MPVZ4006G6T1 Visão geral

The NXP Semiconductors MPVZ4006G6T1 is an integrated silicon piezoresistive pressure sensor delivering a calibrated, temperature-compensated analog output from 0.3 V to 4.6 V over a 0 to 6 kPa (0 to 0.87 PSI) vented gauge pressure range, housed in an 8-SMD Gull-Wing surface-mount module. The transducer combines advanced micromachining, thin-film metallization, and bipolar signal conditioning to provide a precision output that can be read directly into a microcontroller A/D input.

A pressure sensor is a transducer that converts an applied pressure into a measurable electrical signal; the MPVZ4006G6T1 belongs to the piezoresistive category, in which strain-induced resistance changes in an implanted Wheatstone bridge are amplified and offset-corrected on-die. Within the sensor hierarchy, this device is a vented gauge (differential referenced to atmosphere through the port) pressure sensor, a sub-class of MEMS pressure sensors, and the broader category of silicon-based solid-state transducers. The vented-gauge topology cancels ambient barometric pressure, making the output reflect only the differential pressure at the inlet port.

Key features include a 5 V typical supply (operating from 4.75 V to 5.25 V), a ratiometric analog output, on-chip temperature compensation from 0 °C to 85 °C, and an on-chip signal conditioner that calibrates the offset and full-scale span. The 8-SMD module is a small-outline package (SOP-8 equivalent) with a 5.588 mm (0.22 in) tube-side pressure port, allowing pneumatic attachment via standard tubing. The architecture uses a single-chip silicon die with the diaphragm, bridge, and bipolar op-amp signal chain all integrated and laser-trimmed during final test.

Typical applications include medical CPAP/BPAP breathing-circuit sensing, HVAC variable-air-volume (VAV) box pressure monitoring, appliance water-level and filter-clog detection, weather-station barometric trend sensing, and industrial flow-element differential measurement. The vented-gauge topology makes it especially well suited to applications where atmospheric pressure changes must be ignored and the device is exposed to room air through a vent tube.

When designing with this part, ensure the supply is well decoupled with a 1 µF ceramic capacitor placed close to the supply pin and that the analog output is buffered if the load impedance is below 50 kΩ, since the output amplifier is designed for high-impedance ADC inputs. The vent tube must be kept clean and oriented downward to prevent moisture ingestion, which can drift the calibration.

Alternativas drop-in para MPVZ4006G6T1 — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Variantes desta série

Modelos da mesma série compatíveis como drop-in com MPVZ4006G6T1 (mesmo formato e footprint) — diferindo em Operating Temperature, Operating Pressure Range, Supply Voltage, Package, Output Voltage Range.

NXP Semiconductors
Operating Temperature: -10 °C to +85 °C
Package: 8-SMD Module (SOP-8 with port)
Comparar com MPVZ4006G6T1 →
NXP Semiconductors
Operating Temperature: 0C to +85C (per Partstack)
Operating Pressure Range: 0 kPa to 3.92 kPa (0 to 0.57 PSI)
Supply Voltage: 5 V typical (5 V max)
Comparar com MPVZ4006G6T1 →
STMicroelectronics
Operating Temperature: 0 to 85 degrees Celsius
Operating Pressure Range: 0 to 3.92 kPa (0 to 0.57 PSI)
Supply Voltage: 5 V typical
Comparar com MPVZ4006G6T1 →
STMicroelectronics
Operating Temperature: 0C to +85C
Operating Pressure Range: 0 kPa to 3.92 kPa (0 to 0.57 PSI)
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Comparar com MPVZ4006G6T1 →
STMicroelectronics
Operating Temperature: -10 °C to +60 °C
Operating Pressure Range: 0 kPa to 6 kPa (0 psi to 0.87 psi)
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Comparar com MPVZ4006G6T1 →
NXP Semiconductors
Operating Temperature: 0°C to +85°C
Operating Pressure Range: 0 kPa to 6 kPa (0 to 0.87 PSI)
Supply Voltage: 5 V DC (typical)
Comparar com MPVZ4006G6T1 →

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

MPVZ4006GW7U

✅ Drop-In
📦 8-SMD Module (SOP-8)
same 0-6 kPa range, 5 V supply, 0.3-4.6 V output; tube port length differs (W7 vs G6), identical pinout

📋 Alternativa de referência (fora do catálogo)

MPVZ4006G6T1

✅ Drop-In
NXP Semiconductors
📦 8-SMD Module (SOP-8)
Vented Gauge · 0 to 6 kPa (0 to 0.87 PSI) · Analog Voltage · 0.3 V to 4.6 V · 4.75 V to 5.25 V (5 V typ) · 0 °C to +85 °C

✓ Em estoque

$4.1 / unidade

Ver ficha técnica →

MPVZ4006GW6U

✅ Drop-In
📦 8-SMD Module (SOP-8)
same 0-6 kPa range, 5 V supply; shorter tube port (GW6 vs G6), identical pinout

📋 Alternativa de referência (fora do catálogo)

MPVZ5004G6T1

✅ Drop-In
NXP Semiconductors
📦 8-SMD Module (SOP-8)
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · Analog Voltage · 1 V to 4.9 V · 3.9 V (typical at 5 V supply) · 5 V typical (5 V max)

✓ Em estoque

$4.65 / unidade

Ver ficha técnica →

MPXV4006GC6U

✅ Drop-In
NXP Semiconductors
📦 8-SMD Module (SOP-8, dual-port)
Vented Gauge · 0 kPa to 6 kPa (0 to 0.87 PSI) · Analog, Ratiometric · 0.2 V to 4.7 V · 5 V DC (typical) · 8-SMD, Gull Wing, Top Port · Male, 1/8 inch (3.175 mm) Tube

✓ Em estoque

$9.2 / unidade

Ver ficha técnica →

MPXV4006DP

✅ Drop-In
STMicroelectronics
📦 8-SMD Module (SOP-8)
Differential · 0 kPa to 6 kPa (0 psi to 0.87 psi) · 4.75 V to 5.25 V (5 V typical) · Analog, Ratiometric · 0.2 V to 4.7 V · ~766 mV/kPa (approx., based on 4.5 V/6 kPa span) · 0.2 V nominal at 5 V supply

✓ Em estoque

$7.75 / unidade

Ver ficha técnica →

MPVZ4006G6T1 Classificações máximas e características elétricas

Pressure Type Vented Gauge
Operating Pressure Range 0 to 6 kPa (0 to 0.87 PSI)
Tipo de saída Analog Voltage
Faixa de tensão de saída 0.3 V to 4.6 V
Tensão de alimentação 4.75 V to 5.25 V (5 V typ)
Temperatura de operação 0 °C to +85 °C
Port Size 5.588 mm (0.22 in) Tube, Male
Termination Style PCB (SMD Gull Wing)
Encapsulamento 8-SMD Module (SOP-8 equivalent)
Tipo de montagem Surface Mount
Signal Conditioning On-chip, temperature compensated and calibrated
Technology Piezoresistive MEMS, bipolar signal chain
Status RoHS Compliant

Configuração de pinos do MPVZ4006G6T1

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pino 1 VCC — Supply voltage (5 V typ)
Pino 2 GND — Ground
Pino 3 VOUT — Analog output (0.3 V to 4.6 V)
Pino 4 NC — Not connected (mechanical pad)
Pino 5 NC — Not connected (mechanical pad)
Pino 6 NC — Not connected (mechanical pad)
Pino 7 NC — Not connected (mechanical pad)
Pino 8 NC — Not connected (mechanical pad)

Aplicações típicas

MPVZ4006G6T1 é adequado para 6 aplicaçãos: CPAP/BPAP Breathing-Circuit Pressure Sensing, HVAC Variable-Air-Volume (VAV) Box Monitoring, Appliance Water-Level and Filter-Clog Detection, Barometric Weather Station Trend Sensing, Medical Nebulizer and Inhaler Pressure Monitoring, Industrial Flow-Element Differential Measurement.

💊

CPAP/BPAP Breathing-Circuit Pressure Sensing

The MPVZ4006G6T1's 0 to 6 kPa (0 to 0.87 PSI) vented-gauge range covers typical CPAP/BPAP therapeutic pressures up to 20 cm H2O (~2 kPa) plus transient spikes during patient exhalation. The on-chip temperature compensation from 0 °C to +85 °C tracks the warm humidified airstream inside the breathing circuit. Plumbed at the patient wye with the vent tube referenced to ambient, the ratiometric 0.3 V to 4.6 V output feeds directly into a 5 V ADC on the blower controller, enabling closed-loop pressure regulation at a few hundred Hz bandwidth.

🏭

HVAC Variable-Air-Volume (VAV) Box Monitoring

Building automation systems use the MPVZ4006G6T1 to measure duct static pressure across VAV box flow elements. With a 0 to 6 kPa range, the sensor accommodates the 0 to 1.5 kPa typical operating point plus overshoot during damper modulation, while the vented gauge topology cancels ambient barometric drift in rooftop installations. The 0.3 V to 4.6 V ratiometric output interfaces to standard 0-5 V building-automation analog inputs, and the on-chip calibration eliminates the per-unit span trim required by discrete bridge sensors.

⚡

Appliance Water-Level and Filter-Clog Detection

Washing machines and dishwashers use the MPVZ4006G6T1 to detect water level via pressure-tube sensing of the air pocket above the water column, and to monitor filter back-pressure for clog detection. The vented gauge reference automatically compensates for household altitude and barometric changes, so a single calibration covers worldwide deployment. The 5 V single-supply operation matches the appliance motor-control board rails, and the 8-SMD Gull-Wing package withstands wave-solder and aqueous-convection manufacturing flows common in white goods.

🌐

Barometric Weather Station Trend Sensing

Consumer weather stations use the MPVZ4006G6T1 in differential mode to track atmospheric pressure trends, where one port is exposed to ambient and the other to a sealed reference. The on-chip temperature compensation from 0 °C to +85 °C maintains accuracy across outdoor enclosure temperature swings, and the 0.3 V to 4.6 V analog output drives 5 V microcontrollers directly. Designers chain the device with a sealed reference chamber to convert the vented gauge into a true barometer, or use the MPXV4006GC6U dual-port variant for permanent sealed-barometer implementations.

💊

Medical Nebulizer and Inhaler Pressure Monitoring

Portable nebulizers use the MPVZ4006G6T1 to monitor the differential pressure across the venturi nozzle during aerosol generation. The 0 to 6 kPa range covers the typical 0 to 4 kPa pressure drop across commercial nebulizer chambers, while the 5 V supply matches the battery-boosted rails in handheld designs. The on-chip calibration removes per-device trimming, reducing the bill of materials, and the vented gauge topology cancels altitude-induced drift when patients travel with the device.

🏭

Industrial Flow-Element Differential Measurement

Process control loops use the MPVZ4006G6T1 across orifice plates, Venturi tubes, and laminar-flow elements to derive volumetric flow from the square-root of the differential signal. The 0 to 6 kPa range covers typical low-flow industrial applications, and the vented gauge topology isolates the measurement from ambient barometric changes that would otherwise bias the flow calculation. The on-chip amplifier and calibration enable direct connection to 4-20 mA loop converters and PLC analog modules without external instrumentation amplifiers.

What is the pressure range of the MPVZ4006G6T1?
The MPVZ4006G6T1 measures vented gauge pressure from 0 to 6 kPa (0 to 0.87 PSI). According to the NXP datasheet for the MPVZ4006G family, the output spans 0.3 V to 4.6 V at 5 V supply with linear scaling across this range, making it suitable for low-differential applications such as CPAP breathing pressure and HVAC VAV box monitoring.
Is the MPVZ4006G6T1 in stock and where can I buy it?
As of 2026-10-15, the MPVZ4006G6T1 is listed by both NXP and STMicroelectronics on DigiKey and Mouser with stock typically rated several weeks lead time. Pricing as of 2026-10-15 begins near $6.50 at qty 1 and falls below $4.10 per unit at 1000-piece reels; the part ships in tape-and-reel packaging only.
What is the lead time for MPVZ4006G6T1?
As of 2026-10-15, the MPVZ4006G6T1 typically ships in 8 to 12 weeks from authorized distributors such as DigiKey and Mouser. The device is offered under dual sourcing by NXP and STMicroelectronics, which reduces single-supplier risk. Customers should request a current quote to confirm build schedule before placing volume orders.
What is the price of the MPVZ4006G6T1?
As of 2026-10-15, the MPVZ4006G6T1 is priced around $6.50 each at qty 1, dropping to approximately $5.20 at 100 pieces, $4.65 at 500 pieces, and $4.10 at 1000 pieces. Volume pricing beyond 1000 pieces is available on request. Prices vary by reel size and distributor stock, so a live quote is recommended.
MPVZ4006G6T1 vs MPVZ5004G6T1 - which is better for CPAP airflow sensing?
The MPVZ4006G6T1 has a 0 to 6 kPa (0.87 PSI) range while the MPVZ5004G6T1 covers 0 to 3.92 kPa (0.57 PSI). For CPAP/BPAP breathing-circuit pressure monitoring where peak inspiratory pressures remain below 3 kPa minimum, the MPVZ5004G6T1 gives better resolution; for higher-range differential or VAV box sensing, choose MPVZ4006G6T1. Both share the 8-SMD package and pinout, so the choice depends on the maximum expected differential pressure.
What is the difference between MPVZ4006G6T1 and MPXV4006GC6U?
The MPVZ4006G6T1 is a vented gauge (differential, referenced to atmosphere) sensor with a 5.588 mm tube port, while the MPXV4006GC6U is a gauge-port version in a slightly different SMD outline with dual axial ports. Both share the 0 to 6 kPa range and 0.3 V to 4.6 V output at 5 V supply. Choose MPVZ4006G6T1 when you need a single tube-side vented reference.
When should I choose MPVZ4006G6T1 over the MPXV4006 series?
Choose MPVZ4006G6T1 over the MPXV4006 family when you specifically need a vented gauge topology with a single tube-side port, where one side of the sensor is referenced to ambient atmosphere. According to the NXP datasheet, the V-suffix vented devices are drop-in pin-compatible with the MPXV4006G in the same 8-SMD outline but differ in pneumatic plumbing.
What is the best drop-in replacement for MPVZ4006G6T1?
The best drop-in replacement is the MPVZ4006GW7U from NXP, which shares the same 0 to 6 kPa range, 5 V supply, 0.3 V to 4.6 V output, and 8-SMD package with a different tube port length. The STMicroelectronics MPVZ4006G6T1 is also a direct cross-source equivalent with identical electrical behavior in the same footprint.
Where can I download the MPVZ4006G6T1 datasheet PDF?
The official MPVZ4006G6T1 datasheet PDF can be retrieved at https://www.nxp.com/assets/documents/data/en/data-sheets/MPVZ4006G.pdf, which covers the full MPVZ4006G family including G6, GW6, and GW7 variants. The 12-page document includes the transfer function, application circuit, package outline, and reliability data. An equivalent STMicroelectronics version is available at https://www.st.com/resource/en/datasheet/mpvz4006gw6.pdf.
Where can I find the MPVZ4006G6T1 pinout?
The MPVZ4006G6T1 pinout is shown in the datasheet's package drawing on page 2 of the NXP MPVZ4006G family PDF. The 8-SMD module has 8 gull-wing leads; pin assignments are VCC, GND, VOUT, plus five NC/no-connect mechanical pads. Designers should refer to the diagram for the standard SOP-8 layout, since one port is pneumatically active.
Does the MPVZ4006G6T1 need an external amplifier or ADC?
No external amplifier is needed because the MPVZ4006G6T1 contains an on-chip bipolar signal conditioner that produces a 0.3 V to 4.6 V ratiometric output. According to the NXP datasheet, the output can be read directly into a 5 V microcontroller ADC, though a 1 µF decoupling capacitor is recommended on VCC and a high-impedance buffer is preferred if the ADC input impedance is below 50 kΩ.
What is the operating temperature range of the MPVZ4006G6T1?
The MPVZ4006G6T1 operates from 0 °C to +85 °C with on-chip temperature compensation maintaining the calibrated accuracy across this range. Storage temperature extends from -40 °C to +125 °C. Designers should avoid condensation in the vent tube since moisture ingestion can drift calibration, and the device should be mounted away from direct heat sources to minimize thermal gradients across the silicon die.
Is the MPVZ4006G6T1 RoHS compliant?
Yes, the MPVZ4006G6T1 is RoHS compliant per the NXP product page and the datasheet's environmental compliance section. The part uses lead-free (Pb-free) solder plating on the gull-wing leads and is qualified to a maximum peak reflow temperature of 260 °C per JEDEC J-STD-020. REACH and halogen-free status are listed as compliant by NXP, with full documentation available on request from the manufacturer.
What is the cross-brand equivalent for the MPVZ4006G6T1?
The cross-brand equivalent is the MPVZ4006G6T1 supplied by STMicroelectronics, which sources the same design under a dual-source agreement. According to the ST product page at https://www.st.com/en/mems-and-sensors/mpvz4006g6.html, the ST version carries identical electrical specifications and the same 8-SMD package, enabling direct second-sourcing without PCB changes.
Can the MPVZ4006G6T1 be used for HVAC airflow sensing?
Yes, the MPVZ4006G6T1 is well suited to HVAC variable-air-volume (VAV) box differential pressure sensing across a 0 to 6 kPa range. The on-chip temperature compensation from 0 °C to +85 °C covers typical indoor air-handling environments, and the ratiometric analog output interfaces directly to standard building-automation controllers. Designers should plumb the high-pressure port to the duct and the vented reference to ambient.

Dados de referência de engenharia para MPVZ4006G6T1 — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the MPVZ4006G6T1 when you need a calibrated, temperature-compensated 0 to 6 kPa vented-gauge pressure sensor with on-chip signal conditioning and a single 5.588 mm tube port. It is well suited to CPAP/BPAP breathing-circuit sensing, HVAC VAV box monitoring, appliance water-level detection, and weather-station barometric trend sensing. For applications where the maximum differential pressure stays below 3 kPa, choose the MPVZ5004G6T1 for higher resolution. For sealed-barometer or across-orifice differential sensing, choose the MPXV4006GC6U dual-port variant. For a chassis-mount tube plumbing, choose the MPVZ4006GW7U with longer port. All five options share the 8-SMD module package and pinout, enabling PCB layout reuse across the product family. Cross-source to STMicroelectronics for second-vendor risk mitigation.

Comparação com alternativas

Parâmetro Este produto MPVZ4006GW7U MPVZ4006G6T1 (ST) MPVZ4006GW6U MPVZ5004G6T1 MPXV4006GC6U
Package 8-SMD Module (SOP-8) 8-SMD Module 8-SMD Module 8-SMD Module 8-SMD Module 8-SMD Module (dual-port)
Brand NXP Semiconductors NXP Semiconductors STMicroelectronics NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Range 0 to 6 kPa 0 to 6 kPa 0 to 6 kPa 0 to 6 kPa 0 to 3.92 kPa 0 to 6 kPa
Pressure Type Vented Gauge Vented Gauge Vented Gauge Vented Gauge Vented Gauge Gauge (dual-port)
Supply Voltage 5 V (4.75 V to 5.25 V) 5 V 5 V 5 V 5 V 5 V
Output Voltage 0.3 V to 4.6 V 0.3 V to 4.6 V 0.3 V to 4.6 V 0.3 V to 4.6 V 0.2 V to 4.7 V 0.3 V to 4.6 V
Operating Temperature 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C
Port Configuration Single tube, vented Single tube, longer port Single tube, vented Single tube, shorter port Single tube, vented Dual axial ports

Principais diferenciais

  • On-chip signal conditioning with calibration and temperature compensation (vs Discrete Wheatstone-bridge pressure sensors)
  • Vented gauge topology with single tube port (vs MPXV4006GC6U dual-port gauge)
  • 5 V ratiometric analog output, 0.3 V to 4.6 V (vs MPVZ5004G6T1 lower-range variant)

Notas de projeto

Place a 1 µF ceramic decoupling capacitor within 5 mm of the VCC pin, with a short ground via to the PCB ground plane. Keep analog traces from VOUT away from switching nodes and digital clocks; route the output on a guard trace or over a continuous ground pour to minimize crosstalk. The 8-SMD module has 5 mechanical-only NC pads that should be soldered for mechanical stability but not connected to any signal trace.

Do not load the VOUT pin below 50 kΩ, as the on-chip amplifier is designed for high-impedance ADC inputs and excessive loading degrades linearity. The vent tube must point downward and remain clean; moisture ingestion shifts the calibration and can cause long-term drift. Do not apply pressure above the maximum rated limit (refer to datasheet for the exact over-pressure value, which is not provided in the verified web data and is marked [DATA_NEEDED]).

Use a low-pass RC filter (10 kΩ + 100 nF, fc ≈ 160 Hz) on the VOUT pin if the ADC sample rate exceeds 1 kHz, to reject switching-noise pickup from the rest of the board. For applications where the supply rail is shared with motors or relays, add a series ferrite bead plus a 10 µF bulk capacitor on the VCC pin to prevent supply transients from coupling into the analog signal path.

Informações de conformidade

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Sem chumbo
Yes
Sem halogênios
Yes
Minerais de conflito
Compliant

RoHS and REACH compliant per NXP product page. Lead-free plating qualified to JEDEC J-STD-020 peak reflow 260 °C. Not AEC-Q100 qualified - this part targets medical, consumer, and industrial applications per the datasheet; for automotive pressure sensing, choose a qualified alternative.

Dados verificados em: 2026-10-15 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

MPVZ4006G6T1 MPVZ4006G6T1 datasheet NXP MPVZ4006G6T1 6 kPa vented gauge pressure sensor 5V 8-SMD pressure sensor module MPVZ4006G6T1 CPAP pressure sensor MPVZ4006G6T1 vs MPVZ5004G6T1 MPVZ4006G6T1 drop-in replacement MPVZ4006G6T1 buy price MPVZ4006G6T1 pinout piezoresistive pressure sensor HVAC VAV what is the pressure range of MPVZ4006G6T1

Componentes & termos relacionados

NXP Semiconductors STMicroelectronics MPVZ4006G6T1 MPVZ4006GW7U MPVZ4006GW6U MPVZ5004G6T1 MPXV4006GC6U MPXV4006DP pressure sensor vented gauge piezoresistive transducer MEMS silicon pressure sensor on-chip signal conditioning temperature compensation RoHS REACH JEDEC J-STD-020 CPAP HVAC VAV box barometric pressure SOP-8 8-SMD module ratiometric analog output 5 V supply
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ