9 V DC Vdss 12 µA Id 8.2 MΩ Rds(on) 16-DIP (0.300 inch, 7.62 mm) Package
MOQ: 1 |

MC14468P Visão geral

The NXP Semiconductors MC14468P is a low-power CMOS ionization smoke detector IC with interconnect, operating from a 9 V supply in a 16-pin through-hole DIP package. It combines a 12 µA supply current with an ionization-sensor interface, an 8.2 MΩ chamber resistance, and a 0.1 nF external capacitor reference. The IC drives an external piezoelectric transducer when smoke is detected and supports systems designed around UL 217 and UL 268 requirements.

An ionization smoke detector IC is a specialized sensor-interface and alarm-control device. It belongs to the smoke detector IC category, which sits under sensor and detector interfaces, smoke detection, and broader building safety electronics. Unlike a photoelectric detector, an ionization system uses a radiation-based ionization chamber whose sensing characteristics change when smoke enters the chamber. The MC14468P evaluates that condition and controls the alarm path.

Key features include a 9 V DC operating supply, very low 12 µA supply current, an ionization input interface, voltage output behavior, and direct support for an external piezoelectric sound element. Its 16-pin DIP package supports conventional through-hole assembly, while the tube packaging format supports bulk production handling. The specified operating range is -10°C to +60°C.

The MC14468P is intended to reduce the component count required to implement an ionization smoke alarm. According to the NXP manufacturer datasheet, the device operates with an ionization chamber and a small number of external components, detects smoke, and activates an alarm through an external piezoelectric transducer and internal drivers. Its interconnect capability provides a dedicated route for integrating the detector into a broader alarm or signaling system.

Typical applications include residential smoke alarms, commercial building-alarm panels, interconnected household warning systems, industrial smoke-detection equipment, and retrofit designs that require a through-hole DIP footprint. Product designers should confirm that the selected ionization chamber, resistor, capacitor, buzzer, power supply, and PCB layout satisfy the safety requirements applicable to the finished detector.

The principal design consideration is the detector network around the IC. The verified 8.2 MΩ chamber resistance and 0.1 nF capacitor values are application references rather than universal substitutions, so engineers should use the manufacturer datasheet and applicable UL requirements when calculating network values, timing, sensitivity, and fault conditions.

This product record combines verified NXP and distributor information with an honest comparison of available drop-in data. It also identifies where pricing, detailed pin functions, and verified lifecycle-specific electrical limits remain unavailable, preventing unsupported replacement claims or unverified PCB-reuse assumptions.

Alternativas drop-in para MC14468P — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

MC14468

✅ Drop-In ⚠️ Especificações não verificadas
📦 16-DIP (0.300 inch, 7.62 mm)
Base-family ordering designation versus MC14468P; the documented 9 V supply and 12 µA supply current are identical, a 0% difference in those two verified ratings.

📋 Alternativa de referência (fora do catálogo)

MC14468P Classificações máximas e características elétricas

Product Type Ionization smoke detector IC with interconnect
Tensão de alimentação 9 V DC
Corrente de alimentação 12 µA
Temperatura de operação -10°C to +60°C
Ionization Chamber Resistance 8.2 MΩ
External Capacitor 0.1 nF
Input Type Ionization input
Tipo de saída Voltage output
Alarm Output External piezoelectric transducer
Technology Low-power CMOS
Interconnect Supported
Encapsulamento 16-DIP (0.300 inch, 7.62 mm)
Tipo de montagem Through-hole
Packaging Tube
Compliance References UL 217 and UL 268 system requirements

Guia de Configuração de Pinos do MC14468P 16-dip (0.300 inch, 7.62 mm)

Configuração de pinos para MC14468P (pacote 16-dip (0.300 inch, 7.62 mm)). A numeração dos pinos, funções e diagramas de conexão estão definidos no datasheet do fabricante. Consulte-o para o footprint exato e diretrizes de soldagem.

Diagrama de pinagem do pacote 16-dip (0.300 inch, 7.62 mm) para MC14468P

Nenhum dado detalhado de pinagem disponível para MC14468P.

Consulte a ficha técnica para a configuração completa dos pinos.

Aplicações típicas

MC14468P é adequado para 6 aplicaçãos: Residential Ionization Smoke Alarm, Interconnected Household Alarm Network, Commercial Building Alarm Panel, Industrial Smoke Detection Equipment, Legacy Smoke Alarm Retrofit, Battery-Backed Safety Sensor.

🏠

Residential Ionization Smoke Alarm

The MC14468P fits a residential ionization smoke alarm because it combines a 9 V DC supply, 12 µA supply current, and an ionization-sensor interface with external piezoelectric alarm support. The IC can operate with an ionization chamber and a small number of external components, allowing a conventional alarm architecture to use a 16-pin DIP footprint. The verified chamber references of 8.2 MΩ and 0.1 nF provide a starting point for the sensing network, but final sensitivity and timing must match the applicable safety requirements. Designers should also budget for the higher load imposed by the external transducer and verify that the complete alarm remains compliant with the required smoke-alarm standards.

🧩

Interconnected Household Alarm Network

The MC14468P is appropriate for an interconnected household warning network because the manufacturer datasheet explicitly identifies the IC as a smoke detector with interconnect. Each detector can evaluate an ionization chamber and drive a local external piezoelectric transducer while participating in a broader alarm arrangement. Its 12 µA specified supply current is valuable when standby power consumption affects battery-life calculations. The engineer must still validate the interconnect voltage levels, line topology, fault behavior, and timing in the system design because those detailed interface conditions are not included in the supplied search excerpts.

🏭

Commercial Building Alarm Panel

A commercial building alarm panel can use the MC14468P where a legacy design requires ionization sensing rather than photoelectric detection and retains a through-hole DIP assembly. The 16-pin package supports conventional PCB routing, while the 9 V operating supply and 12 µA specified current suit established low-power detector circuits. Because the MC14468P is identified as obsolete, equipment maintenance may benefit more than new panel construction. Before integrating it into a commercial system, confirm the detector network, alarm-level requirements, diagnostic behavior, environmental limits, and any certification obligations of the completed alarm equipment.

🏭

Industrial Smoke Detection Equipment

The MC14468P can support specialized industrial smoke-detection equipment when the original design depends on an ionization chamber and the operating environment remains within -10°C to +60°C. Its low-power CMOS operation, specified 12 µA supply current, and external piezoelement drive capability make it suitable for continuously monitored detection nodes. The sensing network still requires careful validation because industrial hazards can alter smoke characteristics, airflow, humidity, and chamber behavior. Use the official datasheet for timing and electrical limits, and treat the 8.2 MΩ and 0.1 nF values as verified reference-network data rather than universal design constants.

🔧

Legacy Smoke Alarm Retrofit

The MC14468P is especially relevant to a retrofit that must preserve an existing 16-DIP ionization-smoke-detector PCB and its surrounding analog network. Its through-hole package avoids the need to redesign for a surface-mount footprint, and the low 12 µA specified supply current supports continued operation from constrained alarm supplies. A successful retrofit depends on exact pin compatibility, correct chamber and capacitor values, buzzer drive requirements, and an available traceable part. The obsolete lifecycle status means engineers should not assume future replenishment and should evaluate an internally qualified alternative before using the MC14468P in a new production run.

⚡

Battery-Backed Safety Sensor

The MC14468P can serve as the sensing element of a battery-backed smoke-safety device because its verified supply current is 12 µA during the specified operating condition. This low CMOS current helps preserve standby capacity, although the complete power budget must add the external piezoelectric transducer, chamber network, indicator electronics, and any interconnect circuitry. The device operates from 9 V DC and supports an external piezoelement, matching many legacy alarm architectures. Before release, engineers should test low-battery behavior, alarm-current duration, temperature performance across -10°C to +60°C, and all failure modes required by the finished product standard.

What is the MC14468P?
The MC14468P is a low-power CMOS ionization smoke detector IC with interconnect in a 16-pin DIP package. According to the NXP manufacturer datasheet, it detects smoke using an ionization chamber and external components, then activates an external piezoelectric transducer through internal drivers. Its specified supply is 9 V DC, and its listed supply current is 12 µA.
What voltage does the MC14468P operate from?
The MC14468P operates from a 9 V DC supply. This operating voltage is stated in the verified TME product data and is consistent with the NXP manufacturer datasheet for this smoke detector family. Designers should use a supply capable of supporting the detector IC, ionization chamber network, and connected alarm circuitry while observing all applicable polarity and voltage limits in the datasheet.
How much current does the MC14468P consume?
The specified MC14468P supply current is 12 µA. This low-current CMOS operating figure supports use in battery-backed smoke detection systems where standby power matters. The value comes from the verified component listing; total alarm current will be higher when the external piezoelectric transducer and other external circuitry operate, so system-level budgeting must include those loads.
What sensor type does the MC14468P support?
The MC14468P supports an ionization-type smoke detector input. According to the NXP manufacturer datasheet, it is intended to operate with an ionization chamber and a small number of external components. The supplied application references identify an 8.2 MΩ chamber resistance and a 0.1 nF capacitor, which engineers should evaluate against the sensitivity, timing, and safety requirements of the finished alarm.
Where can I download the MC14468P datasheet PDF?
The official MC14468P datasheet PDF is available from NXP at https://www.nxp.com/docs/en/data-sheet/MC14468.pdf. The document covers the low-power CMOS ionization smoke detector with interconnect and identifies operation in systems designed to comply with UL 217 and UL 268 specifications. It is the preferred source for application circuitry, electrical limits, timing, and pin-function information.
Where can I find the MC14468P pinout?
The MC14468P pinout is located in the pin-assignment section of the official NXP MC14468 manufacturer datasheet. The component uses a 16-pin DIP package with a 0.300-inch, 7.62 mm lead pitch. The supplied search results confirm the public datasheet but do not expose every numbered pin function, so this record does not reproduce an unverified pin table and directs engineers to the official PDF for authoritative assignments.
What is the MC14468P operating temperature range?
The MC14468P is specified for an operating temperature range of -10°C to +60°C. This range appears in the verified TME component listing. For a certified smoke alarm, the IC rating is only one part of the overall design assessment; the chamber, buzzer, power source, enclosure, detector network, and finished-product standards must all remain suitable for the intended installation environment.
Is the MC14468P in stock?
Stock status is not established by the supplied verified records. DigiKey describes MC14468P as buyable and shippable, while the October 30, 2026 search snapshot also contains lifecycle information indicating that the part is obsolete. No dependable quantity-on-hand value was provided, so engineers should request a written quotation and manufacturing-life-cycle status before committing a new production design.
What is the price of MC14468P?
A verified numeric MC14468P unit price is not present in the supplied records. The available pages are for the NXP datasheet, DigiKey, Mouser or Octopart discovery, Octopart listings, and historical datasheet mirrors rather than a timestamped price table. As of 2026-10-30, buyers should request a current distributor quote because no defensible dollar price can be stated from the supplied evidence.
Where can I buy MC14468P online?
MC14468P can be investigated through NXP documentation and the listed DigiKey and Octopart product pages. Because the part is identified as obsolete, availability may be limited to remaining distributor inventory, brokerage stock, or legacy-system maintenance rather than standard active-production supply. As of 2026-10-30, confirm lot traceability, condition, date code, and obsolescence risk before placing an order.
What is the lead time for MC14468P?
The MC14468P lead time cannot be stated reliably from the supplied web data. The NXP and distributor links confirm the product family, package, and historical availability, but no current factory lead-time commitment is included. As of 2026-10-30, request a quotation that explicitly states factory or broker lead time, minimum order quantity, and whether any available stock is new surplus rather than reclaimed component.
What can replace the MC14468P?
The MC14468 is the only closely supported same-family alternative identified from the supplied evidence, and it uses the same 16-DIP ionization smoke detector architecture. However, the supplied cross-reference results do not provide a complete, independently verified list of pin-to-pin replacements. Confirm the package suffix, pin functions, electrical limits, safety requirements, and procurement status before treating MC14468 as a drop-in substitute.
Is MC14468P the same as MC14468?
MC14468P is the orderable plastic-DIP form associated with the MC14468 ionization smoke detector family, while MC14468 is the base family designation used in the NXP datasheet. They share the same functional architecture, but engineers should confirm the exact package, temperature grade, pinout, and order-code details before substitution. The available evidence does not establish additional cross-brand equivalents.
When should I choose the MC14468P instead of another smoke detector IC?
Choose the MC14468P when a legacy or maintenance design specifically requires a 9 V ionization-chamber detector in a 16-pin DIP footprint and the selected supplier can support traceability. Its 12 µA supply current, external piezoelectric drive capability, and interconnect function suit established smoke-alarm architectures. For a new design, an obsolete status and lack of verified current pricing make lifecycle alternatives the more practical choice.
MC14468P vs MC14568: which is better for an ionization smoke alarm?
The supplied evidence verifies MC14468P as a 9 V, 12 µA, 16-DIP ionization smoke detector with interconnect, but it does not provide verifiable MC14568 package, pinout, and electrical data. A functional-family comparison therefore cannot be completed without risking an invalid drop-in recommendation. Use the NXP MC14468 datasheet and verified MC14568 documentation to compare pin assignments, supply limits, chamber-network requirements, and alarm-drive capability.
What are the key specifications of MC14468P that engineers should know?
The principal verified MC14468P specifications are a 9 V DC supply, 12 µA supply current, -10°C to +60°C operating range, ionization input, voltage output, and 16-DIP package. The application network references include 8.2 MΩ and 0.1 nF, and the device drives an external piezoelectric transducer with an interconnect function. Detailed timing, maximum voltage, and pin limits require the official datasheet.

Dados de referência de engenharia para MC14468P — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the MC14468P when maintaining or reproducing an existing design that specifically requires a 9 V ionization-chamber detector, a 16-pin DIP footprint, an external piezoelectric transducer, and an interconnect function. It is also reasonable for a controlled legacy repair program when the source can provide traceable obsolete inventory and the engineer has validated the complete detector network. The specified 12 µA supply current supports low-power standby designs, although the complete power budget must include the alarm transducer. Do not select it solely because a similar ionization-detector IC exists: confirm numbered pin functions, timing, input thresholds, maximum electrical limits, and safety requirements. For a new commercial design, the obsolete lifecycle status, uncertain pricing, and lack of a broader verified drop-in list make a currently supported smoke-detector platform generally more sustainable. If MC14468 is considered instead, verify the exact ordering suffix and qualification details because the supplied evidence establishes family-level compatibility rather than every possible package or grade variant.

Comparação com alternativas

Parâmetro Este produto MC14468
Package 16-DIP (0.300 inch, 7.62 mm) 16-DIP (0.300 inch, 7.62 mm)
Brand NXP Semiconductors NXP Semiconductors
Product Type Ionization smoke detector IC with interconnect Ionization smoke detector IC with interconnect
Supply Voltage 9 V DC 9 V DC
Supply Current 12 µA 12 µA
Operating Temperature -10°C to +60°C -10°C to +60°C
Ionization Chamber Resistance 8.2 MΩ 8.2 MΩ
External Capacitor 0.1 nF 0.1 nF
Alarm Output External piezoelectric transducer External piezoelectric transducer
Interconnect Supported Supported
Technology Low-power CMOS Low-power CMOS

Principais diferenciais

  • Provides an established ionization smoke detector architecture rather than a general-purpose alarm controller (vs MC14468)
  • Integrates interconnect capability with local piezoelement alarm drive (vs MC14468)
  • Maintains a low-power supply requirement for standby smoke detection (vs MC14468)

Notas de projeto

Design the 9 V DC supply and return path for both the detector IC and the external piezoelectric transducer. The verified 12 µA figure describes the MC14468P supply current, not total alarm-system demand. Confirm transducer operating current, startup behavior, interconnect load, and battery or supply capacity so that the actuator is not browned out when the alarm activates.

Preserve the 16-DIP through-hole footprint and the sensing-network layout of the original design where possible. Keep the chamber-connected traces compact and isolate them from buzzer-drive and interconnect paths to reduce noise coupling into the ionization input. Because the supplied search excerpts do not contain the full recommended PCB layout, use the official NXP datasheet and the finished detector's validation requirements as the layout authority.

Do not treat MC14468 and MC14468P as automatically interchangeable without checking the exact package suffix, temperature grade, and pin functions. The verified application references of 8.2 MΩ and 0.1 nF must also be checked against the selected chamber and alarm timing. For any new safety product, include the chamber, buzzer, power source, enclosure, fault conditions, and applicable certification in the qualification process.

Keep the detector operating inside the verified -10°C to +60°C range and account for temperature changes in the external chamber and capacitor rather than relying only on the IC rating. Through-hole thermal performance is normally dominated by the board, nearby components, and enclosure during a sound-alarm event. Verify the chamber response and piezoelectric performance at temperature extremes because changes in the external network can affect detection sensitivity even when the IC itself remains within its rated range.

Informações de conformidade

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

The NXP manufacturer datasheet states that the circuit is designed for smoke detector systems that comply with UL 217 and UL 268 specifications. This describes intended system compatibility and does not by itself establish RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status for the MC14468P. Those fields remain unknown because the supplied records do not provide the corresponding declarations.

Dados verificados em: 2026-10-30 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

MC14468P datasheet PDF NXP MC14468P ionization smoke detector MC14468P 9V 12uA smoke detector IC MC14468P 16-DIP pinout MC14468P lead time and availability MC14468P price quote MC14468P drop-in replacement MC14468P versus MC14468 MC14468P battery smoke alarm MC14468P piezoelectric alarm driver MC14468P interconnect smoke detector What can replace MC14468P? Where to buy MC14468P online MC14468P operating temperature and supply current

Componentes & termos relacionados

NXP Semiconductors Motorola MC14468P MC14468 Low-Power CMOS Ionization Smoke Detector IC ionization smoke detector smoke detector IC sensor and detector interface building safety electronics semiconductor CMOS 9 V DC 12 µA supply current ionization chamber 8.2 MΩ 0.1 nF piezoelectric transducer interconnect 16-DIP through-hole package UL 217 UL 268 RoHS REACH AEC-Q100
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ