation links. The common-mode range of +12 V to -7 V helps manage ground offsets between distributed modules. Use surge arrestors or other network protection when cables leave the equipment enclosure or connect to external lines.

🌡️

Process and Environmental Monitoring

Process plants and environmental monitoring stations often distribute temperature, pressure, humidity, and flow measurements over an RS485 bus. The LTC485MJ8 provides the differential driver and receiver needed to connect an embedded controller to remote measurement nodes while maintaining low supply consumption. Its extended common-mode tolerance helps accommodate ground differences between separately powered sensors. The bus topology, baud rate, cable length, termination, and biasing must be planned together because excessive loading or improper termination can reduce reliability even when individual devices operate correctly.

What is the LTC485MJ8?
The LTC485MJ8 is a low-power, half-duplex RS485 and RS422 differential transceiver from Analog Devices. It combines one driver and one receiver in an 8-pin CERDIP package, operates from a single 5 V supply, and has a typical supply current of 1.8 mA. According to the Analog Devices LTC485 product documentation, its extended common-mode range extends from +12 V to -7 V for robust communication between devices with differing ground potentials.
Where can I download the LTC485MJ8 datasheet PDF?
The official LTC485 datasheet and product information are available through the Analog Devices LTC485 product page at analog.com/en/products/ltc485.html. That page contains the manufacturer documentation for the transceiver family and electrical characteristics. The LTC485MJ8 is the military-temperature, 8-pin CERDIP ordering option. Use the package and ordering-code information in the manufacturer documentation when confirming pin assignments and variant-specific limits.
Where is the LTC485MJ8 pinout located?
The LTC485MJ8 pinout is shown in the manufacturer datasheet under the device pin descriptions and package drawings for the 8-pin CERDIP option. The functional connections are receiver output, receiver enable, driver enable, driver input, ground, driver non-inverting output, driver inverting output, and supply. Before routing a board or substituting another family member, assign physical pins from the package drawing for the exact ordering code.
What are the key specifications of LTC485MJ8 that engineers should know?
The LTC485MJ8 provides a single-driver, single-receiver half-duplex interface with 5 V operation, 1.8 mA typical supply current, and over ±10 kV ESD protection. According to the Analog Devices LTC485 documentation, typical driver propagation delay is 28 ns with 4 ns skew. Its RS485 common-mode range extends from +12 V to -7 V, and the family also supports RS422 applications.
Is LTC485MJ8 suitable for RS485 industrial networks?
Yes, LTC485MJ8 is suitable for RS485 industrial networks that require a half-duplex transceiver with extended common-mode tolerance. Its +12 V to -7 V range accommodates ground-potential differences between distributed nodes, while the low 1.8 mA typical supply current suits remote equipment. The Analog Devices documentation also identifies RS422 compatibility and ESD protection over ±10 kV as important interface characteristics.
How do I use the LTC485MJ8 with a UART?
Connect the LTC485MJ8 driver input to the UART transmit line, receiver output to the UART receive line, and use the enable pins to control half-duplex direction. Place local supply decoupling close to the device, terminate the bus ends with the resistance specified by the system, and bias the bus for a defined idle state. The Analog Devices datasheet provides the detailed logic and timing information needed to coordinate transmitter turnaround.
What is the difference between LTC485MJ8 and LTC485IJ8?
The LTC485MJ8 and LTC485IJ8 belong to the same LTC485 family, but their ordering codes identify different temperature grades. The M-grade device targets approximately -55 °C to 125 °C, while the I-grade device targets approximately -40 °C to 85 °C; the M-grade therefore extends about 15 °C colder and 40 °C hotter. Both use an 8-pin CERDIP package, making their principal functional difference the qualified temperature range.
What is the difference between LTC485MJ8 and LTC485CJ8?
The LTC485MJ8 is intended for approximately -55 °C to 125 °C operation, whereas the LTC485CJ8 is specified for approximately 0 °C to 70 °C. The M-grade option therefore adds about 55 °C of low-temperature capability and 55 °C of high-temperature capability. Both use the same 8-pin CERDIP family architecture and are pin-compatible, but the CJ8 should not replace an MJ8 in equipment exposed to temperature extremes.
When should I choose LTC485MJ8 instead of LTC485IJ8?
Choose LTC485MJ8 when the transceiver must operate across a broad temperature range extending to approximately -55 °C and 125 °C. LTC485IJ8 is more appropriate when the enclosure remains within roughly -40 °C to 85 °C. Both provide the same low-power RS485/RS422 transceiver function in an 8-pin CERDIP package, so temperature qualification and long-term availability should guide the selection.
Can LTC485IJ8 replace LTC485MJ8 in a design?
LTC485IJ8 can serve as a pin-compatible replacement only when the required operating temperature remains within approximately -40 °C to 85 °C. Its temperature range does not cover the full -55 °C to 125 °C capability of LTC485MJ8, so it is unsuitable where the assembly operates at either cold or hot extremes. Verify the system temperature envelope and all manufacturer limits before approving the substitution.
What can replace LTC485MJ8?
The closest documented same-package replacement is LTC485IJ8, which retains the 8-pin CERDIP configuration but narrows the operating range from approximately -55–125 °C to -40–85 °C. LTC485CJ8 is also pin-compatible in the same package, but its approximately 0–70 °C rating is less suitable for industrial temperature extremes. Use the Request a Quote form on this page to confirm availability and sourcing for the required grade.
What is the best Analog Devices equivalent for LTC485MJ8?
LTC485IJ8 is the closest Analog Devices alternative when the system can operate within -40 °C to 85 °C and the 8-pin CERDIP footprint is acceptable. It preserves the LTC485 low-power RS485/RS422 architecture but does not provide the MJ8’s full -55 °C to 125 °C rating. LTC485CJ8 offers a still narrower commercial temperature range. No cross-brand drop-in replacement was established for the exact 8-pin CERDIP footprint.
Where can I buy LTC485MJ8 online?
Use the Request a Quote form on this page to request LTC485MJ8 availability, lead time, and minimum-order details. The part is listed as obsolete by a distributor, so supply status and traceability should be confirmed before committing it to a new design. The manufacturer identifies the underlying LTC485 family product, while the obsolete lifecycle classification applies to this specific ordering code.
What is the price of LTC485MJ8?
Pricing for LTC485MJ8 should be requested through the Request a Quote form on this page because the device is obsolete and current supply may be limited. The structured price fields on this page are populated only when a qualifying quantity-based listing for the exact MPN is available. A request should specify the required quantity and traceability requirements so the current commercial position can be reviewed.
Is LTC485MJ8 in stock and what is its lead time?
LTC485MJ8 is classified as obsolete, and its current stock and lead time should be confirmed through the Request a Quote form on this page. At least one distributor listing reports inventory, but that status can change and does not establish future allocation. For a new production build, request written confirmation of quantity, lot traceability, date code, and manufacturing status before placing the order.

Dados de referência de engenharia para LTC485MJ8 — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose LTC485MJ8 when an existing design requires the full approximately -55 °C to 125 °C temperature range, a single 5 V supply, low-power RS485/RS422 operation, and an 8-pin CERDIP footprint. Choose LTC485IJ8 when the assembly remains within approximately -40 °C to 85 °C and the broader LTC485MJ8 temperature rating is unnecessary; it preserves the same package and principal interface characteristics. Choose LTC485CJ8 only for environments constrained to approximately 0–70 °C. Because the target ordering code is obsolete, confirm lifecycle strategy, traceability, and supply before starting a new production release. For a new design, compare current RS485 transceivers as well, since newer products may offer smaller packages, higher data rates, lower supply current, or improved protection. Any replacement must be checked for pinout, enable-logic polarity, common-mode range, bus loading, and temperature coverage rather than package alone.

Comparação com alternativas

Parâmetro Este produto LTC485IJ8 LTC485CJ8
Brand Analog Devices Analog Devices Analog Devices
Package 8-pin CERDIP 8-pin CERDIP 8-pin CERDIP
Transceiver Configuration 1 driver, 1 receiver 1 driver, 1 receiver 1 driver, 1 receiver
Communication Mode Half-duplex Half-duplex Half-duplex
Supply Voltage 5 V 5 V 5 V
Typical Supply Current 1.8 mA 1.8 mA 1.8 mA
Operating Temperature Range Approximately -55 °C to 125 °C Approximately -40 °C to 85 °C Approximately 0 °C to 70 °C
RS485 Common-Mode Range +12 V to -7 V +12 V to -7 V +12 V to -7 V
Typical Driver Propagation Delay 28 ns 28 ns 28 ns
Driver Skew 4 ns 4 ns 4 ns
ESD Protection Over ±10 kV Over ±10 kV Over ±10 kV

Principais diferenciais

  • Broadest temperature qualification among the listed drop-in options (vs LTC485IJ8)
  • Maintains the same low-power RS485 interface characteristics (vs LTC485CJ8)
  • Pin-compatible family architecture supports controlled substitution (vs LTC485IJ8)

Notas de projeto

Place the supply bypass capacitor directly between pin 8 and pin 5, with a short ground path to minimize switching and high-frequency impedance. Route the Y and Z differential outputs to the bus connector as a closely coupled pair. If the connector is separated from the transceiver by more than a few centimeters, add suitable protection at the connector and provide a controlled chassis-to-logic surge-return path.

Implement fail-safe biasing so the bus has a defined differential state when all nodes are idle. Install termination only at the two physical ends of the bus, not at every node. Keep the transceiver ground connected to the system ground, and evaluate ground-potential offsets and surge paths before connecting external cable wiring. A logic analyzer on the differential pair can help distinguish timing, termination, and contention problems.

Do not enable the driver and receiver simultaneously during a bus turnaround. The LTC485MJ8 is half-duplex, so the controller must deassert the driver before enabling the receiver and must allow adequate propagation and settling time. Also verify that any replacement uses the correct 8-pin CERDIP footprint and temperature grade; a pin-compatible device with a narrower temperature range can fail outside its specified environment.

Informações de conformidade

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

No specific RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification statement was established for the LTC485MJ8 ordering code.

Dados verificados em: 2026-11-09 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

LTC485MJ8 LTC485MJ8 datasheet LTC485MJ8 datasheet pdf LTC485MJ8 pinout LTC485MJ8 specifications LTC485MJ8 equivalent LTC485MJ8 replacement LTC485MJ8 vs LTC485IJ8 LTC485MJ8 RS485 transceiver LTC485MJ8 price Analog Devices LTC485MJ8 LTC485MJ8 8 pin CERDIP

Componentes & termos relacionados

Analog Devices LTC485MJ8 LTC485IJ8 LTC485CJ8 RS485 RS422 differential transceiver interface transceiver half-duplex communication differential line driver differential receiver CMOS common-mode range ESD protection 8-pin CERDIP ceramic dual in-line package through-hole package UART industrial control network building automation data acquisition factory automation process monitoring termination resistor fail-safe biasing
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ